HomeMy WebLinkAboutPRODUCT APPROVAL ROOF UNDERLAYMENT0
BCIS Home I Log In i User
SCANNED
BY f
St. Lucie County 04
0
Hot Topic Submit Surcharge • Stats & Facts Publications Contact Us I BCIS Site Map Links i Search '
Product Approval Menu > Product or Application Search > Application List > Application Derail
FL #
FL16048-R6
Application Type
Revision
Cade Version
2017
Application Status
Approved
LRECEIVED
13 2018
unty, Permitting
Comments
Archived
-. � 4 COP
Product Manufacturer
Tri-Built Materials G � E
Address/Phone/Email PO Box 70
Rutherford, NJ 07070
(800) 516-1485
david.ruiz@tribuiltmg.com
Authorized Signature David Ruiz
david.ruiz@tribuiltmg.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford, NJ 07073
(201)842-2449
david.ruiz@tribuiltmateriaisgroup.com
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory
Undedayments
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
r') Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Robert Nieminen
the Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
,Quality Assurance Contract Expiration Date
07/18/2020
Validated By
John W. Knezevich, PE
�i Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL16048 R6 COI 2017 01 COI Nieminen odf
Standard
ASTM D1970
ASTM G155
FM 4474
FRSA/TRI April 2012 (04-12)
UL 1897
Year
2015
2005
2011
2012
2012
Product Approval Method Method 1 Option D
Date Submitted
09/25/2017
Date Validated
10/01/2017
Date Pending FBC Approval
10/03/2017
Date Approved
12/12/2017
Summary of Products
FL #
Model, Number or Name
Description
16048.1
TRI-BUILT Roof Underlayments
Self -adhering, modified bitumen roof underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16048 R6 II 2017 09 FINAL ER TRI-
Approved for use outside HVHZ: Yes
BUILT UNDERLAYMENTS FL16048-R6 odf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use
Evaluation Reports
of foam -on tile systems overtop the self -adhering
FL16048 R6 AE 2017 09 FINAL ER TRI-
underlayment for one particular application. See ER Section
BUILT UNDERLAYMENTS FL16048-R6.odf
5.6.4 for details. 2.) Refer to ER Section 5 for other Limits of
Created by Independent Third Party: Yes
Use.
Bach Next
Contact Us :; 2601 Blair Stone Road, Tallahassee FL 32399 Phone, 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail_ If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Departrnent with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick here .
Product Approval Accepts:
W ® ctkc
Credit Card
Safe
TRINITY # ERD
EVALUATION REPORT
TRI-BUILT Materials Group,
PO Box 70
Rutherford, N107070
(800)516-1485
EXTERIOR RESEARCH & DESIGN„LLC.
Certificate of Authorization 49503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report A42960.10.12-R6
FL16048-R6
Date of Issuance: 10/25/2012
Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction matehals in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
_�'J�•��aQ.54t�4 ''•r
Robert J.M. Nieminen P.E. .+'•`�s�- "`
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 09/25/2017. This does not serve as an electronically signed
document
CEwnFICAMON OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose. I
I
i
`' 'R TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the a Edition (2017) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1504.6
Accelerated Weathering
ASTM G155
2005
1507.2.4 / 1507.1.1,1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
Physical Properties
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties
S40540.11.13
11/19/2013
ERD (TST6049)
Physical Properties
S40540.03.14
03/26/2014
ERD (TST6049)
Physical Properties
S44870.04.14-2
04/02/2014
ERD (TST6049)
Physical Properties
S44870.04.14-3
04/02/2014
ERD (TST6049)
Physical Properties
544870.04.14-1
04/10/2014
ERD (TST6049)
Physical Properties
S44870.04.14-4
04/10/2014
ERD (TST6049)
Physical Properties
S43530.02.14-1-R1
05/14/2014
ERD (TST6049)
Physical Properties
543530.05.14
05/28/2014
ERD (TST6049)
Physical Properties
S40540.10.14
10/31/2014
ERD (TST6049)
Physical Properties
SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SC8520.04.15
05/27/2015
ERD (TST6049)
Wind Resistance
SC14045.05.17-R1
06/07/2017
UL, U.C. (QUA9625)
Quality Control
Multiple -Listing R16814
12/10/2015
UL, U.C. (QUA9625)
Quality Control
Service Confirmation
Exp. 07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970.
4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012.
4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS
modified bitumen roof underlayment; meets ASTM D1970.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is%was
used for permitting or design guidance unless retained specifically for that purpose. '
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product. i
Exterior Research and Design, LLC.
