Product Approval
USER: Publlc User
i
�rr RECEIVED
IIIProduct Aooroval Menu > �Qr duct or Aoollratlon Search > Aoolicatlan UR > Applioetion Detail
FL # FL5259-R28 J U L 16 2018
Application Type Revision
Code Version 2017 ST, Lucie County, Permitting
Application Status Approved
Comments '
Archived ❑
Product Manufacturer POLYGLASS USA" .
'Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1378- Ext 242
alender@polyglass.com
Authorized Signature Arel Lender
alender@polyglass.com
Technical Representative Maury Alpert
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912)429-8610
MAlpert@polyglass.comm
Quality Assurance Representative Apel Lender
Address/Phone/Email 1111 W. Newport.Center Drive
Deerfield. Beach, FL 33442 .
(954) 233-1230
ALender@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer ,
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/05/2018 _ .
Validated By John W. Knezevich, PE
0 Validation Checklist - Hardcopy Received
certiflcate of Independence FI 5259 R28 COI 2018 01 COI NIEMINEN odf
Referenced Standard and Year (of Standardj Standard Year
ASTM D1970' 2015
ASTM D226 2009
ASTM D4798 2011
ASTM D6164 2011
VI ASTM D6222 2011
FM 4474 2011
FRSA/TRI April 2012 2012
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
01/24/2018
Date Validated
01/29/2018
Date Pending FBC Approval
01/30/2018
Date Approved
04/10/2018
Summary of Products
FL #
Model, Number or Name
Description
5259.1
i lyglassFRoof, -
jrWerj4y -
do ' g nde aymer is
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL5259 R28 11 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R28.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nleminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other:. 1.) The design pressure In this
Evaluation Reports
application relates to one particular
FL5259 R28 AE 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R28.odP
underlayment system (over concrete deck)
for use under foam -on tile systems (where
Created by Independent Third Party: Yes
the underlayment forms part of the load -
path). Refer to ER Section 5.6.4 for other
systems, other deck types and associated
maximum design pressures. 2.) Refer to
ER Section 5 for other limits of use:
Back Next
Contact Us:; 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Coovriaht 2 07-2013 State of Florida.:: Privacy Statement ;: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mall address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The
emaiis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please
click e e .
Product Approval Accepts:
Credit Card
Safe
(954) i
SCOPE:
This E
for use
describi
herein.
Quality
produ
distribute
This Evalt
Preparedly
NEMp etc.
Certii lcate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
EVALUATE TEST CONSULT CERTIFY
ION REPORT
USA, Inc.
t Newport Center Drive
Beach, FL 33442
Evaluation Report P12060.02.09=111124
FL5259-R28
Date of Issuance: 02/24/2009
Revision 24:.01/24/2018
ation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use. of
m materials in the State of Florida. The. documentation submitted has been reviewed by RobertNieminen, .E.
the product under the Florida Building Code and. Florida Building Code, Residential Volume. The products
herein have been. evaluated for compliance with the 6u' Edition (2017) Florida Building Code sections noted
N:�Po'.,glass• ,gnfilJnde-ftyme11TS1 6
Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
i COMPLIANCE: This- Evaluation Report- is valid until such time as the named product(s) changes, the referenced
surance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
i Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
1 Report relative to updated Code requirements with each Code cycle.
RENT: The Evaluation Report number preceded by the. words "NEMOIetc. Evaluated' may be 'displayed in
literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
Upon request, a copy of this entire. Evaluation Report shall be provided to the user by the manufacturer or its
sand shall be available for inspection at the job site at the request of the Building Official.
ation Report consists Of pages 1 through 14.
RobertJ.1l. Nieminen, P.E..
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal, appearing was authorized by Robert Nleminen,
P.E. on 01/24/2018. This does not serveas an electronically
signed document.
CERTIFICATI& OF INDEPENDENCE:
1. NEMO�i
�etc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distrib-III tin, products it evaluates.
2. NEMO etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Roberhl ieminen, P.E. does not have nor will acquire, a financial interest in any company_ manufacturing or distributing products for
which he evaluation reports are being issued.
