Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutPRODUCT APPROVAL-t'--—
0
OP
t Regulation
mrim
BCiS Home ! Log.In J User Registration Hot Topirs I 'Submit5urcharge " Stats.@Facts Pubiicabons FBC,Staff BCIS ,Ste.Map Llnks fMSeaich .j
i, Product Approval 1
USER: NO%User r "� r
pmdurt Aooroval Menu > Product or Aoollcation Search > AoolioUon LIB > Application Detain
FL # FL16048-13,6
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Tri-Built Materials Group, LLC
Address/Phone/Email
PO Box 70
Rutherford, NJ 07070
(800)516-1485
david.ruiz@tribuiltmg.com
Authorized Signature
David Ruiz
david.ruiz@tribuiltmg.com
Technical Representative
David Ruiz
Address/Phone/Email
250 Route 17 North
East Rutherford, NJ 07073
(201) 842-2449
david.ruiz@tribuiltmaterialsgroup.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John. W. Knezevich, PE
R Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL16048 R6 COI '2017 01 COI Nieminen odf
Standard
ASTM D1970
ASTM G155
FM 4474
FRSA/TRI April 2012 (04'-12)
UL 1897
floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtFPmdYiND...
Year
2015
2005
2011
2012
2012
1/12/2018 j
i
Building Code Online
Page 2 of 2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
09/25/2017
10/01/2017
10/03/1017
12/12/2017
FL At
Model, Number or Name
Description
16048.1
TRI-BUILT Roof Underlayments
Self -adhering, modified bitumen roof underlayments
Limits of Use
Approved for use. in HVHZ: No
Installation Instructions
FL16048 R6 II 2017 09 FINAL ER TRI-
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
BUILT UNDERLAYMENTS FL16048-R6.Ddf
Design Pressure: +N/A/-150
Verified By: Robert N(eminen PE-59166
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use
Evaluation Reports
of foam -on the systems overtop the self -adhering
underlayment for one particular application. See ER Section
FL16048 R6 AE 2017 09 FINAL ER TRI-
S.6.4 for details. 2.) Refer to ER Section 5 for other Um' its of
BUILT UNDERLAYMENTS FL16048-R6 pdf
Created by Independent Third Party: Yes
Use.
Bacic Next
Contact Us :; 2601 Blair Stone Road Tallahassee FL 32390 Phone: 85D-487-1824
The State of Florida Is an AAfEEO employer. Coovrioht 2007 2013 State of Florida :: Privacy Statement :: Accessibility Statement :: &fund Statement
Under Florida law, email addresses are public records. If you do not want your e-mall address released In response to a public -records request, do not send
electronic mall to this. entity. Instead, contact the office by phone or by traditional mail. if you have any questions, please contact 850.487.139S. -Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, FS. must provide the Department with an email address if
they have one. The emails provided may be used for official communication with the licensee. However email addresses. are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which an be made available to the public. To determine If you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
® ®Nix IeCfal
Credit•
Safe
securltvllk'rm
://Www.floridabuilding.org/pr/pr—app_dtl.aspx?param=wGEVXQwtDgtFPmdYiND... 1/12/2018
ERD
\I.TRINIIY
EVALUATION REPORT
TRI-BUILT Materials Group,
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
EXTERIOR RESEARCH. & DESIGN, I.I.C.
Certificate of Authorization #9503
353CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report A42960.10.12-116
FL16048-R6
Date of Issuance:10/25/2012
Revision 6: 09/25/2017
SCOPE:
This Evaluation'Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILTRoof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report invalid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to theiproduct change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityI ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation. Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall, be provided to the user by the manufacturer or
its distributors and shall be available for inspection at thejob site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DC4ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 09/25/2017. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
�t 1 RINITi I ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI=BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 60 Edition (2017) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2. STANDARDS:
Section
1504.3.1
1504.3.1
1504.6
1507.2.4 / 1507.1.1,1507.2.9.2
1507.3.3
3. REFERENCES:
4.
S.
