HomeMy WebLinkAboutCERTIFICATION REPORT,BCANNED
BY
al. Lucie County
EYSTO1 V U
ERTIFICATION6. 1Nc.
Metal Roof Certification & Listing Program
Certification Report '
11030-002-KCI
145 Limekiln Road, Suite 100B Issue Dated: 10/27/2017 ;
! Ne I Cumberland, PA 17070 Revision Date: 10/27/2017
i i .kevstonecerts.com Expiration Date: ` 10/27/2022
1.
1st
FILE COPY
ST. LUCIE COUNTY BUILDING D.IVI ION
:ruction Specifications Institute (CSI) Category: REVIEWED FOR COMPLIANCE
REVIEW B G
,ision: 07 00 00 —Thermal& Moisture Protection DATE _. / E=
coon: 074113—Metal Roof Panels PLANS AND PE MIT MUST BE KEP CJ JOB
SITE OR NO INSPECTION($) WI - MADE
Licensee:
�T COAST
METAL ROOFING SUPPLY
Metal Roofing Supply
186 SR 207
East Palatka, FL 32131
386 325-0242
httD.�//Www.lstcoastmrs.com/
2. Certified Roof Covering:
15L oast Metal Roofing Supply's Model Armour Rib 29
Ga. iIon-structural through -fastened metal roof panels
inst sled over plywood sheathing roof deck for use in
new I-onstruction and re -roofing applications.
3. Scope of Certification:
This Certification Report provides technical data
sub tantiating that the use of the certified roof covering
and the evaluated roof systems are in compliance with
the f' Ilowing:
• 717 Florida Building Code - Building, 6th Edition,
Section 1504.3.2.
Florida Product Approval Rule 61G20-3.
Properties Evaluated:
• Wind Uplift Resistance
• Resistance to Foot Traffic
4. Evaluated Roof System Description:
4.1. Roof Covering: Armour Rib 29 Ga. metal roof
covering panels are cold roll -formed from minimum 29
gauge (0.0153" / 0.389mm coated thickness) steel sheet
having a minimum yield strength of 99.7ksi. The panels
are aluminum -zinc alloy coated per ASTM A792 (AZ50),
and shall be installed in accordance with the
manufacturer's instructions and this Certification Report.
4.2. Roof Deck: Armour Rib Panel metal roof panels
are certified for use over solid or closely -spaced, nominal
15/32" B-C 4 Ply Plywood sheathing complying with 2017
Florida Building Code, Section 2303.1.5, with or without
the use of 1x4 #2 SWP purlins at 24" O.C., with a
minimum slope of 4% (1/2:12). Lap sealant shall be
applied for installed slopes less than 25% (3:12).
4.3. Anchorage: Armour Rib 29 Ga. metal roof panels
shall be through -fastened to the roof deck using #10-15
x 1-1/2" Woodgrip hex -head wood screws with bond -
seal washer, as specified in Table 1, applied in the
patterns described in Appendix 1.
Refe to www.kevstonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by
the 1, jilding official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or
suitability of a product for a given use.
I
S.
this
app
201
this
Metal Roof Certification & Listing Program
E:YS O Certific
ation fi
catoon Report
ERTI FICATIONS,. IIV C.
---- �-1 11030-002-KCI 6064
Page 2 of 4
Rib 29 Ga. metal roof panels in new construction
tions shall be installed in accordance with the
Florida Building Code Section 1507.4, the
icturer's published installation instructions and
tification Report.
ur Rib 29 Ga. metal roof panels in re -roofing
ations shall be installed in accordance with the
Florida Building Code Sections 1507A & 1511, the
facturer's published installation instructions and
ertification Report.
The manufacturer's installation instructions shall be
mad Ie available at the time of installation. If there are
differences between this report and the manufacturer's
inst llation instructions, this report shall take
6. roduct Performance
The performance of the Armour Rib 29 Ga. non-
stru itural through -fastened metal roof panels described
in this Certification Report has been determined in
accordance with:
•
•
As
UL 580-94, Tests for Uplift Resistance of Roof
Assemblies.
UL 1897-98, Uplift Tests for Roof Covering Systems.
FM 4470, Resistance to Foot Traffic Test.
& reported by the following independent
laboratory:
Laboratory
Report Ref.
Fo
ce Engineering & Testing
384/593-0030T-10A, B
384/593-0030T-10C, D
384/593-0030T-10E
Note: The UL 580-94 standard is equivalent to the UL
580-06 standard, and the UL 1897-98 standard is
equivalent to the UL 1897-2012 standard.
6.1. Wind Resistance
The allowable design uplift pressures for Armour Rib 29
Ga. anchored as described in Appendix 1, when tested in
accordance with the referenced standards with an
applied safety factor of 2.0 are found in Table 1.
