Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL8CANNE® By Lucia u 8CI5 Home f Log In I User Registration Hot Topia { Submit Surcharge Stats & Facts O Product Approval USER: Public User r _ Product Approval Menu > Product or Aonlication Search > Application List Search Criteria Code Version 2017 Application Type ALL Category ALL Application Status ALL •Quality Assurance Entity ALL Product Model, Number or Name ALL Approved for use in HVHZ ALL Impact Resistant ALL Other ALL Search Results - Applications; r� Hoot-," -ii'm OBP,IttliNiaj;Ot{u.. CDf{(nGY tSBI?k Refine Search FL# 16027 Product Manufacturer ALL Subcategory ALL Compliance Method ALL Quality Assurance Entity Contract Expired ALL Product Description ALL Approved for use outside HVHZ ALL Design Pressure ALL IF # Tvoe Manufacturer Validated By Status FL1607.7-112 Revision Tri-Built Materials Group, LLC Category: Roofing Subcategory: Modified Bitum@n Roof System John W. Knezevich, PE (954) 772-6224 Approved History -Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POCand/or the Commission if necessary. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coovrioht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida Yaw, email addresses are public records. If you do not want your e-mail address releasedin response to a public -records request, do not send electronic mail to this entity. Instead, contact theoffice by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275 (1), Florida Statutes, effectiveOctober 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be.used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide. the Department with an email address which can be made available to the public. To determine ifyouare a licensee under Chapter 455, RS., please dick hem . Product Approval Accepts: = = M IN E Credit _d Safe securitym vrRlcs* ST. LUCIE COUNTY LDING REVIEWED FOR CO P ANCE DIVISION REVIEWE B DATE l j ( PLANS AND ERM MUS BE KEPT ON JOB SITE OR NO INSP TION(S) WILL BE MADE FILE COPY J \,l TRINIlY I ERD EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street Oxford, CT 06478 (203) 262-9245 EVALUATION REPORT TRI-BUILT Materials. Group, LLC Evaluation Report A42.970.10.12-112 PO Box 70 FL16027-112 Rutherford, NJ 07070 Date of Issuance:10/23/2012 (800) 516-1495 Revision 2: 09/25/2017 SCOPE: This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the'e Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code -requirements with each Code Cycle. . ADVERTISEMENT: The Evaluation Report number preceded by the words `Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall .be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 26-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 The facslmge seal appearing was authorized by Robert Nieminen, P.E. an09/25/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity 1 ERD is not owned; operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. f TRINITY ERD ROOFING SYSTEMS EVALUATION: I SCOPE! Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: TRI-BUILT Modified Bitumen Roof Systems, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the 6ei Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations'/ Conditions of Use set forth herein. 