Loading...
HomeMy WebLinkAboutREVISION�A OFFICR USE ONLY: FILE COPY SCANNED 1 � BY REVISION _ ..._. _ _ PERMIT # � � 10 County— — ---- IO €IN FEE: _ __.-- - RECEIPT# 1. 2. PLANNING & DEVELC BUILDING & CODE RE'i 2300 VERGIM (772) APPLICATION FOR BUI PROJECT LOCATION/SITE ADDRESS: DETAILED DESCRIPTION OF PROJECT REVISIONS: V() '-) 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #:G ST. LUCIE COUNTY CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: Pro t 'STATE: ZIP: PHONE (DAYTIME): ✓ FAX: 4. OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE: WO CAAJA;C>6i 5. ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCG 9/23/09 Revised 04/26/2010 RECEIVED OCT 0 5 ?tq Permitting Oep�rtment St, Lucie Cpunh, ZIP: FAX: FAX: KEG �MPOE ST. LUCIEICOUNTY BUILDI� DIVISION REVIEWED FOR COMPLIANCE REVIEWED isba ON -do glis 34dW 39 -flIM (9 15o W 11Wd3d_ ONv SNV-1d 90C NO ld3 STRUCTURAL NOTES: All reinforcing steel shall be high strength billet steel and shall conform to ASTM A-615 grade 60 specifications. Lap continuous reinforcing 48 bar diameters or 30" in beams and in slabs. Lap bottom steel over supports and top steel at midspan. Hook discontinuous ends of all top bars. Reinforcing steel shall have a minimum of 1" concrete cover, or as follows: BOTTOM TOP SIDES Beams: 11/2" 11/2" 11/2" Slab on Grade: 1 I/2" 1" _ Structural Poured: 3/4" 3/4" Poured Walls: _ _ 3/4" Slabs exposed to the weather 3/4" 1" Reinforcing steel shall be detailed and fabricated in accordance with the "Manual of Standard Practice of Detailing Reinforcing Concrete Structures" and the current "ACI Building Code 318' All structural steel shall conform to current ASTM Specification A-36 All wood in contact with masonry shall be pressure treated or approved seperating material. All dimensions shall be verified in field by the contractor. If there are any discrepancies the Architect or Engineer shall be notified before proceeding. No slump over 5" shall be permitted for any structural concrete without the Architect or Engineer approval. All Design and Construction shall be inaccordance with the current American Concrete Institute (ACI). and the American Institute of Steel Construction (RISC), The Florida Building Code and all applicable local codes. Structural Concrete shall attain a minimum ultimate compressive strength (Fe') in 28 days as follows: Column Footing and Wall Footing: 3000 .s.i. Column and walls from foundation to roof: see column schedule. All other concrete: 3000 p.s.i. Footing sizes and reinforcing are based on allowable soil bearing capacity of 2000 p.s.i. All footings shall bear in virgin soil. If this is not the case, the Architect or Engineer shall be notified before proceeding with the work. Timber (Heavy Timber Construction) (a) Truss manufacturer shall submit a signed and sealed shop drawings by a registered Engineer. (b) Wood rafters to have a Stress Grade of Fb=1200 p.s.i. (c) Roof members should be secured to the beams or other structural components with hurricane anchors for wind uplift. All wood members shall have a minimum fiber stress in bending of 1200 p.s.i. with 1/360 max. deflection. All bolted connections shall be 1/2" Cadmium plated or better. Lag bolts to be used only in shear connections with minimum 4" threaded penetration past steel plate. Lag bolted conditions shall be drill tapped no larger than the internal thread diameter and shall not be hammer driven. Under Girder Trusses provide