HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING TILESFlo rida Building Code Online SCANNED Page 1 of 2
St. Lude County
lit
BCIS Home I Log In, User Registration Hot Topics I Submit Surcharge Slats & Facts Publications I FBC.stafr I BCIS Site Map I Links I Search
Product Approval COPY
USER: Public User FILE
Product Aporoval Menu > Product or Anptication Search > Application List > Application Detail t, I
FL # FL7804-R10
Application Type Revision
Code Version 2017
Application Status Approved
OONCi=ACED FASTENERS tNERS O ,4 i I rtC; iLr V T 3
ARE THE RESPOj 151BILITY OF THE
Comments e- f^afu7gC;TOR Cap j�COr�D
Archived (]
Product Manufacturer Entegra Roof Tile, LLC
1289 NE 9th Avenue
THESE PLANS AND ALL PROPOSED WORK
Address/Phone/Email
Okeechobee, FL 34972
ANY
515-6933
thomas
REQUIRED BY FIELD INSPECTORS THAT
jemmett@boral.com
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
Authorized Signature Thomas Jemmett
thomas.jemmett@boral.com
Technical Representative
Address/Phone/Email ST. LUCIE COUNTY BUILDING DIVISION
REVIEWED FOR COMPLIANCE
Quality Assurance Representative REVIEWED BY
Address/Phone/Email DATE
PLANS AND PERMIT MUST BE KEPT ON JOB
Category Roofing SITE OR NO INSPECTION(S) WILL BE MADE
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
i) Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 11/02/2018
Validated By John W. Knezevich, PE
Li Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
�a�,iSee"`r`�'�0 FASTF�Eci� OR Aift'wH1RE�iTS
ARE THE RESPONSIBILITY OF THE
COiVTRACTOR OR RECORD
Equivalence of Product Standards
Certified By
FL7804 R10 COI 2016 01 COI Nieminen.odf
Standard
ASTM C1492
FRSA/TRI April 2012
SSTD 11
TAS 100
TAS 101
TAS 102
TAS 102(A)
TAS 112
Year
2003
2012
1997
1995
1995
1995
1995
1995
://floridabuilding.org/Dr/i)r am) dtl.asbx?Daram=wGEVXOwtDauovOiOHI%2bAMias... 3/14/2018
Building Code Online
Page 2 of 2
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Crrrnrnary of 113-1 rfc
Method 1 Option D
10/17/2017
10/19/2017
10/22/2017
12/12/2017
FL #
Model, Number or Name
Description
7804.1
Entegra Concrete Roof Tiles (HVHZ
Concrete Roof Tile
jurisdictions)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL7804 R10 II 2017 10 FINAL ER ENTEGRA FL7804-
RIO HVHZ.DdF
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use. Refer to ER
Evaluation Reports
Section 6 for Installation.
FL7804 RIO AE 2017 10 FINAL ER ENTEGRA FL7804-
R10 HVHZ.Ddf
Created by Independent Third Party: Yes
7804.2
Entegra Concrete Roof Tiles (non-
Concrete Roof Tile
HVHZ jurisdictions)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL7804 RIO 11 2017 10 FINAL ER ENTEGRA FL7804-
R10 NON-HVHZ.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use. Refer to ER
Evaluation Reports
Section 6 for Installation.
FL7804 R10 AE 2017 10 FINAL ER ENTEGRA FL7804-
RIO NON-HVHZ.Ddf
Created by Independent Third Party: Yes
Back Fe.t
Contact Us :: 2601 Blair Stone Road. Tallahassee Fl. 32399 Phone: 850-487-1824
The State of Florida Is an ANEW employer. Coovnoht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do notwantyour e-mail address released in response to a public -records request, do not send
electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
�11
Credit Card
Safe
/floridabuilding.org/nr/fir ann dtl.asnx?naram=wGEVXOwtDauovOiOHI%2bAMlas... 3/14/2019
TRINITY ERD
ALLIATION REPORT
O O F T I L E
Entegra Roof Tile, LLC
1289 NE 9th Avenue
Okeechobee, FL 34972
(602)515-6933
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate ofAuthorizotion N9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203)262-9245
Evaluation Report E39310.11.11-1-R4
FL7804-R10
Date of Issuance: 11/02/2011
Revision 4:10/17/2017
his Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
onstruction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
roducts described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
HVHZI sections noted herein.
