HomeMy WebLinkAboutBLOWER DOOR TEST FORMe(GANNED
BY
� e UCIP, COUAW
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
Phone:772-462-2165 Fax:772-462-6443
BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
3/29/19
Grande Construction
AJAR 2 9 2018
ST, Lucie County, Per
mltting
Permit #: slc. 190 7 da 40-
12366 Lear Place Port St Lucie
Job 'III ddress: .
Construction: (`iC) New Construction — Complete ( ) Existing — After Addition
Hodse Infiltration Test Results SLC Climate Zone 2
CF 111� (50) = �� Test Date:
Volume Sy
ACH (50) = CFM (50) x 60 / Volume Mechanical Ventilation required less than 3 ACH
Pasiing results must be & ACH (50) or less (Pass ( ) Fail
tnergy
wilding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
er door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
:)n 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
wed third party. A written report of the results of the test shall be signed by the party conducting the test and
ded to the code official. Testing shall be performed at any time after creation of all penetrations of the building
val envelope.
FBC; Residential
Whire the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
prep sure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
thej�dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
pany Name: Florida Energy Testing
Address: 1026 SW Payne Ave PSL
eby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
irements in accordance with Section R�OZ)4/Z2 Climatq.Zone 2. 1
Name: Russell Pellecchia
nse/Certification #: BPI 5060997