HomeMy WebLinkAboutPRODUCT APPROVALFlo ida Building Code Online; - z Page 1 of 2
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
FL1654-R22
Revision
2017
Approved
IN]
POLYGLASS USA
1111 W. Newport Center
ST LUCIE COUI
BUILDING CMS
FOR COMPLI
REVIEWED BY
DATE 7% (
PLANS AND P
MUST BE KEPT O
NO INSPECTION WI
Deerfield Beach, FL 33442
(954) 233-1378 Ext 242
alender@polyglass.comTHESE- PLANS
vAND
ppALL
/oPROPOSED WORK
Ariel Lender ARE SUBJECT 1 O M V1 IRIECTIO S
alender@polyglass.com REQUIRED 9V HaD IISrEC T ORS THAT
Maury Alpert IUY BE NECES&M IN ORDER TO
ills W. Newport Center 1:60Jllrlbl pi In ALL Appl. ckNIE CODES.
Deerfield Beach, FL 33442
(912) 429-8610
MAlpert@polyglass.com
Quality Assurance Representative Ariel Lender CONCEALS FASTENERS OR ZIAC BEN S
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442 (954) 233-1230 ARE THE RESPONS1810 OF THE
/�,e
ALender@polyglass.com CONTRACTOR OF RECORD
Category Roofing V1/II iy�
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/06/2018
Validated By John W. Knezevich, PE
1/1 Validation Checklist - Hardcopy Received
Certificate of Independence FL1654 R22 COI 2017 01 COI Nieminen odf
Referenced Standard and Year (of Standard) Standard Year
ASTM D6162 2008
ASTM D6163 2008
ASTM D6164 11
ASTM D6222 2011
ASTM D6509 4I 09
P V
FM 4470 LI _
_� 0 i s
FM 4474 2011
UL1897 2012
/www. floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgvgqu2w%2bn... 7/31 /2018
Building Code Online Page 2 of 2
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
09/14/2017
09/15/2017
09/22/2017
12/12/2017
FL #
Model, Number or Name
Description
1654.1
Polyglass SBS and APP
SBS and APP modified bitumen roof systems
Modified Bitumen Roof
Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL1654 R22 II 2017 09 FINAL Al ER POLYGLASS MODBIT FL1654-
R22.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
"Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this application
Evaluation Reports
relates to one particular assembly over concrete
FL1654 R22 AE 2017 09 FINAL ER POLYGLASS MODBIT FL1654-
R22.Dd
deck. Refer to the ER Appendix for other systems
and deck types. 2.) Refer to ER, Section 5 for
Created by Independent Third Party: Yes
other Limits of Use.
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an WEED employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click here.
Product Approval Accepts:
• = W ® eChe'ck -sfi
Credit•
Safe
secuiritxM L-'fIt1 CS'
hgs1�/www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bn... 7/31 /2018
PPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND+UPLIFT RESISTANCE`
Table
Deck
Application
Type
Description
Page
1A
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
16-1
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-9
113-2
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
30-11
1C
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
it
1D
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
12-13
1E
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
14-15
1F-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
16-18
1F-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
19-21 _ -
1G
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
21
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22-24
2B
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
25-28
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
29-31
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
32-40
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
40
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
41-42
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
43
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
44-46
SA
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
47
5B
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
48
5C
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
49
5D
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
49
SE
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
49
6A
Gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
50-52
6B
Gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
52
6C
Gypsum
Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
53
61)
Gypsum
Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
53
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
54-58
7B
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
58
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
➢ Wood: Minimum 0.75-inch penetration.
➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the OA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
Exterior Research and Design, LLC. d/b/a Trinityl ERD Evaluation Report P9290.02.08-R20 for FL3654-R22
Certificate of Authorization #9503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 —_ Appendix 1, Page 1 of 58
4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions.
➢ Hot asphalt (HA): Full coverage at 25-30 Ibs/square.
➢ Dow INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c.
➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ Millennium PG-1 Pump Grade Adhesive (M-PGi): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ OMG OlyBond 500 (013500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced.
➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
➢ ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c.
➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, board joints shall be staggered.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table:
➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick)
➢ Millennium PG-1 Pump Grade Adhesive (M-PG3): MDP -157.5 psf (Min. 0.5-inch thick)
➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3)
➢ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL)
➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3)
➢ OMG OlyBond 500 (06500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II)
➢ ICP Adhesives & Sealants CR-20: MDP -117.5 psf (Min. 1.0-inch thick)
8. Bonded polyisocya n u rate insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches.
For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1.
Exterior Research and Design, U.C. d/b/a Trinity) ERD Evaluation Report P9290.02.08-1120 for FL36S4-R22
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1,-Page 2-of S8
ERD
15. Unless otherwise noted, refer to the following references for bonded base, r)ly or car) sheet aoolications
TABLE 1: POLYGLASs ROOF COVERS
Reference
Layer
Material
Application
BP -AA
Base Ply
One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II
(Base and Ply sheets, Asphalt-
Ply
One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
Hot Asphalt at 20-40
Applied)
PP )
Note:
Asphalt -applied sheets or insulation shall not be applied to poly film surfaced membranes.
Ibs/square
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 Type II, Polyglass HT Base 650
SBS-CA1
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 Type II, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastoshield
PG350 at 1.5-2.0
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
gal/square
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 Type II
SBS-CA2
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield
Polyplus 35 at 1.5-2.0
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
gal/square
Base Ply or Ply
One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex
SBS-AA
S6 Type II, Polyglass HT Base 650
Elastoflex V, Elastoflex VG, Elastoflex VG
Hot Asphalt at 20-40
(5B5, Asphalt Applied)
Cap Ply
FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G,
Ibs/square
Elastoshield TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Note:
Asphalt -applied sheets or insulation shall not be applied to poly film surfaced membranes.
Base Ply or Ply
One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex 56, Elastoflex S6 Type Il, Polyglass HT Base
SBS-TA
650
(SBS, Torch -Applied)
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex 56 Type II, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G,
Torch -Applied
Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed)
Base Ply
One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR
SBS-SA
Cap Ply
Elastoflex SA P, Elastoflex SA P FR, Polyrefled
(SBS, Self -Adhering)
Note:
Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
Elastobase (poly/sand) or Elastobase (poly/poly).
APP-CA1
Cap Ply
Polyflex G FR
PG350 at 1.5-2.0gal/square
APP-TA
Base Ply or Ply
One or more plies Polyglass APP Base, Polyflex, Polybond
(APP, Torch -Applied)
Cap Ply
Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR
Torch -Applied
APP-SA
Cap Ply
Polyfiex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool
(APP, Self -Adhering)
Note:
Unless otherwise noted, permissible membrane substrates forAPP-SAare limited to the SBS-SA Base Ply options herein,
Self -Adhering
Elastobase (poly/sand) or Elastobase (poly/poly).
16. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance.
associated with coating usage.
> PG200 Non Fibered Roof Coating;
> PG300 Fibered Roof Coating;
> PG600 Non-Fibered Aluminum Roof Coating;
> PG650 Fibered Aluminum Roof Coating;
> PG700 High Quality Elastomeric Roof Coating or KM Acryl 25;
> PG700QS (Quick Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (for granule -surfaced APP or SBS only);
> PG800 Asphalt Emulsion Roof Coating;
> Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
> Polyplus 65 Premium Fibered Aluminum Roof Coating;
> Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15;
> Polybrite 70QS (Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-Q$ (for granule -surfaced APP or SBS only);
> Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
Exterior Research and Design, LLC. d/b/a Trinity) ERD
Certificate of Authorization #9503 6Tx EDITION (2017) FBC NON-HVHZ EVALUATION
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1730
Refer to current Roofing Materials Directory for fire ratings
Evaluation Report P9290.02.08-1120 for FL1654-R22
Revision 20: 09/12/2017
Appendix 1, Page-3 of 58
17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements.
18. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A
applies:
VAPOR BARRIER OPTIONS;: STRUCTURAL CONCRETE DECK, ADHERED INSULATION. PER TABLE 3A
Option #
Primer
Vapor Barrier
Insulation Adhesive
MDP (psf)
Type
Attach
VB-1.
PG100
Elastoflex SA V Plus
Self -Adhering
Inta-Stik or CR-20, 12-inch o.c.
-60.0
VB-2.
