Loading...
HomeMy WebLinkAboutEVALUATION REPORTSCANNED BY EXTERIOR RESEARCH & DESIGN, I.I.C. 4 82. Lucie 'Count/ Certificate of Authorization €l9503 \-11T® IN'TYI ER® 353 Christian Street (� Oxford, CT'06478 (203) 262-9245 EVALUATION REPORT CertainTeed Corporation Evaluation Report 3520.03.04-1120 20 Moores Road FL2533-1119,- Malvern, PA 19355 Date of Issuance: 09/19/2005 (610) 651-5847 Revision 20: 09/14/,2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Flintlastic® Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with therequirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 57-page Appendix. Prepared by: t J.M. Nieminen, P.E. Registration No. 59166, Florida DCAANE1983 The facsimile seal appearing was authorized by Robert Nleminen, P.E. on 09/14/2017. This does not serve as an electronically signed document. IFICATION OF INDEPENDENCE: Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. Exterior Research & Design, LLC, d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ��fRINITYIERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: Flintlastic® Modified Bitumen Roof Systems, as produced by Certa(nTeed Corporation, have demonstrated compliance with the following sections of the a Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507.11.2 Physical Properties ASTM D6162 2008 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 1507.11.2 Physical Properties ASTM D6509 2009 3. REFERENCES: Entity ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) Research and Design, I.I.C. s ofAuthortzatlan #9503 Examination FM 4470 FM 4470 FM 4470 FM 4470 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 Physical Properties FM 4470/4474 FM 4470/4474 FM 4470/4474 Physical Properties Physical Properties FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 TAS 117(B), Rupture FM 4470/4474 FM 4470/4474 Physical Properties FM 4470/4474 FM 4470/4474 TAS 117(A) FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470 FM 4470/4474 FM 4470/4474 Reference 3504.06.01-1 3513.08.02 03515.07.03 3519.12.03 3522.07.04 02843.02.05-11 3533.01.06 4674.11.01-1 3535.10.06 3521.07.04-111 02764.09.05-R1 02762.03.05-R1 C7290.01.08 C10080.09.08 C8370.08.08-R1 P6860.06.07-111 C30310.12.09 C30560.03.10 C31420.08.10 C33980.12.10 C33830.02.11 C35500.02.11 C37820.07.12 C37830.07.12 C42110.08.12 C39670.08.12 C42280.08.12 A35880.04.12-111 C44580.07.13 C46090.11.13-A C45620.03.14 C46760.05.14 C47320.03.14-111 CTR-SC8995.10.15 CTR-5C9935.01.16 CTR-SC9920.01.16-R1 CTR-SC10420.01.16 CTR-SC9175.09.16-1 0 EDITION (2017) FBC NON-HVHZ EVALUATION CertainTeed Flintlastic° Modified Bitumen Roof Systems; (610) 651-5847 Date 06/05/2001 08/15/2002 07/22/2003 12/22/2003 07/28/2004 02/10/2005 01/06/2006 03/21/2006 10/31/2006 10/26/2007 12/10/2007 12/10/2007 01/16/2008 09/04/2008 10/05/2009 09/10/2009 12/17/2009 03/18/2010 09/21/2010 12/22/2010 02/08/2011 02/09/2011 07/24/2012 07/26/2012 08/13/2012 08/20/2012 08/20/2012 10/26/2012 07/25/2013 11/20/2013 03/27/2014 06/19/2014 04/01/2015 10/14/2015 01/14/2016 01/20/2016 01/25/2016 09/06/2016 Evaluation Report 3520.03.04-R26 FL2533-R19 Revision 20: 09/14/2017 Page 2 of 6 Kntbt ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) MTI(TST2508) MTI (TST2508) MTI (TST2508) MTI (TST2508) MTI (TST2508) MTI (TST2508) MTI (TST2508) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) UL, LLC. (QUA9625) Research and Design, U.C. a of Authorization #9503 Examination FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4474 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 Physical properties Physical properties Physical properties Physical properties Physical properties Physical properties Physical properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Quality Assurance Reference CTR-SC9175.09.16-1 CTR-SC11590.08.16-RI CTR-SC12255.12.16 CRT-SC15775.17 OE3A2.AM 3WOA4.AM 3WOA2.AM 3WOA3.AM 1Z4A6.AM 3Y8A1.AM 2DSA9.AM 3009502 3008869 3009610 3006025 3012321 3009814 3014502 3015444 3014692 3014751 3018579 3020703 3021759 3022038 3023458 3026128 3024311 3025766 3028410 3026964 3031262 3031199 3032172 3037127 3039848 3046104 3048520 DXO8C4A DX20E3A DX20E3A-001 AX31GBA AX31GSD AX31G8F AX21G8C CTC-032-02-01 CTC-034-02-01 CTC-066-02-01 CTC-067-02-01 CTC-068-02-01 CTC-070-02-01 CTC-071-02-01 CTC-093-02-01 CTC-116-02-01 CTC-183-02-01 CTC-259-02-01 Service Confirmation, R11656 eEDITION (2017) FBC NON-HVHZ EVALUATION CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 �-\J TRINITY { ERD Date 09/06/2016 09/06/2016 12/27/2016 09/13/2017 03/30/1982 03/16/1993 03/17/1993 03/17/1993 09/11/1996 09/30/1996 06/22/1999 12/12/2000 03/19/2001 10/15/2001 12/28/2001 07/29/2002 09/06/2002 04/04/2003 07/11/2003 08/05/2003 08/27/2003 10/09/2003 07/30/2004 06/03/2005 04/05/2006 07/18/2006 08/04/2006 11/01/2006 11/13/2006 02/19/2007 07/25/2007 11/30/2007 12/23/2008 06/12/2009 01/11/2010 12/02/2011 08/13/2013 09/19/2013 03/22/2004 03/22/2004 01/04/2006 08/21/2008 09/05/2008 06/05/2009 01/28/2011 01/16/2008 11/24/2008 08/08/2011 08/08/2011 08/08/2011 08/08/2011 08/08/2011 08/08/2011 04/03/2012 10/04/2013 12/11/2015 Exp.03/09/2020 Evaluation Report 3520.03.04-R20 FL2533-R19 Revision 20: 09/14/2017 Page 3 of 6 \/ TRINITY I ERD 4. PRODUCT DESCRIPTION: This Evaluation Report covers Flintlastic® Modified Bitumen Roof Systems installed in accordance with CertainTeed Corporation published installation instructions and the Limitations / Conditions of Use herein. The following CertainTeed products make up the subject systems. TABLE,I::ROLL-GOODS FOR FLINTLASTIC® MODIFIED BITMEN ROOF SYSTEMS U Type Product Specification Reference Grade Type Base Sheets Flintlastic® SA NailBase`4? ASTM D4601 N/A II Glasbasel Base Sheet — ASTM D4601 N/A II All Weather/Empire- Base ASTM D4601 N/A II FlexiglasTM Base ASTM D4601 N/A II Flintlastic' Base 20 ASTM D4601 N/A II Flintlastic Poly SMS Base Sheet ASTM D4601 N/A II Yosemite® Venting Base ASTM D4897 N/A II Ply Sheets Flintglas® Ply 4 ASTM D2178 N/A IV Flintglas® Premium Ply 6 ASTM D2178 N/A VI Base/Ply Membranes (APP) Flintlastic® APP Base T ASTM D6509 N/A N/A Flintlastic® STA ASTM D6222 S I Flintlastic® STA Plus ASTM D6222 S I Cap Membranes (APP) Flintlastic® STA ASTM D6222 S I Flintlastic® STA Plus ASTM D6222 S I Flintlastic® GTA ASTM D6222 G I Flintlastic® GTA CoolStarTM' ASTM D6222 G I Flintlastic" GTA-FR ASTM D6222 G I Flintlastic® GTA-FR CoolStarTM' ASTM D6222 G I Base/Ply Membranes (SBS) Flintlastic SA P1yBase Black Diamond° Base Sheet Flintlastic SA Mid Ply ASTM