5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min. 24" Coverage 3/8" rib height thru fastened
e: 15/32" APA plywood, Grade C-D; Non -Structural
n Resistant Compliant: #9-15 WoodZac° w/ Zac head w/ sealing washer or approved
through panel rib, %" min. penetration through plywood.
Shall be in compliance with FBC Sec. 1507.
**Design
Pressure:
Fastener Spacing:
-10
0.5 PSF
@ 12" o.c.
-15
�.5 PSF
@ 6" o.c. in panel rib
Reference Data:
Force engineering & Testing (TST-1654) 194-013ST-07 E-G UL 580-941/UL
1. The IPL 580-94 test standard is equivalent to UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to UL 1897-12 test standard. "Design Pressure
Margin of Safety Factor 2:1
Uhderlayment to be compliance with current Florida Building Code (FBC)2017 6TH ed.. see Chart 1507.1.1
1. Minimum slope compliant with Florida Building Code 2017 6th ed., and Manufacturer's installation reference.
2. Pr�ducts are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
3. Engineering analysis for "project specific approval by local authorities is allowed by registered engineers.
4. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
5. SubI art framing in compliance w/FBC 2017 6th ed Chapter 23 Wood and Chapter 16 Structural Loading.
6. This report does not imply warranty, installation, recommended product use outside of this report.
of Independence:
Locke owden, P.E. does not have, not will acquire a financial interest in any company manufacturing or distributing products
under his evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or distributing products under this
�3 ©r+-D/V
�T-Jead-YV06-
ST. LUCIE OUNTY BUILDING D I0N
REVIEWED FqR COMPLIANC
REVIEW.Eal:
DATE
PLANS AN PERMIT MUST BE K N JOB
SITE OR NO INSPECTION(S) BE MADE
,,%°°�E D . 130
o o �\GEN�°IooF2��i
Nn4 9:7
7
° G�D��o STATE OF oal �7
0A1A
-/U/U • loll tree: iSbn-4ii-ouou ' rdX 3:)L-/4L-IU/7 ' W HU11luu 11.Unl ' LOJLO I,UUIII.y nuaU JUi,
A
SV Crimp
Over Plywood
Installation Instructions
^- ^ AA i 3/811
24"
® 2017 Mid -Florida Metal Roofing SUpply, Inc.
5V Panel Fastener Location
PANEL
FASTENER MINIMUM #9 X 1%"
WATERPROOF
MEMBRANE
SUBSTRUCTURE
12- O.C. MAIN FIELD
6" O.C. PERIMETER
MFMRSE
Fax 352-742-7075 - www.mfmrs.com - 28328 County Road 561, Tavares, Florida 32778. 352-742-7070 - Toll Free: 866-479-8080
® 2017 Mid -Florida Metal Roofing Supply. Inc.
5V Panel Fastener Location at Eave
24" O.C. NOMINAL COVERAGE
MFMRSP
- Fax 352-742-70.752 w_ww.mfmrs.com- 28328_County- Road -5.61, Ta.var-es,-Flo.r.ida .327-78. 352-742-7070- - To-1-1-Free.: 866-479-8080
0 2017 Mid -Florida Metal Roofing Supply, Inc.
5V Panel Fastener Location at Valley
MFMRS?
-- - -- Fax 352-742-7075 - www.mfmrs.com 28328 County Road 561,-Tavares, Florida 32778 - 352-7.42-7-070 - Toll Free: 866-479-8080
0 2017 Mid -Florida Metal Roofing Supply. Inc.
OUTSIDE
CLOSURE
PANEL
5V Ridge and Hip Detail
HIP OR RIDGE TRIM
a6 O
MINIMUM 30# FELT
CONTINUOUS BUTYL TAPE
(Top And Bottom of Closure)
LTAIN wilY9I9l19111►19- : llISFA19
MINIMUM #9 X 1%"
SCREW AT EACH RIB
MFMRSI
Fax_ 352-742-7075 . www.mfmrs.com___ 28328_ County Road 561,_Tavares, Florida 32778- 352-742-7070 Toll_ Free: 866-479-8080
0 2017 Mid -Florida Metal Roofing Supply. Inc. � ��
Isometric View of Ridge over Wood Deck
RIDGE FASTENER
CAP
UNDERLAYMENT
5V CRIMP PANEL
OUTSIDE
CLOSURE
BUTYL
TAPE SEALER
SUBSTRUCTURE
MFMRSP
--- — Fax 352-742-70.75 www.mfmr-s.com- 28328-County-Road -561, Tavares,- Florida-327-78 35-2-742-7070 TOLL Free: 866-479-8080 _
0 2017 Mid -Florida Metal Roofing Supply, Inc.
5V Rake Detail
MINIMUM #9 X 11/2" SCREW
WITH NEOPRENE
WASHER AT 12- O.C.
PANEL
CONTINUOUS
BUTYL TAPE
MINIMUM 15�32"
RAKE
FLASHING
MFMRSOU
Fax 352-742-7075 - www.mfmrs.com_ 28328_ County_ Road561. Tavares, Florida 32778_- 352-742-7070 - Toll_ Free: 866-479-8080
© 2017 Mid -Florida Metal Roofing Supply, Inc.
5V Eave Detail
PANEL
MINIMUM 30# FELT
MINIMUM 15/32-PLYWOOD
10 X 11/2- SCREW WITH
WASHER (6) PER PANEL
INSIDE CLOSURE
CONTINUOUS BUTYL TAPE
(Top And Bottom Of Closure)
10-12 X 1- PANCAKE
SCREW AT 12- O.C.
EAVE FLASHING
FASCIA
MFMRS211
Fax_ 352-742-7075 www.mfmrs.com .28328 County_ Road_ 561, Tavares, Florida 32778. 352-742-7070 • _Toll Free: 866-479-8080
® 2017 Mid -Florida Metal Roofing Supply, Inc.
MINIMUM
30# FELT
FULL SHEET
IN VALLEY
CONTINUOUS
BUTYL TAPE
MINIMUM #9 X 11/2"
SCREW WITH WASHER
(6) PER PANEL
5V Va I I ey Detail
INSIDE CLOSURE
STRIP SEALANT
VALLEY
FLASHING
3 Y2"
4
b sS
VALLEY ENDLAP
4" MINIMUM
PANEL
.
00
.000
10-12 X 1" PANCAKE
SCREW AT 12- O.C.
MINIMUM 15�32„
PLYWOOD SHEATHING
WMRSI
Fax 352-742-7075 - www.mfmrs.com - 28328 County Road 561, Tavares, Florida 32778. 352-742-7070 • Toll Free: 866-479-8080
0 2017 Mid -Florida Metal Roofing Supply, Inc.