Loading...
HomeMy WebLinkAboutCONSTRUCTION PLANr SHOP DRAWING 1 SUBMITTAL RE APPROVED ❑ APPROVED AS NOTED ❑ REVISE AND RESUBMIT ❑ REJECTED THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE ORDER DOCUMENTATION AND, THE APPLICABLE SECTIONS OF THE PROJECT SPECIFICATIONS, THE LOADS ARE APPLIED TO THE STRUCTURE IN ACCORDANCE WITH THE FOLLOWING AS INDICATED, CODE LOADS BUILDING CODE: FBC 17 LL• 20 psf, with tributary reduction allowed PRIMARY FRAMING: AISC10 COLLATERAL LOAD: 3 psf SECONDARY FRAMING: NAUS12 SNOW LOAD: Pg=0.0 psf Pf=0.0 psf Is=1.00 Ce=1.00 Ct=1.00 DEFLECTIONS WIND LOAD: 155 mph Vosd=120 mph Risk Category=ll Exposure=C RIGID FRAME: H/60 Internal Pressure Coefficient: V-6.18 Design Wind Pressure=46.01 psf RIGID FRAME: L/180 SEISMIC DESIGN DATA: Occupancy Category=ll Sds=0.061 Sd1=0.046 Site Class=D PURLINS: L/150 le= 1.00 Ss=0.057 S1=0.029 Seismic Design Category --A GIRTS: L/90 Seismic -force -resisting System ENDWALL COLUMNS: H/90 Steel Systems Not Specifically DetailedFor Seismic Resistance ENDWALL RAFTERS: L/180 R=3.00 Cs=0.0203 BRACING: H/60 V= 0.70 kips (Transverse) V= 0.68 kips (Longitudinal) Equivalent Lateral Force Procedure VIEW OTHER LOADS: (ONE) 50'-0" x 15'-0" Powerlift Hydraulic Door WIND DEFLECTIONS: 50 Year Mean Recurrence Wind Speed Components & 6laddin9 (Factored) Width Length Pressure(psf ) Suction(psf ) Zone (ft) (ft) Member Panel Member Penal 1 7.87 9194 -29.81 -32.57 2 6.00 7.87 994 -35.18 -54,72 3 6.00 7.87 994 -35.18 -54,72 4 6.00 6.00 7.87 %94 -35.18 -82,41 5 24.12 29i82 -26.58 -32,28 Fort Pierce, FL 34950 6 6,00 24.12 29 82 -28.44 -39,70 6 5 i 6 lli I 4 3 4 Yd 2 4 1 3 TBD TTO BE DETERMINED (PLEASE PROVIDE COLORS ON RETURNED DRAWINGS) ROOF 26Ga. MBCI PBR PANEL PANEL COLOR: TBD (UNICOTE 2000) WALL 26Ga. MBCI PBR PANEL PANEL COLOR: TBD (UNICOTE 2000) ROOF & WALL STD. GUTTER DOWNSPOUT RAKE CORNER TRIM TBD (UNICOTE 2000) TBD (UNICOTE 2000) TBD (UNICOTE 2000) TBD (UP 2 P] 4 `XAN EU BY St. Lucie councv, FASTENERS #12 SIDS MEMBER & LA(3TEK STITCH FASTENERS #12 SIDS MEMBER & LAPTEK STITCH JAMB & HEAD BASE TRIM (DPO1) IE 2000) TBD (UNICOTE 2000) TBD (UNICOTE 2000) d tl 9th Ed't' x GENERAL NOTES BUYER/END USE CUSTOMER RESPONSIBILITIES 1.1 Fabrication shall be in accordance with U.S.A.'s standard practices in 2.1 It is the responsibility of the BUYER/END USE CUSTOMER to obtain appropriate U compliance with the applicable sections, relating to design requirements approvals and secure necessary permits from City, County, State, or 0-1 and allowable stresses of the latest edition of the'AW'S Structural RecElVED Federal Agencies as required, and to advise/release U.S.A. to fabricate LU Welding Code D1.1". U.S.A.'s manufacturing procedures have been upon receiving such. :�E 0 certified by. JUL 2.2 United Structures of America's (hereafter referred to as U.S.A.) Q LLJ Reference Certification n ers 1�6 2018 standard specifications apply unless stipulated otherwise in the Contract ILL F- I.A.S. - AC472 HOUSTON FACILITY MB-149 Permlttln Documents. U.S.A.'s