EntitV
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD '(TST6049)
ERD (TST6049)
ERD (TST6049)
UL, LLC. (QUA9625)
UL, LLC. (QUA9625)
Property
Wind Resistance
Wind Uplift
Accelerated Weathering
Physical Properties
Physical Properties
Examination
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Accelerated Weathering
Wind Resistance
Quality Control
Quality Control
Standard
Year
FM 4474
2011
UL1897
2012
ASTM G155
2005
ASTM D1970
2015
FRSA/TRI April 2012 (04-12)
2012
Reference
S40540.02.13-1
S40540.11.13
S40540.03.14
S44870.04.14-2
S44870.04.14-3
S44870.04.14-1
S44870.04.14-4
S43530.02.14-1-R1
S43530.05.14
S40540.10.14
SC7645.02.15
SC8520.04.15.
SC14045.05.17-111
Multiple -Listing 1116814
Service Confirmation
Date
02/19/2013
11/19/2013
03/26/2014
04/02/2014
04/02/2014
04/10/2014
04/10/2014
05/14/2014
05/28/2014
10/31/2014
02/13/2015
05/27/2015
06/07/2017
12/10/2015
Exp. 07/18/2020
PRODUCT DESCRIPTION:
4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced; sand -surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970.
4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof underlayment; meets ASTM D1910 and FRSA/TRI April 2012.
4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS
modified bitumen roof underlayment; meets ASTM D1910.
LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6
Certificate ofAuthorizatlan #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (400) 516-1485 Revision 6: 09/25/2017
Page 2 of 6
\,/\TR1N1'TYjERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
;TABLE 1 ROOF COVER:OPTIONS
Underlayment
Asphalt
Shingles
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes
Slate
& Shingles
Tri-Built Sand-R SA Shingle
Underlayment
Yes
No
No
No
Yes
Yes
Tri-Built $/A HT TU
Yes
Underlayment
Yes
Yes
See 5.5.1
Yes
Yes
Yes
r_Tr7--8uilf Smd6th7H" 5/A
Underlayments ;,
:Yes`
No
NoYes3
Yes
``:.:Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / unrlarlavmant rnrnhinn+.„n,
TABLE 1A:-ALLOwABLE TILE ADHESIVE / UNDERLAYMENT CONIBINATIONS1
Adhesive
Florida Product Approval
Underlayments
ICP Adhesives Polyset° AH-160
FL6332
Tri-Built S/A HT TU Underlayment
Dow TileBond'°
FL22525
Tri-BuiltS/A HT TU Underlayment
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Plywood; ASTM D41 primed plywood; OSB ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or
OSB prior to installation of the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474, Appendix D or TAS 114, Appendix J.
s Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Research and Design, U.C. Evaluation Report A42960.10.12-R6
to of Authorization #9503 6"' EDITION (2017) FBC NON-HVHZ EVALUATION FL36048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 3 of 6
TRINITY (ERo
5.6.3 Bond to Mechanically Attached Base Laver:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ ASTM D226, Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-
12).
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms'part of the load -path. The following wind uplift limitations apply to direct -deck
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on -tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or
FBC 1609for determination of design. wind pressures.
#1 Maximum Design Pressure = -45 0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
#2 Maximum Design. Pressure =-67 5 psf:
Deck: Structural concrete to meet project requirements 'to satisfaction of Authority Having
Jurisdiction.
Primer: Soprema Elastocol 600c
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
#3 Maximum Design Pressure = -150 0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end -laps.
#4 Maximum Design Pressure =-60 0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction. .
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
xterior Research and Design, LLC. Evaluation Report A42960.10.12-R6
'ertificote of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments, (800) 516-1485 Revision 6:09/25/2017
Page 4 of 6
TRINITY SERD
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3. enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04 12))•
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TABLE2:'TILE SLIPP,AGE.I:IMITATIONSFOR DIREGI-DECK TILE INSTALLATIONS .
