Loading...
HomeMy WebLinkAboutENGINEERINGt ISCANNED ENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fax: (866) 784-8550 St. Lucie County lvmv.floridaengineering indtesting.com 250 S.W. UP Avenue ZILE CC)pDy Pompano Beach, FL 33069 DATE: 7/11/18 JOB ORDER #: 18-2863 CLIENT: All Area Roofing ADDRESS: 3921 S. US Highway 1 Fort Pierce, FL 34982 PROJECT: Daum Residence Sloped Tile Roof Deck ADDRESS: 9519 Shadow Lane Fort Pierce, FL 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS Project Information: Mean Roof Height = 10' Length = 87' Width = 73' Parapet Wall: N/A Design Calculations: Exposure: C Basic/Ultimate Wind Speed: V„1t=170 mph Category: II Nominal Wind Speed: V.d=V,it*40.6 Slope: 5/12 (asd = allowable strength design) Residential KZ = 0.85, Kzt =1.0, Kd = 0.85 Velocity Pressure: q = 0.00256*K,-KztKdV2 Velocity Pressure (,,It): q=0.00256(0.85)(1.0)(0.85)(170)2] = 53.45 psf Velocity Pressure (.d): q=0.00256(0.85)(1.0)(0.85)(170*40.6)2] = 32.07 psf Width of Pressure Coefficient: 0.1(73) = 7.3' 0.4(10') = 4.0' } use: 4'0" Effective Wind Area: <10ft2 For hip roofs with a roof slope of 25 degrees or less, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: 1) GCP1 = -0.9 2) GCP2 = -1.7 3) GCP3 = -2.6 Internal Pressure Coefficient: 1) GCPi = 0.18 FILE Copy Vf Q Quality , A�I.Jm trance w Page 2, 7/11/18, Job Order #18-2&._, -All Area Roofing Daum Residence - Sloped Tile Roof Deck 9519 Shadow Lane; Fort Pierce, FL: Design Pressures Based on Vasd: 1) Field P1 = 32.07*[(-0.9) — (0.18)] _ -34.6 psf 2) Perimeter P2 = 32.07*[(-1.7) — (0.18)] _ -60.3 psf 3) Corners P3 = 32.07*[(-2.6) — (0.18)] _ -89.2 psf Attachment Reouirements Per RAS 127 (Entegra Plantation Flat Tile): FLO A Tile System: Moment Based Aerodynamic Multiplier: 0.289 ft3 (Direct Deck Application - Table 1 Restoring moment due to gravity: Mg = 7.52 ft-lbf (Table 2) Attachment resistance expressed as a moment: Mf= 51 ft-lbf Polyset AH-160 Foam Set (Table 4, Single Medium Paddy 30g) 1) Field : Mri = (34.6*0.289) = 7.52 ft. lb = 2.5 ft. lb. < 51 ft. lb = PASS 2) Perimeter : Mr2 = (60.3*0.289) — 7.52 ft. lb = 9.9 ft. lb. < 51 ft. lb = PASS 3) Corners : Mr3 = (89.2*0.289) — 7.52 ft. lb =18.3 ft. lb. < 51 ft. lb = PASS System is acceptable as approved with single medium paddy (30g) placement of the Polyset AH-160 Foam Ahesive by ICP Ahdesives and Sealants based on the requirements of Florida Product Approval # FL7804-R10. Notes: Corners and perimeter area dimension shall not be less than a = 4'0" Contractor to verify 'that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. Wind load calculations based on ASCE-7, 2017 FBC, and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely, ZC No. 48202 Mark A. Mess; P.E. Florida Engir* ' & cTVWjr(W Inc;`� Florida Reg.-�.%20?� Certificate of