BLOWER DOOR TEST FORM
House Infiltration Test Certification 1
ST. Lucie Ctunty, mrmltting
Prescriptive and Performance Method
Permit #: / ,q07 a Q Z j 3
ress: 3 L10 y f32,;4- P►vl -D r 01 e•4-D6wr6 D
ction: ( /9 New Construction — Complete ( ) Existing — After Addition
;e Infiltration Test Results SLC Climate Zone 2
Test Date: ,5:Z_7L1y
me=%1/0
(50) = CFM (50) x 60 / Volume = �� Q Mechanical Ventilation required less than 3 ACH
ng results must be & ACH (50) or less Wf Pass ( ) Fail
FBC' Energy
The wilding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hou'I in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blo er door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Sec on 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
app oved third party. A written report of the results of the test shall be signed by the party conducting the test and
pro ided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
the, fnal envelope.
FB 1 Residential
Wh re the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the,dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
ny Name:
Florida Energy Testing
Address: lDa& S. w. P4awG Jot% PSI -
I heby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
rea irements in accordance with Section R402.4.1.2 Climate Zone 2.
Name: Russell Pe_ 1aC4k cC_
rose/Certification #: 5-0(aQ5g7 0. P� Z.