HomeMy WebLinkAboutPRODUCT APPROVALr
3/12/201
I
Florida Building Code Online
x,$ SCANNED, mac.
BY rig ,. ?;✓#P ty
e � St. Lucie County
BCIS Home Log In User Registration Hot Topics _ Submit Surcharge Stats & Facts Publications FBC Staff BCIs site rlap Links Search
a
Product Approval
USER: Public User i
Product ADDfOVai Menu > Product or Application Search > A licati ist > Application D tall
x FL # FL16027-R2 {DECEIVED '
Application Type Revision
Code Version 2017 J U N 2 9 20 i 3
Application Status Approved i
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email: , -
Quality Assurance Representative
Address/Phone/Email '
ST. Lucie County, Permitting
Tri-Built Materials jr , %Z4—
PO Box 70 ST. LUCIE COUNTY BUILDING DI ISIO
Rutherford, NJ 07070 REVIEWED FOR COMPLIAN
(800)516-1485
david. ruiz@tribuiltmg.cpfVIE B
DATE TiON ]OB
PLANS A PERMIT MUST,B WILL BE MADE
David Ruiz ,$TE OR NO INSPECTION(S) - david.ruiz@tribuiltmg.c
r
David Ruiz
250 Route 17 North
- East Rutherford, NJ 07073
(201) 842-2449
david.ruiz@tribuittmaterialsgroup.com
C Richard SchurmarrMES.E PLANS AND All, PROPOSED;WORK
9050 Louisiana StreARE SUBJECT TO ANY CORRECTIONS
Merrillville, IN 4641(REQUIRED BY FIELD INSPECTORS THAT
rich.schurman@allieMAYrBEC ECESSARY IN ORDER TO i
COMPLY WITH ALL APPLICABLE CODES.
Category 'Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who, developed the Robert Niemineri
Evaluation Report
Florida" License - PE-59166
Quality Assurance Entity UL LLC FILE COPY
Quality Assurance Contract Expiration Date 10/06/2018
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FALED FASTENERS OR ATTACHME,:NTS
IRE THE RESP061SIBILITY OF THE
CONTRACTOR OR RECORD
FL16027_R2_COI_2017_O1_COI_Nieminen.pdf
Standard Year
ASTM D6163 2008
ASTM D6164 2011
ASTM D6222 2011
FM 4470 _ 2012
FM 4474 2011
Equivalence of Product Standards
Certified By
3/12/201
Sections from the Code
Florida Building Code Online
Product Approval Method
r
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
09/25/2017
09/30/2017
10/08/2017
12/12/2017
FL #
I Model, Numtrer or Name
Description
116027,1 TRI-BUILT Modified Bitumen Roof
----�
I SBS and APP modified bitumen roof systems
Systems
A
---
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16027 B2_II_2017_09_FINAL_AI_ER_TRI
Approved for use outside HVHZ: Yes
BUILT _MODBIT_FL16027-R2.pdf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
i other: 1.) The Design Pressure noted in this application refers
Evaluation Reports
to one system. Refer to ER Appendix for all systems and max.
FL16027_R2_AE_2017_IZ IF NAL_ER TRI-
design pressures. 2.) Refer to ER Section 5 for Limits of Use.
1
BUILT _MODBIT_FL16027-R2.odf
Created by Independent Third Party: Yes
Contact Us : 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy atatement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
'Cn+ GW�:' eCr�ci
Credit Card
Safe r
httnc•//flnri ahi016inn nrn/nr/nr ann rill acny?naram-ui(,F\/Ynuttnntppmrivimn%A/rylftgYl Iwvo/?fl XRhnakRf?i.lC'i inwhthiiAn0/brie/.Arl ?li
EXTERIOR RESEARCH & DESIGN, LLC:
Certificate of Authorization #19503
353 Christian Street
ER® Oxford, CT 06478
(203)262-9245
EVALUATION REPORT
TRI-BUILT Materials Group,
PO Box 70
Rutherford, NJ 07070
(800)516-1485
Evaluation Report A4Z97U.1U.1Z-KZ
FL16027-R2
Date of Issuance:10/23/2012
Revision 2: 09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 61th Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: TRI-BUILT Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. I
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site atthe request of the Building Official.
