HomeMy WebLinkAboutOPTIONAL LOAD CALCULATIONSLucle.County
,tionei Load Calculation
heat Larger Than Air
(2) Small appliance ckts @ SFx3VAL)vingOnly
1SOOVA each
Refrigerator @ 1500
Refrigerator @ 1500
Freezer @ 1500
Washing Machine @ 1S00
Dishwasher @ 1500
Disposal @ 1500
sT.Lucre cou vTI'
Mini Sewer @ 1500
PLAN REVIEW
Clothes Dryer @ 5000
Range @ 12000
Water heater @ 4500
BATE: --�
DATE:
Fixed microwave @ 1500
ELEO,d�
Vacuum @ 1500
DATE.:-jj
Trash Compactor @ 1500
PLUMB:
Pool Heater @ name.plate,
Spa @'name plate'
DATt=:
• -------
Motors 746VA per Hp
MECH:�_
Garage Door Opener
DATE:
1) Total
2) First 10 KVA of general load @ lo0%
3) subtract line 2 from 1
4) Multiply line 3 @ 40%
5) Add lines 2 and 4
6) 60/50amp breaker for heat (10000)
7) 40/30amp breaker for heat (50oo)
s) Total heat- Add lines 6 and 7
9) Multiply line 8 @ 65%
10) Add lines 5 and 9
11) Divide line 10 by 240
Summary;
Line 10 Is the total KW
Line 11 Is fihe total Amps '
RECEIVED,'
JUL -10 268
Mitting Department
St. Lude County
.
! (Generator size Needed)
(Breaker Size Needed)