Loading...
HomeMy WebLinkAboutPRODUCT APPROVALAll SCANNED BY Business & Professional Regulation St,1Lude Cow rrc •I SCIS Home I Log in . I User Registration '" Mot Topics I SubmlYSurcharge Stets &Facts Publlcatlons I F8C Staff I BCIS Site Map Unks I Search j bpr a Product Approval USER: Publlc User i �rr RECEIVED IIIProduct Aooroval Menu > �Qr duct or Aoollratlon Search > Aoolicatlan UR > Applioetion Detail FL # FL5259-R28 J U L 16 2018 Application Type Revision Code Version 2017 ST, Lucie County, Permitting Application Status Approved Comments ' Archived ❑ Product Manufacturer POLYGLASS USA" . 'Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1378- Ext 242 alender@polyglass.com Authorized Signature Arel Lender alender@polyglass.com Technical Representative Maury Alpert Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (912)429-8610 MAlpert@polyglass.comm Quality Assurance Representative Apel Lender Address/Phone/Email 1111 W. Newport.Center Drive Deerfield. Beach, FL 33442 . (954) 233-1230 ALender@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer , ❑ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/05/2018 _ . Validated By John W. Knezevich, PE 0 Validation Checklist - Hardcopy Received certiflcate of Independence FI 5259 R28 COI 2018 01 COI NIEMINEN odf Referenced Standard and Year (of Standardj Standard Year ASTM D1970' 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6164 2011 VI ASTM D6222 2011 FM 4474 2011 FRSA/TRI April 2012 2012 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 01/24/2018 Date Validated 01/29/2018 Date Pending FBC Approval 01/30/2018 Date Approved 04/10/2018 Summary of Products FL # Model, Number or Name Description 5259.1 i lyglassFRoof, - jrWerj4y - do ' g nde aymer is Limits of Use Installation Instructions Approved for use in HVHZ: No FL5259 R28 11 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- R28.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nleminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other:. 1.) The design pressure In this Evaluation Reports application relates to one particular FL5259 R28 AE 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- R28.odP underlayment system (over concrete deck) for use under foam -on tile systems (where Created by Independent Third Party: Yes the underlayment forms part of the load - path). Refer to ER Section 5.6.4 for other systems, other deck types and associated maximum design pressures. 2.) Refer to ER Section 5 for other limits of use: Back Next Contact Us:; 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Coovriaht 2 07-2013 State of Florida.:: Privacy Statement ;: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mall address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emaiis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click e e . Product Approval Accepts: Credit Card Safe (954) i SCOPE: This E for use describi herein. Quality produ distribute This Evalt Preparedly NEMp etc. Certii lcate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 EVALUATE TEST CONSULT CERTIFY ION REPORT USA, Inc. t Newport Center Drive Beach, FL 33442 Evaluation Report P12060.02.09=111124 FL5259-R28 Date of Issuance: 02/24/2009 Revision 24:.01/24/2018 ation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use. of m materials in the State of Florida. The. documentation submitted has been reviewed by RobertNieminen, .E. the product under the Florida Building Code and. Florida Building Code, Residential Volume. The products herein have been. evaluated for compliance with the 6u' Edition (2017) Florida Building Code sections noted N:�Po'.,glass• ,gnfilJnde-ftyme11TS1 6 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. i COMPLIANCE: This- Evaluation Report- is valid until such time as the named product(s) changes, the referenced surance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this i Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this 1 Report relative to updated Code requirements with each Code cycle. RENT: The Evaluation Report number preceded by the. words "NEMOIetc. Evaluated' may be 'displayed in literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. Upon request, a copy of this entire. Evaluation Report shall be provided to the user by the manufacturer or its sand shall be available for inspection at the job site at the request of the Building Official. ation Report consists Of pages 1 through 14. RobertJ.1l. Nieminen, P.E.. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal, appearing was authorized by Robert Nleminen, P.E. on 01/24/2018. This does not serveas an electronically signed document. CERTIFICATI& OF INDEPENDENCE: 1. NEMO�i �etc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distrib-III tin, products it evaluates. 