Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTFlo C� a Building Code Online SCANNED BY ��e LL, p UM I a 4A�6e A � TIT BCIS Home Log In User Registration Hot TOPICS ( Submit Surcharge 1 Stats & Facts { Publications f Contact Us BCIS SiteMap( Links j Search { Fbi t� Product Approval �pro USER: Public UserFILE COPY �-Product Approval Menu > Product or AOoilcatlon Search > Application LIst > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL11602-R5 Revision 2017 Approved Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43645 (740)321-6345 Greg. Keeler@owenscorning.com Keeler Greg Greg. Keeler@owenscorning.com Greg Keeler 2790 Columbus Road Granville, OH 43023 (740)321-6345 greg.keeler@owenscorning.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 Intertek Testing Services NA, Inc. - QA Entity 12/31/2020 John W. Knezevich, PE J Validation Checklist - Hardcopy Received FL11602 R5 COI 2018 01 COI NIEMINEN odf Standard ASTM D1970 ASTM D226 (physicals) FRSA/TRI April 2012 TAS 110 (weathering) TAS 117(B) https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2-. Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Summary of Products Method 1 Option D 04/20/2018 04/20/2018 04/22/2018 06/12/2018 06/20/2018 FL # Model, Number or Name Description 11602.1 Titanium Roof Underlayments Synthetic sheet -type roof underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL11602 R5 II 2018 04. FINAL ER OWENS Approved for use outside HVHZ: Yes CORNING FL11602-R5.odf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-45 Created by Independent Third Party: Yes Other: 1.) The design pressure noted herein pertains to use Evaluation Reports of a specific underlayment system beneath foam -on tile FL11602 R5 AE 2018 04 FINAL ER OWENS sytsems. Refer to ER Section 5.6.3 for details. 2.) Refer to ER _CORNING FL11602-R5.Ddf Sections 5 and 6 for other Limits of Use. Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee Fl. 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a publlc-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emaiis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click bs[L. Product Approval Accepts: [—-iM .. Safe securityxilhTirics' .floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f rr... 7/ 12/2018 NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY Ow s Corning Roofing and Asphalt, LLC Evaluation Report 111980.11.08-R5 One wens Corning Parkway FL11602-R5 Tole 1 o, OH 43659 Date of Issuance: 11/03/2008 (740 321-6345 Revision 5: 04/19/2018 I SCOPE: This IFvaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. or use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The prodllucts described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESC'IPTION: Titanium'"" Roof Underlayments LAB- ING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted here L CON EDCOMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Qual y Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this valuation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the oduct(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this aluation Report relative to updated Code requirements with each Code Cycle. ADVEIITISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in adve ising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPE1, ION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its di ,, ributors and shall be available for inspection at the job site at the request of the Building Official. This I�aluation Report consists of pages 1 through 7. Prep red by: .t 'i1'•S .'=er. •l.. Robe J.M. Nieminen P.E. F •.,; o� ;,..• : , The facsimile seal appearing was authorized by Robert Florid Registration No. 59166, Florida DCA ANE1983 �:': ;� `4�"�' Nieminen, P.E. on 04/19/2018. This does'not serve as an electronically signed document. CERTIFI TION OF INDEPENDENCE: 1. N MO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or di tributing products it evaluates. 2. N MO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. R bert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for w ich the evaluation reports are being issued. 4. R �bert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the i is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any ject on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained cifically for that purpose. NNEMO I etc. ING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: TitaniumT" Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the intent of the following sections of the 61h Edition (2017) Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Sect Property Standard Year 1507.on Unrolling, Breaking Strength, Pliability ASTM D226 2009 1507:1:1: R905.1.1 Exception Tear Strength ASTM D1970 2015 1507.1.1, T1507.1.1, Physical Properties ASTM D1970 2015 1507.2.9.2 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 TAS 110 Accelerated Weathering ASTM D4798 2011 TAS 110 Pull -through resistance TAS 117(B) 1995 Enti Examination Reference Date ERD (TST6049) Physical Properties 115010.04.09 04/29/2009 ERD (TST6049) Physical Properties 115010.05.10 05/14/2010 ERD (TST6049) Physical Properties 135520.06.11 06/15/2011 ERD (TST6049) ASTM D226 138010.08.11 08/11/2011 ERD (TST6049) Wind Uplift 135520.08.11-1 08/12/2011 ITS (TST1509) ASTM D226 