equal number of studs as girder plys at frame bearing locations GENERAL REQUIREMENTS All work to be as per the current edition of the Florida Building Code and meet or exceed all applicable local requirements. General contractor is responsible for all labor, materials, utilities, testing, waste removal, storage, securing of site, accomodation, transport/freight, and all other cost related to the completion of this project., unless explicitly identified here. Owner is responsible for all municipal related charges such as impact fees, and water connection, except building permit fees, which are to be included in the construction bid. General contractor to check all drawings for errors and ommissions and bring them to the attention of the architect prior to starting any work, or ordering any materials of the respective division of work. If such errors and ommissions are not reported in writingto the architect, any resulting damages or costs shall be born entirely by the general contractor. Architect is not responsible for the contractors method or means of construction. General contractor is to keep the site in a clean and safe state through out the course of construction. On building turnover, general contractor to clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and standard practice. All plans and drawings are not considered complete until they have been reviewed and approved by the St. Lucie County Building Department and the building permit has been issued. EXTERIOR CEILING & SOFFIT NOTE 7/8" Stucco finish over 3/8" high ribbed gale. wire lath fastened to framing members with No. 11 guage nails with 1 3/4" embed. with 3/8" dia. head 6"o.c. max. edges to be tied and nailed at 9"o.c. Install one layer of 15# felt to framing prior to installing ribbed lath INTERIOR WALL FRAMING NOTE Interior non bearing walls to be 2 x 4 studs 24"o.c. Spruce, Pine, Fir (SPF) #3 Grade lumber or better or metal studs (25 Ga.) Crimper may be used in lieu of screws. GENERAL ROOFING NOTES Roofing to be composed of and attached to pre manufactured wood muses as follows: Felt underlayment (thin. ASTM 0 226 Type H) with 4" min. side and end laps, fasten with coorosion resistant annular ring shank nails at 6"o.c. in laps and in staggered rows spaced 12"o.c. infield. If roof pitch is < 4/12 install (2) layers 15# felt. If roof pitch is 4/12or greater, install (1) layer 30# felt. 5/8" cAx. sheathing or equal installed with staggered joints & GI clips, nailed to trusses with 8d corrosion resistant annular ring shank nails spaced max. 6"o.c. throughout, except max. 4"o.c. at gable ends. All roof trusses areto be pre -manufactured assemblies provided by a licensed wood truss fabricator with seperate drawings and data prepared for actual project conditions by a Florida re g stered professional engineer certified for truss design. Any deviation from the proposed plans as shown regarding placement or bearing shall be brought to the agention of the truss eng Weer prior to fabrication of the trusses, The truss manufacturer's ceRtfied or shall govern after fabrication. The handling, erection, and fixing of wood trusses shall be in accordance with the specifications contained on the certified mfgr's. drawings and data. All engineered headers and truss hangers to be provided by the truss manufacturer. Splitting or cracking of structural components due to installation of hardware is not permitted. Unless otherwise noted, the