design, fabrication, quality criteria, standards, O Q I.A.S. - AC472 PORTLAND FACILITY MB-150 g Department St. Lucie practice, methods and tolerances shall govern the work with any other fin Of LLI U.S.A. County interpretations to the contrary notwithstanding. It is understood by both � Houston Parties that the. BUYER/END USE CUSTOMER is responsible for clarification of O $ 135 Inclusions or exclusions from the architectural plans and/or specifications. CL Texas Engineering Firm # 143 2.3 In case of discrepancies between U.S.A.'s structural steel plans and plans U or� MIAMI-DADE COUNTY q 16-0803.09 for other trades, U.S.A.'s plans shall govem. (Section. 3 AISC Code of O MEMBER MBMA Standard Practices) O 2.4 Approval of U.S.A. drawings and calculations Indicates that U.S.A. has fin Z 1.2 PRIMER correctly interpreted and applied the Contract Documents. This approval 0 - Shop primer paint is a rust inhibitive primer which meets the end constitutes the contractor/owners acceptance of the U.S.A.'s design LU performance of Federal Specification TT-P-664 and is U.S.A.'s standard w concepts, assumptions, and loading. (Section 4 AISC Code and MBMA 3.3.3) ~ color shown on contract. This paint is not intended for long term exposure Z to the elements. U.S.A. Is not responsible for any deterioration 2.5 Once the BUYER/END USE CUSTOMER has signed U.S.A.'s Approval Package and the of the shop primer paint as a result of improper handling and/or project is released for fabrication, changes shall be billed to the BUYER/ storage. U.S.A. shall not be responsible for any field applied END USE CUSTOMER including material, engineering and other costs. An additional paint and/or coatings. (Section 6.5 AISC Code of Standard Practice, ( A fee may be charged if the project must be moved from the fabrication and CORPORATE OFFICE 13th Edition) !, shipping schedule. 1912 BUSCHONG 1.3 GALVANIZED OR SPECIAL COATINGS: 2.6 The BUYER/END USE CUSTOMER is responsible for overall project coordination. All HOUSTON, TX 77039 Reference Contract Documents. Interface, compatibility, and design considerations concerning any materials not furnished by U.S.A. and U.S.A.'s steel system are to be considered and 281-442-8247 1.4 ALL BOLTS ARE 1/2" x 0'-i" A307 EXCEPT: coordinated by the BUYER/END USE CUSTOMER. Specific design criteria concerning PORTLAND FACILITY a) Eave strut connection - 1/2" x O'-1 1/4" A307 this interface between materials must be furnished before release for fabrication or U.S.A.'s assumptions will govern (Section 4 and Commentary, 214 FOUNTAINHEAD ROAD b) Main frame connections - SEE CROSS SECTION AISC Code of Standard Practice) PORTLAND, TN 37148 NOTE: Washers are not supplied unless noted otherwise on drawing 2.7 It is the responsibility of the BUYER/END USE CUSTOMER to insure that U.S.A.'s 615-325-7351 plans comply with the applicable requirements of any governing building authorities. The supplying of sealed engineering data and drawings for 1.5 MATERIALS ASTM DESIGNATION MINIMUM