D1970 ASTM D1970 ASTM D6163 N/A N/A S N/A N/A I lUltra Glass SA Fli::is ASTM D6163 S I Base 20 ASTM D6163 S I Base 20 T ASTM D6163 S I Ultra Poly SMgBase eet ASTM D6164 S I Cap Membranes (SBS) FR Dual Cap ASTM D6162 G I Flintlastic SA Cap FR ASTM D6163 G I Flintlastic SA Cap FR CoolStarTM' ASTM D6163 G I Flintlastic Cap 30 ASTM D6163 G 1 Flintlastic Cap 30 CoolStarTM' ASTM D6163 G I Flintlastic FR Cap 30 ASTM D6163 G I Flintlastic FR Cap 30 CoolStarTM ASTM D6163 G I Flintlastic FR Cap 30 T ASTM D6163 G I Flintlastic FR Cap 30 T CoolStarTM ASTM D6163 G 1 'Flintlastic SA Cap j ASTM D6164 G I "FIT to lastic SA Cap CoolStar- ASTM D6164 G I astic FR-P ASTM D6164 astic FR-P CoolStarTM ASTM D6164 astic GMS • ASTM D6164 astic GMS CoolStarTm ASTM D6164 G astic GTS RiumFR-P ASTM D6164 G stic GTS CoolStarTM ASTM D6164 G astic GTS-FR ASTM D6164 G stic GTS-FR CoolStarTM ASTM D6164 G stic PremiumFR-P ASTM D6164 Gstic Premium FR-P CoolStarTM ASTM D6164 GUI Research and Design, LLC. Evaluation Report 3520.03.04-R20 eofAuthorizotion#-gso3 6T"EDITION (2017) FBCNON-HVHZ EVALUATION FL2533-1119 CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 651-5847 Revision 20: 09/14/2017 Page 4 of 6 1 � `/ TRINITY � ERD S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ jurisdictions. 5.3 Refer to a current LIL Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16.. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing.,roofdecks, fasteners shall-bein-th eJ existing deck for withdrawal resistancg: —A-qualified esign professional`shall review the dat-for comparison o the minimum regwreme`nts for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the the of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (excep gi of er`s), shall be designed and installed for wind loads in accordance with FBCzChapter- 6 and-reste`d-for fesis anceirLaccor.dance-with.ANSI/SRRI ESA- or Roofing Ag �licat_ion-Standard, TA 1r1;-except-the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. Research and Design, LLC. Evaluation Report 3520.03.04-R20 r ojAuthorizatlon #9s03 6T" EDITION (2017) FBC NON-HVHZ EVALUATION CertainTeed Flintlastic° Modified Bitumen Roof Systems, (610) 651-5847 Revision 20: 09/14/2017 Page 5 of 6 6. INSTALLATION: 7. 8. 9. J�TRINITYIERD 6.1 Flintlastic® Modified Bitumen Roof Systems shall be installed in accordance with CertainTeed Corporation published installation instructions, subject to the Limitations / Conditions of Use herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and, reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 2504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. QUALITY ASSURANCE ENTITY: UL, LLC.—QUA9625; (414) 248-6409, karen.buchmann@us.ul.com - THE 57-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Research and Design, I.I.C. Evaluation Report 3520.03.04-R20 �oJAuthorirotTonl19503 6'EDITION (2017) FBC NON-HVHZ EVALUATION F1.2533-1119 CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 651-5847 Revision 20: 09/14/2017 Page 6 of 6 'J TRINITY I ERD I TA — ; REROOF (TOvt-OFF) SYSTEM TYPE E NON -INSULATED NIECHA I ALY ATTACHED BA � .: , . .