4. Robert�lf ieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
. produa.
s. This is building code evaluation. Neither NEMO Ietc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any
project lion which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifi(,:ally for that purpose.
r
1.
2.
3.
EVALUATION:
NNEMO etc.
Category: Roofing
agory: Underlayment
nce Statement: Roof Underlayrnents, as produced by Polyglass USA, Inc., have. demonstrated compliance with the
sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards.
nce is subject to the Installation Requirements and, Limitations / Conditions of Use set forth herein.
IYYAlfYJ:
'
Lion
Pro a
Standard _
Year
1.3.1
Wind Uplift
FM 4474
2011
t.3.1
Wind Uplift
UL 1897
2012
7.2.3 / 1507.1.1
Physical Properties
ASTM D226
2009
7.2.4 / 1507.1.1,1507.2.9.2
Physical Properties
ASTM D1970
2015
7.3.3
Physical Properties
FRSA/T.RI April 2012
2012
7.11.2 -
Physical Properties
ASTM D6164
2011
?.11.2
Physical Properties
ASTM D6222
2012
110
Accelerated Weathering
ASTM D4798
2011
Approvals (TST 1867)
(TST 5878)
(TST 5878)
(TST 5878)
(TST 5878)
(TST 5878)
(TST 5878)
(TST 5878)
(TST 5878)
(TST 5878)
(TST 5878)
(TST 5878)
(TST 5878)
(TST 5878)
(TST 5878)
1(TST 2508)
I(TST _2508)
)(TST 6049)
)(TST 6049)
) (TST 6049)
)(TST 6049)
) (TST 6049)
)(TST 6049)
) (TST 6049)
(TST 6049)
(TST 6049)
)(TST 6049)
(TST 6049)
(TST 6049) .
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
NEMO &C LLC.
CertfficatAafAutharizanan #32455
Examination
Wind Uplift .
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Wind Uplift
Wind Uplift
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Reference
3004091 .
PRI61111
PUSA-005-02-01
PUSA-013-02-01
PUSA-013-02-02
PUSA-013-02-03
PUSA-018-02-01
PUSA-028-02-01
PUSA-033-02-01
PUSA-035-02-01
PUSA-055-02-02
PUSA-061-02-02
PUSA-076-02-01
PUSA-083-02-01
PUSA-088-02-01
JX20H7A
RX14EBA
11752.09.99-1
11757.08.01-1
11776.06.02
02200.07.03
P1740.01.07
P5110.04.07-1
P9260.03.08
P13450.08.09
P30540.11.09-R1
P11030.11.09-1-
P11030.11.09-2
P11030.11.09-3
P33360.06:10
.P33370.03,11
P33370.04.11
P37300.10.11
e EDITION (2017) FBC NON-HVHZ EVALUATION
Polyglass Roof Underlayments; (954) 233-1230
Date
01/12/2000
04/08/2002
01/31/2002
12/23/2002
12/23/2002
12/23/2002
07/14/2003
07/13/2005
01/12/2006
09/29/2006
12/10/2007
01/28/2008
02/22/2008
04/14/2008
07/29/2009
04/01/2008
01/29/2009
02/08/2000
08/13/2001
61/16/2003
07/14/2003
01/04/2007
04/11/2007
03/21/2008
08/13/2009
11/30/2009
11/30/2009•
11/30/2009
11/30/2009
06/25/2010
03/02/2011
04/26/2011
10/19/2011
Evaluation Report P12060.02.09-1124 '
FL5259-RZB
Revision 24: 01/24/2018
Page 2 of 14
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
(TST 6049)
:S (EVL 2396)
ni-Dade (CER 1592)
-lass USA
;lass USA
;lass USA
I.C. (QUA9625)
4. PRODUCT DESCRIPTION:
Examination
Physical Properties
Physical Properties
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Physical Properties
Physical -Properties
Physical Properties
IBC Compliance
HVHZ Compliance
Manufacturing Affidavit
P/L Affidavit
Materials Affidavit
Quality Control
Reference
P40390.08.12-1
P40390.08.12-2
C41420.09.12-3 . .