2. STANDARDS. - Section Pro a Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 3. REFERENCES: knilly Examination Reference Date ERD (TST6049) Physical Properties P10490.10.08-2 10/30/2008 ERD (TST6049) FM 4470/4474 P13760.09.09 09/10/2009 ERD (TST6049) FIVI 4470/4474 P13770.09.09 09/10/2009 ERD(TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009 ERD (TST6049) FM 4470/4474 P30550.12.09 12/02/2009 ERD (TST6049) Physical Properties P33960.12.10 12/30/2010 ERD (TST6049) FM 4470/4474 P33970.03.11 03/15/2011 ERD (TST6049) Physical Properties P37590.03.13-3A 03/06/2013 ERD(TST6049) FM 4470/4474 P39680.03.13 03/04/2013 ERD (TST6049) Physical Properties P37590.03.13-1-R1 06/26/2013 ERD (TST6049) Physical Properties P37590.03.13-2-R1 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-2 07/01/2013 ERD (TST6049) Physical Properties P37590:03.13=5-111 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-1 07/02/2013 ERD (TST6049) Physical Properties P45940.09.13 09/04/2013 ERD (TST6049) Physical Properties P44370.10.13 10/04/2013 FM Approvals (TST1867) FM 4470 2W7A7.AM 08/04/1994 FMApprovaIs, (TST1867) FM 4470 OD3A3.AM 04/04/1997 FM Approvals (TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals (TST1867) FM 4470 3006646 01/04/2000 FM Approyals(TST1867) FM 4470 3001334 01/25/M00 FM Approvals (TST1867) FM 4470 3001334 02/15/2000 FM Approvals(TST1861), FM 4470 3000857 01/12/2000 I'M Approvals (TST1867) FM 4470 3004091 01/12/2000 FM Approvals (TST1867) FM 4470 3006115 05/02/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals(TSTA67) FM 4470 30146g2 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3007170 01/13/2004 FM Approvals (TST1867) FM 4470 3019317 06/30/2004 FM Approvals (TST1867) FM 4470 3020703 07/30/2004 FM Approvals (TST1867) FM 4470/4474 3018332 01/31/2006 FM Approvals (TST1867) FM 4470/4474 3023368 03/20/2006 FM Approvals (TST1867) FM 4470/4474 3024594 05/23/2006 Exterior Research and Design, LLC. Evaluation Report A42970.10.12-R2 Certificate op Authorization #9503 6TM EDITION (2017) F13C NON-HVH2 EVALUATION FL16027-R2 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Revision 2: 09/25/2017 Page 2 of 4 Q"TRINITYIERD EntitV Examination Reference Date FM Approvals(TST1867) FM 4470/4474 3023458 07/18/2006 FM Approvals(TST1867) FM 4470/4474 3030668 09/12/2007 FM Approvals(TST1867) FM 4470/4474 8032172 06/12/2009 PRI (TST5878) Physical Properties PUSA-062-02-01 12/04/2007 PRI (TST5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST5878) Physical Properties PUSA-064-02-02 02/27/2008 PRI (TST5878) Physical Properties PUSA-062-02-02 12/04/2008 Miami -Dade (CER1592) HVHZ Compliance Various NOAs Various Miami -Dade (CER1592) Proposal for Review 10-0823 10/12/2010 UL LLC (QUA9625) Quality Control MI -Agreement 02/27/2012 UL LLC. (QUA9625) Quality Control ML Correlation, R27202 08/20/2012 UL LLC (QUA9625) Quality Control Service Confirmation, R14571 Exp.10/06/2018 4. PRODUCT DESCRIPTION: This Evaluation Report covers TRI-BUILT Modified Bitumen Roof Systems installed in accordance with TRI-BUILT Materials Group, LLC published installation instructions and the Limitations / Conditions of Use herein.. The following membranes make up the subject systems. Table 1 Roll=Goods"for-TRI-BUILT Modified -.Bitumen Roof Systems., Type Product Specification Reference Grade Type SBS Membranes TriBuilt.SA SBS Base ASTM D6163, Table 2 S I TriBuilt SBS Granular ASTM D6164 G I TriBuilt SA SBS Cap ASTM D6164 G I APP Membranes TriBuilt APP Smooth ASTM D6222 S 1 TdBuilt APP Granular ASTM D6222 I G I TriBuilt SA APP Cap ASTM D6222 I G I S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Approved Roofing Materials Directory for fire ratings.of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly, shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. Exterior Research and Design, I.I.C. Evaluation Report A42970.10.12-R2 Certificate of Authorization Milli 67N EDITION (2017) FBC NON-HVHZ EVALUATION FL16027-R2 TRI-BUILT Modified Bitumen Roof Systems, (800) 516-1485 Revision 2: 09/25/2017 Page 3 of 4 TRINITY I ERD 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application. Standard TAS 105. 