Underlayment
Tile Profile
Staging Method
Maximum
Slope
Flat
Max. lO the stack
6:12
Lugged
Max.10-tile stack
5:12
Max.10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high 6:12
on slope, as shown below)
Tri-BuiltS/A HTTU
Underlayment
Lugged
ixterior Research and Design, U.C. Evaluation Report A42960.10.12-116
:ertificate of Authorization #9503 6T" EDITION (2017)`F13C NON-HVHZ EVALUATION F1.16048-136
TRI-BUILT Roof Underlayments, (800) 516-1485 Revision 6: 09/25/2017
Page 5 of 6
\,l TRINITY (ERD
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri-Built Sand-R SA Shinele. Underlayment Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile applications:
While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10'ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll,, broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRI-BUILT Materials Group, LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials, Group, LLC recommends back -nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications (Tri-Built S/A HTTU Underlayment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference- is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Gulfport, MS
9. QUALITY ASSURANCE ENTITY:
UL, LLC— QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R6
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.16048-116
TRI-BUILT RoofUnderlayments; (800) S16-1485 Revision 6: 09/25/2017
Page 6 of 6
s
Building Code Online Page 1 of 4
am .uuc�q OMWAV
Professional°.® _
:.
BCIS Home : Cog In ; User Registration Hot-ropirs f Submit Surcharge Sbts & Facts Publicationsi FBC Staff I BCIS'Site Map i Unks { Search i
Pda roduct Approval
USER:Public User
Product Approval Menu > product or Application Search >. Aooliration List > Application Detail
/&76
FL# FL34645-R3 ST. LUCIE COUNTY BUILDING DIVISION
Application Type Revision REVIEWED FOR COMP I CE
Code version 2017 REVIEWED Y
Application Status Approved DATE 7
PLANS AND PE MIT ST KEPT ON JOB
Comments SITE OR NO INSPECTIONS) WILL BE MADE
Archived
Product Manufacturer Metal Sales Manufacturing Corporation
Address/Phone/Email 545 South 3rd Street, Suite 200
Louisville, KY 40202
(502) 855-4300
dstermer@metalsales.us.com
Authorized Signature David Stermer
dstermer@motaisales.ut.com
Technical Representative FILE COPY
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
--, Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc..
Quality Assurance Contract Expiration Date 12/27/2026
Validated, By Yoosef Lavi, P.E.
L Validation Checklist - Hardcopy"Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL14645 R3 COI Certificateindenendence.odf
Standard
Year
FM 4470
2012
TAS 125
2003
UL 1897
2012
UL 580
2006
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDq.sw8ZVNfe8A... 1 /12/2018
METAL SALES MANUFACTURING CORPORATION
5V-Criinp Uplift Loads
(Min. 26 ga.)
Description
Fastener Spacing
along panel length
(in)
Allowable Uplift
Load
(psf)
Coverage width: 24"
Panel Fasteners
#9-16 or #10-14 hex head
wood screws with sealed
washer
6
_ 172.5
_
9
120.0
15
72.0
18
- 60.0 _
21
51.4 _
24
45.0
27
40.0
-- 30
36.0
32.7 _
V 30.0
33
36 -
Notes:
1. The bold numbers indicate design loads calculated from test data with safety factor of 2.
2. Panels must be installed as per Evaluation Report FL 14645.4 and Metal Sales current installation procedure.
3. Three or more spans condition.
1216 N Lansing Ave., Suite C
Tulsa, Ok 741.06
918 492 5992
oao°�6�50CKA4 g0�so
0
4e®�` ��P�' � G �E N S ' �•' ��'s�
No 62240
P
m
�� • ° R
p
STATE OF' ;�w�
C�
O
61
Bala Sockalingam, Ph.D., P.E.
FL 62240
5V-CRIMP PANEL OVERLAP
SEE DETAIL 2 / SEE DETAIL 1
#9-16 OR #10-14 WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 36" O.C.
FASTENER AT PANEL FLAT
REQUIRED FOR PANEL
ENDS ONLY.
MINIMUM ATTACHMENT:
8d x 2.5" LONG RING SHANK NAIL
UNDERLAYMENT SHALL BE INSTALLED OR #8 x 2" LONG WOOD SCREWS
AS PER MANUFACTURER'S INSTALLATION SPACED ® 6" O.C. IN THE FIELD
GUIDELINES & AT EDGES
MIN. 2X- WOOD RAFTER/JOIST/
TRUSS AT MAX. 24" O;C.