P39680.03.13
P45370.04.13
P1738.02.07-112
11757.04.01-1-R1
P41630.08.13
P11751.05.03-R1
P11781.11.03-R1
P45270.05.14
6020.07.14-1
6020.09.14-2
6020.09.14-3
6020.09.14-4
6020.09.14-5
6020.09.14-6
P46520.10.14
P43290.10.14
PLYG-SC7550.03.15
P40390.04.15
P44360.10:14-R1
PLYG-SC8080.05.15=1
PLYG-SC8905.05.16-1
PLYG-SC8080.07.16
PLYG-SC12025.10.16
PLYG-SC13040.12.16
PLYG-SC11900.03.17
PLYG-SC12115.08.17
ESR-1697
NOA 14-0717.08
Products Current
Mule -Hide Cross Ltg
Polystick SA Compound
Service Confirmation
4.14 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1�2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.11j3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
11
4.44 Polyglass APP Base is a fiberglass=reinforced, APP modified bitumen base sheet.
ONEMO I etc.
Date
08/06/2012
08/07/2012
09/11/2012
03/04/2013
04/26/2013
04/29/2013
04/30/2013
08/06/2013
11/26/2013
11/26/2013
05/12/2014
09/08/2014
09/08/2014
09/08/2014
09/08/2014
09/08/2014
09/08/2014
1.0/03/2014
10/17/2014
03/24/2025
04/03/2015
05/18/2015
05/20/2015
05/17/2016
07/16/2016
10/22/2016
12/27/2016
03/10/2017
08/08/2017
11/01/2014
01/22/2015
02/18/2009
03/01/2008
08/18/2011
Exp.10/05/2018
P8lystiIE IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
Polystick TU Plus Is a nominal 80-mil thick rubberizedasphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012.
NEMO ETC, I.I.C. Evaluation Report P32060.02.09-R24
Certykate l Authadzation #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28
Polyglass_ Roof Underlayrnentsl (954) 233-1230 Revision 24: 01/24/2018
Page 3 of 14
5.
fONEMOjetc.
.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface, meets FRSA/TRI April 2012.
.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface; meets ASTM D1970 and FRSA/TRI April 2012.
.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester
ireinforced,.APP modified bitumen cap sheets; meet FRSA/TRI April 2012.
2.7 Polystick Dual PrW" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
8 Polystick Tile Pro' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012.
2 9 Polystick - MU-X is a nominal 54-mil thick dual -layer rubberized asphalt. waterproofing . membrane, fiberglass
reinforced, with a polypropylene'film surface; meets AC188 and. physical requirements of ASTM D1970 (See Section
'I 5.8).
3� 1 Elastoflex G. TU is a polyester reinforced, modified bitumen the underlayment composed of a. sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen top -side. -Elastoflex G TU Is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System"from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the 'Two Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
3�12 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; -meet ASTM D6164.
Elastoflex S6 G and. Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M) in the "Single Ply System". from FRSA/TRI April'2012 (04-12) beneath mechanically fastened tile roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the 'Two Ply System" from FRSA/TR!
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System":from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened the roof systems. ,
13 - Polyflex G and Polyflex -G FR-are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 203-2
(04-12) beneath mechanically fastened or adhered the roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
5.2'1
5.31
5.4
This ls' a building. code evaluation. Neither NEW I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
This Evaluation Report is not for'use in the HVHZ.
Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval. documents. If .not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with'supporting data for the prepared roof covering.
NEW ET�7, LLC. 1x
Certitate ofAutharizatlan A324SS 6 EDITION 12017) FBC NON-HVHZ EVALUATION
Polyglass Roof Underlayments; (954) 233-1230
Evaluation Report P12060.02.09-R24
FL5259-R28
Revision 24: 01/24/2018
Page 4 of 24
ONEMO I etc.
Allowable Roof Covers:
ri'i;,
`` r .. r , ✓ - ` TAB�Ft OOFCOYEQ Q ONS aau
a
�,
Un�derlayment
Asphalt Shingles
Nall -On The
Foam -On 711e
Metal
Wood Shakes
&Shingles
Slate
Elastobase
'I
YeS
Yes
(Base Sheet in 2-ply system)
Yes.