Table 1
Max
AnchorDesign
Anchor
Description
Pattern
Man'f &
Uplift
Model
Pressure
SFS HiLo
Over 15/32"
4 Ply
A
Woodgrip
78.5 psf ,
#10-15 x 1-
Plywood
1/2"
SFS HiLo
Over 15/32"
4 Ply
B
Woodgrip
108.5 psf,
#10-15 x 1-
Plywood
1/211
Over 1x4
SFS HiLo
Purlins Over
A
Woodgrip
108.5 psf
15/32" 4 Ply
#10-15 x 1-
Plywood
1/2"
Over 1x4
SFS HiLo
Purlins Over
B
Woodgrip
183.5 psf
15/32" 4 Ply
#10-15 x 1-
Plywood
1/2"
Ref T to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by
the (building official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or
suitability of a product for a given use.
i
6.2.
The.
sta
-1 1--- Metal Roof Certification & Listing Program
:YSTO, Certification Report
:ERTIFIOATIONS, INC.
-----�®%= = 11030-002-KCI_
Page 3 of 4
Resistance to Foot Traffic
Amour Rib 29 Ga. non-structural through -fastened
I roof panels were tested per the referenced
lard installed using Anchor Pattern A over 1x4 SWP
is over 15/32" 4 ply plywood. The resultant
ction under load and permanent deflection were
n the allowable limits defined by the standard.
7, onditions of Use
Arm ur Rib 29 Ga. non-structural through -fastened
met I roof panels must be insulated against other
materials or metals including concrete, lead, copper and
trea �ed lumber that contains corrosive materials.
S. Limitations of Use
ArmI ur Rib 29 Ga. non-structural through -fastened
met roof panels are not qualified for use in the High
Velc pity Hurricane Zone (HVHZ).
Fire classification, shear diaphragm design, roof deck
design & attachment to supporting members are not
with In the scope of this Certification Report.
Roo support framing shall comply with 2017 Florida
Buill ing Code Chapter 22 for steel, Chapter 23 for wood
and Chapter 16 for structural loading.
9. Licensed Manufacturing Facilities
This Certification Report is applicable only to Armour Rib
29 a. non-structural through -fastened metal roof
pan is manufactured at the following locations:
1st Coast Metal Roofing Supply
186 State Rd 207
East Palatka, Florida 32131
Each licensed facility is subject to periodic inspection by
Keystone Certifications to verify conformance with
Keystone Roof Covering Certification & Listing Program
requirements.
10. Identification
Armour Rib 29 Ga. non-structural through -fastened
metal roof panels represented by this report shall be
identified with Keystone Roof Covering Certification &
Listing Program certification labeling illustrated below,
to be applied to individual panels, packaging, invoicing or
bills of lading:
keystonecerts.com
CERTIFIED � •
11030-002-KCI
cn=Aaron Schultz,
i o=Keystone
Certifications,
LemValidation Dept,
email=aschultz@keyst
.onecerts com, c=us
r 2017.10.2T15' 2935
-04'00'
Aaron Shultz
Validations Manager
Refei to www.keystonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by,
the to
official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or,
suitability of a product for a given use.
Metal Roof Certification & Listing Program
,YSTONE- Certification Report
ERTIFICATIO.rJS,. 1 tYC.
--�—�- 11030-002-KCI
Page 4 of 4
AOpendix 1 Note: In all cases (new construction and re -roofing), the
anchors shall fully penetrate the purlins or the
plywood roof deck (as applicable).
Anchor Pattern A
g. 8. 0.
`/10-15 x 1 1/2' H0.0 1'M000GPoP
STANDARD FASTENER PATTERN 0 24' O.C.
6' 3' 6' r 6. 3' V 3'
Pattern 6
/10-15 x 1 1/2' M(LO WOOOGftlP
PANEL END PATTERN
3 - - 6' 3. 6. 3.
` /10-15 x 1 1/2' Ml0 W000f.W
STANDARD FASTENER PATTERN 0 2r O.C. AND PANELS ENDS
Refe to www.kevstonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted by
the ilding official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance on
suitability of a product for a given use.
11
i
E:YSTO
ERTIFIGATIONS. INC.
, Suite 100B
PA 17070
ts.corn
Metal Roof Certification & Listing Program
Certification Report
11030-002-KCI
Issue Datea: lu/4//zuli
Revision Date: 10/27/2017
Expiration Date: 10/27/2022
Certificate Revisions
Rev #
Date
Description
0
10/27/2017
1 Initial issuance.
the b
I
to www.kevstonecerts.com to ascertain the ongoing status of this Certification Report. Approval of building products and/or materials can only be granted b
Biding official having jurisdictional legal authority. Keystone Certifications, Inc. does not endorse or make warranties with respect to product performance or,
suitability of a product for a given use.