installation of specified hardware shall conform to the truss manufacturers installation instructions and standard practice. BUCK ATTACHMENT NOTES AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH TO BLOCK WITH 1/4" DIA. TAPCONS INTO C.B.S. SET AT 6" FROM CORNERS AND AT 12"o.c. MAX. AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS OR "T" NAILS" 4" FROM ENDS AND 12"o.c. USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION SHEATHING NAILING NOTES Nailine Pattern Zone 1: 8d at 6"o.c. field & 4"o.c. edges Zone 2: 8d at 4"o.c. edges & field Zone 3: 8d at 4"o.c. edges & field Pneumatic Nails Pneumatic or mechanicaly driven nails will be accepted under the following conditions: Min. nails size 8d or larger ring shank with Min. shank diameter:.113 Min. Length: 2" Min. Head Diameter:.280 Full Round Min. Ring Diameter .012 over shank dia. Min. 16 to 20 Rings per Inch Note Gun nails shall be permitted as an acceptable fastener from any manufacturer Wood screws meeting the same size requirement may be used in lieu of nails without comment Nailine Schedule ROOF & FLOOR DIAGRAM Use sheathing with #8 gun nails at 6"o.c at supported panel edges and #8 gun nails at 6"o.c. at intermediate supports. ROOF SHEATHING TO GABLE END FRAME Use #8 gun nails at 4"o.c. EXTERIOR SHEATHING Use #8 gun nails at 4"o.c. at panel edges and #8 gun nails at 4"o.c. at panel top and bottom and 6"o.c. in field THRESHOLD NOTE At egress door (see floor plan) the max. hgth. of the threshold shall be 1/2" 6" C.M.U. WITH CELLS FILLED I GROUT & (1) #5 VERT. .EL P.T. 2 x 6 AT (3) SIDES OF OPENING, FASTEN TO BLOCK AS NOTED. DOOR SIDES 1/2" x 6" REDHEADS WITH MIN. 2" x 1/8" WASHER 12" FROM ENDS AND 16"o.c. MAX. DOOR HEAD 1/4" x 2 3/4" TAPCONS STAGGERED 24o.c. Garage Door Buck Detail Connector Schedule Bearing Truss Connector Connector Tnlss Point Uplift ID Qnty. Uplift Fasteners 1 2472 (1) 5/8" ATR with 12" min. .a01 MGT 1 3965# embedment and (22) lOd 13 3134 - P1-` to girder. Drill and epoxy ATR in bond beam. BOS 17 1166 HETA16 1 1810# (10) Ind x 1 1/2" 8 1152 2 Ply COl 5 1764 HHETAI6 1 2235# (10) 10d x 1 1/2" 2 986 HETA16 1 1810# (10) lostx 11/2" 2 Ply 2 299 HETA16 1 1810# (10) 1Odx 1 1/2" C04 1 Ply 13 1848 HHETAI6 1 2235# (10) Ind 1 1/2" 8 798 HETA16 1 1810# (10) 1Odx 1 1/2" 8 2477 (1) 5/8" ATR with 12" min. DOI MGT 1 3965# embedment and (22) 1Od 2 2161 2 Ply to girder. Drill and epoxy ATR in bond beam. FGl 6 1469 HHETAI6 1 2235# (to) lodx 1 12" 2 Ply 4 1007 HETA16 1 I8104 (10) 10dx 1 1/2" All other trusses ALL <1000 MTS18 1 1000# (14) 10d x 1 1/2" to Frame All other trusses ALL <1810 RETA20 1 1810# (9) 10d x 1 1/2" to CBS Supporting (4) lOd Valley Framing <250# VTCR 1 370# ass (3) 10d x 1 1/2" Trusses T Connector Notes: Do not substitute connectors Do not sheath trusses before all straps are in place Attach valley trusses and piggy back trusses, if present, to main trusses per truss manufacturer drawing. Truss to truss connection by truss company, installed per manufacturers specs. Lateral forces perpendicular and parallel to wall has been considered (less than 300 p.l.f.) Contractor to appprove temporary bracing to prevent toppling of trusses, see MEN. Other specs, if different from above, have priority. A.T.R. = All Treaded Rod Drill and Epoxy Set all A.T.R. Use either "Hilti" C-100 or Simpson Epoxy Tie Epoxy 3/8" continuous bead of caulk (back bedding) behind buck to prevent liquid passage set flange in continuous