(Base Sheet In 2-ply system)
Yes
Yes
Yes
Eliistobase
P
Ye5
es
(Base SheetYn 2-ply system)
es
n 2-phj system)
(Base Sheet in
Yes
Yes
Yes
PoI
l
yglass G2 Base
No
(Base Sheet Yn 2-ply system)
(Base Sheet In 2-ply system)
No
No
No
Polass APP Base
l�g
Ili
No
Yes
(Base Sheet In 2-ply system)
Yes
(Base Sheet In 2-ply system)
No
No
No
Polystick NITS or MTS PLUS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Po:Iystick TU P
No
Yes
Yes (See 5.5.1)
No
No
No
Polystick TU Plus
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
PolystickTUMax
No
Yes
Yes (See 5.5.1)
Yes
No
No
Po jstick Dual Pro
Yes
No
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
Elastoflex S6 G
Yes.
Yes
Yes (See 5.5.1)
No
Yes
Yes
Ela4oflex S6 G FR
Yes
Yes
No
No
Yes
Yes
Ela toflex G TU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G
Yes.
Yes
Yes (See 5.5.1)
No
Yes
Yes
PololexGFR
Yes
Yes
No
No
Yes
Yes
PolyflexSAPorSAP FR
Yes
Yes
Yes (See5.5.1)
No
Yes
Yes
Mu ie-Hide SA-APP Cap Sheet
or A-APP Cap Sheet (FR)
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
�I
5.5,',1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
s
_. `TABLEIZA
4
„i411 ONIABLE �ILE /�DHESII/EIMUNAER0YME117T
CO BINA710N5 ; r, `. -
i
Adhesive
Florida Product
Underlayments
Approval
DAPI Foam Touch'n Seal StormBond Roof
Tile�Adhesive
FL14506
Polystick TU Plus, Polystick TU Max
Doll TileBondTM
FL22525
Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
ICP it dhesives Polyset® AH-160
FL6332
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
II II
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
II
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
lCP dhesives Polyset® RTA-1
FL6276
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
I I
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, U.C. Evaluation Report P12060.02.09-R24
Ceri lcate!6f Autharlmtlan #32455 6t" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZB
Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018
�I
Page 5 of 14
II
O,Wmoletc.
Allowable Substrates:
Direct=Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber _Engineered Woods '21P System" Panels
(designed and installed to meet wind loads -for project).
Note: Polyglass does not require priming of new or existing plywood, or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G.TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G.FR torch -applied to:
➢ ASTM D41 primed, structural concrete.
Band -to -Insulation:
Polystick:(all'variations), Polyflex SAP or SAP FR. Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
➢ ASTM C1289, Type il, Class 1 polyisocyanurate or Type V polyisocyanurate-composite Insulation; Dens Deck
DuraGuard; Dens Deck Prime; or•SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex 56 G OR. in hot asphalt to:
Dens Deck Prime or SECUROCK•Gypsum-Fiber Roof Board.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roofcovering manufacturer's Product• Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap'Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
➢ ASTM D226,Type I or II felt;•Elastobase; Elastobase P or Mule -Hide Nail -Base..
Elastoflex G TU,-Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch -applied to:
➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polygim APP Base.
For installations under mechanically attached prepared roof coverings, . base layer.shall be attached -per minimum
codified requirements: For installations under foam -on the systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
NEMO E4 , LLG Evaluation Report P12060.02.09-R24
cwt�cate i� Authodm6an N324SS . (P EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28
Polyglass Roof Underlayments; (954) Z33-1Z30 Revision 24: 01/24/2018
Page 6 of 14
I
#6',
#7
NEMO ETC, I.I.C.
Wind Resistance for Underlayment Systems in Foam -On Tile Applications: • FRSA/TRI April 2012 (04412) does not
address wind uplift resistance of all underlayment systems beneath foam -on the systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads,.and reflects the -ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 -has already been applied). Refer to FRSA/TRI April 2012 (04-
12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
Maximum Design Pressure = -90 psf:
Deck: Min. 15/ 32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
Maximum Design Pressure = -97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction -of Authority Having Jurisdiction.
Primer: PG100orASTM D41 .
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered..