Certificate ofAuthorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION
TRI-BUILT Roof Underlayments; (800) 516-1485
I
Evaluation Report A42960.10AZ-116
FL1604&R6
Revision 6: 09/25/2017
Page 2 of 6
i
i
r
�4 'TRINITY I ER®
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1 ROOF COVER OPTIONS
Underlayment
Asphalt
Shingles
Nail -On Tile
Foam -on Tile
Metal
Wood Shakes
Slate
& Shingles
Tri-Built Sand-R SA Shingle
Underlayment
Yes
No
No
No
Yes
Yes
Tri-Built S/A HT TU
Yes
Underlayment
Yes
Yes
See 5.5.1
Yes
Yes
Yes
Tri-Built Smooth HT S/A
Underlayment
Yes
No
No
Yes
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved the adhesives / underlayment combinations.
TABLElArALLOWgBLETILEADt1E5NE/UNDERLl11liNENTCoMBINRT10Ns1
Adhesive
Florida Product Approval
Underlayments
ICP Adhesives Polyset® AH-160
FL6332
Tri-Built S/A HT TU Underlayment
Dow TileBond—
FL22525
Tri-Built S/A HT TU Underlayment
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU .Underlayment or Tri-Built Smooth HT:S/A
Underlayment applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group; LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or
OSB prior to installation of the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. .
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile. systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474, Appendix D or TAS 114, Appendix J.
I Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R6
Certi lcate of Authorization #9503 6'" EDITION (2-017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/Z5/2017
Page 3 of 6
TRINITY ERD
5.6.3 Bond to Mechanically Attached Base Laver:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ ASTM D226, Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT iTU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-
12).
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or
FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure = -45.0 nsf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer:
(Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered.
#2 Maximum Design Pressure = -67.5gsf:
Deck:
Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer:
Soprema Elastocol 600c
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered.
#3 Maximum Design Pressure = -150.0 asf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end -laps.
#4 Maximum Design Pressure = -60.0 nsf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1S17.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
Research and Design, LLC. Evaluation Report A42960.10.12-116
to of Authorization #J9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.16048-116
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 4 of 6
M M
.tr
'"_` TRINITY; ER®
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked With an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation:
5.8 Tile Slippage Limitations RAS 103 per FRSA/TRI April 2012 (04-12))-
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the lroof
tiles.
TABLEs2 TILE SUPPAGEUMRATIONS FOR DIRECT�DECK TILE �NSTALLAIION$ ' ;
Underlayment
Tile Profile
Staging Method
Maximum
Slope
Flat
Max.10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
Max. 10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high 6:12
on slope, as shown below)
`fit rr.zt %3 �'.7,,
r
Tri-Built S/A HTTU
Underlayment
- s
Lugged
F
Exterior Research and Design, U.C.
Cer6"ficote of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION
TRI-BUILT Roof Underlayments; (SM) 516-1485
Evaluation Report A42960.10.12-116
FL16048-R6
Revision 6: 09/2S/2017
Page 5! of 6
� l
TRINITY ! ERD
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri-Built Sand-R SA'Shingle Underlayment Tri-Built S/A HT TU Underlavment or Tri-Built Smooth HT S/A
Underlavment-
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile applications:
While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRI-BUILT Materials Group, LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications (Tri-Built S/A HT TU Underlayment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section S.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Gulfport, MS
9. QUALITY ASSURANCE ENTITY:
UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C.
Cerbfrcate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION
TRI-BUILT Roof Underlayments; (800) 516-1485
I
I
Evaluation Report A42960.10112-R6
FL16048-R6
Revision 6: 09/25/2017
Page 6 of 6
FICE USE ONLY:
TE FILED:
VISION FEE: ' 0
PERMIT # U 07
RECEIPT # -
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA A
FORT PIERCE, FL 34 -
(772) 462.15
APPLICATION FOR BUILDING PER IT
PROJECT INFORMATION
LOCATION/SITE
,11 ,.I,ii t jn ,
ADDRESS: 5��7
--
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
(ThalnarV,\g (kDVY) 40 SfCLM
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #:
BUSINESS NAME:
`.
QUALIFIERS NAME:
V1
ADDRESS:
CITY: X tnSYh (bC-.h
STATE: ---FI
PHONE (DAYTIME):
f -31
OWNER/BUIEL�D-ER INFORMATION:_I
L-..SM l +r 1
NAME: �' 1�
ADDRESS:
S f5kQ0
CITY:
STATE:
PHONE (DAYTIME:
ARCHITECT/ENGINEER INFORMATION:
NAME: - 0
�e h n c -
ADDRESS' 1
i' i
CITY: V7S L—.