PG100
Polyglass APP Base
Torch -applied
Inta-Stik or CR-20, 12-inch o.c.
-75.0
VB-3.
PG100
Elastoflex SA P
Self -Adhering
Insta-Stik, 12-inch o.c.
-75.0
VB-4.
PG100
Elastoflex SA P
Self -Adhering
Millennium One Step Foamable Adhesive, 12-inch o.c.
-157.5
VB-S.
PG100
Elastoflex SA P
Self -Adhering
CR-20, 12-inch o.c.
-270.0
VB-6.
PG100
Elastoflex SA V Base, Elastoflex SA V FR Base,
Elastoflex SA V Plus, Elastoflex SA V Plus FR
Self -Adhering
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20, 12-inch o.c.
-290.0
19. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
i
Exterior Research and Design, U.C. d/b/a Trinity I ERD Evaluation Report P9290.02.08-R20 for FL1654-RZ2
Certificate of Authorization #9503 6rx EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1730 Appendix 1, Page 4 of 58
RECEIVE?
JUL 3 0 %)-!'
{ `', O /,�^ r 51. Lucie County, Permittina
U Lj1,`�I]
TRINITY I
ERD
TABLE IF-2: WOOD DECKS— NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER
System
No.
Deck (Note 1)
Base Sheet
Roof Cover (Note 15)
MOP
Type
Fasten Attach
Base Ply Cap
(psf)
SELF -ADHERING BASE PLY:
W-136
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14
12-inch o.c. in 4-inch lap and 12-inch o.c. in two
SBS-SA, APP-SA, SBS-
inch plywood
(poly -film top)
or Trufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
SBS-SA
TA, APP-TA
52.5"
W-137
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14
12-inch o.c. in 4-inch lap and 12-inch o.c. in two
inch plywood
(poly -film top)
or Trufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
Polyflex SA Base
APP-TA
-52.5"
W-138
Min. 19/32-
inch plywood
Elastobase, Elastobase P
(poly -film top)
OMG Flat Bottom Plates (square) with Roofgrip #12
12-inch o.c. in 4-inch lap and 12-inch in two
o.c.
SBS-SA
SBS-SA, APP-SA, SBS-
60.0"
(2), equally spaced, staggered center rows
TA, APP-TA
-
W-139
Min. 19/32-
inch plywood
Elastobase, Elastobase P
(poly -film top)
OMG Flat Bottom Plates (square) with Roofgrip #12
12-inch o.c. in 4-inch lap and 12-inch o.c. in two
Polyflex SA Base
APP TA
(2), equally spaced, staggered center rows
-60.0"
TABLE 1G: WOOD DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF)
SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER
System
Deck (Note 1)
Primer
Roof Cover (Note
15)
No.
Joint Treatment
Base Ply
Ply
Cap Ply
MDP (psf)
Min. 15/32-
inch inch I
plywood
None
None
SBS-SA
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
90.0
TA, APP-TA
TA, APP-TA
W-141
Min.15/32-
inch plywood
(Optional) PG100
None
Polyflex SA Base
(Optional) APP-TA
APP-TA
-90.0
W-142
Min. 15/32-
inch I
plywood ywood
PG100
None
SBS-SA
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
TA, APP-TA
TA, APP-TA
-97.5
W-143
Mch
(Optional) PG100
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Base or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
plywood
place to create continuous bond.
Elastoflex SA V FIR Base
TA, APP-TA
TA, APP-TA
-97.5
W 144
inch plywood
inch plywood
WB-3000
None
SBS-SA
(Optional)
SBS-SA, APP-SA, SBS-
105.0
TA, APP-TA
W-145
Min. 15/32-
(Optional) PG100
Plywood joints are covered with 4-inch we strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Plus or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
inch plywood
place to create continuous bond.
Elastoflex SA V Plus FR
TA, APP-TA
TA, APP-TA
-135.0
W-146
Min. 15/32-
(Optional) PIS 00
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
inch plywood
place to create continuous bond.
Polyflex SA Base
(Optional) APP-TA
APP-TA
-135.0
Exterior Research and Design, I.I.C. d/b/a Trinity IERD Evaluation Report P9290.02.08-1120 for FL3654-R22
Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 21 of 58