Underlayment: Polystick TU, P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back-nalled within the selvedge -edge side laps using 12 ga. x
1Y.." ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 124nch o.c.
Maximum Design Pressure = -105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000,
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered:
Underlayment:- Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Palyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1'/," ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
Maximum Design Pressure = -135 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Joints: Min. 4-inch wide strips of Elastoflex SA-V overall plywood joints:
Underlayment: Polystick TU P, Polystick TU- Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-AP.P Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR),'self-adhered.
Maximum Design Pressure = -315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply:. (Optional)Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP'Cap Sheet (FR), self -adhered.
Maximum Design Pressure = -622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of. Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mapping of hot asphalt or Polyflex G, torch -applied.
Maximum Desian Pressure = -30.0 psf•: .
Deck: Min. 15/32-inch.OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.254nch long x 1-inch head diameter round metal. cap nails
Spacing: 6-inch o:c. at the 3-inch wide side laps and 64nch a.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
. Mule -Hide SA-APP Cap Sheet (FR),.self-adhered.
Evaluatlbn Report P12060.02.09-R24
#32455 6TN. EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28
Polyglass Roof Underlayments; (954) 233-3230 Revision 24: 01/24/2018
Page 7 of 14
N.NEMOJetc.
Maximum Design Pressure =.-37.5 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails.
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment:•Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
9 Maximum Design Pressure = -37.5 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch longx 1-inch head diameter round metal cap nails
Spacing: 6-inch o.6 at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
do Maximum Design Pressure = -45 psf*:
Deck:
Mina 19/32-inch plywood to meet project.requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
One (1) layer ASTM D226, Type II.felt .
Fasteners:
it ga.'x 1,2S-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps
Spacing:
4-inch o.c. at the 2-inch wide side laps and 4-inch a.c.'at two (2) equally spaced staggered center rows. '
Base Ply:
(Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP. Cap Sheet (FR), self -adhered or Elastoflex.G TU, applied in full mopping of hot asphalt.
111 1 Maximum Design Pressure = -45 psf*:
Deck:
Min. 19/32-inch plywood to meet.project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Two (2) layers ASTM D226, Type II felt
Fasteners:
11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/84nch diameter tin caps
Spacing:
9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply:
(Optional; for use with self -adhering und6dayment only) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (III self -adhered or Elastoflex G TU or Elastoflex S6 G, applied. in full mopping of hot
asphalt.
12 Maximum Design Pressure = -45 psf:
Deck:
Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex MA)X Cap Fasteners
Spacing:
9-inch o.c. at the 2-inch wide side laps.and 18-Inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
II Maximum Design Pressure = -52.5 psf:.
Deck:
Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:.
. Elastobase (sanded top surface for hot_ -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex .MAXXCap Fasteners
Spacing:
9-inch o.r_ at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
14 Maximum Design Pressure = -52.5 psf:
Deck:
Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base.(poly-film top surface)
Fasteners:
Simplex Original Cap Nails
Spacing:
6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply:
(Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU.Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA=APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
'C, LLC.
ofAuthor&ut(on 032455
6' EDITION (247) FBC NON-HVHZ EVALUATION
Potyglass Roof Underlayments; (954) 23371230
Evaluation Report P12060.02.09-R24
FL5259-RZB
Revision 24: 01/24/2018
Page 8 of 14
NEMO l etc.
5 Maximum Design Pressure = -52.5 psf:
Deck: Min: 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface far torch -applied cap)
Fasteners: Simplex Original.Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c, at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch=applied.
#16 Maximum Design Pressure = -60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter,annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and &inch, o.c, at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of -hot asphalt or Polyflex G, torch -applied.
#111
7 Maximum'Desisn Pressure = -60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction-.
.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastofiex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
# 8 Maximum Design Pressure =-67.5'psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:. Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment).
Fasteners: 12 ga, x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch'o.c, at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied, or Polyflex G, torch -
applied.
# �9 Maximum Design Pressure = -75 psf:
4 Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, CMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation, Plates or Simplex MAXX Cap
Fasteners
Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G-TU or Elastoflex_ S6 G. applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#2 P Maximum Design Pressure = -90 psf: ,
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:.. Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced, staggered center rows.
