Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLOWER DOOR TEST
_ Planning & Development Services Building & Code Regulation DivisionICOUNTY 2300 Virginia Ave, Rm 201 1ttin9 Deer nt Fort Pierce, FL 34982 SCANNED perAq Phone:772-462-2165 Fax:772-462-6443BY St. l ude county BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method Dal Ile: 3 ( Permit #: 1 / o ress: Co �.? hl.r_S 4o vw_ b (f • f i - P I a-vr Cje,- ction: (�) New Construction — Complete ( ) Existing — After Addition ;e Infiltration Test Results SLC Climate Zone 2 (50) = Test Date: me= VS-1 A1 (50) = CFM (50) x 60 / Volume = Mechanical Ventilation required less than 3 ACH ing results must be & ACH (50) or less (%) Pass ( ) Fail FBC, (Energy The wilding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour fn Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blow r door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Secti n 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an appr 'ved third party. A written report of the results of the test shall be signed by the party conducting the test and provi ed to the code official. Testing shall be performed at any time after creation of all penetrations of the building ther ,al envelope. FBC, Residential III Wherr the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a press Ore of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testirli Company Comp ny Name: Address: 6 b ! N 1i l W Mn6 r kj (fV . � FL I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requi4ment,5..ip accordance with Se4iog R402.4.1.2 Climate Zone 2. v r Name: G Sods CG' 11l ��-C. LicensVCertification #: eJ {' -1— S—© (P12 4L ( n[ W, __1 Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 772-462-2165 Fax 772462-6443 FBC ENERGY CONSERVATION CODE Dud Sealing Certification Prescriptive and Performance Method -- RE FILECOP"'V Permitting Department St. Lucie county ` Permit #: ' Or) (93 5 A l� Lot #: � sly- ictor: - L4.9 cio , ' Address: 5-7/3 _ D � �C �S` o t Or, R A' ✓�fl — 'I Post Construction Test 01nditions• .3 l �q \ 60 I Temperature (F):15 )r Temperature (F): -7 6i ❑ Rough -in Test Floor Area (ft2): Primary Location of Supply Ductwork Primary Location of Return Ductwork • w 14{GI LC.1{O{ C ICM VYWIYC D ct Leakage: ❑ DefauI ❑ Prop. Leak Free Proposed On Te I t Pressure: � J (Pa) B�seline Duct Pressure (optional) (Pa){ �, : Q e Q 1-7 Press. Pa Flow Ring Fan Press Flow In I (Pa) Total Leakage (cdm): Total Leakage per 100 sgft: .56' S-0('P • CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sgft. Company O Cl iy Name: _ l'�t / Address: �� Id� {'� /Yt tr 1`'� CV,FL certify that the above Duct Seali 'g Leakage results demonstrate compliance with 5"h Edition FBC Energy Conservation requirements in accordance with 7R4 .2. re: �i 2 /_ me: L nG�-2l License/Cert�cate#: �i.J��L �� �2_