YIELD f U. N. 1 the metal building system does not Imply or constitute an agreement CO Wide Flange Shapes A572 or A992 FY = 50 KSI that U.S.A. or its design engineers are acting as the engineer of record Other Rolled MITI Shapes A36 or A572 FY = 36 KSI or 50 KSI or design professional for a construction project. These drawings are to Structural Steel Plate (Webs/Connections) A1011 or A572 FY = 55 KSI sealed only certify the design of the structural components furnished by U.S.A. ¢ o Structural Steel Plate (Flanges) A529 or A572 FY = 55 KSI 2.8 The BUYER/END USE CUSTOMER is responsible for setting of anchor bolts and v Cold Formed Light Gage Shapes A1011SS / HSLAS CLASS 1 FY = 55 KSI erection of steel in accordance with U.S.A.'s "For Construction° drawings Cable Bracing A475-78 Extra High Strength only. Temporary supports such as guys, braces, falsework, cribbing or Rod Bracing A36 FY = 36 KSI other elements required for the erection operation shall be determined Roof and Wall Sheeting A792 FY = 50 , 80 KSI and furnished and installed by the erector. No items should be purchased from Machine Bolts A307 FY = 36 KSI a preliminary set of drawings, including anchor bolts. Use only final p High Strength Bolts (1/2" to i°) A325-N FU = 120 KSI "FOR CONSTRUCTION DRAWINGS" for this use. (Section 7 AISC Code of F r­ High Strength Bolts (1 1 8" to 1 1/2") A325-N FU = 105 KSI Standard Practice.) Anchor Bolts (If supplied) F155A53, FY = 35 KSI Pipe A53, GRADE B FY = 35 KSI 2.9 United Structures of America is responsible for the design of anchor bolts to P 9 0 w a H.S.S. TUBE A500, GRADE C FY = 46 KSI permit the transfer of forces between the base plate and the anchor bolt in w o shear, bearing and tension, but is not responsible for the transfer of anchor bolt forces to the concrete or the adequacy of the anchor bolt in relation to the 1.6 HIGH -STRENGTH BOLT TIGHTENING REQUIREMENTS concrete. Unless otherwise provided in the Order Documents, United Structures of High Strength Bolts are ASTM A325-N, unless otherwise noted. America does not design and is not responsible for the design, material All high strength bolts shall be snug -tight unless otherwise specifically noted and construction of the foundation or foundation embedment's. The END USE CUSTOMER should assure himself that adequate provisions are made N a for particular connection details. in the foundation design for loads imposed by column reactions of the building, '•�, Moment Frames and Moment Connections shall be fully- pretensioned where other imposed loads, and bearing capacity of the soil and other conditions of the building site. _ noted on drawings. Tension -Control Bolts and/or Load Indicating washers It is recommended that the anchorage and foundation of the building be _. shall be supplied by PEMB where shown on drawings. designed byReg'stered Professional Engineer experienced in the design Tum-of-the-nut and calibrated wrench method are also acceptable means. ,a of such structures. (Section IV MBMA Low Rise