This Evaluation Report consists of pages 1 through 4, plus a 26-page Appendix.
Prepared by:
O
Robert J.M. Nieminen, P.E.
` The facsinuleseaI a ppeanng was authorized by Robert Meru ineu,
Florida Registration No. 59166, Florida DCA ANE1983 G.E on 09/2i/2017 This does not serve as an electronically signed
_IJ�,rrnmr:r'� da'c.ument.
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does, not have, nor does it intend to acquire or will it acquire, a financial interest
in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity„ I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
i
APPEN61K 1 ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Page
Table
Deck
Application
Type
A-2
Description
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
4
1A•1
_.xnF_m
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5
VVood
New, Reroof (Tear -Off) or Recover
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
5
18
Wood
New, Reroof (Tear -Off) or Recover
B
6
_
1C
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
6
1p
Wood
New, Reroof (Tear -Off) or Recover
D -
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
1E-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
7
lE-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
8
1F
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
8
9
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
9
2B
Steel or Structural concrete
New, Reroof (Tear -Off) orRecover
C
Mech. Attached Insulation, Bonded Roof Cover
10
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
11-14
14
36
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
15 16
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover _
16
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
4B
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
17-19
SA
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
20
20
21
5B
CWF
OffRecover
New, Reroof (Tear-) orecov
A-2
Mech.-Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5C
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22
5D
CWF
New, Reroof (Tear -Off) orRecover
C
Mech. Attached Insulation, Bonded Roof Cover
22
22
5E
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
6A
Gypsum
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
23
24
613
Gypsum
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
6C
Gypsum
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
24
24
6D
Gypsum
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
25-26
26
713
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
Wood: Minimum 0.75-inch penetration.
� Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocya n u rate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 15051 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
Evaluation Report A42970.10.12-R2 for FL16027-R2
Exterior Research and Design, LLC. d/b/a Trinity) ERD
6'"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
Certificate of Authorization #9503 Appendix 1, Page 1 of 26
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485
Ti RINIT ER®
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
TABLE 1: TRI-BUILT ROOF COVERS
Reference
Layer
Material
Application
BP -AA
(Base and Ply sheets, Asphalt -Applied)
Base Ply
FBC Approved ASTM D4601, Type II
HA at 20-40 Ibs/square
Ply
FBC Approved ASTM D2178, Type IV or VI
SBS-AA
(SBS, Asphalt -Applied)
Cap Ply
TriBuilt SBS Granular
HA at 20-40 Ibs/square
SBS-TA
(SBS, Torch -Applied)
Cap Ply
TriBuilt SBS Granular
Torch -Applied
SBS-SA
(SBS, Self -Adhering)
Base Ply
TriBuilt:5A SBS Base
Self-Adhering
Cap Ply
TriBuilt SA SBS Cap
APP-TA
(APP, Torch -Applied)
Base Ply or Ply
TriBuilt APP Smooth
Torch -Applied
Cap Ply
TriBuilt APP Smooth, TriBuilt APP Granular
APP-SA
(APP, Self -Adhering)
Cap Ply
TriBuilt SA APP Cap
Self -Adhering!
16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MOP) limitations. The lesser of the MOP listings below vs. those in Table 3A
VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; ADHERED INSULATION PER TABLE 3A. -
Option #
Primer
Vapor Barrier
Insulation Adhesive
MDP (psf)
Type
Attach
VB-1.
ASTM D41
TriBuilt SA SBS Base
Self -Adhering
Inta-Stik or CR-20, 12-inch o.c.
60.0
VB-2.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
Insta-Stik, 12-inch o.c.
-75.0
VB-3.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
Millennium One Step Foamable Adhesive, 12-inch o.c.
157.5
VB-4.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
CR-20, 12-inch o.c.
270.0
VB-S.
ASTM D41
TriBuilt SA SBS Base
Self -Adhering
g
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20, 12-inch o.c.
