HomeMy WebLinkAbout99091551- DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCEST.�_L=E COUNTY
SC ANNEc) DEPARTMENT OF COMMUNITY DEVELOPMENT.
• BY 2300 VIRGINIA AVENUE, ROOM 201
LW19 FT. PIERCE, FL. 34982-5652
407-462-1553
DESIGN ,CERTIFICATION FOR WIND LOAD COMPLIANCE
This G p' nation is to be completed by the project design architect or engineer. This Certification must be submitted with all
ap'piicab s for building permit involving the construction of new residence (single or multi -family), residential addition, any accessory . structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided
that no s ructural walls, columns or other similar component is being effected) and certain other minor building permits. For further
assistance", „I please contact the Building Inspection Office at 462-1553 or 462-2172.
PROJEC
T NA
ME ME
B
,1 r�iV LLd v 19�1/ors RUC,
w ......OFF(. ]� t!5>;
........:...:.; ....:...:.:...: ,. ,.. .
STREET ADDRESS �.�� �5ID�CC
PR NUMBER'
Lr/ l AA, 5 s<D PERMIT NUMBER
OCCP. TYPE
CST. TYPE
I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, ' THESE PLANS AND SPECIFICATIONS
HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES
CURRE TLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL
ELEME T S DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND
FORCE;;SPECIFIED BY CURRENT CODE PROVISIONS.
- - - • - -• -- •• •-- • •-..+ r+�.v rJ�umr � Ivns UStU: b
1• BUILDING CODE EDITION USED Om SBCCI
?• UILDING DESIGN IS (CHECK
ONE) ENCLOSED
3• BUILDING HEIGHT: l� r_ rFFr 4.
5.
6.
7.
a.
9.
ASCE 7-.`q 5 _kf�_
PARTIALLY ENCLOSED
OTHER (SPECIFY)
OPEN BUILDING
WIND SPEED USED IN BUILDING DESIGN:. 1 1 Q MPH
EXPOSURE CLASSIFICATION (REFER To ExposuFtE TABLES IN BUR.DING CODE IDENriFlED IN LINE 91):
kGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE
WIND VELOCITY PRESSURE ON,PMUIJOR FACES OF STRUCTURE:
MANCE/USE FACTOR (oerAIN FROM BULDWNG CODE):
is FLOOR '4 O PSF ROOFIDEAD: 7_ PSF
SHEAR WALLS CONSIDERED FOR STRUCTURE (CHECK oNE) YES NO
ation)
CONTINUOUS LOAD PATH PROVIDED (CHECK oNE)
COMPONENT AND CLADDING DETAILS PROVIDED (CHECK o►e:)
nation)
13. M1WIMUM SOIL BEARING PRESSURE O()d PSF
YES �� NO
YES "'� NO
PSF
7, C� PSF
ROOFAJVE: 0 PSF
If NO, why? (attach
If NO, why? (attach
If NO, why? (attach
AS WITt '�ESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION INCLUDED WITH THIS
CERTIFICgTION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF.
NAME: �� C3' (CATION NO:
DESIGN F' M: , ENGINEERING AND TESTING, IS HE
f
Inrl,an Riv(,:- ;-irr1 76A.-8488