STATE:
SLCCC. 9123109
Revised 06130117
�IAPML
L7'J Pry
STi.iJ�U'-C� CO CERT: #: act!57a
V4C 1- )C) i Vl
���r,rTiD
I XV4
FAX:
ZIP:
ZIP:
�i1i ll-Sa
REC"'EIVED
AUG 2 4 2018
Permitting Department
St. Lucie County, FL
0
•
PAUL WELCH INC.
Mechanical Electrical Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
E-mail pwelchinc@aol.com
M30-? - b3Zq
ST.. LUCIE COUI
BUILDING DIVIy�
REVIEWFi�
FOR Comm Am
DATE lZ4 raj
PLANS AND PERMIT
MUST BE KEPT ON JOB R
NO INSPECTION WILL BE A[
THEBE PLANS AND ALL PROPOSED WORK
August 22, 2018 MR 80JECT TO ANY CO"MEC)IONS
REQUIRED li'Iqu INISKCTORS THAT
Re: Smith Re -Roof UAY bE NECEN1RY IN ORDER TO
885 Nettles Blvd. COMPLY V4`116 ALL APPLICA.E CODES,
Jensen Beach, FL
SCOPE OF WORK:
Install new Metal Roof (Englert, Inc "Series 1101" FL # 11698.6) at above referenced address
over new underlayment, and existing plywood sheathing.
CONCFALED FASTENERS OR ATTACHMENTS
DESIGN, CRITERIA:
FBC 2017
ASCE7-10
PROJECT DATA:
BUILDING HIEGHT = 10'-0"
A= 3'
MEAN ROOF HIEGHT = <20'
ROOF ANGLE = 4:12
SHAPE = PITCHED GABLE
ADJUSTMENT FACTOR = 1.00
IMPROTANCE FACTOR = 1.00
WIND VELOCITY V ult=165MPH
WIND VELOCITY V asd = 128 MPH
EXPOSURE = D
ENCLOSURE CLASS = ENCLOSED BUILDING
INTERNAL PRESSURE COEFFICIENT = -0.18
APPLIED UPLIFT DESIGN PRESSURES PER ASCE (PSF):
ZONE 1 (Field) = -40.3
ZONE 2 (Perimeter/ Ridge) = -68.0
ARE THE RESPONSISII.liY OF THE
CONTRACTOR OF RECORD
ZONE 3 (Corners) = -99.8 , , , :1;1 r /T l -W616l :Inc.
885 Nettles Blvd. Jensen Beach, FL
vPu1slc,K"Er Reg. No. 29945
Sj,crlsAu�gust,22, 2018
P;e.299�
'� f f.OR� _ °f
�0
Lf` �+
II
to w
METAL ROOFING ATTACMMNT REOUIREMENTS:
Metal roofing to be attached with Pancake -Head wood screws #10 x 1" (minimum 3/16"
penetration through deck). Fasteners shall be placed adjacent to the integral snap lock every
panel with spacing as follows:
ZONE 1 (Field): FASTENER SPACING = 6" O.C. ,
ZONE 2 (Perimeter/ Ridge): FASTENER SPACING = 6" O.C.
ZONE 3 (Comers): FASTENER SPACING = 6" O.C.
Method #1 ACCEPTABLE FOR ALL ZONES
Method #1 Design uplift Pressure: -150 psf
Applied Design Uplift Pressure: -99.8
Therefore O.K.
UNDERLAYMENT•
Underlayment shall be Tri-Built, Roofing Products FL# 16048.1 "Tri-Built S/A HT TU".
While priming is optional, TRI-BUILT recommends priming the deck if the final roof cover is
not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back,
the first 3 ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible..
Once the entire length of membrane is in place, peel -off the release film diagonally while
holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal
seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6inches
and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -
laps shall be sealed using either heat -welding or hot air welding techniques. For Valleys and
Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over,
valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge,
in each direction. For valley's, apply the sheet starting at the lowest point and work upward.
DECK INSTALLATION:
Re -nail all plywood sheathing (15/32" thick minimum) with 8D ring -shank nails at 4" O.C.
perimeter and 6" O.C. field for all zones.
All Work 'to be in compliance with product approval (FL # 11698.6), (FL# 16048.1),
manufacturer's specifications, and the Florida Building Code 2017.
U�zlsWelch Inc..
r e
N6.29945
�. �ugusr22, 20l 8
885 Nettles Blvd. Jensen Beach, FL
2 of 3
. �;.^:« ; //r�� ' • FJ r Ski �' �r''�*
tLv re
A!:
a''
.4
ROOF ZONE PLAN
ZONE DESIGNA IYON aTPICAL)
Paul Welch Inc.
IM"Wd P.E. Reg. No. 29945
`",August.4�'7'—22, 2018
f
N
'885 Nettles Blvd. Jensen Beach, FL Tof 3
-7 Lo
----
-------------