Underlayment: Elastoflex G TU or.Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:. OMG 012 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c., at three (3) equally spaced staggered center rows. .
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied..
#2- Maximum Design Pressure = -90 psf:
Deck: Min. 15/324nch plywood to meet project requirements to satisfaction of Authority Having jurisdiction:
Base Sheet: Elastobase .(sanded top surface).
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered -center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMO ETC, LLC. Evaluation Report P12060.02.09-R24
certificate �I fAuthorimtinn #32455 � O EDI710N (2017) FBC NON-HVHZ EVALUATION 'FL5259-R28
PollWass Roof Underiayments; (954) 233-2230 Revision 24: 01/24/2018
,� Page 9 of 14
ONEMOletc.
Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass 62 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing. 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
Maximum Design Pressure = -97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered centerrows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
Maximum Design Pressure = -112.5 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jur
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four. (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin -caps
Base Ply: Polystick MTS or Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, PolyflexSAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
Maximum Design Pressure = -120 psf:
Deck: ' Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3", Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps'and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU. or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
Maximum Design Pressure = -120 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. .
All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum
Design Pressure of-45 psf.
ETC, LLC.
rte of Authorization N32455 If H EDITION (2017) FBC NON-HVHZ EVALUATION
Polyglass Roof Underlayments; (954) 233-1230
Evaluation Report P12060.02.09-R24
FL5259-R28
Revision 24: 01/24/2028
Page 10 of 14
0
NEMIO I etc
For mechanically'attached Base, Sheet, the maximum -design pressure for the.selected assembly shall meet or exceed
that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A-.
Alternatively, the' maximum design pressure for the selected assembly shall meet, or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employan attachment density
designed by a qualified. design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in'Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements..
ExDOSure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be,left ezposed.for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for
longerthan,180-days after. installation.
Polyflex SAP or SAP FR,. or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which. case the maximum exposure is 30.
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared. roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days..
Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller,.as
set forth in.Section 4.3, Note 1 of •ASTM D1970-15, should be established as to slip. resistance.
Tile Slippage Limitations (FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment In direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles..
t2`,t�TJLEiso AG�,.l:ll�ll,(T�1T�ONS.FORD,DI�IEI'rT*'DECK�'�ILE..IP�S�ALIA�IOMS y:.�.��:�jd;•r+��'=„it.�`."tu,.-x?..
+, V .0 -. r. ,.,
�
U;nderlayment
Tile, Profile
Staging Method
Maximum Slope
IIJ .
Eflastoflex G TU
Flat , ,
10-tile stack
7:12,
Lugged
8-tile stack (6 over 2)
-.6:12
E astoflex S6 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
II
Plystick MTS or MTSPLUS
o
III .
Flat
6-tile stack'(4 over 2) ..
5:12
Lugged
6-tile stack (4 over 2)
4:12
••,,olystick Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
l`
Iolystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
I
olystick TU P
Flat
6-tile stack (4 over 2)
6:12
Lugged
6-tile stack (4 over 2)
4:12
III
polystick TU Plus
Flat or Lugged
6-tile stack (4 over
7:12
. Flat or Lugged
10-tile stack
6:12
��olyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
jPoly lei SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4M
NIO ETC, LLC Evaluation ReportP12060.02.09-R24
i rate ofAuthor&atlan A32455 6T" EDITION (Z017) FBC NON-HVHZ EVALUATION FL5259-RZB
Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018
Page 11 of 1'4
6.
OMEMO I etc.
Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.13.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex S6 G FR in hot asphalt or Polyflex 6 or Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1.
63.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the `Two
Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April 2012 (04-12) Installation Manual.
Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment
In FBC Table 1507.1.1 for the type of prepared roof covering to be installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch
diameter metal disk or. Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -
nailed using the above noted fasteners and spacing, in'area marked "nail area, area pare clever" on the face of
membrane. The head lap membrane is to cover the area being back -nailed.
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
View of ovelap Seam of Dual Pro and Tile Pro
All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
ETC, I.I.C. Evaluation Report P12060.02.09-R24'
ate of Authorization #32455 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZB
Polyglass Roof Underlayments;1954) 233-1230 Revision 24: 01/24/2018
Page 12 of 14
MEMO j etc.
