Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING TILESFlo rida Building Code Online SCANNED Page 1 of 2 St. Lude County lit BCIS Home I Log In, User Registration Hot Topics I Submit Surcharge Slats & Facts Publications I FBC.stafr I BCIS Site Map I Links I Search Product Approval COPY USER: Public User FILE Product Aporoval Menu > Product or Anptication Search > Application List > Application Detail t, I FL # FL7804-R10 Application Type Revision Code Version 2017 Application Status Approved OONCi=ACED FASTENERS tNERS O ,4 i I rtC; iLr V T 3 ARE THE RESPOj 151BILITY OF THE Comments e- f^afu7gC;TOR Cap j�COr�D Archived (] Product Manufacturer Entegra Roof Tile, LLC 1289 NE 9th Avenue THESE PLANS AND ALL PROPOSED WORK Address/Phone/Email Okeechobee, FL 34972 ANY 515-6933 thomas REQUIRED BY FIELD INSPECTORS THAT jemmett@boral.com MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. Authorized Signature Thomas Jemmett thomas.jemmett@boral.com Technical Representative Address/Phone/Email ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANCE Quality Assurance Representative REVIEWED BY Address/Phone/Email DATE PLANS AND PERMIT MUST BE KEPT ON JOB Category Roofing SITE OR NO INSPECTION(S) WILL BE MADE Subcategory Roofing Tiles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer i) Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 11/02/2018 Validated By John W. Knezevich, PE Li Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) �a�,iSee"`r`�'�0 FASTF�Eci� OR Aift'wH1RE�iTS ARE THE RESPONSIBILITY OF THE COiVTRACTOR OR RECORD Equivalence of Product Standards Certified By FL7804 R10 COI 2016 01 COI Nieminen.odf Standard ASTM C1492 FRSA/TRI April 2012 SSTD 11 TAS 100 TAS 101 TAS 102 TAS 102(A) TAS 112 Year 2003 2012 1997 1995 1995 1995 1995 1995 ://floridabuilding.org/Dr/i)r am) dtl.asbx?Daram=wGEVXOwtDauovOiOHI%2bAMias... 3/14/2018 Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Crrrnrnary of 113-1 rfc Method 1 Option D 10/17/2017 10/19/2017 10/22/2017 12/12/2017 FL # Model, Number or Name Description 7804.1 Entegra Concrete Roof Tiles (HVHZ Concrete Roof Tile jurisdictions) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL7804 R10 II 2017 10 FINAL ER ENTEGRA FL7804- RIO HVHZ.DdF Approved for use outside HVHZ: No Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use. Refer to ER Evaluation Reports Section 6 for Installation. FL7804 RIO AE 2017 10 FINAL ER ENTEGRA FL7804- R10 HVHZ.Ddf Created by Independent Third Party: Yes 7804.2 Entegra Concrete Roof Tiles (non- Concrete Roof Tile HVHZ jurisdictions) Limits of Use Installation Instructions Approved for use in HVHZ: No FL7804 RIO 11 2017 10 FINAL ER ENTEGRA FL7804- R10 NON-HVHZ.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use. Refer to ER Evaluation Reports Section 6 for Installation. FL7804 R10 AE 2017 10 FINAL ER ENTEGRA FL7804- RIO NON-HVHZ.Ddf Created by Independent Third Party: Yes Back Fe.t Contact Us :: 2601 Blair Stone Road. Tallahassee Fl. 32399 Phone: 850-487-1824 The State of Florida Is an ANEW employer. Coovnoht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do notwantyour e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: �11 Credit Card Safe /floridabuilding.org/nr/fir ann dtl.asnx?naram=wGEVXOwtDauovOiOHI%2bAMlas... 