HomeMy WebLinkAboutLETTER ROOF SPECIFICATIONJ F1 rchi#¢ctanic Inc y 12, 2018 GGANNED By nt Lucie County Building Department R. LUCIS COUP tn: Roof Permit Plan Review 00 Virginia Avenue Pierce, FL.34982 Re: nufacturer: files: RECEIVED JUL 16 Z018 ST. I.urrie Caynty, Permitting Roofing specification prepared for the St. Lucie County Building Dept. for the stfucture located at 405 Gregory Street., Saint Lucie County, Florida 1�ind Speed: Eiposure: P,MPan Roof Height: tch: Required Design Pressure: aximum Uplift Pressure: Fasteners: derlayment: of Decking: Extreme Metal Fabricators, LLC, 26 Ga. 1" Nail Strip, FL. #17022.5 FBC 2017; Section R 905.10 165 MPH; Ultimate Design Wind Speeds C 30' Maximum 5/12 Zonel: 30.93 Zone 2: -51.55 Zone3:-.77.32 -86 #10 x 1" @ 6" o.c„ (or of sufficient length to meet 3/16" min, penetration through deck or 5/8" min. embedment into wood plank) Polyglass Roof Underlayments, FL 5259-R28 (self -adhering) Existingk5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2, and 4" O.C. thru out zone 3. above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, the Manufacturer's recommendations. ie ctfP llftitf� d, Seal Deiaware Avenue Tel: 772 460 7751 www.architectonicinc.com Pierce; Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1