Repair of Polystick membranes is to be accomplished by applying, Polyplus So Premium Modified Wet/DryCement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps ('min. 28 lb roller)' or small areas of the
roof that are not accessible to a large roller or broom.
r .3 Tile Applications (not dllowed for Poystick Dual Pro, IR Xe or Polystick MU f):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing_ over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table L
For adhesive -set tile applications, refer to Section S.6.4 herein.
.4 Two (2) Ply Underlayment Systems:
Polystick MTS or.MTS PLUS followed, by Polystick MTS, MTS PLUS, TU_ P; TU Plus, TU Max, Tile Pro; MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared, roof systems. Limits of use are those associated -with
the top -layer material. This Is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Polystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use
under foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement,
but is allowable if a 2-ply.underlayment system is desired.
615.1 Elastoflex G TU, Elastaflex S6 G or.Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface.Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April.2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
C applied "Cap Sheet" in the "Two Ply System from FRSA/TRI April 2012 (04-1.2) beneath mechanically fastened or*
adhered tile roof systems.
✓ Elastoflex'S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System"'from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the `Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll, Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "rwo Ply System" from FRSA/TRI.April 2622 (04-12) beneath mechanically fastened tile
roof systems.
8.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex 56 G FIR shall be fully asphalt -applied to the
P substrates noted in Section 5.6. Side laps shall be. minimum 3-inch and end -laps minimum 6-Inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the.lap.edge.
6:1 Polyflex,G'or Polyflex G Fit shall be installed in compliance with current Polyglass published installation requirements.
For use in the applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the `Two Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3).
✓ Polyflex G FA is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened tile.roof.systems (Base Sheet Limited per 5.6.3).
O ETC, LLC. Evaluation Report P12060.02.09-R24
[� mte of Author&otion #32455. a EDITION 12017) FBI NON-HVHZ EVALUATION FL5ZS9-R28
Polyglass Roof Underleyments; (934) 233-1230 Revision 24: 01/24/2018
Page 13 of 14
f
7.
8.
NEI
C.
NEMO l etc.
.6.2 Polyflex G or Polyflex G. FR shall be fully torch=applied to,the substrates noted in' Section 5.6. Side laps shall be,
minimum 3-'inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course.. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
Yedge. .
.7 Tile Stas)na:
6 7.1 Tile shall be loaded and staged in.a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Table-2 herein, and Polyglass published requirements for tile staging.
.7.2 Battens and/or Counter -battens, as required by the the manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7:22. Precautions should be taken -as needed, such as the use of battens or nail -
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
.7.3 Polygiass specifies the minimum cure time after Installation of.self=adhering membranes and•before loading of,
roofing tiles.is forty-eight (48) hours.
�UILDING.PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the -installation of this product.
MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The following
plants have qualified products under their respective physical properties specifications.
;aRiant::._
�ASTM
Polystick MU-X
Fernley, NV, Hazleton, PA &Winter Haven, FL
D19.70
Hazleton, PA
M-D 13-0004
Elastoflex G TU
ASTM D1970
Polystick IR-Xe
ASTM D1970 & F1RSA/TR1 April 2012
Polystick TU Plus
Hazleton, PA & Winter Haven, FL
ASTM D1970 & FRSA/TRI April 2012
Polystick TU Max.
Tuscaloosa, AL' .
ASTM D4601; Type II
Polyglass G2 Base
ASTM D226 (physicals)
Elastobase, Elastobase P
ASTM D6509
Polyglass APP Base
FRSA/TRI April 2012
Polystick MTS, Polystick MTS PLUS
FRSA/TRI April 2012
Polystick TU P
FRSA/TRI A ril.2012
Polyflex SAP, Polyflex SA P FR
Winter Haven, FL
ASTM D1970
Polystick Dual Pro
ASTM D1970 & FRSA/TRI April 2012
Polystick Tile Pro
MTM D6164
Elastoflex S6, Elastoflex S6 G FR
ASTM D6222
PolyFlec G, Polyflex G FR
QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT-