HomeMy WebLinkAboutBLOWER DOOR TEST FORMPlanning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201 "ED RECEIVED
Fort Pierce, FL 34982 B
Phone: 772-462-2165 Fax: 772-462-6443 St. LX je County '.FEB t 11019
BLOWER DOOR TEST FORM Pe St. uett Department
Clouse Infiltration Test Certification
Prescriptive and Performance Method
a• -L 8 I l 1A Permit #: I$ 0 l o z 2
tractor: Eel a I 16C f
Address: a.+ _j, F L
struction:) New Construction — Complete ( ) Existing —After Addition
louse Infiltration Test Results SLC Climate Zone 2
CFM (50) = 1 3 q_ Test Date: 2 �$ / 19
Volume =
ACH (50) = CFM (50) x 60 / Volume = -S • Mechanical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less k-) Pass ( ) Fail
�BC, Energy
he building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
our in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
lower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Comganv
Company Name: Pro -Duct Services
Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance With Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Martin Klein
License/Certification #: 5061633
Planning & Development Services N
Building & Code Regulation Division
2300 Virginia Ave, Rm 201 RECEIVED
J_ = Fort Fierce, FL 34982
772-462-2165 Fax 772-462-6443 FEB 11 2019
r' FBC ENERGY CONSERVATION CODE pr-itting Department
Duct Sealing Certification �County
Prescriptive and Performance Method
I�g Permit #: 18 01 - O 2'L. ( Lot #:
ictor: �� M ��c I s Address: Z 6 S 1 dyed �'4 DL
�J�' L Ycdn Ft .7'10 RSA
Post Construction Test ❑ Rough -in Test
:e: 2 14 Floor Area (ft2): 2-1t8
ie: A 7' Primary Location of Supply Ductwork
oor Temperature (F): —1 0 Primary Location of Return Ductwork
tdoor Temperature (F): -1 'L
Leakage: x Default ❑ Prop. Leak Free
Pressure: 2- S (Pa)
line Duct Pressure (optional) (Pa)
Press. (Pa) Flow Ring Fan Press Flow (cfm)
1501
Name: Pro -Duct Services
❑ Proposed On =
Results: Vass ❑ Fail `
Total Leakage (cfm): 6 2 0 0
Total Leakage per 100 sgft: 29
CFM25 x 100 divided by the CFA = Duct Leakage CFMI100 sqft.
Address: V it (o, Yr.: Ft , Pl ercz FLY-T Y-
hereby certify that the above Duct Sealing Leakage results demonstrate compliance with 5th Edition FBC Energy Conservation requirements in accordance with
ection R403.2.2.
signature:
jPrintedName: Martin Klein License/Certificate#: 5061633
BUILDING PERFORMANCE INSTITUTE, INC.
107 Hermes Road, Suite 210
Malta, NY 12020
(877) 274-1274
www.bpi.org
Martin Klein
Bo BPI ID#: 5061633
CERTIFIED PROFESSIONAL
sm (SEE REVERSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES)