HomeMy WebLinkAboutOPTIONAL LOAD CALCULATIONSWNW
By
o LQCIG count
E:7 - Optional Load Calculation
Heat larger Than Air
15-6 SF x 3VA Living only
(2) Small appliance ckts @ 1500VA each
Refrigerator @ 1500
Refrigerator @ 1S0o
Freezer @ 1500
Washing Machine @ 1500
Dishwasher @ 150o
ST.LUCIE COUNTY
Disposal @ 1500
PLAN REVIEW
—_`
Mini sewer @ 1500
Clothes Dryer @ 5000
BLDG:
Range @ 12000
DATE:
Water heater @ 4500
Fixed microwave
ELE /'
@ 1500
DATE
Vacuum @ 1500
PLUMB:
Trash Compactor @ 1500
Pool Heater @ 'name -plate'
DATE:
Spa @ 'name plate,
MECI-6:_�_
Motors 746VA per HP
DATE
Garage Door opener
6 [W3 «\
1) Total
2) First 10 KVA of general load @ 100%
3) Subtract line 2 from 1
4) Multiply IIne 3 @ 40 a
5) Add lines 2 and 4
6) 60/50amp breaker for heat (10000)
7) 40/30amp breaker for heat (5000)
8) Total heat- Add lines 6 and 7
9) Multiply line S @ 65%
10) Add lines 5 and 9
11) Divide line 10 by 240
Summary:
Line 10 is the total KW
Line 11 Is the total Amps
RECEIVED
JUL 10 �1010
Permitting Department
St. Lucie County
i
het
fy.a-44
ot�
!2e 9''�5
(GeneratorSlze Needed)
_ =--- 00 (Breaker size Needed)