3/14/2019 TRINITY ERD ALLIATION REPORT O O F T I L E Entegra Roof Tile, LLC 1289 NE 9th Avenue Okeechobee, FL 34972 (602)515-6933 EXTERIOR RESEARCH & DESIGN, LLC. Certificate ofAuthorizotion N9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 (203)262-9245 Evaluation Report E39310.11.11-1-R4 FL7804-R10 Date of Issuance: 11/02/2011 Revision 4:10/17/2017 his Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of onstruction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, .E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The roducts described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code HVHZI sections noted herein. Entegra Concrete Roof Tiles (HVHZ jurisdictions) Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted lerein. ;ONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the eferenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. i,cceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the iroduct changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete eview of this Evaluation Report relative to updated Code requirements with each Code Cycle. kDVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in Idvertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or is distributors and shall be available for inspection at the job site at the request of the Building Official. is Evaluation Report consists of pages 1 through 8. !pared by: t J.M. Nieminen, P.E. Registration No. 59166, Florida DC4ANE1983 The facsimile seal appearing was authorized by Robert Nleminen, P.E. on 10/17/2017. This does not serve as an electronically signed document. signed, sealed hardeoples have been transmitted to the Product Approval Administrator and to the named client IFICATION OF INDEPENDENCE: TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. \I TRINITY ERD 1OOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1523.6.5.2 Physical Properties TAS 112 1995 1523.6.5.2 Wind Driven Rain TAS 100 1995 1523.6.5.2.2 Static Uplift Resistance TAS 101 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 1995 3. REFERENCES: kniint Examination Reference Date ERD (TST6049) TAS 101 P39740.02.12 02/21/2012 ATL (TST3782) Physical Properties RT0624.05-14 07/03/2014 ATL (TST3782) Physical Properties RT0624.04-14 07/07/2014 ATL (TST3782) Physical Properties RT1210.02-15 12/17/2015 ATL (TST3782) Physical Properties RT1210.03-15 12/17/2015 ATL (TST 3782) Physical Properties RT1103.01-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.02-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.03-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.04-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.05-15 11/07/2015 Miami -Dade (CER1592) HVHZ Compliance 14-0416.12 11/27/2014 Miami -Dade (CER1592) HVHZ Compliance 15-0721.04 11/05/2015 Miami -Dade (CER1592) HVHZ Compliance 16-0112.06 02/25/2016 Miami -Dade (CER1592) HVHZ Compliance 16-0112.07 02/25/2016 Miami -Dade (CER1592) HVHZ Compliance 16-0112.08 02/25/2016 Tile Roof Institute TAS 100, TAS 101, 102,102(A) Membership Confirmation Current PRI (QUA9110) Quality Assurance Service Confirmation Exp.11/02/2018 Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4 i Certificate of Authari:ation#9503 6r"EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 I Entegra Roof Tiles Revision 4:10/17/2017 Page 2 of 8 I -1 TRINITY I ERD , PRODUCT DESCRIPTION: 4.1 1 TA 112, Type 3a (flat -profile) BERMUDA FLAT, PLANTATIONfLAT and! HORizoN,F -AT, Bermuda Flat % 17-114" 13" Horizon Flat Plantation Flat Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4 ao/Authoriration#9503 6'"EDITION 12017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 3 of 8 TRINITY I ERD 4.2 TAS 11-2; Type 1a (interlocking, high -profile) BELIA,HIGH "S", Bella High "S" 4.3 1 TAS 112, Type 1b (interlocking, low -profile) ESTATE "V and HACIENDA Holes —I Estate "S" Hacienda 4.3 1 TAS 112, Type 2a (non -interlocking, high -profile) GALENA SPANISH "S" andi-REGAL 17" Galena Spanish "S" Exterior Research and Design, LLC. Certificate ofAuthorization #9503 10" C"EDITION (2017) FBCHVHZEVALUATION Entegra Roof Tiles Evaluation Report E39310.11.11-1-R4 FL7804-R10 Revision 4:10/17/2017 Page 4 of 8 ��TRINITYJERD 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements. 5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for fire rating of this product. 5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations. 5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in accordance with TAS 112, Appendix W. 5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in FBC HVHZ jurisdictions. 5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements. 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of RAS 118, RAS 119 or RAS 120, as applicable. 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in accordance with Roofing Application Standard RAS 127-11 using the data outlined herein. TABLE 1: AERODYNAMIC MULTIPLIERS -91. (FT) Tile Batten Application Direct -Deck Application Bermuda Flat 0.189 0.205 Plantation Flat 0,267 0.289 Horizon Flat 0.305 0.330 Bella High "S" 0.349 0.378 Estate "S" 0.267 0.289 Hacienda 0.267 0.289 Galena Spanish "S" N/A 0.235 Regal 0.287 0.311 TABLE 2: RESTORING MOMENT DUE TO GRAVITY- M. (FT-LBF) Tile Roof Slope (0) 2:12<0<3:12 3:12<0<4:12 4:12<0<5:12 5:1250<6:12 6:12<A<7:12 02:7:12 Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Bermuda Flat 5.22 6.43 5.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 5.83 Plantation Flat 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Horizon 7.60 8.32 7.52 8.24 7.41 8.12 7.26 7.95 7.09 7.76 6.89 7.55 Bella High "S" 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13 Estate "S" 6.14 6.84 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14 Hacienda 5.92 6.80 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6.22 Galena Spanish "S" N/A 6.20 N/A 6.13 N/A 6.03 N/A 5.89 N/A 5.74 N/A 5.57 Regal 7.77 8.34 7.77 8.34 7.65 8.20 7.49 8.03 7.30 7.83 7.10 7.61 Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report E39310.11.11-1-R4 6r" EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4.10/17/2017 Page 5 of 8 �I TRINITY ERD TABLE 3A: ATTACHMENT. RESISTANCE EXP.RESSED•AS A MOMENT-MF#,T-LBF) Ii MECHANICALLY ATTACHED SYSTEMS i Tile Fastener Direct -Deck (min.15/32" plywood) Direct -Deck (min.19/32" plywood) Battens Type # Size Shank Clip Nail One (1) 10d Smooth or Screw N/A 7.3 9.8 4.9 Nail Two (2) 10d Smooth or Screw N/A 14.0 18.8 7.4 Nail One (1) 10d Smooth or Screw Eave 19.0 19.0 22.1 Nail One (1) 10d Smooth or Screw Field 24.3 24.3 24.2 Bermuda Flat, Nail Two (2) 10d Smooth or Screw Eave 31.9 31.9 32.2 Plantation Fiat or Nail Two (2) lod Smooth or Screw Field 35.5 35.5 34.8 Horizon Nail Two (2) 10d Ring N/A 30.9 38.1 17.2 Nail' Two (2)' 10d' Ring' N/A 50.3' 65.5' 48.3' Screw One (1) #8 N/A N/A 30.8 30.9 18.2 Screw Two (2) 48 N/A N/A 51.7 51.7 24.4 ' Installation with a 4-inch tile headlap and fasteners located min. 2Y,-inch from head of tile. Nail One (1)' lod Smooth or Screw N/A 8.8' 11.8' 4.1' Nail Two (2) 10d Smooth or Screw N/A 16.4 21.9 7.1 Nail One (1)' 10d Smooth or Screw Eave 19.0' 19.0' 22.1' Nail One (1)' lod Smooth or Screw Field 24.3' 24.3' 24.2' Nail Two (2) 10d Smooth or Screw Eave 31.9 31.9 32.2 "S" Nail Two (2) 10d Smooth or Screw Field 35.5 35.5 34.8 Estate or Hacienda Nall Two (2) 10d Ring N/A 27.6 37.4 28.8 Nail' Two (2)' 10d' Ring' N/A 43.0' 67.5' S0.9' Screw One (1)' N8 N/A N/A 25.8' 25.8' 22.9' Screw Two (2) 48 N/A N/A 47.1 47.1 49.1 ' Installation with a 4-inch tile headlap and fasteners located min. 2%-inch from head of tile. ' For one (1) fastener Installations, utilize hole that is