5.10 For bondedinsulation or membrane over existing substrates in a re -roof (tear off or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. 6. INSTALLATION: 6.1 TRI-BUILT Modified Bitumen Roof Systems shall be installed in accordance with. TRI-BUILT Materials Group, LLC published installation instructions, subject to the Limitations / Conditions of Use noted below. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625; (314) 578-3406, k.chancellor@us.ul.com - THE 26-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report A42970.10.12-R2 Certificate ofAuthorization #9503 6r"EDITION (2017) FBC NON-HVHZ EVALUATION F1.16027-112 TRI-BUILT Modified Bitumen. Roof Systems; (800) 516-1485 Revision 2: 09/25/2017 Page 4 of 4 TRINITY! ERa J APPENDIX 1:'4TTACHMENT REQUIREMENTS -FOR WIND UPLIFT RESISTANCE I Table Deck Application Type Description. Page 1A-1 Wood New or Reroof (Tear. -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4 IA-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 1B Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 5 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 1D Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 6 lE-1 Wood. New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 7 1E-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 8 -, 1F Wood._ New or•-Reroof:(Tear-Off),-_ __ __ _.: __ F `� -Non-lnsulated;8oridedVRoof Cover _- 8"` 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation; Bonded Roof Cover 9 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded, Roof Cover 10 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 11-14 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 14 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 15-16 48 LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 16 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 17-19 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 20 5B CWF New, Reroof (Tear -Oft) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 21 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22 SD CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 22 SE CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 22 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation,, Bonded Roof Cover 23 6B Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded insulation, Bonded Roof Cover 24 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation; Bonded Roof Cover 24 6D Gypsum New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 24 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 25-26 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 26 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: D Wood: Minimum 0.75-Inch penetration. Y Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Structural concrete: Minimum 1-Inch embedment into pilot hole in. accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the O.A requirements of F.A.C. Rule 61G2G-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-112 Certificate of Authorization #9503 6"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 1.of 26 TRINrnriERD Minimum 200 psi, minimum 2-inch thick lightweight Insulating concrete may be Substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are Installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). Unless otherwise noted, insulation adhesive application rates aye as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published Instructions. D