Entegra Concrete Roof Tiles (HVHZ jurisdictions)
Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
lerein.
;ONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
eferenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
i,cceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
iroduct changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
eview of this Evaluation Report relative to updated Code requirements with each Code Cycle.
kDVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in
Idvertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
is distributors and shall be available for inspection at the job site at the request of the Building Official.
is Evaluation Report consists of pages 1 through 8.
!pared by:
t J.M. Nieminen, P.E.
Registration No. 59166, Florida DC4ANE1983
The facsimile seal appearing was authorized by Robert Nleminen,
P.E. on 10/17/2017. This does not serve as an electronically signed
document. signed, sealed hardeoples have been transmitted to the
Product Approval Administrator and to the named client
IFICATION OF INDEPENDENCE:
TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
\I TRINITY ERD
1OOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
Property
Standard
Year
1523.6.5.2
Physical Properties
TAS 112
1995
1523.6.5.2
Wind Driven Rain
TAS 100
1995
1523.6.5.2.2
Static Uplift Resistance
TAS 101
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102(A)
1995
3. REFERENCES:
kniint
Examination
Reference
Date
ERD (TST6049)
TAS 101
P39740.02.12
02/21/2012
ATL (TST3782)
Physical Properties
RT0624.05-14
07/03/2014
ATL (TST3782)
Physical Properties
RT0624.04-14
07/07/2014
ATL (TST3782)
Physical Properties
RT1210.02-15
12/17/2015
ATL (TST3782)
Physical Properties
RT1210.03-15
12/17/2015
ATL (TST 3782)
Physical Properties
RT1103.01-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.02-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.03-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.04-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.05-15
11/07/2015
Miami -Dade (CER1592)
HVHZ Compliance
14-0416.12
11/27/2014
Miami -Dade (CER1592)
HVHZ Compliance
15-0721.04
11/05/2015
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.06
02/25/2016
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.07
02/25/2016
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.08
02/25/2016
Tile Roof Institute
TAS 100, TAS 101, 102,102(A)
Membership Confirmation
Current
PRI (QUA9110)
Quality Assurance
Service Confirmation
Exp.11/02/2018
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4
i
Certificate of Authari:ation#9503 6r"EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 I
Entegra Roof Tiles Revision 4:10/17/2017
Page 2 of 8
I
-1 TRINITY I ERD ,
PRODUCT DESCRIPTION:
4.1 1 TA 112, Type 3a (flat -profile) BERMUDA FLAT, PLANTATIONfLAT and! HORizoN,F -AT,
Bermuda Flat
% 17-114"
13"
Horizon Flat
Plantation Flat
Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4
ao/Authoriration#9503 6'"EDITION 12017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 3 of 8
TRINITY I ERD
4.2 TAS 11-2; Type 1a (interlocking, high -profile) BELIA,HIGH "S",
Bella High "S"
4.3 1 TAS 112, Type 1b (interlocking, low -profile) ESTATE "V and HACIENDA
Holes —I
Estate "S" Hacienda
4.3 1 TAS 112, Type 2a (non -interlocking, high -profile) GALENA SPANISH "S" andi-REGAL
17"
Galena Spanish "S"
Exterior Research and Design, LLC.
Certificate ofAuthorization #9503
10"
C"EDITION (2017) FBCHVHZEVALUATION
Entegra Roof Tiles
Evaluation Report E39310.11.11-1-R4
FL7804-R10
Revision 4:10/17/2017
Page 4 of 8
��TRINITYJERD
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements.
5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for
fire rating of this product.
5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112, Appendix W.
5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment
products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof
assemblies in FBC HVHZ jurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule
61G20-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of RAS 118,
RAS 119 or RAS 120, as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in
accordance with Roofing Application Standard RAS 127-11 using the data outlined herein.
TABLE 1: AERODYNAMIC MULTIPLIERS -91. (FT)
Tile Batten Application Direct -Deck Application
Bermuda Flat 0.189 0.205
Plantation Flat 0,267 0.289
Horizon Flat 0.305 0.330
Bella High "S" 0.349 0.378
Estate "S" 0.267 0.289
Hacienda 0.267 0.289
Galena Spanish "S" N/A 0.235
Regal 0.287 0.311
TABLE 2: RESTORING MOMENT DUE TO GRAVITY- M. (FT-LBF)
Tile
Roof Slope (0)
2:12<0<3:12
3:12<0<4:12
4:12<0<5:12
5:1250<6:12
6:12<A<7:12
02:7:12
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Bermuda Flat
5.22
6.43
5.17
6.37
5.09
6.27
4.98
6.15
4.86
6.00
4.72
5.83
Plantation Flat
7.22
7.91
6.85
7.79
6.75
7.67
6.61
7.52
6.44
7.32
6.26
7.04
Horizon
7.60
8.32
7.52
8.24
7.41
8.12
7.26
7.95
7.09
7.76
6.89
7.55
Bella High "S"
6.19
6.89
6.11
6.80
5.99
6.67
5.85
6.51
5.68
6.33
5.50
6.13
Estate "S"
6.14
6.84
5.91
6.74
5.82
6.64
5.70
6.50
5.56
6.33
5.40
6.14
Hacienda
5.92
6.80
5.92
6.80
5.82
6.69
5.70
6.55
5.56
6.39
5.41
6.22
Galena Spanish "S"
N/A
6.20
N/A
6.13
N/A
6.03
N/A
5.89
N/A
5.74
N/A
5.57
Regal
7.77
8.34
7.77
8.34
7.65
8.20
7.49
8.03
7.30
7.83
7.10
7.61
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report E39310.11.11-1-R4
6r" EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4.10/17/2017
Page 5 of 8
�I TRINITY ERD
TABLE 3A: ATTACHMENT. RESISTANCE EXP.RESSED•AS A MOMENT-MF#,T-LBF)
Ii MECHANICALLY ATTACHED SYSTEMS
i
Tile
Fastener
Direct -Deck
(min.15/32"
plywood)
Direct -Deck
(min.19/32"
plywood)
Battens
Type
#
Size
Shank
Clip
Nail
One (1)
10d
Smooth or Screw
N/A
7.3
9.8
4.9
Nail
Two (2)
10d
Smooth or Screw
N/A
14.0
18.8
7.4
Nail
One (1)
10d
Smooth or Screw
Eave
19.0
19.0
22.1
Nail
One (1)
10d
Smooth or Screw
Field
24.3
24.3
24.2
Bermuda Flat,
Nail
Two (2)
10d
Smooth or Screw
Eave
31.9
31.9
32.2
Plantation Fiat or
Nail
Two (2)
lod
Smooth or Screw
Field
35.5
35.5
34.8
Horizon
Nail
Two (2)
10d
Ring
N/A
30.9
38.1
17.2
Nail'
Two (2)'
10d'
Ring'
N/A
50.3'
65.5'
48.3'
Screw
One (1)
#8
N/A
N/A
30.8
30.9
18.2
Screw
Two (2)
48
N/A
N/A
51.7
51.7
24.4
' Installation with a 4-inch tile headlap and fasteners located min. 2Y,-inch from head of tile.
Nail
One (1)'
lod
Smooth or Screw
N/A
8.8'
11.8'
4.1'
Nail
Two (2)
10d
Smooth or Screw
N/A
16.4
21.9
7.1
Nail
One (1)'
10d
Smooth or Screw
Eave
19.0'
19.0'
22.1'
Nail
One (1)'
lod
Smooth or Screw
Field
24.3'
24.3'
24.2'
Nail
Two (2)
10d
Smooth or Screw
Eave
31.9
31.9
32.2
"S"
Nail
Two (2)
10d
Smooth or Screw
Field
35.5
35.5
34.8
Estate or Hacienda
Nall
Two (2)
10d
Ring
N/A
27.6
37.4
28.8
Nail'
Two (2)'
10d'
Ring'
N/A
43.0'
67.5'
S0.9'
Screw
One (1)'
N8
N/A
N/A
25.8'
25.8'
22.9'
Screw
Two (2)
48
N/A
N/A
47.1
47.1
49.1
' Installation with a 4-inch tile headlap and fasteners located min. 2%-inch from head of tile.