Building Systems Manua) NOTE: The Pre -Installation verification procedure requires the use of a "tension calibrator', 2.10 Normal erection operations include the corrections of minor misfits by ' which is a hydraulic tension indicating device, such as a Skidmore Testing Device. moderate amounts of reaming, chipping, welding or cutting, and the All ASTM A325 bolts are provided with lubricated nuts. The erector should employ drawing of elements into line through the use of drift pins. Emorswhich cannot be corrected by the foregoing means or which require z a proper job site handling and storage procedures to protect fastener assemblies against major changes in member configuration are to be reported immediately 4, excessive weathering and exposure to dust, dirt, moisture, heat, ect. Depending to U.S.A. by the BUYER/END USE CUSTOMER, to enable whoever is responsible N on job site handling and the severity of job site conditions, It may be necessary to either to correct the error or to approve the most efficient and economic N w a no re-Iubrlcate the nuts. The necessity for reapplying lubricant may be determined by pre -installation verification as reference above. For additional Information on job site method of correction to be used by others. (Section 7 AISC Code of St d P Ot �" UO > storage and handling, see AISC 13th Ed., Choper 16.2, Section2.2• an or roc ce, i loin) ? N J Li s,. 2.11 _FIELD MODIFICATIONS - WARNING Neither the fabricator nor the BUYERAND w aD [T Li W 1.7 CLOSURE STRIPS ARE FURNISHED FOR APPLICATION, USE CUSTOMER will cut, drill or otherwise alter his work, or the work of other trades, ? rn w z x �.a p INSIDE- Under roof panels panes asave to accommodate other trades, unless such work is clearly specified in the contract Y w C-)On 0 r- rL documents. Whenever such work is specified, the BUYER/END USE CUSTOMER is z u.l w N c-x j OUTSIDE - Between endwall panels and rake trim responsible far furnishing complete Information as to materials, size, location a o r- ¢ " -Under continuous ridge vent skirts and number of alterations prior to preparation of shop drawings. (Section 7 co ^ N co p - Between sidewall panels and save trim AISC Code of Standard Practice, 9th Edition) a ' 1.8 ERECTION & TEMPORARY SUPPORTS: The strength, stability, and safety of this building may be affected by cutting, drilling I�w The erector is responsible to determine, furnish and install all required temporary or removing any components of the building. No such modifications may be made 0 supports and bracing. These temporary supports and bracing shall be sufficient to without the written approval of United Structures of America, Inc. w F secure the building and / or bare structural steel against ]odds likely to be N � CD encountered during erection including those due to wind load and erection operations. Collateral loads or other components provided by others may be supported on this v _j (Section 7.10.3 AISC Code of Standard Practice) I I I j j building in the designated locations if specifically included in the design loads. Unless the connections for such components have been designed and detailed by e• Q 1.9 ERECTION AND UNLOADING NOT BY USA sy w`.;� ,Q(p� �/� U.S.A. the customer is responsible to ensure appropriate connection details are utilized. ,�\� ••.••...,.' !G - ,2,12 WARNING In no case should Aluminized Zinc steel panels be used 0 v 1.10 SHORTAGES�� LI Ce4,:.• �,�� u^'•• in conjunction with lead or copper. Both lead and copper have harmful corrosive effects on the Aluminized Zinc allo coatin when the are Any claims or shortages by buyer must be. made to U.S.A. within five, 5) working days after delivery, or such claims will be considered to have- I 7VO 6...1 % %•In contact with Aluminized Zinc steel panels. Even non -off from copper 54�. :, r' P pP been waived by the customer and disallowed. ;,r : ' 1G °; LTJ -flashing, wiring, or tubing onto Aluminized Zinc should be avoided. 2:1'f ..--SAFETY COMMITMENT UNITED STRUCTURES of AMERICA has a commitment 1.11 CORRECTIONS OF ERRORS AND REPAIRS BMA 6,10) 5;�17, --to manufacture quality building components that can be safely erected. Claims for correction of alleged misfits will be disallowed unless U.S;A i �°' -7:Howe , the safety commitment and job site practices of the erector shall have received prior notice thereof and allowed reasonable inspection . `� ^ `are eyond the control of U.S.A. •'' CT-,, of such misfits. The correction of minor misfits by the use of drik It strongly recommended that safe working conditions and accident ' t pins to draw the components into line, moderate amounts of reaming, n practices be the top priority of any job site. Local, State, chipping and cutting, and the replacement of minor shortages of mat al and Federal safety and health standards should always be followed to help 11j are a normal part of erection and are not subject to claim. No p ensure worker safety. Make certain all employees know the safest and 72 the Building may be returned for alleged misfits without the prior most productive way of erecting a building. Emergency procedures JOB #: 50548 -.� approval of U.S.A. should be known to all employees. APR 1 1 2018 Daily meetings highlighting safety procedures are also recommended. The DRAWN BY: JWW 1.12 ERECTOR NOTE use of hard hats, rubber sole shoes for roof work, proper equipment for Erect steel with piece marks corresponding to location of pies@ marks on handling material, and safety nets where applicable, are recommended. DATE: 4/10/18 erection drawings. Erect and plumb bays progressively to insuf@ overall width Contractors/Erectors should be aware of OSHA regg,ulations for Steel Erection, 29 and length is maintained. The following OSHA Regulations (Standards CFR) are applicable to Steel Erection: OSHA Steel Erection Regulations, Part Number 1926, Subpart "R" CHKD BY: 1.13 ACCESSORIES 2.14 Manufacturer is not responsible for bodily injuries or material damages during unloading, handling, storage, or erection. - DATE' Accessories are not wind rated. IX 1.14 ROOF SYSTEMS 7 � The performance of roof systems supplied by USA is dope 119 installers. USA is ST. LUCI COUon correct and o NT`Y UIL�NG DIVISION proper erection and roof system installation by qualified ro0flAg ' not responsible for non-performance due to improper or defective installation. REVIEWED FOR C IA CE USA does not certify erectors or roofing installers. REVIEWED Y DATE PLANS AND PERMIT T BE KEPT ON 308 SCALE: N.T.S. DESIGN CRITERIA & GENERAL NOTES DWG # MB-0.10 r • p e: • of we • 9' I III I �, e A y R W N AB DIA= BP THK= DETAIL A AB DIA= 1 BP THK= 1 DETAIL G i m ------� Im N \ M N AB DIA= 5/8" AB DIA= 5/8" AB DIA= 3/4 BP THK= 3/8" BP THK= 3/8 BP THK= 3/8" 8_, w SW 8 1 2" --T-- cV 8 1 2" M 4" �D I n I --------I io I 3" --1-- N 2" 2n 8 1 /8'r ol O N -4- C:) N I� W w I DETAIL B DETAIL C DETAIL D STEEL LINE STEEL LINE BBASE ANGLE (RAMSET) STEEL LINE IDTRIM 2 4 `DP01) FIN. FLOOR FIN. FLOOR FIN. FLOOR III a a a a a f SW e. SECTION SECTION "Brr SECTION "C" I I `I 60 AB DIA= 3/4" BP THK= 3/8 -'T-- I x N �I� I ro I DETAIL E 4" 3" WE AN. FLOOR I I I I I a • (IFRRE0 D) SECTION °Dr' SW AB DIA= 1 RP THK= 1 DETAIL F i a U W W 0 Q O wIZD O U O V) U c z Iw- _ z CORPORATE OFFICE 1912 BUSCHONG HOUSTON, TX 77039 281-442-8247 PORTLAND FACILITY 214 FOUNTAINHEAD ROAD PORTLAND, TN 37148 615-325-7351 r- m w � w w m ` r Y L No. 54p10 `••��" � �zwrn ��N C), !. w U LLJ O O U d APR 1 1 2010 ANAN ALMUGHRABI LIC. NO. 54910 EXP. Feb. 2019 UNITED STRUCTURES OF AMERICA 1912 BUSCHONG HOUSTON, TX 77039 JOB #: 50548 DRAWN BY: JWW DATE: 4/10/18 CHKD BY: DATE: SCALE: N.T.S, ANCHOR BOLT DETAILS DWG # MB-1.20 I NOTES FOR REACTIONS 1. ALL LOADING CONDITIONS ARE EXAMINED AND ONLY MAXIMUM/MINIMUM H OR V AND THE CORRESPONDING H OR V ARE REPORTED. 2. POSITIVE REACTIONS ARE AS SHOWN IN THE SKETCH. FOUNDATION LOADS ARE IN OPPOSITE DIRECTIONS. 3. BRACING REACTIONS ARE IN THE PLANE OF THE BRACE WITH THE H POINTING'. AWAY FROM THE BRACED BAY. THE VERTICAL REACTION IS DOWNWARD. 4. BRACING REACTIONS ARE NOT INCLUDED WITH THE MAIN FRAME OR ENDWALL BASIC COLUMN REACTIONS DISPLAYED ON THIS DRAWING. 5. FOR PURPOSES OF FOUNDATION DESIGN AND ANCHOR BOLT / ANCHOR ROD EMBEDMENT, THE BRACING REACTIONS HAVE BEEN INCLUDED WITH THE MAXIMUM REACTIONS DISPLAYED ON THIS DRAWING. 6. MAIN FRAME LONGITUDINAL WIND AND SEISMIC LOAD CASES ARE LISTED AS "LnWIND1", "LnWIND2" AND "SeisLn" RESPECTIVELY. 7. THE METAL BUILDING DESIGN AND ANCHOR ROD SIZING HAVE CONSIDERED BRACING REACTIONS IN COMBINATION WITH OTHER APPLICABLE LOAD CASES. 8. BUILDING REACTIONS ARE BASED ON THE FOLLOWING BUILDING DATA: LENT Tfl((ft): 60 EAVE HEIGHT (ft): 18 / 18 ROOF SLOPE (rise/12): 1.0:12 / 1,0:12 DEAD LOAD: METAL BUILDING STRUCTURE ONLY COLLATERAL LOAD: 3 psf ROOF LIVE LOAD: 20.00 psf FRAME LIVE LOAD: 12 psf ROOF SNOW LOAD: 0 ppsf WIND SPEED: 155 mpph WIND CODE: FBC 17 EXPOSURE: C ENCLOSURE: FULLY ENCLOSED IMPORTANCE WIND: 1.00 IMPORTANCE SEISMIC: 1.00 SEISMIC DESIGN CATEGORY: A SEISMIC COEFF (Fa*Ss): 0.091 9. LOADING CONDITIONS