HomeMy WebLinkAboutLEETER-DOOR REPLACEMENTSCANNED PAUL WELCH INC.
BY Mechanical * Electrical * Civil Engineering
Lucie County 1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email pwelchinc@aol.com
une 13, 2018
Door Replacement
3206 S Lakeview Circle (Apt 103)
Fort Pierce, FL 34949
I Whom It May Concern:
lur office has calculated the required design pressure in accordance with ASCE 7-10 for
replacement of the doors at the above referenced address.
ind speed: Vuit: 165mph, Vasa: 128 mph
:posure: D
Lclosure Type: Enclosed
)or Size: Sliding Glass Doors 139" wide X 96" high
tantity of Doors: 1
cation: Rear of Unit / Zone 5 (Worst Case)
quired Design Pressure (Zone 5): +51.11-68.2 PSF Worst Case
to be installed shall be equal to, or exceed the required design pressures as listed
All installations shall be in accordance with FBC 2017 and manufacturer's
ttion instructions.
Door: PGT Sliding Glass Door 770 (Impact)
NOA# 17-0420.12 (+90 / -90 PSF)
you for your attention to this matter.
:ted by:
WELCH INC.
V
lch, P.E.
29945��