HomeMy WebLinkAboutPLAN REVIEW FORMSAINT LUCIE COUNTY FIRE DISTRICT �rt�C�UNJ1'fi PLAN REVIEW FORM t 5160 N.W. Milner Drive Port Saint Lucie, FL 34983 Telephone: 772-621-3322 'UIS` Fax: 772-621.3604 Web Address: www.slcfd.com Building Dept. SLC FMO Permit # B-18-194 ion' Project Name Farrell Advantage Storage Building c BLDG Permit,* 1712.-0019 Address 605' Kitterman Road city PSL f Contractor Welsh Construction 'Address 3845 West EAU Gallie Blvd City Melbourne State FL Zip [32934 Telephone (321)751. 7-7383 Architect/Engineer I Frank GReif Telephone (631)'271-4432 Occupancy l'ype Storage Construction Type 111E Square Feet �72,650 i �Occupant Load 151 per pains NumberofStories I— Access Box Required Access Key Switch AFS Permit Required FA Permit Requited FFP'Permit General Notes 1. An electroniccopy of the construction documents submitted on a CD is required. The fiie,formatshall be.pdf only. 2. All revisions, including the electronic copy must be received prior to permitting. 3. The Fire Marshal requires 24 hour notice on all inspections. 4. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. S. Failed inspections require payment of fee prior to rescheduling of further inspections. 6. Penetrations through rated assemblies shall be of properUL design. 'Design criteria shall be submitted with the construction plans. 7. Fire alarm panels shall be located indoors within air conditioned space. 8. Plans and construction are subject to corrections in the field to maintain code compliance.. 9. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 drn design capacity. 10. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit. THE FLORIDA FIRE PREVENTION CODE, 2015 EDITION IS CURRENTLY ENFORCED. BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. See General Notes Above and Required RevisionsBelow 1. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity.Provide a remotetest and inspect appliance equipped with an audible/visual indicator for each HVAC duct smoke detector.. HVAC duct smoke detector(s) shall be tied into the fire alarm system. 2. The Installation orAlteration of Fire Sprinkler, Fire Alarm Systems require a separate review and permit. Page 11 of 11 Reviewed by Tony.lerger Date 7-D6-2018