bead of caulk across the entire face of buck i U � y Oa °ova c= o �pO d N PU_1� a stucco finish J/ perimeter caulk J/ / Attach p.t. bucks J with 8d coil nails al. 12"o.c. Typ. Alum. window_ jamb or sliding glass doorjamb CBS e Min. 1 1/4" embedment a at windows and min. 1 1/2" embedment at Id a a ° ° A. gl. doors 1/4" max. struct. shim caulk _attach as per manufacturers product approvals NOTE: Method of attachment and Gunable sealants shall comply with waterproofing procedures are the ASTM C 920 Class 25 grade or same at poured leonerete sill. greater for proper joint expansion and contraction Coat Bucks with DryLock Waterproofing after they have been installed and Chaulked 1 Window & Door Flashing Detail at CBS Wall Includes Buck Attg7hment Method comer bars at beam (outside only) (2) corner bars at footing (min.) - vert. dowel lapped with wall reinforcing, all laps 25" (min.) in grout filled cell all comer bars to be the same size, number, and spacing as horizontial bars in footing, beams, and walls Corner Reinforcing Detail 2 x 4 bottom cord bracing FAM 10'-0" Bottom Cord Lateral Bracing Safe Load Table Notes 1. All values based on minimum 4" nominal bearing. Exception: Safe loads for unfilled U lintels must be reduced by 20% if bearing length is less than 6 1/2". 2. N.R. = Not Rated 3. Safe loads are superimposeda] a loads. allowable 1 4. One #7 rebar may be substituted for two #5 rebar in 8 inch U lintels only. 5. All safe loads in units of pounds per littler foot. 6. All safe loads are based on simply supported span. 7. Safe load ratings based on rational design analysis per ACI 318 and ACI 530. MSoreber atop li,"aa �, guru ry of mbv t bottom Mlintd .... cevry Y i-filled Bmm w w run I CM. V7 I P`�" 8F16-lB/1T ast tt� "e 11td 5/8' Y5 rebar et boom em Inel Pebarat Pop' offntelcmv h,i,m Lintel Type Designation Cast Crete Lintel Schedule Installation Notes 1. Installation of U lintels must comply with architectural and/or structural drawings. 2. U lintels can be field cut to the required length. 3. Cast in place concrete may be provided in composite U lintel to lieu of concrete masonry un its. s. 4. The exterior surface of U lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 5. Concrete masonry units used in composite U lintel shall be laid in a running bond. 6. Shore composite lintels as required. 7. U lintels are manufactured with a 5 1/2" long notch at both ends to accomodate vertical cell reinforcing and grout. Composite U Lintel Materials 1. Grout per ASTM C476 fg-3000 psi with maximum 3/8 inch aggregate and 8 to 11 inch slump. 2. Rebar per ASTM A615 Grade 60 3. Concrete masonry units (CMU) per ASTM C90 with minimum net area compressive strength = 1900 psi 4. Mortar per ASTM C270 Type M or S All Rebar to be #5 Grade 60 min. MARK LENGTH OF LINTEL ALLOWABLE GRAVITY LOAD APPLIED GRAVITY LOAD ALLOWABLE UPLIFT LOAD APPLIED UPLIFT LOAD BEAM SPECS. L-1 3'-8" 8974 550 4853 358 81724-113/1T 1,2 2'-4" 8974 125 5591 150 8F24-1B/lT Ira 7-6" 3486 911 2084 775 8F24-1B/lT L-4 4'-6" 8672 2081 4292 2161 8F24-1B/1T L-5 4'-8" 8060 1062 3277 483 8RF22-1B/1T L-6 13'-8" 1697 710 1434 598 024-113/2T L-7 17-4" 1849 607 1268 697 8F30-lB/1T 1366 200 798 80 8F16-1B/lT L-9 12'-8" 1 1075 700 1 770 170 8F16-1B/2T Mim. Beam depths shown, beams may be increased without comment At Lintels over 24" deep provide (1) #3 vertical rebar at 24"o.c. along length of lintel Alum. window frame 3/8" continuous bead of caulk (back bedding) behind_ - shim to prevent liquid passage 1/4" struct. shim set flange in continuous bead of caulk across the entire face of buck perimeter caulk stucco finish Gunable sealants shall comply with F a ASTM C 920 Class 25 grade or greater for proper joint expansion and contraction precast cone. sill v� corrosive resistant Tapcon concrete srews installed as specified in window manufacturers product approval 0 window sill Typical Precast Cone. Sill Detail PRODUCT APPROVAL Approval Product Model Number Manufacturer Glass Attachment Method Building Rated Product Rated Number Type Design Pressures Design Pressures S.H. Windows Head: 3" max. from comers & (1) at center. Iambs: FL# 17499.3 U-Factor: 0.55 ] 85 SH MI Windows 3NN. 3" max. from comers & (2) equals aced at each side of meeting rail. Use 3/16"Tapcon wit 1 1/4" embedment +38.7 -50.5 +/- 55.0 S.H.G.C.:.22 N• into concrete S.H. Windows Head: 2" max. from comers & (1) at center. Iambs: FL# 17499.1 U-Factor: 0.55 185 SH Mt windows Impact 2" max. from comets & (2) equal spaced at each side of meeting rail. Use 3/16" Tapcon with 1 1/4" embedment +38.7 -50.5 +/- 55.0 S.H.G.C.:.22 into concrete Fixed Window Head: 6" max. from corners & 18" max. o.c. all sides FL# 15349.1 U-Factor: 0.55 185 SH MI Windows 3116" Use 3/16" Tapcon with ] I/4" embedment +40.5 -54.0 +/- 60.0 S.H.G.C.:.22 N' into concrete Fixed Window Head: 3" max. from comers & 13 1/2" max. O.G. all sides FL# 15349.3 U-Factor: 0.55 185 SH MI Windows Impact Use 3/16" Tapcon with 1 1/4" embedment +40.5 -54.0 +/_ 55.0 S.H.G.C.:.22 into concrete Head: 6" max. from comers, (2) each side of meeting rail 3/16" 17"o.c. max. at Head and Sill. Iambs: 6" from corners and FL# 15332.2 Sliding Glass Dr. Series 420 MI Doors ANNr 17"o.c. max. Use 3/16" IEW tapcons with 1 1/4" +34.4 -37.8 +/- 40.0 embedment into concrete FL# 15353.2 Mullion 5764 MI Windows Nr A Two 1/4" Tapcons per clip with 1 114" embedment into 2 1/2 distance. +38.7 -50.5 +/- 53.3 concrete with edge 6" from comers & 14.5"o.c. at Iambs. Head and Sill 3" and FL#: 15037.4 Swing Doors Fiberglass Therma-Tin N.A. 7" from centerline. Use 1/4" Tapcon with 1 1/4" embedment +38.7 -42.1 +/- 50.0 into concrete FL#: 8248.7 Garage Door g Mode] 8000 Wayne Dalton Y N.A. Jamb Bracket Angle (3) total 5116" x 1 5/8" lag screws. (7) total + 20.4 -22.7 +30.0 -33.5 Bracket 8'-O" height (1) 5/ 16" x 1 5/8" lag screws per bracket. Approval Product Model Number Manufacturer Attachment Method Building Rated Product Rated Design Pressures Design Pressures FL#: 24221.9 Roofing 26 Ga. 5 V Crimp Dynamic Metals #10-1 1/2" coorosion resistant fastener with sealing washers 8"o.c. along corners & 16"o.c. in main field. Typ. at overlap & middle rib -243.5 FL#: 12856.2 Storm Panels 2S Ga. Steel Town &Country 1/4" All Points Solid Set Anchor x 7/8" embedment. 2" min. edge distance +40.5 -54.0 +/-54.0 12"o.c. Top &Bottom 1 1/4" long No. I 1 Gauge Galy. Roofing Nail with frill round head to penetrate FL#: 13192 Siding Lap Siding James Hardie furring 1" 5 3/8"o.c. Vertical and 8"o.c. Horiz. with 3/8" min. edge distance and a -42.1 -92.0 max. 2" edge distance i✓1 00 ii8 � aM W S-I W z so bt -0 w W W °° p a�� Q O W UQ.A O w � O O � M (~ W F-, 0 . ~ tC00 � x zN G� W r- V) M 04 O w W U I_, 'd z ZI •ZI W N � � Q w � � U O ICi+ NNED U 1' at. Lucie Coin/ date revision 9/26/18 Roofing FL. # drawn s.l. checked st. date 6/26/18 scale as noted job number 18034 sheet A-4