311801000Q-003 04/26/2007 ITS (TST1509) ASTM D226 3130639COQ-002A 08/21/2007 ITS (TST1509) Physical Properties 3126617COQ-005 10/31/2007 ITS (TST1509) ASTM D226 101823107COQ-011 01/23/2015 PRI (TST5878) ASTM D1970 OCF-341-02-01 09/20/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-331-02-02 10/03/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-332-02-02 10/03/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-334-02-02 10/03/2017 PRI (TST5878) TAS 117(B); Pull -through OCF-422-02-02 04/03/2018 ITS (QUA1673) Quality Control ITS Listings Current ITS (QUA1673) Quality Control Service Confirmation 09/30/2017 4.1 11 Self -Adhering Underlayments: coated, synthetic woven sheet. The Linderside Is backed with a -release film: 'Gnit weight— 24"Ibs/square: Meets ASTM-D1970 as'a single layer and meets FRSA/TRI April 2012 when used in 2-ply system. 4.2 Mechanically Fastened Underlayments: 4.2.1! TitaniumTM UDL-25 is a synthetic sheet -type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.5 lbs/square; meets FBC 1507.1.1 & R905.1.1(Exception). 4.2.2 ! Titaniumlm UDL-30 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.0 Ibs/square; meets FBC 1507.1.1 & R905.1.1(Exception). 4.2.3 TitaniUMT"° UDL-50 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.7 Ibs/square; meets FBC 1507.1.1 & R905.1.1(Exception). NEMO E IC, LLC Evaluation Report 111980.11.08-R5 Certificat 'o/Authorization #32455 61" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-RS Titanium Roof Underlayments Revision 5: 04/19/2018 Page 2 of 7 5.1 5.2 5.3 5.4 5.5 5.5 5.6 5.6. 5. OMEMO I etc. This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. This Evaluation Report is not for use in FBC HVHZ jurisdictions. Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Titanium'"" Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. Allowable Roof Covers: TABLE 1: Roolt COVEROPTIONS Asphalt Wood Shakes Underlayment Shingles Nail -On Tile Foam -On Tile Metal & Shingles Slate Titanium PSU-30 Yes Silvassa, India ( ) Yes Yes (See 5.5.1) Yes Yes Yes Titanium PSU-30 (Brentwood, NH) Yes- No No Yes Yes Yes Titanium UDL-25 Yes No No Yes Yes Yes Yes Yes Titanium UDL-30 Yes (Base Sheet in 2-ply (Base Sheet in 2-ply Yes Yes Yes system) system) Titanium UDL-50 Yes No No Yes Yes Yes' "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations. T ABLE 1A, ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS' Adhesive Florida Product Approval Underlayments Dow TileBond'" FL22525 Titanium PSU-30 (Silvassa, India) ICP Adhesives Polyset® AH-160 FL6332 Titanium PSU-30 (Silvassa, India) Allowable Substrates: Titanium PSU-30: Direct -Bond to Deck: ➢ New untreated plywood; ➢ Existing untreated plywood, primed as needed with D41 primer to achieve bond. Bond to Mechanically Attached Base Sheet: ➢ ASTM D226, Type I or II felt. ➢ Titanium UDL-30 (primed with D41 primer) or UDL-30 (inverted). 1 RUB fer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO E C, LLC Evaluation Report 111980.11.08-R5 Certificat ,ofAuthorizotion #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R5 Titanium Roof Underlayments Revision 5: 04/19/2018 Page 3 of 7 ONEMOletc. Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. Maximum Design Pressure = -45 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Underlayment: One or two plies, Titanium PSU-30 (Silvassa, India), self -adhered Maximum Design Pressure=-30 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered Maximum Design Pressure = -30 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps. Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered Maximum Design Pressure = -45 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Fasteners: Spacing: Primer: Underlayment: Titanium UDL-30 (inverted) 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. ASTM D41 primer required at all tin -caps. One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered NEMO El C, LLC Evaluation Report 111980.11.08-R5 Certificate' jAuthorization #32455 61H EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R5 Titanium Roof Underla ments Y Revision 5: 04/19/2018 Page 4 of 7 5.7 5.8 6.1 6.2 NEMO ONEMOletc. 45 Maximum Design Pressure = -45 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps. Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30 (Silvassa, India), self -adhered ,1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. Exposure Limitations: Titanium UDL-25, Titanium UDL-30 or Titanium UDL-50 shall not be left exposed for longer than 30-days. Titanium PSU-30 (Silvassa, India) shall not be left exposed for longer than 90-days. Titanium PSU-30 (Brentwood, NH) shall not be left exposed for longer than 30-days. Tile Slippage Limitations [per FRSA/TRI April 2012 (04-12)1: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIREcT-DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Titanium PSU-30 (Silvassa, India) Flat Max. 10-tile stack 5:12 Lugged Max. 10-tile stack 6:12 Titanium Roof Underlayments shall be installed,in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). LLC Evaluation Report 111980.11.08-RS Authorization #32455 6rH EDITION (2017) FBC NON-HVHZ EVALUATION F1.11602-115 Titanium Roof Underlayments Revision 5: 04/19/2018 Page 5 of 7 6.3 ON EMO I etc. TitaniumTM UDL-25, Titanium UDL-30 or Titanium'UDL-50: Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet - width. 