-.. : .:. . - .. , .: ASE SHEET, BONDED ROOF.. System Deck Base Sheet Roof Cover (Note 14) MDP No (Note 1) Base Fasteners Attach Ply Cap (psf) SELFADHERING SYSTEMS: :;, - •. . •: . •, . ',�;, - - 9-inch o.c. at min. 3-inch lap and 12-Inch o.c, in W-51 Min.15/32-inch plywood at max 24inch spans Flintlastic SA NailBase Simplex MAXX Cap two (2), equally spaced, staggered center rows; (Optional) SBS- SBS-SA * Stress plates shall be primed with FlintPrime SA 45.0 (ASTM D41) primer. W-52 Min. 15/32-inch plywood at Flintlastic SA NailBase Min. 1-inch long, 12 ga. Simplex 6-inch o.c. at min. 2-inch la and 6-Inch o.c. in P (Optional) SBS- max 24-inch spans P Metal Cap Nails four (4), equally spaced, staggered center rows SA SBS-SA -52.5 Min. 19/32-inch plywood at 32 ga., 1-5/8-inch dia, tin caps 8-inch o.c. at min. 2-inch lap and 8-inch o.c. in W-53 max. 24inch spans Flintlastic SA NailBase with 11 ga. annular ring shank three (3), equally spaced, staggered center (Optional) SBS- SBS-SA -52.5 nails rows SA Min. I plywood at 32 ga.,1-5/8-inch dia. tin caps 8-inch o.c. at min. 2-inch lap and 8-inch o.c. in W-54 24-inc sp max. 24-inch spans Flintlastic SA NailBase with 11 ga. annular ring shank three (3), equally spaced, staggered center (Optional) SBS- SBS-SA -60.0 nails rows 8-inch o.c. at min, 3-inch lap and 8-inch o.c. In W-55 Min. 15/32-inch plywood at max 24-inch spans Flintlastic SA NailBase Simplex MAXX Cap three (3), equally spaced, staggered center (Optional) SBS- SBS-SA rows; Stress plates shall be primed with SA -67.5 FlintPrime (ASTM D41) primer. W-56 t ffMm. 19/32-inch plywood, at J:,;- :- . max 24-inch spans Flintlastic SA NailBase 32 ga.,1-5/8 inch dia. tin caps with it ga. annular ring shank (Optional) SBS- ) SA SBS-SA 75.0 6-inch o.c. at min. 2-inch lap and 6-inch o_c. in — four (4), equally spaced, staggered center rows r nails Cap nails: 1-inch diameter, W 57 Min.15/32-inch plywood at Flintlastic SA NailBase 0.032-inch thick metal cap with 7-inch o.c, at min. 4-inch laps and 7-inch o.c. in (Optional) SBS- max 24-inch spans 0.120" shank diameter, annular five (5), equally spaced, staggered center rows SA SBS-SA -75.0 ring shank nails W-58 Min. 19/32-inch plywood at Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank o.c. at min. 2-inch lap and 4-inch in (Optional) SBS- max 24-inch spans nails four ( four (4), equally spaced, staggered centerr rows SA SBS-SA -105.0 ;HYBRID SYSTEMS .' �.•.. s;. t:. .. • � . VV-59 Min.19/32-Inch exterior grade g Glasbase; Plexiglas; Flintlastic Base as All Weather Empire / P 32 ga., 1-5/8-inch dia. tin caps with it ga. annular ring shank 9-inch o.c. at 4-inch lap and 12 Inch o c. In two SBS-AA SBS TA plywood at max 24-inch spans Base; Poly SMS Base; Ultra Poly nails (2), equally spaced, staggered center rows SBS-SA-H or APP-TA -45.0* SMS Base Glasbase; Flexiglas; Flintlastic W-60 Min. 15/32-inch plywood at Base 20; All Weather / Empire Min. 1-inch long, 12 ga. Simplex 6-inch o.c. at 3-inch lap and 6-inch o.c, in four SBS-AA, SBS-TA max 24-inch spans Base; Poly SMS Base; Ultra Poly Metal Cap Nails (4), equally spaced, staggered center rows SBS-SA H or APP-TA 52.5 SMS Base Exterior Research and Design, I.I.C. d/b/a Trinity IERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 CertalnTeed 6' EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report Appendix 1, Page 13 of 57