HA (HA): Full coverage at 25-30 Ibs/square. D Dow INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. D Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-Inch wide ribbons, 12-inch o.c. D OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o,c. (PaceCartor SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. D OlyBond Classic(OB' Classic): Full coverage at 1 gal/square. D ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. D Note: When multiple layers(s) of insulation and/or coverboard are Installed In ribbon -applied adhesive, adhesive ribbons shall be staggered from layer-ta-layer a distance of one-half the ribbon spacing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing: Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed fora particular system in the tables, then the thinner board listed.below may be used as a drop -in for the equivalent thicker material listed in the table: D Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) D OMG OlyBond 500 (OB500): MDP -45.0 psf (ivlin. 0.5-inch thick Multi -Max FA-3) D OMG OlyBond 500 (OB500): MDP -187:5 psf (Min.0.5-Inchthick ISO 95+GL) D OMG OlyBond 500 (0B500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) D OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam 11) D ICP Adhesive & Sealants CR-20: MDP -117.5 psf (Min. 1.0-Inch thick) S. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design, professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDS, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re -roof Installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting projectdesign,pressures on its own merit to the satisfaction of the Authority Having. Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D, the Insulation is optional; however, the existing roof system shall be suitable for a recover application. 14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. Exterior Research and Design, I.I.C. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R2 for FL36027-R2 Certificate of Authorization B9503 67H EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems;. (800) 516-1485 Appendix 1, Page 2 of 26 TRINITY i ERD 15. Unless otherwise noted, refer to the following references for bonded base; ply or cap sheet applications. , TATRI;BUILTROOF:C0'ERs Reference Layer Material Application BP -AA Base Ply FBC Approved ASTM D4601, Type 11 (Base and Ply sheets, Asphalt -Applied) HA at 20-40 Ibs/square Ply FBC Approved ASTM D2178, Type IV or VI SBS-AA' (SBS,.Asphalt-Applied) Cap Ply TriBuilt SBS Granular HA at 20-40 Ibs/square SBS-TA (SBS, Torch Applied) Cap Ply TriBuilt SBS Granular Torch -Applied SBS-SA. Base Ply TriBuilt SA SBS Base (SBS, Self -Adhering) Self -Adhering Cap Ply TriBullt SA SBS Cap APP-TA Base Ply or Ply TdBuilt APP Smooth (APP, Torch -Applied) Torch -Applied Cap Ply TriBuilt APP Smooth, TriBuilt APP Granular APP-SA (APP, Self -Adhering) Cap Ply TriBulit SA APP Cap Self -Adhering 16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations; The lesser of the MDP listings below vs. those in Table 3A applies: VAPOR BARRIER OPTIONS; STRUCr-URALCONCRETE DECK; AO,HEREO MsulAT1oN PER TABLE 3A' Option # Primer Vapor Barrier Insulation Adhesive MDP (psf) Type Attach VB-1. ASTM D41 TriBuilt SA SBS Base Self -Adhering Inta-Stik or CR-20,12-inch o.c. -60.0 VB-2. ASTM D41 TriBuilt SA SBS Cap Self -Adhering Insta-Stik, 12-Inch o.c. -75.0 VB-3., ASTM D41 TriBuilt SA SBS Cap SeIf.