2. NEMO etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Roberhl ieminen, P.E. does not have nor will acquire, a financial interest in any company_ manufacturing or distributing products for which he evaluation reports are being issued. 4. Robert�lf ieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the . produa. s. This is building code evaluation. Neither NEMO Ietc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project lion which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifi(,:ally for that purpose. r 1. 2. 3. EVALUATION: NNEMO etc. Category: Roofing agory: Underlayment nce Statement: Roof Underlayrnents, as produced by Polyglass USA, Inc., have. demonstrated compliance with the sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. nce is subject to the Installation Requirements and, Limitations / Conditions of Use set forth herein. IYYAlfYJ: ' Lion Pro a Standard _ Year 1.3.1 Wind Uplift FM 4474 2011 t.3.1 Wind Uplift UL 1897 2012 7.2.3 / 1507.1.1 Physical Properties ASTM D226 2009 7.2.4 / 1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 7.3.3 Physical Properties FRSA/T.RI April 2012 2012 7.11.2 - Physical Properties ASTM D6164 2011 ?.11.2 Physical Properties ASTM D6222 2012 110 Accelerated Weathering ASTM D4798 2011 Approvals (TST 1867) (TST 5878) (TST 5878) (TST 5878) (TST 5878) (TST 5878) (TST 5878) (TST 5878) (TST 5878) (TST 5878) (TST 5878) (TST 5878) (TST 5878) (TST 5878) (TST 5878) 1(TST 2508) I(TST _2508) )(TST 6049) )(TST 6049) ) (TST 6049) )(TST 6049) ) (TST 6049) )(TST 6049) ) (TST 6049) (TST 6049) (TST 6049) )(TST 6049) (TST 6049) (TST 6049) . (TST 6049) (TST 6049) (TST 6049) (TST 6049) NEMO &C LLC. CertfficatAafAutharizanan #32455 Examination Wind Uplift . Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Wind Uplift Wind Uplift Physical Properties Wind Uplift Physical Properties Wind Uplift Physical Properties Wind Uplift Physical Properties Wind Uplift Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Reference 3004091 . PRI61111 PUSA-005-02-01 PUSA-013-02-01 PUSA-013-02-02 PUSA-013-02-03 PUSA-018-02-01 PUSA-028-02-01 PUSA-033-02-01 PUSA-035-02-01 PUSA-055-02-02 PUSA-061-02-02 PUSA-076-02-01 PUSA-083-02-01 PUSA-088-02-01 JX20H7A RX14EBA 11752.09.99-1 11757.08.01-1 11776.06.02 02200.07.03 P1740.01.07 P5110.04.07-1 P9260.03.08 P13450.08.09 P30540.11.09-R1 P11030.11.09-1- P11030.11.09-2 P11030.11.09-3 P33360.06:10 .P33370.03,11 P33370.04.11 P37300.10.11 e EDITION (2017) FBC NON-HVHZ EVALUATION Polyglass Roof Underlayments; (954) 233-1230 Date 01/12/2000 04/08/2002 01/31/2002 12/23/2002 12/23/2002 12/23/2002 07/14/2003 07/13/2005 01/12/2006 09/29/2006 12/10/2007 01/28/2008 02/22/2008 04/14/2008 07/29/2009 04/01/2008 01/29/2009 02/08/2000 08/13/2001 61/16/2003 07/14/2003 01/04/2007 04/11/2007 03/21/2008 08/13/2009 11/30/2009 11/30/2009• 11/30/2009 11/30/2009 06/25/2010 03/02/2011 04/26/2011 10/19/2011 Evaluation Report P12060.02.09-1124 ' FL5259-RZB Revision 24: 01/24/2018 Page 2 of 14 (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) (TST 6049) :S (EVL 2396) ni-Dade (CER 1592) -lass USA ;lass USA ;lass USA I.C. (QUA9625) 4. PRODUCT DESCRIPTION: Examination Physical Properties Physical Properties Physical Properties Wind Uplift Physical Properties Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Wind Uplift Physical Properties Wind Uplift Physical Properties Physical -Properties Physical Properties IBC Compliance HVHZ Compliance Manufacturing Affidavit P/L Affidavit Materials Affidavit Quality Control Reference P40390.08.12-1 P40390.08.12-2 C41420.09.12-3 . . P39680.03.13 P45370.04.13 P1738.02.07-112 11757.04.01-1-R1 P41630.08.13 P11751.05.03-R1 P11781.11.03-R1 P45270.05.14 6020.07.14-1 6020.09.14-2 6020.09.14-3 6020.09.14-4 6020.09.14-5 6020.09.14-6 P46520.10.14 P43290.10.14 PLYG-SC7550.03.15 P40390.04.15 P44360.10:14-R1 PLYG-SC8080.05.15=1 PLYG-SC8905.05.16-1 PLYG-SC8080.07.16 PLYG-SC12025.10.16 PLYG-SC13040.12.16 PLYG-SC11900.03.17 PLYG-SC12115.08.17 ESR-1697 NOA 14-0717.08 Products Current Mule -Hide Cross Ltg Polystick SA Compound Service Confirmation 4.14 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1�2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.11j3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet. 11 4.44 Polyglass APP Base is a fiberglass=reinforced, APP modified bitumen base sheet. ONEMO I etc. Date 08/06/2012 08/07/2012 09/11/2012 03/04/2013 04/26/2013 04/29/2013 04/30/2013 08/06/2013 11/26/2013 11/26/2013 05/12/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 09/08/2014 1.0/03/2014 10/17/2014 03/24/2025 04/03/2015 05/18/2015 05/20/2015 05/17/2016 07/16/2016 10/22/2016 12/27/2016 03/10/2017 08/08/2017 11/01/2014 01/22/2015 02/18/2009 03/01/2008 08/18/2011 Exp.10/05/2018 P8lystiIE IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. Polystick TU Plus Is a nominal 80-mil thick rubberizedasphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC, I.I.C. Evaluation Report P32060.02.09-R24 Certykate l Authadzation #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass_ Roof Underlayrnentsl (954) 233-1230 Revision 24: 01/24/2018 Page 3 of 14 5. fONEMOjetc. .4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface, meets FRSA/TRI April 2012. .5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. .6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester ireinforced,.APP modified bitumen cap sheets; meet FRSA/TRI April 2012. 