HomeMy WebLinkAboutEXISTING POOL RECCESED GUTTER:4.
MANNED
BY
Z-ft LudeConty EXISTING 6" RAISED
"BISCAYNE" COPING I�
411 (W/ TILE OVER) TO BE
21' REMOVED
2rr T I
6.5" \ 6"
WATER LINE
EXISTING 2" X 4"
GUTTER & ALL TILE
IN GUTTER TO BE
REMOVED TO POOL
SHELL - REMOVE
EXIST. GUTTER
GRATE
EXIST. PAVER
DECK TO REMAIN
EXIST. POOL SHELL
t-ILE COPY
Existing Pool Recessed Gutter
SCALE: 3/4" = F-0"
NEW GLAZED TILE
AT BACK OF GUTTER FROM
BO'I'TO, Q OF COPING TO _
BOTTOM OF GUTTER -,,
4"
WATER LINE
4"
INSTALL NEW 1/4" DIA. S.S.
ALL-TH AD DOWELED 3" INTO
EXIST P ,i OL BEAM W/ SIMPSON
"SET" E1 OXY @ 12" O.C. & (2) 1/4"
DIA. S.S.I'JALL-THREAD CONT. - USE
STO FL WABLE CONCRETE TO
FORM + W GUTTER LIP (CLEAN
AND ETCH EXIST. BEAM PRIOR TO
PLACE �', ENT OF CONCRETE)
INSTAL NEW 2" X 6"
SLIP-","SISTANT CAP TILE ON TOP,
OF LIP AND 6" X 6" TILE BELOW
4"
2" 12"
�� �E --
A '
R
CODE COMPLIANCE
ST. L UCIE COUNTY
BOCC
NEW BULL -NOSE BRICK
COPING ON TOP OF f
NEW CONCRETE BEAM f
(DOUBLE BRICK COPING)
5"
EX. SLOPE
EXIST. PAVER
DECK TO REMAIN
NEW TILE AT BACK
RAISED BEAM TO DECK
EXIST. POOL SHELL
NEW 4" X 12" - 3000 PSI CONCRETE BEAM
W/ (2) ROWS OF 6" LONG - #3 DIA. REBAR
DOWELED 3" INTO TOP OF EXIST POOL
BEAM W/ SIMPSON "SET" EPDXY @ 12" O.C.
(STAGGERED 6") & (2) #3 DIA. REBAR CONT.
Proposed Pool Recessed Gutter
SCALE: 3/4" = V-0"
STATE OPERATING PERMIT NO.56-60-00104
DRAWN BY: WJ, DATE: 4-24-19 SCALE: N.T.S. JOB NO.: 19-281
RENOVATIO DETAIL FOR:
Islandia Condo
SOUTI POOL
9500 S. OCEAN AN DRIVE
JENSEN 1�IEACH, FL
CURTIS - SINCLAIR. INC.
8259 N. MILITARY TRAIL, SUITE 3
PALM BEACH GARDENS, FL 33418
PH. 561-630-8534 FAX 561-630-8557
C.O.A. NO.5725
00®St I t I 1 1 1914 e4.4
B
mo•,��� �, c•E 1v s� •. ��'-
m
m moo. No 35631
e o
STATE OF '•W
�0.
Stephen M. Sinclair, P.E.
Florida License No. 35631