ROOF & WALL SHEATHING
FASTER. TIGHTER. ENERGY EFFICIENT.
FROM THE
CREATORS
)6
�3 , oWvanTech'
another innovation fi-oln
ZIP System®Roof & Wall Sheathing
INSTALLATION MANUAL
Contents
02 ZIP System° Sheathing Installation On Roofs
' 03 ZIP System- Tape Installation -
Roof Panel Seams
04 ZIP System'M Tape Installation -
Roof Panel Seams (continued)
05 Roof Covering Installation Instructions
06 ZIP System® Roof & Wall Sheathing Installation
07 ZIP System'"" Tape Installation - Panel Seams
ATTENTION: This installation guide is intended to provide general
information for the designer and end user. The following guidelines
will help you safely and properly install the ZIP System® Roof & Wall
wall sheathing. We urge you, and anyone installing this product, to
read these guidelines in order to minimize any risk of safety hazards
and to prevent voiding any applicable warranties. This manual is
a, general installation guide and does not cover every installation
condition. Proper installation shall be deemed to mean the most
restrictive requirement specified by Huber Engineered Woods (HEW),
local building code, engineer or architect of record or other authority
having jurisdiction. You are fully and solely responsible for all safety
requirements and code compliance. For additional information contact
Huber Engineered Woods LLC.
ZIP System® Roof & Wall Sheathing Safety Guidelines
Follow all OSHA regulations and any other safety guidelines and safety
practices during installation and construction.
Use approved safety belts and/or harnesses or otherfall protection equipment.
Install ZIP System panels and tape only in dry conditions and on dry surfaces.
Do not install in rain, snow, frost or other slippery conditions.
Wear rubber -soled or other high -traction footwear while installing ZIP System
sheathing in a roof application. Do not wear footwear with wom soles or heels.
Ensure the roofing surface is free from oil, chemicals, sawdust, dirt, tools,
electric cords, air hoses, clothing and anything else that might create a
tripping hazard.
Install temporary toe boards along the ZIP System sheathing roof surface.
What Is ZIP System® Roof & Wall Sheathing?
ZIP'System Roof & Wall sheathing is code -recognized as a wood structural
panel, roofing underlayment ([CC -ES ESR-1473), water -resistive barrier
and,air barrier (ICC-ES ESR-1474). ZIP System Roof & Wall sheathing
has a built-in moisture barrier that lets you say good-bye to building paper
or housewrap on the walls and felt paper on the roof.* Simply install the
panels, tape the seams, and you have a structural wall sheathing, water -
resistive barrier and air barrier or a structural roof sheathing and roofing
underlayment all from one product.
xa
TM
ROOF & I I L sHEAT"'No
I
FASTER. TIGHTER. ENERGY EFFICIENT.
08 ZIP System® Roof & Wall Sheathing - Wi
Installation Flanged Windows & Brick Mc
09 ZIP System® Roof & Wall Sheathing -
Installation Brick Mould Windows (con
10 ZIP System® Roof & Wall Sheathing -
Penetration Openings
11 ZIP System® Roof & Wall Sheathing
Installation Details
12 ZIP System° Roof & Wall Sheathing
Installation Details (continued)
Windows
inaow
cued)
ZIP System Roof & Wall sheathing can be used with a ran'P of exterior
claddings and roof coverings. Approved wall coverings iIIpclude brick,
vinyl, stone, wood fiber cement, wood and cedar, shakes, traditional hard
coat stucco and specified drainable .EIFS applications, hlowever it is
not recommended for use with adhesively attached EIFS. A�proved roof
coverings include asphalt -fiberglass shingles, metal tiles and pan, els, clay and
concrete tiles, slate and slate -type shingles and wood shakes Land shingles.
Follow all cladding and roof covering manufacturer's installation instructions.
ZIP System Roof & Wall sheathing can be used on buildings of Type
III (Roof Applications ONLY) and Type V construction and lonstruction
permitted under the IRC.
ZIP System® Roof & Wall Sheathing Includes: - 11
ZIP System sheathing panels with built-in moisture barrier with preprinted
fastening and tape guides
ZIP System tape
Storage and Handling
Set panel stack on three supports (stickers) to keep off the gF,ound.
Outdoors, cover panels loosely with waterproof protective material.
Anchor covers on top of the stack, but keep away from sides and bottom
to assure good air circulation. Ist
In high moisture environments, cut banding on the panel stacl to prevent
edge damage.
ZIP System® Roof & Wall Sheathing Notes and Limitations:
Do not use on roofs with slopes less than 2/12. i
Do not use abutted against general stone or masonry without roviding a
minimum of a 1/2" gap.
Do not install ZIP System tape in temperatures less than 20° F,
ZIP System products are not recommended for manufactured housing
applications that are built under a federal building code ad stered by
the U.S. Department of Housing and Urban Development (HUD).
i_I
Do not use panel edge clips (H-Clips) with ZIP System Roof & Walllsheathing
without expressed written approval from Huber Engineered Woods.**
Do not use ZIP System tape to permanently seal around ciry�ular roof
projections (plumbing vents, pipes, curved walls, etc.) III
Contents (continued)
Wall Coverings
- ZIP System Roof & Wall sheathing should be covered with the finished
roof covering or exterior cladding within 180 days of installation.
- Finished roof and exterior cladding products should be installed per
the manufacturer's installation instructions.
- Per the recommendation of the Western Red Cedar Lumber Association
and the U.S. Forest Products Laboratory, wood siding should be primed
before installation.
When original roofing or claddings are removed and replaced on existing ZIP
System sheathing, the roof or wall should be covered with an additional
roofing underlayment or water resistive barrier prior to installation of the
new finished roofing or cladding.
Note: In cladding systems requiring multiple layers of water -resistive barriers,
like traditional hard -coat stucco, ZIP System sheathing is intended only to
replace the first layer.
Wet Blown Cellulose Insulation
- In addition to following manufacturer installation instructions, we recommend
a maximum moisture content of the cellulose of less than 2 % measured at
the inside surface of the ZIP System panel before closing l�he wall cavity.
Secondary Coatings Iil
Do not apply secondary coatings or treatments to ZIP Syste Roof & Wall
sheathing panels with the exception of the following:
HEW approved fire resistant coatings. Fire resistant co tings must be
tested and approved by HEW for use with ZIP System panels.
Field applied water-soluble borate insecticide or fungicide treatments
applied to the non overlay side of the panel. See technicAl tip, "Termite
Treatments on ZIPS stem Roof & Wall Sheathing," Y
y g," on zipsystem.com for
more information.
Permeable laminated radiant barrier foil or paint. For a radio t barrier foil or
coating to be considered permeable, it must have an applied'permeance of
five perms or greater as tested by the ASTM E 96 wet cup s'andard. For a
radiant foil, the permeance evaluation would include any a io hesive and/or
backer used to laminate a foil. For a radiant paint/coating, the permeance
evaluation should be conducted at the applied thickness of the�paint/coating.
ZIP System Roof and Wall sheathing replaces only the first layer in multi•underlayment systems.
Edge support is not required by code with 1/2 (32/16 span rated) and 5/8 (40/20 span rated) performance category sheathing if the framing does not exceed 24' o.c.
and the total load does not exceed 93 psf for 1/2 and 156 psf for 5/8 performance categories. This is based on U180 deflection criteria for total load.
• ' ZIP Sysiem® Roof & Wall Sheathing Installation Manual
02
ZIP System® Sheathing Installation on Roofs
Overview: ZIP System Roof & Wall sheathing is composed of ZIP System panels and ZIP System seam sealing tape. ZIP System" Roof & Wall Sheathing
panels should be fully installed before the seam sealing tape is applied. In general, the ZIP System roof sheathing panels should be installed from Itt�e lowest point
on the roof to the highest. It is at the discretion of the installer whether to apply tape from the top down or from the bottom up. However, working fllom the highest
sections of the roof and working down will minimize foot traffic on the tape. The following installation steps are presented as guidelines and a general i outline of
the installation process. These are manufacturer installation recommendations— please visit zipsystem.com for a library of flashing and installation tletails. You are
fully and solely responsible for all safety requirements. Good construction and safety practices should be followed at all times. 1
Step 1.
11
- Ensure that the panel surface is dry and clean of any nails, sawdust, or+s9,
other debris or protrusions prior to installing or walking on the panels.
- After ensuring compliance with all OSHA and local code safety
guidelines, install ZIP System sheathing panels with the moisture
barrier surface facing outside. The long edge (8') should be oriented
perpendicular to the framing members, and panels should be installed
with the 4' edge seams staggered a minimum of 24".
h
- 1/8" spacing between square edges of all adjacent panels is recommended,
i
in accordance with industry standards for wood sheathing. (Tongue &
i
8' Panel Edges 4' Panel Edges
Groove panels are designed to self -space and do not require manual
1/8" 1/8" J
spacing on the 8' edges.)
I
S
The unique edge profile is Maintain 1/8" space
designed to accommodate where 4' edges meet.
incremental panel Unique edge profile is o
expansion and does not 8' edges only. '
require manual gapping
along the 8' edges.
i
I'
Step 2.
- Ensure that ZIP System panels span at least three framing members and
a framing member supports the entire 4' edge of the panels.
- Fasten the ZIP System Roof & Wall sheathing panel to the framing
members with code approved fasteners spaced at the appropriate
edge and intermediate spacing. It is the responsibility of the general
contractor to verify proper fastener type and spacing prior to installation.
- Apply the fasteners 3/8" from the panel ends and corners.
I
-' An ideal installation would be where fastener heads are flush with the
panel surface. However, due to variations in materials and limitations
V
on equipment, this may be difficult to achieve in some situations. It
is not required to tape over overdriven fasteners unless the fastener
head creates a hole through the entire panel thickness. Please see
I
the technical tip, "Overdriven Fasteners in ZIP System Roof and Wall
I
Sheathing," for more information.
lu
Step 3.
Install temporary toe boards as necessary when applying the ZIP System
sheathing panels up the slope of the roof planes.
I
h
i
I
i
i
I
03
ZIP System'" Tape Installation - Roof Panel Seams
Apply ZIP System tape after all ZIP System Roof & Wall sheathing panels are fully fastened to roof -framing members. Only ZIP System tape sh iuld be used to
seal the seams of ZIP System panels. Ensure that the panel surfaces are dry and free of any nails, sawdust and other debris, or protrusions. Avoid stepping
on tape in high temperature environments. ZIP System tape is a contact tape that requires pressure for an adequate seal.
Step 1.
- Apply ZIP System tape to every vertical and horizontal panel seam. It is
at the discretion of the installer whether to apply tape from the top down
or from the bottom up. However, working from the highest sections of
the roof and working down will minimize foot traffic on the tape.
- Ensure that the tape is centered over the seam within +/- 1/2" to provide
adequate coverage and to ensure that wrinkles in the tape are minimized.
- Ensure that tape lengths are continuous across the 8' horizontal edge
of the panels. If splices are unavoidable, create an overlapping splice
of at least 3". Apply moderate pressure onto the surface of the tape to
ensure a secure bond between the panel and the tape.
- Use ZIP System tape gun or tape roller to apply pressure to the tape
and smooth out any wrinkles.
- Take special care to remove any voids and/or trapped air at splice
areas and T-joints.
(Step 2.
For valley areas of framing, we recommend you use 6" wide ZIP System
tape. This tape is wider than panel seam tape and is designed to give you
optimal protection in valley areas.
- Starting from the bottom and working your way up, apply one continuous
i
piece of 6" tape so that the center of the tape is over the valley seam.
Use the tape gun or tape roller to apply pressure to the tape to ensure
proper contact with the panel and to eliminate any wrinkles that might
I have occurred in the tape. Take special care to seat tape completely
into the valley.
Note-
1 It is important to pay extra attention to valley taping as water is
directed toward the valleys during rain events.
-' Self -adhering ice and water barriers may be required by code. ZIP
System tape is not considered a replacement for self -adhering ice
and water barriers. Therefore, when self -adhering ice and water
barriers are required, they should be installed in addition to ZIP
System tape.
2
q,
PG ape Plea w 3o�ierla " SecondaT,a epPt�c`
,ZIP System® Roof & Wall Sheathing Installation Manual
i
104
ZIP System'"Tape Installation -Roof Panel Seams (continued)
I �I
Step 3.
- If 6" ZIP System tape is not available, use two continuous pieces of 3.75"
ZIP System panel seam tape over the entire length of the valley seam,
overlapping the pieces on the valley seam by at least 1 ".
}
- Starting from the bottom, install the first piece of tape overlapping the
valley seam by at least 1 ".
First piece
I" Use the tape gun or tape roller to apply pressure to the tape to ensure
of,tape
i proper contact with the panel and to eliminate any wrinkles that might
have occurred in the tape.
- Apply the second piece of tape, overlapping the first piece in the valley
seam by 1".
;
- Repeat use of the tape gun or roller to make'sure the tape is adequately
'
adhered and tightly pressed into the valley seam.
Second piece
Note:
of tape
It is important to pay extra attention to valley taping as water is
directed toward the valleys during rain events.
- Self -adhering ice and water barriers may be required by code. ZIP
System tape is not considered a replacement for self -adhering ice
and water barriers. Therefore, when self -adhering ice and water
1 barriers are required, they should be installed in addition to ZIP
1 overlap
System tape.
I
i
Step 4.
- To provide temporary weather protection to roof/wall intersections
4
of dormers or other wood -sheathed projections, apply 2" of the tape
width up the vertical projection from where it intersects with the roof.
j The remaining tape width can be adhered to the ZIP System roof
sheathing panels.
j- Use the tape gun or tape roller to apply pressure to the tape and smooth
out any wrinkles.
Step 5.
Install ZIP System tape over hips and ridges by centering the tape over
{ the peak seam. Apply tape in sufficient length to completely extend the
length of the hip or ridge.
Starting from the lowest point of the hip and working.up, press tape into
place keeping tape centered over the hip. Apply moderate pressure
onto the surface of the tape to ensure a secure bond between the panel
and the tape.
i
1 Cut ridge tape as required for ventilation prior to installing ridge vent.
Step 6.
ape over toe board nail holes once the toe boards are removed, working
from the highest toe boards to the lowest.
I
i
I
I
i
i
i
%61
Roof Covering Installation Instructions
ZIP System Roof & Wall sheathing is a code recognized sheathing and underlayment and is approved for use with the following roof covering'
- Asphalt -fiberglass Shingles
- Metal Roofs (shingles and panels)
- Clay Tile j
Concrete Tile
Slate and Slate -type Shingles
Wood Shingles
Wood Shakes
When installing roof coverings, follow applicable codes and manufacturer's suggested instructions. Some roof coverings require a slip -she in addition to
conventional underlayment. Where slip -sheets are required, they should be installed over ZIP System sheathing panels.
Note: Visit zipsystem.com for updates and installation details.
Asphalt -fiberglass Shingles T
Apply asphalt shingles directly to ZIP System sheathing. For roofs with a slope of 2/12 or greater but less than 4/12, additional underlayment ma
{ybe required.
Install asphalt -fiberglass shingles according to applicable codes and manufacturer's installation instructions. I
Metal Roof Coverings ?
Metal roof coverings may be applied to ZIP System sheathing provided that the roof covering manufacturer's installation instructions and applicable
codes are followed. I;I
Fasteners used to secure the ZIP System Roof & Wall sheathing panels to supporting framing must be compatible with the specific meta � roof covering
used. Galvanized fasteners shall be used with galvanized roof coverings, aluminum -zinc coated fasteners shall be used with aluminum-zi lc coated roof
coverings and 300 series stainless steel fasteners shall be used with copper roofs. Stainless steel fasteners are acceptable with all metal roof ; ypes.
In addition, metal roof flashing shall also be made of a material compatible with the specific metal roof covering used. Apply metal shingles on roofs with
slopes of 3/12 or greater.
Clay and Concrete Tile Roof Coverings
ZIP System Roof & Wall sheathing is intended to replace the first layer in a two -layer or multi -layer underlayment system. When installing clay or
concrete tile roof coverings, follow the installation recommendations of FRSAJTRI 07320. Install tile roofs according to applicable codes and 71 manufacturers
ihstallation instructions.
Slate and Slate -type Shingles
Apply slate and slate -type shingles on roofs with slopes of 4/12 or greater. Install slate and slate -type shingles according to applicable codes and
installation instructions.
Wood Shingles
ZIP System Roof & Wall sheathing is intended to replace the first layer of underlayment required by the IBC and/or the IRC. Additional layers of$nderlayment
may be required by code depending on the local climate. Apply wood shingles on roofs with slopes of 3/12 or greater. Install wood shingle according to
applicable codes and manufacturer's installation instructions.
Wood Shakes
ZIP System Roof & Wall sheathing is intended to replace the first layer of underlayment required by the IBC and/or the IRC. Additional layers of
may be required by code depending on the local climate. ZIP System roof sheathing is not to be construed as a replacement for interlaymen
shakes on roofs with slopes of 4/12 or greater. Install wood shakes according to applicable codes and manufacturer's installation instructions.
Apply wood
ZIP System® Roof & Wall Sheathing Installation Manual
Q
,ZIP System® Sheathing Installation on Walls
Overview: ZIP System Roof & Wall sheathing is composed of ZIP System panels and ZIP System seam sealing tape. ZIP System® Roof &>IVall Sheathing
panels should be fully installed before the seam sealing tape is applied. The following installation steps are presented as a general outline of he installation
process. These are manufacturer installation recommendations —please visit zipsystem.com for a library of flashing and installation details. You are fully and
solely responsible for all safety requirements. Good construction and safety practices should be followed at all times. ail(
Step 1. Install ZIP System Roof & Wall sheathing panels positioned
with the water -resistive barrier facing outside. The panels may
be installed with the long side of the panel oriented either
horizontally or vertically to the framing members. Walls that are
designed to resist lateral shear forces and sheathed with wood
structural panels typically require solid framing or blocking behind
all panel edges. If oriented horizontally, block horizontal joints if
wall is designed for bracing or as a shear wall.
1/8" spacing between square edges of all adjacent panels is
recommended in accordance with industry standards for woad
sheathing installation.
/ 8' and 4'
8' Panel Edges Panel Edges 4' Panel
1/8" 1/8°
Edges
%8°
II II
ui
space
The unique edge profile is Maintain 1/8" space where Maintain 1/q"
designed to accommodate 8' panel edges meet 4' where 4' edges
meet.
incremental panel panel edges. Unique edge Unique edg
,profile is on
expansion and does not profile does not provide 8' edges o
I' .'
require manual gapping the full 1/8" recommended
along the 8' edges.' space in this situation."
Step 2. Fasten the panels to the framing members with code approved
fasteners. Space fasteners 6" o.c. along supported edges and 12"
o.c. at intermediate supports, unless otherwise, specified by local
code or the designer of record. It is the responsibility of the general
contractor to verify proper. fastener type and spacing prior to
installation. Apply the fasteners 3/8" from the ends and corners.
An ideal installation would be where fastener heads are flush with
the panel surface. However, due to variations in materials and
limitations on equipment, this may be difficult to achieve in some
situations. It is not required to tape over overdriven fasteners
unless the fastener head creates a hole through the entire panel
thickness. Please see the technical tip "Overdriven Fasteners in
Zip System Roof and Wall Sheathing," on zipsystem.com for
more information.
V
7
Di
ZIP System'" Tape Installation - Wall Panel Seams
Apply ZIP System tape after all ZIP System Roof & Wall sheathing panels are fully fastened to wall -framing members. Only ZIP System tape slhould
to seal the seams of ZIP System panels. Ensure that the panel surface is dry and free of sawdust and dirt prior to taping. ZIP System tape
be used
Is a contact
tape that requires pressure for an adequate seal. YI
I
I �
Step 1. Tape all seams using ZIP System tape. Ensure that the tape
i
is centered over the seam within +/- 1/2" to provide adequate
coverage and that wrinkles in tape are minimal.
Use the ZIP System tape gun or roller to apply pressure to the tape
�.
and smooth out any wrinkles.
I
Step 2. Wherever tape splices occur at a horizontal or vertical seam, create
f
4 'I
an overlapping splice of at least 3".I�
d
i
At T-joints, the tape pieces should overlap by at least 1 ". Apply
moderate pressure onto the surface of the tape to ensure a secure
bond between the panel and the tape.
Use the ZIP System tape gun or roller to apply pressure to the tape
and smooth out any wrinkles.��
i
Take special care to remove any voids and/or trapped air at splice
areas and T-joints.
Step 3. Tape inside and outside corner seams.
I
�s t gad
A
Inside comer seam
Outside comer seam
I
III
Note: Tape over any areas of the panel or tape that are damaged during construction.
I
0
i
I
i
I�
ZIP System® Roof & Wall Sheathing Installation Manual
i
SIP System -Window Installation DISCLAIMER: The following steps represent a general overview for the proper installation of window flashing. Ple
Y the installation instructions of your window manufacturer as well as code requirements in your jurisdiction for full
Flanged Windows
1. Fasten the ZIP System sheathing
i
to the wood frame and install
ZIP System tape to all wall panel
seams, as detailed in sections
02 and 03.
<eR
2. ZIP System tape may be used as pan flashing if
installed in accordance with flanged window
installation details posted on zipsystem.com.."'a
Other adhesive -based flashing tapes (must meet
ICC-ES Acceptance Criteria for Flashing Materials
(AC148)) may be used as pan flashing if installed
per ASTM 2112-07. Apply the flashing to cover
the bottom of the opening, overhanging onto the
sheathing by at least 2" and extending a minimum
of 6" up each jamb.
Apply sealant around inside face of mounting
flange. Sealant must be gapped at the sill
to permit drainage. Install and level window per
manufacturers installation instructions. Verify
sealant compatibility with window manufacturer.
When using ZIP System tape as pan flashing,`
butyl, 100% silicone or polyurethane sealants
are acceptable. Do not use latex or other water- '14� ' .
based sealants.
4. Cut two pieces of ZIP System tape or another
adhesive -backed flashing tape (must meet ICC-
ES Acceptance Criteria for Flashing Materials
(AC148)) and apply to each of the window jamb
flanges, ensuring the jamb flashings overlap the
sill flashing.
Once the tape is in place, use the tape gun or roller
to seal the flashing to the sheathing.
5. Cut a length of ZIP System tape or another
adhesive -backed flashing tape (must meet ICC-
ES Acceptance Criteria for Flashing Materials
(AC148)) and apply to the header, ensuring that
the flashing overlaps the jamb flashings.'
Once the tape is in place, use the tape gun or roller
to seal the flashing to the sheathing.
'DO NOT tape bottom flange.
6. From the interior, apply low-pressure polyurethane
foam (for windows) between the rough opening
and the window frame. (Caulk sealant compatible
with the sill flashing may be used at the sill if the IJ
opening between the sill flashing and window
is too narrow to allow the use of low-pressure
polyurethane foam.)
When using ZIP System tape, butyl, 100%
silicone or polyurethane sealants are acceptable.
Do not use latex sealants with ZIP System tape. If
using another flashing tape, follow the flashing
manufacturer's recommendation in selecting a
sealant compatible with that flashing.
i
Brick Mould Windows
1. Fasten the ZIP System sheathing
to the wood frame and install
ZIP System tape to all wall panel
seams, as detailed in sections
02 and 03.
2. If recommended by the window
manufacturer, cut a strip of wood
to function as a back dam at the
sill. The wood strip should have
a length equal to the width of the
rough opening and a height and
width of at least 1/2". Position the
block at the inside edge of the
window frame.
defer to/consult
09
ZIPS stem -Window Installation DISCLAIMER: The following steps represent a general overview for the proper installation ofwindowflashing. Plepedefer to/consult
Y the installation instructions, of your window manufacturer as well as code requirements in your jurisdiction for full) nstallation details.
i"
Brick Mould Windows (continued)
3. ZIP System tape may be used as pan flashing if
installed in accordance with brick mould window
installation details posted on zipsystem.com.
Other adhesive -based flashing tapes (must meet
[CC -ES Acceptance Criteria for Flashing Materials
(AC148)) may be used as pan flashing if installed
per ASTM 2112-07. Apply the flashing to cover
the bottom of the opening, overhanging onto the
sheathing by at least 2" and extending a minimum
of 6" up each jamb.
4. For vertical jambs, cut ZIP System tape or another
adhesive -backed flashing tape (must meet ICC-
ES Acceptance Criteria for Flashing Materials
(AC148)) and apply to each of the window jambs.
Ensure that they cover the entire inside of the rough
s
opening as well as overlap onto the sheathing by
at least 2". Flashing shall also extend above the
rough opening, such that it will project 1" beyond
the exterior trim of the window.
Once the tape is in place, use the tape gun or roller
to seal the flashing to the sheathing.
5. Apply sealant to jambs and header allowing for
drainage at the sill in accordance with window
manufacturer's installation instructions. When3M
using ZIP System tape, use a butyl, polyurethane
or 100% silicone sealant. Do not use latex or
other water -based sealants with ZIP System
tape. When using another flashing tape, follow the
flashing manufac-turer's recommendations in
selecting a sealant compatible with that flashing.
6. Install and level window per manufacturer's
installation instructions.
7. Cut a piece of rigid head flashing so that when
installed, it is flush with the edges of the exterior
moulding of the window. Apply a bead of sealant
to the back and bottom surface of the rigid
head flashing. Use sealant recommended by the
flashing manufacturer.
8. Secure the rigid head flashing to ZIP System
wall sheathing.
9. Cut a length of ZIP System tape or another
adhesive -backed flashing tape (must meet ICC-ES
Acceptance Criteria for Flashing Materials (AC148))
and apply to the rigid head flashing, ensuring
that the adhesive -backed flashing overlaps the
jamb flashings.
Once the tape is in place, use the tape gun or roller
to seal the flashing to the sheathing.
10. From the interior, apply low-pressure polyurethane
foam (for windows) between the rough opening and
the window frame. (Caulk sealant compatible with
the sill flashing may be used at the sill if the opening
between the sill flashing and window is too narrow
to allow the use of low-pressure polyurethane foam.)
When using ZIP System tape, butyl, 100% silicone.
or polyurethane sealants are acceptable. Do not
use latex or other water -based sealants with ZIP
System tape. If using another flashing tape, follow
the flashing manufacturer's recommendation in
selecting a sealant compatible with that flashing.
ZIP System® Roof & Wall Sheathing Installation Manual
10
ZIP System -Penetration Open i ngS DISCLAIMER: The following steps represent a general overview for the proper installation of penetration flashing. Pie
your code requirements in your jurisdiction for full installation details.
WALL ASSEMBLY
ZIP SYSTEMS WALL SHEATHING
WOOD OR LT. GA, METAL STUDS /
118-INCH GAP RECOMMENDED AT
PANEL EDGES UNLESS
OTHERWISE PROW DED BY
OVER ALL JOINTS IN ZW SYSTEMS
OVERLAP TAPE A MINIMUM OF
14NCHATALLT401KS
INSTALL ZIP SYSTEM& TAPE AT ALL
INTERIORCCR ERS
FASTEN ZIP SYSTEM& WALL
SHEATHING AS REQUIRED BY
DESIGNER-0E-RECORD OR LOCAL
BUILDING CODE
WALLASSEMBLY
ZIP SYSTEMS WALL SHEATHING
WOOD OR LT. GA. METAL STUDS
118-INCH GAP RECOMMENDED AT
PANEL EDGES UNLESS
OTHERWISE PROVIDED BY
MACHINED PROFILED EDGES —
INSTALL ZIP SYSTEMS TAPE OR
ADHESIVE BACKED FLASHING (MUST
MEET AC148) IN SEQUENCE FROM
BOTTOM, SIDES, THEN TOP TO
ENSURE SHINGLE LAP OF ADHESIVE
BACKED FLASHING
ZIP SYSTEMS TAPE (INSTALLED
OVER ALL JOINTS IN ZIP SYSTEMS
WALL SHEATHING).
OVERLAP TAPE A MINIMUM OF
1-INCH AT ALL TJOINTS —
USE FLANGED ELECTRICAL
BOXES OR MEMBRANE FLASHING
TO PROVIDE FLANGES FOR
ELECTRICAL BOXES
WALL ASSEMBLY
LP SYSTEM& WALL SHEATHING
WOOD OR LT. GA, METAL STUDS
UB.NCH GAP RECOMMENDED AT
PANEL EDGES UNLESS
OTHERWISE PROMOED BY
MACHINED PROFILED EDGES -
MP SYSTEMS TAPE RNSTALLED
OVER ALL JOINTS IN LP SYSTEMS
WALL SHEATHING'
OVERLAP TAPE MINIMUMOF
1-INCH ATALL TJOINTS -
INSTALLZ1 SYSTEMSTAPEATALL
EXTERIOR CORNERS
FASTEN ZIP SYSTEMS WALL
SHEATHING AS REQUIRED BY
DESIGNER-OFRECORO OR LOCAL
BUILDING CODE
WALLASSEMBLY
ZIP SYSTEM® WALL SHEATHING
WOOD OR LT. GA. METAL STUDS
118-INCH GAP RECOMMENDED AT
PANEL EDGES UNLESS
OTHERWISE PROVIDED BY
MACHINED PROFILED EDGES —
INSTALL ZIP SYSTEMS TAPE OR
ADHESIVE BACKED FLASHING (MUST
MEET AC148) IN SEQUENCE FROM
BOTTOM, SIDES, THEN TOP TO
ENSURE SHINGLE LAP OF ADHESIVE
BACKED FLASHING
ZIP SYSTEMS TAPE (INSTALLED
OVER ALL JOINTS IN ZIP SYSTEMS
WALL SHEATHING).
OVERLAP TAPE A MINIMUM OF
1-INCH AT ALL TJOINTS —
USE FLANGED VENT HOODS
;e deter to/consult
11
ZIP System Sheathing Installation Details on Walls — visit zipsystem.com for more
WALL ASSEMBLY
VINYL/WOOD/FIBER CEMENT SIDING
(INSTALLED IN ACCORDANCE WITH
CLADDING MANUFACTURER'S
INSTALLATION RECOMMENDATIONS)
ZIP SYSTEM® WALL SHEATHING
WOOD OR LT. GA. METAL STUDS
TOP EDGE OF FLASHING TAPED TO
WALL SHEATHING WITH ZIP SYSTEM®
TAPE OR ADHESIVE BACKED
FLASHING. (MUST MEET AC148)-
CODE APPROVED FLASHING `
I FOUNDATION
WALL ASSEMBLY
VINYUWOOD/FIBER CEMENT SIDING
(INSTALLED IN ACCORDANCE WITH
CLADDING MANUFACTURERS
INSTALLATION RECOMMENDATIONS)
ZIPSYWOOD RLT. GAMETAL THIN
STUD
WOOD OR LT. GA. METAL STUDS
1/8-INCH GAP RECOMMENDED AT
PANEL EDGES UNLESS
OTHERWISE PROVIDED BY
MACHINED PROFILED EDGES -
ZIP SYSTEMO TAPE (INSTALLED
OVER ALL JOINTS IN ZIP SYSTEM®
WALL SHEATHING).
OVERLAP TAPE MINIMUM OF
1-INCH AT ALL TJOINTS
1184NCH GAP RECOMMENCED AT
PANEL EDGES UNLESS
OTHERWISE PROVIDED BY
MACHINED PROFILED EDGES -
FASTEN ZIP SYSTEM® WALL
SHEATHING AS REQUIRED BY
DESIGNER -OF -RECORD OR LOCAL
BUILDING CODE
WALL ASSEMBLY
BRICK VENEER
AIR SPACE (AS PRESCRIBED BY
LOCAL BUILDING CODE)
ZIP SYSTEM® WALL SHEATHING
WOOD OR LT. GA. METAL STUDS
TOP EDGE OF FLASHING TAPED
WITH ZIP SYSTEM® TAPE OR
ADHESIVE BACKED FLASHING.
(MUST MEET AC148)
CODE APPROVED BASE
FLASHING
WEEP HOLES (AS PRESCRIBED
BY LOCAL BUILDING CODE) -
WALLASSEMBLY
BRICK VENEER
AIR SPACE (AS PRESCRIBED BY
LOCAL BUILDING CODE)
ZIP SYSTEMiD WALL SHEATHING
WOOD OR LT. GA. METAL STUD)
1/8-INCH GAP RECOMMENDED AT
PAN EL EDGES UNLESS
OTHERWISE PROVIDED BY
MACHINED PROFILED EDGES -
ZIP SYSTEMO TAPE (INSTALLED
OVER ALL JOINTS IN ZIP SYSTEMD
WALL SHEATHING).
OVERLAP TAPE MINIMUM OF
1-INCH AT ALL T-JOINTS
118-INCH GAP RECOMMENDED AT
PANEL EDGES UNLESS
OTHERWISE PROVIDED BY
MACHINED PROFILED EDGES -
FASTEN ZIP SYSTEMO WALL
SHEATHING AS REQUIRED BY
DESIGNER -OF -RECORD OR LOCAL
BUILDING CODE
Note: For optimal air leakage reduction, all untaped edges of the panels can be caulked, gasketed or sealed with a weather stripping
,ZIP System® Roof & Wall Sheathing Installation Manual
�12
ZIP System Sheathing Installation Details on Walls (continued)
WALL ASSEMBLY
BRICK VENEER
AIR SPACE (AS PRESCRIBED BY
LOCAL BUILDING CODE)
ZIP SYSTEM@ WALL SHEATHING
WOOD OR LT. GA. METAL STUDS
TOP EDGE OF FLASHING TAPED
WITH ZIP SYSTEM@ TAPE OR
ADHESIVE BACKED FLASHING.
(MUST MEET AC148)
CODE APPROVED FLASHING
WEEPS (AS PRESCRIBED BY
LOCAL BUILDING CODE) —
STEEL LINTEL
INSTALL WINDOW IN
ACCORDANCE WITH DETAILS
24A-24D OR 25A-25D
WALL BEYOND
WALL ASSEMBLY
CODE APPRO
(INSTALLED It
CLADDING Mf
INSTALLATIOP
EXTERIOR RI(
DRAINAGE PL
ZIP SYSTEM®
WOOD OR LT.
TOP EDGE OF
WALL SHEATI
TAPE OR ADH
FLASHING. (h
CODE APPROVED FLASHING
FOUNDATION
WALL BEYOND
BACKDAM PER WINDOW
MANUFACTURER'S INSTALLATION
RECOMMENDATIONS
INSTALL CODE -RECOGNIZED
�I
SILL/PAN FLASHING IN ROUGH
I
OPENING PRIOR TO WINDOW
INSTALLATION.
I'
TOP EDGE OF FLASHING TAPED
WITH ZIP SYSTEM® TAPE OR
ADHESIVE BACKED FLASHING.
"
(MUST MEET AC148)
WEEPS (AS PRESCRIBED BY
LOCAL BUILDING CODE)
)
CODE APPROVED FLASHING
I
i
WALL ASSEMBLY
BRICK VENEER
AIR SPACE (AS PRESCRIBED BY
LOCAL BUILDING CODE)
ZIP SYSTEM@ WALL SHEATHING
WOOD OR LT. GA. METAL STUDS
Note: For optimal air leakage reduction, all untaped edges of the panels can be caulked, gasketed or sealed with a weather stripping