6.3.2 Fasteners: Mechanical attachment of Titanium UDL-25 and Titanium UDL-30 is limited to ring shank roofing nails with minimum 1-inch diameter plastic caps. Mechanical attachment of Titanium UDL-50 is limited to ring shank roofing nails with minimum 3/8-inch diameter heads; ring shank roofing nails with minimum 1-inch diameter plastic caps; screws and plates; or plastic cap staples. 6.3. .1 Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails shall be required where the ultimate design wind speed, Vait, equals or exceeds 150 mph." Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1-inch diameter plastic cap nails in lieu of metal cap nails for these applications, when the TitaniumTM UDL-25, Titanium UDL-30 or Titanium UDL- 50 underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1 or R905.1.1. 6.3.31 SloDes of 4:12 or ereater: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. Minimum attachment shall be 12-inches o.c. vertically and 24-inches o.c. horizontally in accordance with the surface markings on the exposed face of the underlayment. When batten systems are to be installed atop the li underlayment, the underlayment need only be preliminarily attached pending attachment of the battens.. 6.3. Slopes of 2:12 to less than 4:12: Double layer application; begin by fastening a 25-inch wide strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue as noted in 6.3.3, but maintaining minimum 25- inch side (horizontal) laps, resulting in a double -layer application. 6.4 6.4.21 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Direct -to -Deck with Mechanically Fastened Roof Cover: Cut manageable sections and re -roll with the release film side out. Membrane Application: ➢ Peel back release film approximately 1 to 2 feet and align with the lower edge of the roof and set in place, printed side up. ➢ Apply the balance of the membrane to the substrate by removing the film and firmly pressing the membrane into place. ➢ Apply subsequent courses parallel to the eave in a shingle -type, water -shedding manner. ➢ End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum 3-inches. ➢ If the membrane becomes misaligned, cut the roll and re -start. ➢ Upon completion, inspect the membrane and repair any defects or fish -mouths. The use of sealant or mastic at the fastener penetrations is required for all tile roofing installations. Contact Owens Corning Roofing and Asphalt, LLC for approved sealant or mastic types. MEMO ET�, LLC Certificate f Authorization #32455 Evaluation Report 111980.11.08-R5 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-RS Titanium Roof Underlayments Revision 5: 04/19/2018 Page 6 of 7 r r i OMEMO etc. 6.43 Tile Applications [Titanium PSU-30 (Silvassa, India) onlyl: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Owens Corning Roofing and Asphalt, LLC published requirements for tile staging. Owens Corning Roofing and Asphalt, LLC specifies minimum 24-hour cure time after installation, before loading of roofing tiles. The use of sealant or mastic at tile fastener penetrations is required for all the roofing installations. Contact j Owens Corning Roofing and Asphalt, LLC for approved sealant or mastic types. 6.5 Titanium2-Ply'Systerr 6.5;1 The Titanium 2-Ply System consists of a base layer of Titanium UDL-30 (top -surface primed or inverted) mechanically attached to the wood roof deck followed by Titanium PSU-30 (Silvassa, India), self -adhered. 6.5i 2 Non -Tile Applications: Install Titanium UDL-30 (top surface primed or inverted) in accordance with Sections 6.3.1 through 6.3.3 followed by Titanium PSU-30 (Silvassa, India) in accordance with Section 6.4. 6.5 3 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing, refer to Owens Corning Roofing and Asphalt, LLC published installation instructions, but not less than the fastener density from FRSA/TRI April 2012 (04-12), Table 1, taking into account the wider sheet -width. For adhesive -set tile roofing, refer to Section 5.6.3 herein. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Owens Corning Roofing and Asphalt, LLC published requirements for tile staging. Owens Corning Roofing and Asphalt, LLC specifies minimum 24-hour cure time after installation, before loading of roofing tiles. The use of sealant or mastic at tile fastener penetrations is required for all tile roofing installations. Contact Owens Corning Roofing and Asphalt, LLC for approved sealant or mastic types. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 18. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. Plant Specification . Product s Mission, BC, Canada. FBC 1507.1.1 (Exception) Titanium UDL-30; Titanium UDL-50 Qingdao, China FBC 1507.1.1(Exception) Titanium UDL-25; Titanium'UDL-30; Titanium UDL-SQ Silvassa, India FRSA/TRI 04-12 (2-ply system) Titanium PSU-30 (Silvassa, India) B� ._N(i _ �. ram_ �Centwood ASTM D1970'- Titanlum PSU rentwood;-'NH), 9. QUALITY ASSURANCE ENTITY: Intertek Testing Services NA Inca— QUA1673; (604) 520-3321 - END OF EVALUATION REPORT - NEIY ETC, LLC Evaluation Report 111980.11.08-R5 Certi cote of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-RS Titanium Roof Underlayments Revision 5: 04/19/2018 Page 7 of 7