ARE: 1 Dead+ Collateral+Live 2 0.6Deod+0.6Wnd_Leftl 3 0.6Dead+0.6Wnd_Rightl 4 0.6Deod+0.6Wnd_1ong1L 5 0.6Dead+0.6Nnd__ong2L 6 1.01 Deod+1.01 Collateral+0.53Seismic-Right 7 0.6Dead+0.6Wnd_Right2+0.6Wind_Suction 8 Dead+0.6Wind_Pressure+0.6Wnd-Long2L 9 0.6Dead+0.6Wnd_Suction+0.6Wnd-LonglL 10 0.6Dead+0.6Wnd_Pressure+0.6Wnd-LonglL 11 0.6 Dead+0.6 W n d_Leftl+0.6Win d_Suct ion 12 0.6Dead+0.6Wind-Rightl+0.6Wind_Suction 13 0.6Dead+O.6Wnd_Pressure+0.6Wind-Longg2L 14 0.6Dead+0.6Wind-Suction+0.6Wind-Long2L 10. REACTION LOADING CONDITION ABBREVIATIONS ARE: DL = DEAD CL = COLLATERAL LL = LIVE SL = SNOW Drift = SNOW DRIFT Slide = SLIDING SNOW NO = WIND i LEFT (WITH POSITIVE INTERNAL PRESSURE, +GCpi) WR1 = WIND 1 RIGHT WITH POSITIVE INTERNAL PRESSURE, +GCpi) WL2 = WIND 2 LEFT (V NEGATIVE INTERNAL PRESSURE, -GCpi) WR2 = WIND 2 RIGHT (WITH NEGATIVE INTERNAL PRESSURE, -GCpi) LnWINDI = LONGITUDINAL W1 D, CASE 1 LnWIND2 = LONGITUDINAL WIND, CASE 2 WP = WIND PRESSURE WS = WIND SUCTION SeismicL = SEISMIC LEFT SeismicR = SEISMIC RIGHT LnSeismic = LONGITUDINAL SEISMIC LnWINDI-12E = LONGITUDINAL WIND, CASE 1, WIND LEFT EDGE ZONE 2E LnWINDl_R2E = LONGITUDINAL WIND, CASE 1, WIND RIGHT EDGE ZONE 2E LnWIND2_L3E = LONGITUDINAL WIND, CASE 2, MIND LEFT EDGE ZONE 3E LnMND2-R3E = LONGITUDINAL WIND, CASE 2, WIND RIGHT EDGE ZONE 3E E PAT-U * = ENDWALL PATTERN LIVE E#PAT_SL * = ENDWALL PATTERN SNOW E# - ENDWALL NUMBER 1 - LEFT ENDWALL 2 - RIGHT ENDWALL * - AUXILIARY LOAD ID FAT_LL * = RIGID FRAME PATTERN LIVE F AT_SL * = RIGID FRAME PATTERN SNOW F# - RIGID FRAME ID * - AUXILIARY LOAD ID E UNB_SL_L = ENDWALL UNBALANCED SNOW LEFT E NB_SL_R = ENDWALL UNBALANCED SNOW RIGHT F NB_SL_L = RIGID FRAME UNBALANCED SNOW LEFT F NB_SL_R = RIGID FRAME UNBALANCED SNOW RIGHT F#CRANEA* = CRANE LOADING, SINGLE CRANE F# - FRAME NUMBER A* - CRANE LOAD CASE ILDING BRACING REACTIONS t Reactions(k) Panel -Shear -Wall - Col -Wind - -Seismic - (lb/ftl Line Line Harz Vert Harz Vert Wind Ls Note W 1 --- (h) W A 2,3 14.2 11.6 0.3 0.3 W 4 C,D 6.4 5.7 0.1 0.1 W F 3,2 14.2 11.6 0.3 0.3 laid frame at endwall 123 H RIGID FRAME: MAXIMUM REACTIONS Column_Reactions(k ) Frm Col Load Hmax V Load Hmin V Line Line Id H Vmax Id H Vmin 1 F 1 6.2 15.3 2 -6.5 -11.4 1 A 3 6.5 -11.4 1 -6.2 15.3 1 -6.2 15.3 3 6.5 -11.4 RIGID FRAME: MAXIMUM REACTIONS Column-Reactions(k ) Frm Col Load Hmax V Load Hmin V Line Line Id H Vmax Id H Vmin 2* F 1 5.7 11.5 2 -8.8 -13.6 4 -2.2 -18.4 2* A 3 8.8 -13.6 1 -5.7 11.5 1 -5.7 11.5 5 2.2 -18.4 2* Frame lines: 2 3 RIGID FRAME: BASIC COLUMN REACTIONS (k ) Frame Column -----Dead-----Collateral- ----- Live ------ Wihd-Leftl- -Wind-tghtl- --Wind-Left2- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 1 F 2.6 6.3 0.7 1.8 2.9 7.2 -13.4 -25.3 -1.7 -16.7 -12.2 -15.3 1 A -2.6 6.3 -0.7 1.8 -2.9 7.2 1.7 -16.7 13.4 -25.3 0.4 -6.7 2* F 1.1 2.5 0.9 1.8 3.7 7.2 -15.7 -25.3 -4.0 -16.7 -13.5 -15.3 2* A -1.1 2.5 -0.9 1.8 -3.7 7.2 4.0 -16. 