Loading...
HomeMy WebLinkAboutNOA- l $07 - O-Zc( 9 RFCC'lV,�b - 41, ��aa�a� JU(I 2018 ��Auva Pe stimn9 Depart By Lucie Countyent MIAMI-DADS COUNTY M PRODUCT CONTROL SECTION al. Lucia County 11805 SW 26 Street. Room 208 D PARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 B ARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 QTICE OF ACCEPTANCE NOA ww•w.miami(lade.gov/econoinv G F 1 ampus Drive P sippany, NJ 07054 S OPE: Th s NOA is being issued under the applicable rules and regulations governing the use of construction materials. The do umentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be us in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). Th NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas ,other than Miami Dade County) reserve the right to have this pro uct or material tested for quality assurance purposes. If this product or material fails to perform in the accepted ma ner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or sus end the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if i is determined by Miami -Dade County Product Control Section that this product or material fails to meet the req irements of the applicable building code. Thi product is approved as described herein, and has been designed to comply with the Florida Building Code incli, ding the High Velocity Hurricane Zone of the Florida Building Code. : GAF Woodland® Shingle LAP ELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following state ent: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in th,� applicable building code negatively affecting the performance of this product. '114MINATION of this NOA will occur after the expiration date or if there has been a revision or change in the mat ials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for s les, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of th �,s NOA shall be cause for termination and removal of NOA. AD ERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expi II tion date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its Entirety. 1NS IECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall a available for inspection at the job site at the request of the Building Official. This OA renews NOA No. 14-1022.23 consists of pages 1 through 4. The s bmitted documentation was reviewed by Alex Tigera. F , 1� NOA No.: 16-1012.19 Expiration Date: 04/05/22 Approval Date: 03/23/17 Page 1 of 4 m [WING ASSEMBLY APPROVAL ;gory: Roofing Category: Asphalt Shingles erial: 4-Tab i Type: Wood PE: approves GAF Woodland® as manufactured by GAF as described in this Notice of Acceptance, designed. to ly with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. )DUCT DESCRIPTION: lanufactured by Dimensions Applicant Woodland® Shingle 17" x 40" MINUFACTURING LOCATION: 1. II Mt. Vernon, IN Test Product Specifications Description TAS 110 Fiberglass reinforced heavy weight asphalt roof shingle, with 4-tabs. EV[DIINCE SUBMITTED: Test Aeency Test Identifier PRIhalt Technologies GAF-321-02-01 Undriters Laboratories, Inc. I ICA48725 Undriters Laboratories, Inc. I ICA48725 Undriters Laboratories, Inc. 11 CA48725 Test Name/Reyort Date TAS 100 10/31/11 ASTM D 3462 12/09/11 TAS 107 12/09/11 ASTM E 108 12/09/11 LI ITATIONS: 1. ire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire tings of this product. 2. ;all not be installed on roof mean heights in excess of 33 ft. 3. 1products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and le 61 G20-3 of the Florida Administrative Code. I NOA No.: 16-1012.19 Expiration Date: 04/05/22 Approval Date: 03/23/17 j Page 2 of 4 i 2.1 3. 4. 5. STALLATION: Shingles shall be installed in compliance with Roofing Applications Standard RAS-115. Flashing shall be in accordance with Section 9.3 Option `B" (step-flashings) of Roofing Applications Standard RAS-115. The manufacturer shall provide clearly written application instruction. Exposure and course layout shall be in compliance with Detail "A", attached. Nailing shall be in compliance with Detail `B", attached. L BELLNG: Sh ngles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city. and state of in ufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade Co, ntv Product Control Seal as shown below. A 1. 2. LDING PERMIT REQUIREMENTS: ication for building permit shall be accompanied by copies of the following: This Notice of Acceptance. Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this material. NOA No.: 16-1012.19 f Expiration Date: 04/05/22 Approval Date: 03/23/17 Page 3 of 4 .sktwduE INSTALLATION :State at;althar• rake and lay In;eltherdlrectlorf First Course: :Start with.full shingle Trirrt'�" (3rnm)`nbtcfi Sect nd.Course: --- Trlm 5" (127ni!h) ;off ilot shingle., off first shingle Fourth Course: Trim 15"' n mm ;offitrst.stifngfe .(43. DETAIL A COURSE LAYOUT DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN kNHANEED,NA1L1Kq,PATFERN,-1stx mils pt rshirigte END OF THIS ACCEPTANCE fistcourse of shirigles -19mm) over eave. and drip Oge. A. 0gnfnent.Notcli I i NOA No.: 16-1012.19, Expiration Date: 04/05/22� Approval Date: 03/23/17, Page 4 of 4