' For one (1) fastener Installations, utilize hole that is approximately 4%-inch from the interlocking edge.
Nall
One (1)
10d
Smooth or Screw
N/A
5.1
6.8
2.8
I
Nail
Two (2)
10d
Smooth or Screw
N/A
6.9
9.2
7.3
Nail
One (1)
lod
Smooth or Screw
Field
23.1
23.1
19.0
Nail
One (1)
lod
Smooth or Screw
Eave
29.3
29.3
24.0
Nail
Two (2)
lod
Smooth or Screw
Field
27.6
27.6
38.6
Bella High "S", Galena
Spanish "S" or Regal
Nail
Two (2)
lod
Smooth or Screw
Eave
38.1
38.1
41.8
Nail
Two (2)
10d
Ring
N/A
28.6
41.2
19.4
Nail'
Two (2)'
10d'
Ring'
N/A
33.1'
48.1'
50.9'
Screw
One (1)
#8
N/A
N/A
20,7
20.7
18.1
Screw
Two (2)
48
N/A
N/A
43.2
43.2
29.8
' Installation with a 4-inch tile headlap and fasteners located min. 2Y-inch from head of tile.
Exterior Research and Design, I.I.C. Evaluation Report E39330.11.11-1-R4
Certificate of Authorization #9503 6'" EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 6 of 8
TRINITY I ERD
TABLE 4: ATTACHMENT RESISTANCE EXPRESSED'AS A MOMENT— MP(FT-LBF)
MORTAR AND ADHESIVE -SET SYSTEMS
Note from Entegra Roof Tile, LLC.: The performance data listed in Table 4 ore based on the, respective. adhesive,manufacturers' test,
reports and: Miami -Dade NOAs. Entegra Roof Tile, LLC. relies upon the adhesive manufacturers to -provide these values for. our inclusion
In this FBC HVHZ Evaluation Report. Please consult the individual adhesive, manufacturer. for information .on product :approvals,
limitations, revisions or other information for determining wind load and overturning moment performance.
Tile Adhesive
Tile
Product
Product Approval
Placement
Mf (ft-lbf)
"TILE BOND'"" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
41
Bermuda
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
73
Flat'
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
52
Plantation
Interdependent (2-paddy)
43
Flat or
Horizon
"Polyset° AH-160" by ICP Adhesives &
NOA 17-0322.03
Independent (medium paddy, ^30 g)
51
Sealants
Independent (large paddy, -45 g)
92
"TILE BOND"' by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
44
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
42
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
44
Estate "S" or
Interdependent (2-paddy)
50
Hacienda
"Polyset® AH-160" by ICP Adhesives &
NOA 17-0322.03
Independent (medium paddy, —30 g)
37
Sealants
independent (large paddy, —54 g)
61
Mortar
Various
Per RAS 120
21
"TILE BOND'"" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
48
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
52
Bella High
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
36
"S", Galena
Interdependent (2-paddy)
30
Spanish "S"
or Regal
"Polyset® AH-160" by ICP Adhesives &
NOA 17-0322.03
Independent (medium paddy, ^30 g)
49
Sealants
Independent (large paddy, —63 g)
94
Mortar
Various
Per RAS 120
25
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein.
and/or
ENTEERA v,:�7
Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4
Certificate ofAutharization #9503 6C'EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4,.10/17/2017
Page 7 of 8
QOTRRINITY ERD
-FL'
and/or
. H a.
n s o n
Labeling: Horizon Flat, Hacienda, Regal
8. BUILDING PERMIT REQUIREMENTS:
i
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS: I
Plant.
Profiles
Okeechobee, FL
Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Ft. Myers, FL
Horizon Flat, Hacienda
Deerfield Beach, FL
Horizon Flat, Hacienda, Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777
- END OF EVALUATION REPORT —
Exterior Research and Design, I.I.C.
Certffcate ofAathori:ation #9503 e" EDITION (2017) FBL HVHz EVALUATION
Entegra Roof Tiles
I
i
Evaluation Report E39310.11.11-1-R4
FL7804-R10
Revision 4:10/1712017
Page 8 of 8