290.0
17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements.
18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, LLC. d/b/a Trinity) ERD va ua ion KepOrt AL4ZWU.1=112-forftl(5027=R2
Certificate of Authorization 49503 6 EDITION (2017) FBC NON-HVH2 EVALUATION Revision 2: 09/25/2017
Prepa¢ed by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 3 of 26
TABLE 1E-2: WOOD DECKS— NEW CONSTRUCTION, REROOF (TEAR=OFF) oh REcovER .
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER ..
System
Base Sheet
Roof Cover (Note 15)
MDP
No.
Deck (Note 1)
Base
Fasteners
Attach
Base Ply
Cap Ply
(psf)
Min. 19/32-inch
Polyglass Elastobase, Polyglass Elastobase
OMG Flat Bottom Plates (square) with
12-inch o.c. in 4-inch lap and 12-inch
(Optional) One or
SBS-AA, SBS-
W-1
plywood at max.
Poly, Polyglass G2 Base, CertainTeed
Roofgrip #14, Dekfast Hex with Dekfast 414
o.c. in two, equally spaced, staggered
more BP -AA or
TA, APP-TA
-52.5
24-inch spans
Glasbase, Firestone MB Base, JM Perma-
or TruFast MP-3 with TruFast HD
center rows
APP TA
Ply 28, Tamko Glass Base or GAFGLAS #75
W-2
Min. 19/32-inch
plywood at max.
Polyglass Elastobase or Polyglass
Dekfast Hex with Dekfast #14 or TruFast MP-
12-inch o.c. in 4-inch lap and 12-inch
o.c. in two, equally spaced, staggered
One or more SBS-
SBS-SA, APP-
SA, SBS-TA or
-52.5*
24-inch spans
Elastobase Poly with poly top surface
3 with TruFast HD
center rows
SA
APP-TA
W-3
Min. 19/32-inch
plywood at max.
Polyglass Elastobase or Polyglass
OMG Flat Bottom Plates (square} with
12-inch o.c. in 4-inch lap and 12-inch
O.C. in two, equally spaced, staggered
(Optional) One or
more BP -AA or
SBS-AA, SBS-
-60.0
24-inch spans
Elastobase Poly
Roofgrip #12
center rows
APP-TA
TA, APP-TA
W-4
Min. 19/32-inch
plywood at max.
Polyglass Elastobase or Polyglass
OMG Flat Bottom Plates (square) with
12-inch o.c. in 4-inch lap and 12-inch
o.c. in two, equally spaced, staggered
One or more SBS-
SBS-SA, APP-
SA, SBS-TA or
-60.0*
24-inch spans
Elastobase Poly with poly top surface
Roofgrip #12
center rows
SA
APP-TA
TABLE 1F: VOOD DECKS- NEW CONSTRUCTION OR REROOF &9E i-OFF)
SYSTEM TYPE F. NON -INSULATED, BONDED ROOF ,COVER ,' ,',
System
Roof Cover (Note 15)
MDP
No.
Deck
Primer
(psf)
Joint Treatment
Base Ply
Ply
Cap Ply
W 5
Min. 15/32-inch plywood
(Optional) ASTM D41
None
SBS-SA
(Optional) SBS-SA or
SBS-SA, APP-SA, SBS-TA
90.0
at max. 24-inch spans
APP-TA
or APP-TA
W-6
Min. 15/32-inch plywood
(Optional) ASTM D41
Plywood joints are covered with 4-inch wide strips of TriBuilt SA
TriBuilt SA SBS Base
(Optional) SBS-SA or
SBS-SA, APP-SA, SBS-TA
g7 5
at max. 24-inch spans
SBS Base, rolled into place to create continuous bond.
APP-TA
or APP-TA
0
Exterior Research and Design, LLC. d/b/a Trinity ) ERD Evaluation Report A42970.10.12-R2 for FL16027-112
Certificate of Authorization 99503 6`" EDITION (2017) FBC NON-HVH7 EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 8 of 26