TYPICAL PANEL INSTALLATION X-SECTION
5V-CRIMP
MIN 26 GA.
UNDERLAYMENT --J -- �OSB 7/16" THICK (MIN.) OR
q
DETAIL 1 PLYWOOD 15/32 THICK (MIN.)
#9-16 OR JIO-14 WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 36" O.C.
5V-CRIMP
MIN 26 GA.
PANEL FASTENER PER UPLIFT
LOAD TABLE
a
00
U N
Wo
ENO
N�M
G Ln
�zg ow Ln
2 co
N
O
o1n
NJ
N
w
4i.
a
GENERAL NOTES:
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
IN
j
c
a e
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE MIN. 26 GA, (t = 0.019"). EFFECTIVE COVERING
a
B;m
WIDTH OF PANEL = 24".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
z oP
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
N
i
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
JN
w
ARE GREATER THAN THE DESIGN UPLIFT PRESSURES SPECIFIED ON THIS DRAWING.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA'
;
i
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
B
6. RAFTERS/JOISTS/TRUSSES MUST BE .DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
UNDERLAYMENT J \--OSB 7/16- THICK (MIN.) OR � �
DETAIL 2 PLYWOOD 15/32 THICK (MIN.) of
FL 1.4645.4-R3
C2182-4
9.9.17
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
Panel Description: 24" wide coverage with (5) 1 /2" high ribs
Materials' Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description: Min. 7/16" thick OSB or min. 15/32" thick plywood or min. V thick
wood plank (min. SG of 0.42) for new and existing constructions.
Designed by others and installed as per FBC 2017.
Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
(Minimum) in the plywood field and edges. Designed as per FBC 2017.
Underlayment: Minimum underlayment as per FBC 2017 Section 1.507.4.5.1.
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2.
Requires applied lap sealant for roof slopes less than 3:12.
Design Uplift Pressure: 30.0 psf @ fastener spacing of 36" o.c.
(Factor of Safety = 2) 172.5 psf @ fastener spacing of 6" o.c.
Fastener Pattern:
Type: 99-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8" and installed as per Metal Sales current installation procedure.
At panel ends @ 6" o.c. across panel width
At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance
of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering
Systems'.
Test Equivalency: The test procedures in UL 1897-04 comply with test procedures
prescribed in UL 1897-12.
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
Product Approval Method Method 1 Option D
Date Submitted 09/09/2017
Date Validated 09/14/2017
Date Pending FBC Approval 09/15/2017
Date Approved 12/12/2017
Summa of Products
FL # Model, Number or Name Description
14645.1 2.5" Corrugated Min. 26 panel over
Amin. 19/32" through fastened roof
thick plywood deck.
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL14645 R3 II EvaluationReogrtC2182 1.odf
Approved for use outside HVHZ: Yes Verified
Created by:IBala Sockalingam
entThi d Party: Yes
impact Resistant: N/A
Design Pressure: +N/A/-86.0 Evaluation Reports
Other: Uplift load of 82.3 psf at fastener spacing of 36" o.c. FL14645 R3 AE Evaluatl0nReportC2182 Lodf
and 86.0 psf at fastener spacing of 12" o.c. Created by Independent Third Party: Yes
14645.2 5V-Crimp Min. 26 ga., 24 wide through fastened roof panel over min.
19/32" thick plywood deck with fasteners through panel flat.
Limits of Use Installation Instructions
Approved for use in HVHZ: No F1.14645 R3 II gvaluationRep0rtC21f32 2 odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-.149.6 Evaluation Reports
Other: Uplift load of 84.5 psf at fastener spacing of 24" FL14645 R3 AE EvaluationReportC2182 2 odf
o.c., 131.3 psf at fastener spacing of 18" O.C. and 149.6 psf Created by Independent Third Party: Yes
at fastener spacing of 12" D.C.
14645.3 SV-Crimp Min. 26 ga., 24" wide through fastened roof panel over min.
19/32" thick plywood deck with fasteners through panel rib.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R3 II Eva luationReportC2182 3 Ddf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-196.75 Evaluation Reports
other: Uplift load of 41.6 psf at fastener spacing of 36" FL14645 R3 AE EvaluationReportC2182 3 Ddf
o.c., 74.8 psf at fastener spacing of 16" o.c. and 196.75 psf Created by Independent Third Party: Yes
at fastener spacing of 8" o.c.