-Adhering Millennium One Step Foamable Adhesive, 12-inch o.c. -157.5 VB-4. ASTM D41 TriBuilt SA SBS Cap Self -Adhering CR-20,12-irich o:c. -270.0 VB-5. ASTM D41 TdBuilt SA SBS Base Self -Adhering Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade Adhesive, OlyBond 500 or CR-20,12-inch o.c. -290.0 17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements. 18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable.wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization 09503 6' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 3 of 26 TRINITY 1 ERD TABLE 14=1 WOOD DECKS ."','NEW CONSTRUCTION oh REROOF {TEAR' OFF) SYSTEMTYPEA-2:.MECHANICALLY ATTACHED ANCHOR SHEFT, BONDED INSULATICON,BONDEDROOFCOVER., „ System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP No. (Note 1) (Psf) Type Fasteners Attach Type Attach Type Attach Base Ply Ply cap Ply Min. 0.25-inch Dens Polyglass G2 Base, 8-inch o.c. in 4- Deck, Dens Deck Prime, Min. 19/32- CertalnTeed Glasbase, 32 ga., 1-5/8- inch lap and 8- (Optional) FBC SECUROCK Gypsum - inch plywood Firestone MB Base, JM inch diameter inch o.c. in Approved, Fiber Roof Board, Min. (Optional) SBS-AA, W-1 max. 2r Tamko tin caps with 11 three, equally ASTM C1289 HA 0.75-inch FescoBoard HA BP -AA BP SBS-TA,. -60.0 In Inch spans spans GlassPermBase Glass Base or ga. annular ring spaced, type II polyiso- (homogeneous) or min. APP-TA GAFGLAS #75 shank nails staggered cyanurate 0.5-inch Structodek center rows High Density Fiberboard Roof Insulation Polyglass G2 Base, 8-inch o.c. In 4- Min. 19/32- CertainTeed Glasbase, 32 ga., 1-5/8- inch lap and 8- (Optional) FBC Min. 0.25-inch Dens (Optional) SBS-SA, inch plywood Firestone MB Base, JM inch diameter inch o.c. in Approved, Deck, Dens Deck Prime, One or APP-SA, W-2 at max.24- Perma-Ply 28, Tamko tin caps with 11 three, equally ASTM C1289, HA SECUROCK Gypsum- HA SBS-SA more SBS- SBS-TA or -60.0 inch spans Glass Base or ga. annular ring spaced, type II polyiso- Fiber Roof Board SA or APP TA GAFGLAS#75 shanknails staggered cyanurate APP-TA center rows 6-inch o.c. In 4- Min. 2-Inch D-IS, OB500, Min.19/32- 32 ga., 1-5/8- inch lap and 6- ACFoam II, III, CR-20 or M- Min. 0.25-inch Dens D4S, inch plywood Polyglass Elastobase Inch diameter inch o.c. in H-Shield, H- OSFA, atop Deck, Dens Deck Prime OB500, (Optional) SBS-AA, W-3 at max. 24- or Polyglass tin caps with 12 four, equally Shield CG fastener or SECUROCK Gypsum- CR-20 or BP -AA BP -AA SBS-TA, -60:0* Inch spans Elastobase Poly ga. annular ring spaced, Multi -Max FA3 rows, 7-inch Fiber Roof Board M-OSFA APP TA shank nails staggered center tows orENRGY-3 cc 6-inch c.c. In 4- Min. 2-inch D-IS, OB500, Min. 19/32- 32 ga., 1-5/8- Inch lap and 6- ACFoa m il, III, CR-20 or M- DAS, (Optional) SBS-SA, inch plywood Polyglass Elastobase Inch diameter Inch o.c. in H-Shield, H- OSFA, atop (Optional) Additional OB500, One or APP-SA, W-4 at max. 24 or Polyglass tin caps with 12 four, equally Shield CG, fastener layers of base insulation CR-20 or SBS-SA more SBS- SBS-TA or -60:0' inch spans Elastobase Poly ga. annular ring spaced, Multi -Max FA3 rows, 7-inch M-OSFA SA or APP TA shank nails staggered or ENRGY-3 cc APP TA center rows Exterior Research and Design, I.I.C. d/b/a Trinity IERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 0i EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL16027-R2 Revision 2: 09/25/2017 Appendix 1, Page 4 of 26 TRINITY I ERA TABLE=1A-2 . WOOD DECKS —NEW CONSTRUCTION, REROOF (TeaR OFF) OR RECOVER SYST,EMTYPEA 2:>MECHANICALLYATTACHE6ANCHOR,SHEET, BONDED IN5ULATION, BONDED ROOF COVER •; System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply (Psf) 12-inch o.c. in 4- Min. 0.25-inch Dens Deck, Min.19/32- Polyglass OMG Flat inch lap and 12- (Optional) FBC Dens Deck Prime, SECUROCK Inch plywood Elastobase or .Bottom Plates inch o.c, in two, Approved, Gypsum -Fiber Roof Board, (Optional) SBS AA, SBS- W-S at max. 24- Polyglass (square) with equally spaced, ASTM C1289, HA Min. 0.75-Inch FescoBoard HA BP -AA BP -AA TA, APP-TA -60.0 inch spans Elastobase Roofgrip #12 staggered center type Il polyiso- (homogeneous) or min. 0.5- Poly cyanurate inch Strudodek High Density rows Fiberboard Roof Insulation Min.19/32- Polyglass OMG Flat 12-inch o.c. in 4- inch lap and:12- (Optional) FBC (Optional) Inch plywood Elastobase or Bottom Plates inch o.c. in two, Approved, Min. 0.25-inch Dens Deck, One or SBS=SA, APP- W-6 at max.24 Polyglass (square)with equally spaced, ASTM C1289, HA Dens Deck Prime, SECUROCK HA SBS=SA more SBS- SA, SBS-TA -60.0 Inch spans Elastoliase Roofgrip #12 staggered center type ll polyiso- Gypsum -Fiber Roof Board SA or APP- or APP-TA Poly cyanurate TA rows *ABLE WOOD'DECKS—'NEW ;CONSTRUCTION, REROOF (TEnR OFF) oa RECOVER SYSTEIVITYPEB MECHANICALLYATTAGHEDBASE IN5ULAATION,BONDEDTOP.INSULATION,,BONDED ROOECOVER System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note 1) (psf) Type Fasteners Attach Type Attach Base Ply Ply Cap Ply Min. 19 32-inch / Min. Dekfast Hex with Min. 0.75-inch FescoBoard (Optional if (Optional if using W-7 plywood atmax. 24-inch ENRGY 3, H-Shield Dekfast #12 orTruFast 1 per z ft (homogeneous) or min. 0.5-inch HA using AA Ply) AA Base) One or SBS=AA, SBS-TA, 60,0 spans or Polytherm MP-3 with TruFast DP 1.33 Structodek High Density Fiberboard BP AA more BP=AA or APP-TA Roof Insulation APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 GM EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 5 of 26 '\J TRINITY I ER® •, TABLE 1C: WOOD,DECKS=NEW CONSTRUCTION, REROOF �TEaR-OFF) OR RECOVER SYSTEM TYRE C: M, t'cHANICALLYATTACHED INSULATION, BONDED ROOF•COVEV System Deck (Note 1) Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP Type Fasteners Attach Base Ply Ply Cap Ply No. Layer (psf) Min.19/32-inch (Optional) Min.0.5-inch Structodek High Density Dekfast Galvalume (Optional if (Optional if using AA W-8 plywood at max. One or more layers, Fiberboard Roof Insulation or min. 0.25- Steel Hex with 1 per 1.33 using AA Ply) Base) One or more BP -AA 565-AA, SBS-TA, APP- -82.5 24-inch spans anycombination, inch Dens Deck, Dens Deck Prime or Dekfast #12 DP ftZ BP -AA or APP-TA TA loose laid SECUROCK Gypsum -Fiber Roof Board (Optional) Dekfast Galvalume W-9 Min. 19/32-Inch plywood at max. One or more layers, IVIin.1.5-inch ENRGY 3, H-Shield or Steel Hex with Dekfast #12 DP or 1 per 1.33 SBS-SA (Optional) One or more SBS-SA, APP-SA, SBS- I, 82.5 24-inch spans any combination, Polytherm TruFast MP-3 with ftz SBS-SA or APP-TA TA or APP-TA loose laid TruFast DP ;' TABLE 1D WOOD;DECKS-NEW CONSTRUCTION, REROOF (TEaR=OFF}aR RECOVER •SYSTEM TYPED: PRELIMINARILY ATTACHED INSULATION,.MECHANICALLY'ATTACHED BASE SHEET,.BONDEDf ROOF COVER System Deck (Note Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP No. 1) Type Attach Base Fasteners Attach Base Ply Cap Ply (Psf) Polyglass Elastobase, Polyglass OMG Flat Bottom Plates Min.19/32-inch One or more layers, Prelim. Elastobase Poly, Polyglass G2 Base, (square) with Roofgrip. 12-inch o.c.,in 4-inch lap and 12- (Optional) One SBS-AA, W-10 plywood at max. any combination Attached CertainTeed Glasbase, Firestone MB #14, Dekfast Hex with inch o.c. in two, equally spaced, or more BP -AA SBS-TA, -52.5 24-inch spans Base, JM Perma-Ply 28, Tamko Glass Dekfast#14 or TruFast staggered center rows or APP-TA APP-TA Base or GAFGLAS #75 MP-3 with TruFast HD Min.19/32-inch One or more layers, Prelim. Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast 12-inch o.c. in 4-Inch lap and 12- One. or more SBS-SA, APP-SA, W-11 plywood at max. any combination Attached Elastobase#14 Poly with poly surface or TruFast MP-3 with inch o.c. in two, equally spaced, SB5-5A SBS-TA or -52.5" 24-inch spans TruFast HD staggered center rows APP-TA Min. 19/32-inch One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates 12-inch o.c. in 4-inch lap and 12- (Optional) One SBS-AA , { W-12 plywood at max. P Y� any combination Attached Elastobase Poly (square) with Roofgrip#12 Inch o.c, in two, equally spaced, or more BP -AA SBS-TA, -60.0 24-Inch spans P staggered center rows or APP-TA APP TA Min. 19 32-Inch One or more layers, Prelim. Polygiass Elastobase or Polygiass OIVIG Flat. Bottom Plates 12-inch o.c. In 4-inch lap and 12- One or more SBS-SA, APP-SA, W-13 P I ood at max. any combination Attached Elastobase Poly with poly top surface (square) with. Roofgrip #12 Inch o.c: in two, equally spaced, SBS-SA SB5-TA or -60.0" 24-inch spans staggered center rows APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity IERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 O' EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL16027-112 Revision 2: 09/25/2017 Appendix 1, Page 6 of 26 TRINITY j ER® TABLE 1E 1,' •WOOD DECKS.-,MEIN_CONSTRLICTION oe REROOF;(TEAB OFF) SYSTEM TV, E E: NON_ INSULAT „e' `,, • , , , ^ 7,' ED, MECHANICALMAVAGHED BASE SWEET, BONDED ROOF COVER System Deck (Note 1) Base Sheet Roof Cover (Note 25) MDP Base Fasteners Attach. Base Ply Cap Ply No. (Psf) Min.15/32-inch W-14 plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 9-inch o.c. at 2-inch la and 18-inch o:c. in two, P (Optional) BP -AA or SBS-AA, SBS-TA -45.0� Inch spans equally spaced, staggered center rows APP TA or APP TA Min. 15/32-inch W-15 plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in,two, (Optional) BP -AA or SBS-AA,-TA -52:5. inch spans equally spaced, staggered center rows APP TA or APP TA Min.19/32-inch Polyglass Elastobase, Polyglass Elastobase (Optional) One or W-16 plywood at max. Poly, Polyglass G2 Base, CertainTeed 32 ga., 1-5/8-inch diameter tin caps 8-inch o.c. in 4-inch lap and 8-inch o.c. in three, more AA or SBS-AA, SBS- 60.0 24 inch spans Glasbase, Firestone MB Base, JM Perma- with 11 ga. annular ring shank nails equally spaced, staggered center rows APP TAA TA, APP-TA Ply 28, Tamko Glass Base or GAFGLAS 975 W-17 Min.19/32-inch at max. Polyglass Elastobase or Polyglass 32 ga., 1-5/8-Inch diameter tin caps 8-inch o.c. in 4-inch lap and 8-inch o:c. in three, (Optional) One or SBS-SA SBS-SA, APP- TA 60:0 plywood Elastobase Polywith of to surface poly p with 11 a. annular ring shank nails g g equally spaced, staggered center rows q Y p gg more or SA, SBS or 24-inch spans APP-TA APP-TA Min.15/32-inch W-18 plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap o.c. at 2-inch lap two, (Optional) or SBS TA -90.0 inch spans d centernd equally rosin equally spaced, staggered center rows APP-TA or APPSBS-AA, or APP TA W-19 Min.19/32-inch plywood at max. Polyglass Elastobase or Polyglass 32 ga., 1-5/8-Inch diameter tin caps. 4-inch o.c. in 4-inch lap and 4-Inch o:c. in four, (Optional) One or SBS-SA SBS-SA, APP- TA Elastobase Polywith of to surface poly P with 11 a. annular ring shank nails. g g equally spaced, staggered q Y P ggered center rows more or SA, SBS or -97.5 24-Inch spans APP-TA APP-TA W-20 Min. 15/32-inch plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 64och o.c. at 2-inch lap and 6-Inch o.c. in three,. (Optional) BP -AA or SBS-AA, SBS-TA -105.0 inch spans equally spaced, staggered center rows APP-TA or APP-TA W-21 Min.19/32-Inch at max. Polyglass Elastobase or Polyglass 32-ga., 1-5/8-Inch diameter tin caps 6-inch o.c. in 4-Inch lap, and 6-inch o.c. in four, (Optional) One or BP SBS-AA, SBS- plywood 24-inch spans Elastobase Poly with it ga. annular ring shank nails equally spaced, staggered center rows more -AA or APP TA TA, APP-TA -112.5 Min. 19 32-Inch / 32 ga., 1-5/8-inch diameter tin caps SBS-SA, APP- W-22 plywood at max. Polyglass Elastobase or Polyglass with 11 ga. annular ring shank nails. 6-inch o.c. in 4-inch lap and 6-Inch o.c. in four, (Optional) One or SA, SBS-TA or -112.5 24-inch spans Elastobase Poly with poly top surface Note: Tin caps are to be primed with equally spaced, staggered center rows more APP-TA APP-TA ASTM D41 primer. Exterior Research and Design, I.I.C. d/b/a Trinity) ERD Evaluation. Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 O EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 7 of 26 TRINITY I EaD TABLEdE 2 WOOD DECKS -NE ON#OQ IDN!REROOF (TEAR OFF) oR'REcovER ^' SYSTEMTYPE EE;-NOh1-lNSULATED;.MECWANICACLY ATTACHED RASE SHEET, BONDED.ROOF,CO!/ER System Base Sheet Roof Cover (Note 15) MDP No. Deck (Nate 1) Base Fasteners Attach Base Ply Cap Ply (Psi) Min,19/32-inch Polyglass Elastobase, Polyglass Elastobase Poly, Polyglass G2 Base, CertalnTeed OMG Flat Bottom. Plates (square) with 12-inch o.c. in 4-Inch lap and 12-inch (Optional) One or SBS-AA SBS- W-1 plywood at.max: Glasbase,. Firestone MB Base, JM Perma- Roofgrip.#14, Dekfast with Dekfast o.c. In two, equally spaced, staggered more BP -AA or TA, APP-TA -52.5 24 inch spans Ply 28, Tamko Glass:Base or GAFGLAS 475 or TruFast MP-3 with TruFast HD center rows APP-TA Min. 19/32-inch Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast #14 or TruFast MP- 12-inch o.c. in 4-Inch lap and 12-inch One or more SBS- SBS-SA, APP- W-2 plywood at max. Elastobase Poly with poly top surface 3 with TruFast HD o.c:',in two, equally spaced, staggered SA SA, SBS-TA or -52.5* 24-inch spans center rows AP.P-TA. Min.19/32-Inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with 12-inch o.c. In 4-Inch lap and,l2-Inch (Optional) One or SBS-AA, SBS- W-3 plywood at max. Elastobase Poly Roofgrip #12 o:c. in two; equally spaced, staggered more BP -AA or TA, APP-TA -60.0 244nch spans center rows APP=TA Min. 19/32-inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with . 12-inch oc. in 4-inch lap and 12-inch One or more SBS- SBS-SA, APP- W-4 plywood at max. Elastobase Poly with poly top surface Roofgrip 912 o.c. in two, equally spaced„staggered SA SA, SBS-TA or 60.0* 24-inch spans center rows APP TA TABLE 1F OD DECKS rVIEW CONSTRUCTION oR REROOF (TEAR OFF) , %- °"SYSTEMTYPE F 'NON -INSULATED;,BOIVDED_ROOFCOVER System Deck Primer Roof Cover (Note 15) MDP Joint Treatment Base Ply Ply Cap Ply No. (Psi) r-- - Min 15/32-inchpiywood# -- -- � Optional ) D41- - - - - None__ SBS-SA"t i. Optionat')S6S SA or ( - - SBS SA AP.P_=SA;.SBS TA -- -- -� 90.0___ atmax. 24 inch spahsS '( .ASTM - d APP TA: i or APP TAB W 6 Min. 15/32-inch plywood (Optional), ASTM D41 Plywood joints are covered with 4-inch wide strips of TriBuilt SA TriBulltSA SBS Base (Optional) SBS-SA or SBS-SA, APP-SA, SBS-TA -97.5 at max. 24-inch spans I SBS Base, rolled into place to create continuous bond. APP-TA or APP-TA Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R2 for F1.16027-112 Certificate of Authorization #9503. O" EDITION (2017) FBC NON•HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 8 of 26