2.7 Polystick Dual PrW" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970. 8 Polystick Tile Pro' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 2 9 Polystick - MU-X is a nominal 54-mil thick dual -layer rubberized asphalt. waterproofing . membrane, fiberglass reinforced, with a polypropylene'film surface; meets AC188 and. physical requirements of ASTM D1970 (See Section 'I 5.8). 3� 1 Elastoflex G. TU is a polyester reinforced, modified bitumen the underlayment composed of a. sand -surfaced SBS modified bitumen back -side and granule -surfaced APP modified bitumen top -side. -Elastoflex G TU Is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. 3�12 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; -meet ASTM D6164. Elastoflex S6 G and. Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System". from FRSA/TRI April'2012 (04-12) beneath mechanically fastened tile roof systems. Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the 'Two Ply System" from FRSA/TR! April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System":from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems. , 13 - Polyflex G and Polyflex -G FR-are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 203-2 (04-12) beneath mechanically fastened or adhered the roof systems. Polyflex G FR is for use as an alternate to Heat Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 5.2'1 5.31 5.4 This ls' a building. code evaluation. Neither NEW I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. This Evaluation Report is not for'use in the HVHZ. Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval. documents. If .not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with'supporting data for the prepared roof covering. NEW ET�7, LLC. 1x Certitate ofAutharizatlan A324SS 6 EDITION 12017) FBC NON-HVHZ EVALUATION Polyglass Roof Underlayments; (954) 233-1230 Evaluation Report P12060.02.09-R24 FL5259-R28 Revision 24: 01/24/2018 Page 4 of 24 ONEMO I etc. Allowable Roof Covers: ri'i;, `` r .. r , ✓ - ` TAB�Ft OOFCOYEQ Q ONS aau a �, Un�derlayment Asphalt Shingles Nall -On The Foam -On 711e Metal Wood Shakes &Shingles Slate Elastobase 'I YeS Yes (Base Sheet in 2-ply system) Yes. (Base Sheet In 2-ply system) Yes Yes Yes Eliistobase P Ye5 es (Base SheetYn 2-ply system) es n 2-phj system) (Base Sheet in Yes Yes Yes PoI l yglass G2 Base No (Base Sheet Yn 2-ply system) (Base Sheet In 2-ply system) No No No Polass APP Base l�g Ili No Yes (Base Sheet In 2-ply system) Yes (Base Sheet In 2-ply system) No No No Polystick NITS or MTS PLUS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Po:Iystick TU P No Yes Yes (See 5.5.1) No No No Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes PolystickTUMax No Yes Yes (See 5.5.1) Yes No No Po jstick Dual Pro Yes No No Yes Yes Yes Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex S6 G Yes. Yes Yes (See 5.5.1) No Yes Yes Ela4oflex S6 G FR Yes Yes No No Yes Yes Ela toflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G Yes. Yes Yes (See 5.5.1) No Yes Yes PololexGFR Yes Yes No No Yes Yes PolyflexSAPorSAP FR Yes Yes Yes (See5.5.1) No Yes Yes Mu ie-Hide SA-APP Cap Sheet or A-APP Cap Sheet (FR) Yes Yes Yes (See 5.5.1) No Yes Yes �I 5.5,',1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. s _. `TABLEIZA 4 „i411 ONIABLE �ILE /�DHESII/EIMUNAER0YME117T CO BINA710N5 ; r, `. - i Adhesive Florida Product Underlayments Approval DAPI Foam Touch'n Seal StormBond Roof Tile�Adhesive FL14506 Polystick TU Plus, Polystick TU Max Doll TileBondTM FL22525 Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro ICP it dhesives Polyset® AH-160 FL6332 Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, II II Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) II Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, lCP dhesives Polyset® RTA-1 FL6276 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, I I Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, U.C. Evaluation Report P12060.02.09-R24 Ceri lcate!6f Autharlmtlan #32455 6t" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZB Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 �I Page 5 of 14 II O,Wmoletc. Allowable Substrates: Direct=Bond to Deck: Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber _Engineered Woods '21P System" Panels (designed and installed to meet wind loads -for project). Note: Polyglass does not require priming of new or existing plywood, or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G.TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G.FR torch -applied to: ➢ ASTM D41 primed, structural concrete. Band -to -Insulation: Polystick:(all'variations), Polyflex SAP or SAP FR. Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ ASTM C1289, Type il, Class 1 polyisocyanurate or Type V polyisocyanurate-composite Insulation; Dens Deck DuraGuard; Dens Deck Prime; or•SECUROCK Gypsum -Fiber Roof Board. Elastoflex G TU, Elastoflex S6 G or Elastoflex 56 G OR. in hot asphalt to: Dens Deck Prime or SECUROCK•Gypsum-Fiber Roof Board. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roofcovering manufacturer's Product• Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. Bond to Mechanically Attached Base Laver: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap'Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ➢ ASTM D226,Type I or II felt;•Elastobase; Elastobase P or Mule -Hide Nail -Base.. Elastoflex G TU,-Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch -applied to: ➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polygim APP Base. For installations under mechanically attached prepared roof coverings, . base layer.shall be attached -per minimum codified requirements: For installations under foam -on the systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. NEMO E4 , LLG Evaluation Report P12060.02.09-R24 cwt�cate i� Authodm6an N324SS . (P EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) Z33-1Z30 Revision 24: 01/24/2018 Page 6 of 14 I #6', #7 NEMO ETC, I.I.C. Wind Resistance for Underlayment Systems in Foam -On Tile Applications: • FRSA/TRI April 2012 (04412) does not address wind uplift resistance of all underlayment systems beneath foam -on the systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,.and reflects the -ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 -has already been applied). Refer to FRSA/TRI April 2012 (04- 12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. Maximum Design Pressure = -90 psf: Deck: Min. 15/ 32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. Maximum Design Pressure = -97.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction -of Authority Having Jurisdiction. Primer: PG100orASTM D41 . Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.. Underlayment: Polystick TU, P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back-nalled within the selvedge -edge side laps using 12 ga. x 1Y.." ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 124nch o.c. Maximum Design Pressure = -105 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000, Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered: Underlayment:- Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Palyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1'/," ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. Maximum Design Pressure = -135 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Joints: Min. 4-inch wide strips of Elastoflex SA-V overall plywood joints: Underlayment: Polystick TU P, Polystick TU- Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-AP.P Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR),'self-adhered. Maximum Design Pressure = -315 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply:. (Optional)Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP'Cap Sheet (FR), self -adhered. Maximum Design Pressure = -622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of. Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mapping of hot asphalt or Polyflex G, torch -applied. Maximum Desian Pressure = -30.0 psf•: . Deck: Min. 15/32-inch.OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.254nch long x 1-inch head diameter round metal. cap nails Spacing: 6-inch o:c. at the 3-inch wide side laps and 64nch a.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and . Mule -Hide SA-APP Cap Sheet (FR),.self-adhered. Evaluatlbn Report P12060.02.09-R24 #32455 6TN. EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-3230 Revision 24: 01/24/2018 Page 7 of 14 N.NEMOJetc. Maximum Design Pressure =.-37.5 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails. Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment:•Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. 