14645.4 1 SV-Crimp
Min. 26 ga., 24" wide through fastened roof panel over min.
15/32" thick plywood deck or 7/16" thick OSB with fasteners
through panel rib.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R3 II EvaluationReoo[tC2182 4.1)df
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-172.5 Evaluation Reports
Other. Uplift load of 30.0 psf at fastener spacing of 36" o.c. FL14645 R3 AE EvaluationlleoortC2182 4 adf
and 172.5 psf at fastener spacing of 6" o.c. Created by Independent Third Party: Yes
14645.5
Aluminum Classic Rib
Nom. 0.032" thick, 36" wide, aluminum through fastened
roof panel over min. 15/32" thick plywood deck or 7/16"
thick OSB.
Limits of Use
Installation Instructions
FL14645 R3 II Eva luationReportC2182 5.odf
Approved for use in HVHZ: No
Approved for use outside.HVHZ: Yes
-
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-120
Other: Uplift load of 30 psf at fastener spacing of 36" o.c.
Evaluation Reports
FL14645 R3 AE EvaluationReportC2182 S.pdf
and 120 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
14645.6 Aluminum Vertical Seam Nom. 0.032" thick, 16" wide, aluminum standing seam roof
panel over min. 15/32" thick plywood deck or 7116 thick
OSB.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FI 14645 R3 II EvaluatlonReportC2182 6.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-97.05 Evaluation Reports
Other: Uplift load of 41.6 psf at clip spacing of 36" o.c., FL14645 R3 AE EvaluationReportC2182 6.pdF
71.0 psf at clip spacing of 12" o.c. and 97.1 psf at clip Created by Independent Third Party: Yes
spacing of 12" o.c. with sidelap adhesive.
https://www.floridabuilding.orglpr/pr app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A... 1/12/2018
Building Code Online
Page 3 of 4
14645.7 1 Aluminum Vertical Seam
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ:, Yes
Impact Resistant: N/A
Design Pressure: +N/A/-162.0
Other: Uplift load of 41.6 psf at clip spacing of 36" o.c.,
100.2 psf at dip spacing of 12" o.c. and 162.0 psf at clip
soacinp of 12" o.c. with support strap.
14645.8 I Classic -Rib
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-91
Other: Uplift load of 41.5 psf at fastener spacing of 48" o.c.
and 91 psf at fastener spacing of 6" o.c.
14645.9 1 Classic Rib
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-133.9
Other: Uplift load of. 74.8 psf at fastener spacing, of 36"
o.c., 92.3 psf at fastener spacing of 24" o.c. and 133.9 psf
at fastenersnacino of 18" o.c.
Nom. 0.032" thick, 16" wide, aluminum standing seam roof
panel over min. 19/32" thick plywood deck
Installation Instructions
FL14645 R3 II EvaluatignRenortC2182 7.odf
Verified By: Bala Sockalingam PE.62240
Created by Independent Third Party: Yes
Evaluation Reports
FL14645 R3 AE EvalMgLHonReAortC2182 7. df
Created by Independent Third Party: Yes
Min. 29 ga:, 36" wide through fastened roof panel over min.
15/32" thick plywood deck.
Installation Instructions
FL14645 R3 IL E0luatlonReportC2182 e:pdf
Verified By: Bala Sockalingam PE 6224U
Created by Independent Tlilyd Party: Yes
Evaluation Reports
Third Party: Yes
Min. 26 ga., 36" wide through fastened roof panel over min.
19/32" thick plywood deck.
Installation Instructions
1`L14645 R3 II EyalUationRenortC2182 9.odf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third:Party:.Yes,
Evaluation Reports
FL14645 R3 AE EvaluationReportC2182 9.odf
Created by Independent Third Party: Yes
14645.10
Classic Rib
Min. 29 ga., 36" wideahrough fastened roof panel over min.
