Loading...
HomeMy WebLinkAboutLEETER-DOOR REPLACEMENTSCANNED PAUL WELCH INC. BY Mechanical * Electrical * Civil Engineering Lucie County 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email pwelchinc@aol.com une 13, 2018 Door Replacement 3206 S Lakeview Circle (Apt 103) Fort Pierce, FL 34949 I Whom It May Concern: lur office has calculated the required design pressure in accordance with ASCE 7-10 for replacement of the doors at the above referenced address. ind speed: Vuit: 165mph, Vasa: 128 mph :posure: D Lclosure Type: Enclosed )or Size: Sliding Glass Doors 139" wide X 96" high tantity of Doors: 1 cation: Rear of Unit / Zone 5 (Worst Case) quired Design Pressure (Zone 5): +51.11-68.2 PSF Worst Case to be installed shall be equal to, or exceed the required design pressures as listed All installations shall be in accordance with FBC 2017 and manufacturer's ttion instructions. Door: PGT Sliding Glass Door 770 (Impact) NOA# 17-0420.12 (+90 / -90 PSF) you for your attention to this matter. :ted by: WELCH INC. V lch, P.E. 29945�� FILE