9 Maximum Design Pressure = -37.5 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch longx 1-inch head diameter round metal cap nails Spacing: 6-inch o.6 at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. do Maximum Design Pressure = -45 psf*: Deck: Mina 19/32-inch plywood to meet project.requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) layer ASTM D226, Type II.felt . Fasteners: it ga.'x 1,2S-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch a.c.'at two (2) equally spaced staggered center rows. ' Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP. Cap Sheet (FR), self -adhered or Elastoflex.G TU, applied in full mopping of hot asphalt. 111 1 Maximum Design Pressure = -45 psf*: Deck: Min. 19/32-inch plywood to meet.project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/84nch diameter tin caps Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering und6dayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (III self -adhered or Elastoflex G TU or Elastoflex S6 G, applied. in full mopping of hot asphalt. 12 Maximum Design Pressure = -45 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MA)X Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps.and 18-Inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. II Maximum Design Pressure = -52.5 psf:. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet:. . Elastobase (sanded top surface for hot_ -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex .MAXXCap Fasteners Spacing: 9-inch o.r_ at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. 14 Maximum Design Pressure = -52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base.(poly-film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU.Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA=APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. 'C, LLC. ofAuthor&ut(on 032455 6' EDITION (247) FBC NON-HVHZ EVALUATION Potyglass Roof Underlayments; (954) 23371230 Evaluation Report P12060.02.09-R24 FL5259-RZB Revision 24: 01/24/2018 Page 8 of 14 NEMO l etc. 5 Maximum Design Pressure = -52.5 psf: Deck: Min: 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface far torch -applied cap) Fasteners: Simplex Original.Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c, at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch=applied. #16 Maximum Design Pressure = -60 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter,annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and &inch, o.c, at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of -hot asphalt or Polyflex G, torch -applied. #111 7 Maximum'Desisn Pressure = -60 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction-. . Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastofiex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. # 8 Maximum Design Pressure =-67.5'psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet:. Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment). Fasteners: 12 ga, x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch'o.c, at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied, or Polyflex G, torch - applied. # �9 Maximum Design Pressure = -75 psf: 4 Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment) Fasteners: Dekfast #14 with Dekfast Hex plates, CMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation, Plates or Simplex MAXX Cap Fasteners Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G-TU or Elastoflex_ S6 G. applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. #2 P Maximum Design Pressure = -90 psf: , Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet:.. Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced, staggered center rows. Underlayment: Elastoflex G TU or.Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #21 Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners:. OMG 012 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c., at three (3) equally spaced staggered center rows. . Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.. #2- Maximum Design Pressure = -90 psf: Deck: Min. 15/324nch plywood to meet project requirements to satisfaction of Authority Having jurisdiction: Base Sheet: Elastobase .(sanded top surface). Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered -center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. NEMO ETC, LLC. Evaluation Report P12060.02.09-R24 certificate �I fAuthorimtinn #32455 � O EDI710N (2017) FBC NON-HVHZ EVALUATION 'FL5259-R28 PollWass Roof Underiayments; (954) 233-2230 Revision 24: 01/24/2018 ,� Page 9 of 14 ONEMOletc. Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass 62 Base or Polyglass APP Base (requires use of torch -applied underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing. 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. Maximum Design Pressure = -97.