7/16" thick OSB deck
Limits of Use
Installation 1nstructions
FL14645 R3 II EvaluatlonReportC2182 10 0df
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-135.0
Other: Uplift load of 45 psf at fastener spacing of 24" o.c.
Evaluation Reports
FL14645 R3 AE EvaluationReoortC2182 10.pdF
and 135 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
14645.11 I Classic Rib
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-138.5
Other: Uplift load of'68.4 psf at fastener spacing of 24" o.c.
and 138.5 psf at fastener spacing of 12" o.c.
14645.12 j,Image II
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-86.55
Other: Uplift load of 20.8 psf at fastener spacing of 24"
o.c., 63.5 psf at fastener spacing of 6" o.c. and 86.55 psf at
fastener spacing of 6" o.c. with sidelap adhesive.
14645.13 1 PBR-Panel or R-Panel
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-131.0
Other: Uplift load of 30.0 psf at fastener spacing of 48" o.c.
and 131.0 psf at fastener spacing of 6" o.c.
Min. 29 ga., 36" wide through fastened roof panel over min.
'15/32" thick plywood deck.
Installation Instructions
FL14645 R3 II EvaluationReportC2182 11.12df
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
F' 14645 R3 AE EvaluationReportC2182 it odf
Created by Independent Third Party: Yes
Min. 26 ga.,.16" wide concealed fastened roof panel, over
min. 15/32"thick plywood deck.or 7/16" thick OSB.
Installation Instructions
FL14545 R3 II EvaluationRgportC2182 12.odf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third. Party: Yes
Evaluation Reports
FL14645 R3 AE Eva luationRenortC2182 12.12
Created by Independent Third Party: Yes
Min. 26 ga., 36" wide through fastened roof panel over min.
15/32" thick plywood deck.
installation Instructions
FL14645 R3 II EvaluationReoortC2182 13.odf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL14645 R3 AE EvaluationReportC2182 13.odf
Created by Independent Third Party: Yes
14645.14 Pro -Panel II Min. 29 ga., 36" wide through fastened roof panel over min.
15/32" thick plywood deck.
https://www.flo.ridabuilding.org/pr/pr app 4tl.aspx?param=wGEVXQwtDgsw8ZVNfe8A... 1/12/2018
Building Code Online
Page 4 of 4
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R3 II EvaluationReoortC2182 14.Ddf
Approved for use outside. HVHZ: Yes Verified By: Bala Sockalingarn PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-71.5 Evaluation Reports
Other: Uplift load of 41.6 psf at fastener spacing of 24" D.C. FL14645 R3 AE FvaluationReDortC2182 14.odf
nnri 71 s ncf at facrpner snacina of 12" D.C. Created by Independent Third Party: Yes
Back Next
Contad Us :: 2601 Blair Stone Road Tallahassee FL 32399 phone: 850-487-Sa2
The State of Florida Is an AA/EEO. employer. Cor)wlght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public remrds. 1f you do not want your e-mail address released in response to a public -records request, do not send
electronic mall to this entity. Instead, contact the office by phone or by traditional mall, If you have any questions, please contact 850.487.1395. *Pursuant to
Section455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under. Chapter 455, F.S. mustprovide the Department with an email address if
they have one. The emails provided. may be used for official communication with the licensee. However email addresses.are public record. if you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
®®© H M
Credit Card
Safe
hops://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A... 1/12/2018
EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
126 GA. 5V-CRIMP PANEL'
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 14645.4-R3
ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502) 855-4290
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX.: (918) 493-3568
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
e%J11111EB/6,9
SOCKAL/N�rdse
Load Span Table (1 Page)
���a`�
E N SF•�q�oe�
�o.`�P�,P;��G
0
® No 62240 d
x
•����/Q
®� STATE OF
Report No. C2182-4
..
� r
`a.,dE`s ••:,O
Date: 9.9.17
R,
AL
oe
as
FL 14645.4-R3
C2182-4
9.9.17
Page 3 of 3
computed using rational analysis prepared by a Florida Professional
Engineer or based on Metal Sales load span table. This evaluation
report is not applicable in High Velocity Hurricane. Zone: Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2017 Section 1505 and current approved roofing materials