approximately 4%-inch from the interlocking edge. Nall One (1) 10d Smooth or Screw N/A 5.1 6.8 2.8 I Nail Two (2) 10d Smooth or Screw N/A 6.9 9.2 7.3 Nail One (1) lod Smooth or Screw Field 23.1 23.1 19.0 Nail One (1) lod Smooth or Screw Eave 29.3 29.3 24.0 Nail Two (2) lod Smooth or Screw Field 27.6 27.6 38.6 Bella High "S", Galena Spanish "S" or Regal Nail Two (2) lod Smooth or Screw Eave 38.1 38.1 41.8 Nail Two (2) 10d Ring N/A 28.6 41.2 19.4 Nail' Two (2)' 10d' Ring' N/A 33.1' 48.1' 50.9' Screw One (1) #8 N/A N/A 20,7 20.7 18.1 Screw Two (2) 48 N/A N/A 43.2 43.2 29.8 ' Installation with a 4-inch tile headlap and fasteners located min. 2Y-inch from head of tile. Exterior Research and Design, I.I.C. Evaluation Report E39330.11.11-1-R4 Certificate of Authorization #9503 6'" EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 6 of 8 TRINITY I ERD TABLE 4: ATTACHMENT RESISTANCE EXPRESSED'AS A MOMENT— MP(FT-LBF) MORTAR AND ADHESIVE -SET SYSTEMS Note from Entegra Roof Tile, LLC.: The performance data listed in Table 4 ore based on the, respective. adhesive,manufacturers' test, reports and: Miami -Dade NOAs. Entegra Roof Tile, LLC. relies upon the adhesive manufacturers to -provide these values for. our inclusion In this FBC HVHZ Evaluation Report. Please consult the individual adhesive, manufacturer. for information .on product :approvals, limitations, revisions or other information for determining wind load and overturning moment performance. Tile Adhesive Tile Product Product Approval Placement Mf (ft-lbf) "TILE BOND'"" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 41 Bermuda "Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 73 Flat' "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 52 Plantation Interdependent (2-paddy) 43 Flat or Horizon "Polyset° AH-160" by ICP Adhesives & NOA 17-0322.03 Independent (medium paddy, ^30 g) 51 Sealants Independent (large paddy, -45 g) 92 "TILE BOND"' by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 44 "Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 42 "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 44 Estate "S" or Interdependent (2-paddy) 50 Hacienda "Polyset® AH-160" by ICP Adhesives & NOA 17-0322.03 Independent (medium paddy, —30 g) 37 Sealants independent (large paddy, —54 g) 61 Mortar Various Per RAS 120 21 "TILE BOND'"" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 48 "Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 52 Bella High "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 36 "S", Galena Interdependent (2-paddy) 30 Spanish "S" or Regal "Polyset® AH-160" by ICP Adhesives & NOA 17-0322.03 Independent (medium paddy, ^30 g) 49 Sealants Independent (large paddy, —63 g) 94 Mortar Various Per RAS 120 25 7. LABELING: 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. and/or ENTEERA v,:�7 Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4 Certificate ofAutharization #9503 6C'EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4,.10/17/2017 Page 7 of 8 QOTRRINITY ERD -FL' and/or . H a. n s o n Labeling: Horizon Flat, Hacienda, Regal 8. BUILDING PERMIT REQUIREMENTS: i As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: I Plant. Profiles Okeechobee, FL Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" Ft. Myers, FL Horizon Flat, Hacienda Deerfield Beach, FL Horizon Flat, Hacienda, Regal 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777 - END OF EVALUATION REPORT — Exterior Research and Design, I.I.C. Certffcate ofAathori:ation #9503 e" EDITION (2017) FBL HVHz EVALUATION Entegra Roof Tiles I i Evaluation Report E39310.11.11-1-R4 FL7804-R10 Revision 4:10/1712017 Page 8 of 8