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered centerrows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. Maximum Design Pressure = -105 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied. Maximum Design Pressure = -112.5 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jur Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four. (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin -caps Base Ply: Polystick MTS or Polystick MTS PLUS, self -adhered Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, PolyflexSAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. Maximum Design Pressure = -120 psf: Deck: ' Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3", Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps'and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU. or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. Maximum Design Pressure = -120 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. . All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of-45 psf. ETC, LLC. rte of Authorization N32455 If H EDITION (2017) FBC NON-HVHZ EVALUATION Polyglass Roof Underlayments; (954) 233-1230 Evaluation Report P12060.02.09-R24 FL5259-R28 Revision 24: 01/24/2028 Page 10 of 14 0 NEMIO I etc For mechanically'attached Base, Sheet, the maximum -design pressure for the.selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A-. Alternatively, the' maximum design pressure for the selected assembly shall meet, or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employan attachment density designed by a qualified. design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in'Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.. ExDOSure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be,left ezposed.for longer than 30-days after installation. Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation. Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longerthan,180-days after. installation. Polyflex SAP or SAP FR,. or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which. case the maximum exposure is 30. days. Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared. roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days.. Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller,.as set forth in.Section 4.3, Note 1 of •ASTM D1970-15, should be established as to slip. resistance. Tile Slippage Limitations (FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment In direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.. t2`,t�TJLEiso AG�,.l:ll�ll,(T�1T�ONS.FORD,DI�IEI'rT*'DECK�'�ILE..IP�S�ALIA�IOMS y:.�.��:�jd;•r+��'=„it.�`."tu,.-x?.. +, V .0 -. r. ,., � U;nderlayment Tile, Profile Staging Method Maximum Slope IIJ . Eflastoflex G TU Flat , , 10-tile stack 7:12, Lugged 8-tile stack (6 over 2) -.6:12 E astoflex S6 G or S6 G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 II Plystick MTS or MTSPLUS o III . Flat 6-tile stack'(4 over 2) .. 5:12 Lugged 6-tile stack (4 over 2) 4:12 ••,,olystick Tile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 l` Iolystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 Lugged 10-tile stack 6:12 I olystick TU P Flat 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 4:12 III polystick TU Plus Flat or Lugged 6-tile stack (4 over 7:12 . Flat or Lugged 10-tile stack 6:12 ��olyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 jPoly lei SA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 4M NIO ETC, LLC Evaluation ReportP12060.02.09-R24 i rate ofAuthor&atlan A32455 6T" EDITION (Z017) FBC NON-HVHZ EVALUATION FL5259-RZB Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 11 of 1'4 6. OMEMO I etc. Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.13.1 Non -Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex 6 or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 63.2 Tile Applications: Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the `Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April 2012 (04-12) Installation Manual. Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment In FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Direct -to -Deck with Mechanically Fastened Roof Covers: All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule - Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or. Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in'area marked "nail area, area pare clever" on the face of membrane. The head lap membrane is to cover the area being back -nailed. All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). View of ovelap Seam of Dual Pro and Tile Pro All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details ETC, I.I.C. Evaluation Report P12060.02.09-R24' ate of Authorization #32455 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZB Polyglass Roof Underlayments;1954) 233-1230 Revision 24: 01/24/2018 Page 12 of 14 MEMO j etc. Repair of Polystick membranes is to be accomplished by applying, Polyplus So Premium Modified Wet/DryCement or Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps ('min. 28 lb roller)' or small areas of the roof that are not accessible to a large roller or broom. r .3 Tile Applications (not dllowed for Poystick Dual Pro, IR Xe or Polystick MU f): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing_ over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table L For adhesive -set tile applications, refer to Section S.6.4 herein. .4 Two (2) Ply Underlayment Systems: Polystick MTS or.MTS PLUS followed, by Polystick MTS, MTS PLUS, TU_ P; TU Plus, TU Max, Tile Pro; MU-X or Polyflex SAP is allowable for use under mechanically attached prepared, roof systems. Limits of use are those associated -with the top -layer material. This Is not a requirement, but is allowable if a 2-ply underlayment system is desired. Polystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use under foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply.underlayment system is desired. 615.1 Elastoflex G TU, Elastaflex S6 G or.Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Elastoflex G TU is for use as an alternate to "Mineral Surface.Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April.2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt C applied "Cap Sheet" in the "Two Ply System from FRSA/TRI April 2012 (04-1.2) beneath mechanically fastened or* adhered tile roof systems. ✓ Elastoflex'S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System"'from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the `Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll, Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the "rwo Ply System" from FRSA/TRI.April 2622 (04-12) beneath mechanically fastened tile roof systems. 8.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex 56 G FIR shall be fully asphalt -applied to the P substrates noted in Section 5.6. Side laps shall be. minimum 3-inch and end -laps minimum 6-Inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the.lap.edge. 6:1 Polyflex,G'or Polyflex G Fit shall be installed in compliance with current Polyglass published installation requirements. For use in the applications: ✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the `Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3). ✓ Polyflex G FA is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile.roof.systems (Base Sheet Limited per 5.6.3). O ETC, LLC. Evaluation Report P12060.02.09-R24 [� mte of Author&otion #32455. a EDITION 12017) FBI NON-HVHZ EVALUATION FL5ZS9-R28 Polyglass Roof Underleyments; (934) 233-1230 Revision 24: 01/24/2018 Page 13 of 14 f 7. 8. NEI C. NEMO l etc. .6.2 Polyflex G or Polyflex G. FR shall be fully torch=applied to,the substrates noted in' Section 5.6. Side laps shall be, minimum 3-'inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course.. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap Yedge. . .7 Tile Stas)na: 6 7.1 Tile shall be loaded and staged in.a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table-2 herein, and Polyglass published requirements for tile staging. .7.2 Battens and/or Counter -battens, as required by the the manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:22. Precautions should be taken -as needed, such as the use of battens or nail - boards, to prevent tile sliding and/or damage to the underlayment during the loading process. .7.3 Polygiass specifies the minimum cure time after Installation of.self=adhering membranes and•before loading of, roofing tiles.is forty-eight (48) hours. �UILDING.PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the -installation of this product. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. ;aRiant::._ �ASTM Polystick MU-X Fernley, NV, Hazleton, PA &Winter Haven, FL D19.70 Hazleton, PA M-D 13-0004 Elastoflex G TU ASTM D1970 Polystick IR-Xe ASTM D1970 & F1RSA/TR1 April 2012 Polystick TU Plus Hazleton, PA & Winter Haven, FL ASTM D1970 & FRSA/TRI April 2012 Polystick TU Max. Tuscaloosa, AL' . ASTM D4601; Type II Polyglass G2 Base ASTM D226 (physicals) Elastobase, Elastobase P ASTM D6509 Polyglass APP Base FRSA/TRI April 2012 Polystick MTS, Polystick MTS PLUS FRSA/TRI April 2012 Polystick TU P FRSA/TRI A ril.2012 Polyflex SAP, Polyflex SA P FR Winter Haven, FL ASTM D1970 Polystick Dual Pro ASTM D1970 & FRSA/TRI April 2012 Polystick Tile Pro MTM D6164 Elastoflex S6, Elastoflex S6 G FR ASTM D6222 PolyFlec G, Polyflex G FR QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT- �O ETC, U.C. Evaluation Report P12060.02:09-1124 riicate ofAutharkation A32455 6t" EDITION (2017) FBC NON-HVH2 EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 14 of 14 i f