15.7 -25.3 1.8 -6.7 Frame Column -Wind-Right2- --Wind_Longl- --Wind-Long2--Seismic_Le': Seismic -Right Line Line Horiz Vert Hartz Vert Horiz Vert Horiz Vert Horiz Vert 1 F -0.4 -6.7 -2.7 -21.7 -3.4 -17.5 -0.1 -O.1 0.1 0.1 1 A 12.2 -15.3 3.4 -17.5 2.7 -21.7 -0.1 0.1 0.1 -0.1 2* F -1.8 -6.7 -4.7 -21.7 -5.4 -17.5 -0.1 -0.1 0.1 0.1 2* A 13.5 -15.3 5.4 -17.5 4.7 -21.7 -0.1 0.1 0.1 -0.1 2* Frame lines: 2 3 ENDWALL COLUMN: BASIC COLUMN REACTIONS (k ) Wind Wind Wind Wind Wind Wind Frm Col ---Dead--- Collat Live Leftl Rightl Left2 Right2 Press Suct Line Line Harz Vert Vert Vert Vert Vert Vert Vert Harz Harz 1 E -1.3 3.7 0.0 0.0 0.0 0.0 0.0 0.0 -9.6 10.6 1 B -1.3 3.7 0.0 0.0 0.0 0.0 0.0 0.0 -9.6 10.6 4 A 0.0 0.6 0.3 1.8 -4.7 -3.1 -2.9 -1.4 -3.4 3.9 4. C 0.0 1.3 0.7 4.7 -12.7 -7.1 -9.1 -3.5 -7.1 7.8 4 D 0.0 1.3 0.7 4.7 -7.1 -12.7 -3.5 -9.1 -7.1 7.8 4 F 0'0 0.6 0.3 1.8 -3.1 -4.7 -1.4 -2.9 -3.4 3.9 Seis Frm Col Right Line Line Vert 1 E 0.0 1 B 0.0 4 A 0.0 4 C 0.0 4 D 0.0 4 F 0.0 ENDWALL COLUMN: MAXIMUM REACTIONS Column-Reactions(k ) Frm Col Load Hmax V Load Hmin V Line Line Id H Vmax Id H Vmin 1 E 7 5.9 2.2 8 -6.5 3.7 6 -1.4 3.7 1 B 7 5.9 2.2 8 -6.5 3.7 6 -1.4 3.7 4 A 9 2.3 -2.0 10 -2.0 -2.6 1 0.0 2.6 9 2.3 -2.6 4 C 11 4.7 -10.3 10 -4.2 -6.4 1 0.0 6.7 11 4.7 -10.3 4 D 12 4.7 -10.3 13 -4.2 -6.4 1 0.0 6.7 12 4.7 -10.3 4 F 14 2.3. -2.6 13 -2.0 -2.6 1 0.0 2.6 14 2.3 -2.6 LINE Wind Wind Seis ,��'t1j111w///7�,FJ Longl Long2 Left Vert Vert Vert 0.0 0.0 0.0 w 0.0 0.0 0.0 -4.9 -2.8 0.0 fJa.5ti910 -12.5 -7.5 0.0 -7.5 -12.5 0.0 -2.8 -4.9 0.0 /aAPRvN 2018 ANAN ALMUGHRABI LIC. NO. 54910 EXP. Feb. 2019 UNITED STRUCTURES OF AMERICA 1912 BUSCHONG HOUSTON. TX 77039 U W W W Q� W Q O to IY W CD U O C7 U CZ) Z W z CORPORATE OFFICE 1912 BUSCHONG HOUSTON, TX 77039 281-442-8247 PORTLAND FACILITY 214 FOUNTAINHEAD ROAD PORTLAND, TN 37148 615-325-7351 r m w z N w J r H U m 7 = O JMJ C7 U w = M Y I m ¢ J w Cn tz w O U � U cif 0- JOB #: 50548 DRAWN BY: JWW DATE: 4/10/18 CHKD BY: DATE: SCALE: N.T.S. ANCHOR BOLT REACTIONS 9' A DWG # MB-1.30 SPECIAL BOLTS O DOWNSPOUT LaOATIONS ROOF PLANo ID QUAN TYPE DIA LENGTH WASH C) cg 1 3 A307 1 2 l 1 4 0 w 2 4 A307 1 2" 1" 0 CONNECTION PLATES o ROOF PLAN ❑ ID MARK PART � 1 CL23A MEMBER TABLE ~ ROOF PLAN MARK PART CD P-1 8Z14 N c) P-2 8Z16 0 1 60'-0" OUT —TO —OUT OF STEEL 4 1 60'-0" OUT —TO —OUT OF STEEL 4 P- 3 8Z14 w z z 2 3 P-5 8Z12P ZD 20'-0" 20'-0" 20'-0" E-1 BES16 E-2 8ES16 CORPORATE OFFICE E-3 8ES16 1912 BUSCHONG i'-2° PURLIN P—t' Y—t" CB-3 6_CBL HOUSTON, TX 77039 LAP t'—Y r-r CB-4 6_CBL 281-442-8247 CB-5 4_CBL PORTLAND FACILITY SP-1 L2X2X16 214 FOUNTAINHEAD ROAD O SZ1 SZ1 PORTLAND, TN 37148 RF1-1 E-1 RF2-1 E-1 RF2-1 E-3 TRIM TABLE 615-325-7351 F F F ROOF PLAN m E -8 OID MARK E EC-1 1 PBR PK F O N P-1 T I P-3 T N RF1-2 RF2-2 ;ER-2 A ONwL0F�co-J I• ,p "oo ao co o� co ro N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N O DOWNSPOUT LOCATIONS -TO-OUT OF STEEL —2 GIRT LAPS i in 10 G-14 C-15 G-16 G-14 \ - 5/ G-16 G-14 / G-15\ G-16 SA1 ----------------------------------- - I I I H RF1-4 RF2-1 RF2-1 EC-5 SIDEWALL ELEVATION: FRAME LINE ;A E-3 q>\ F-1 D\ E-1 G-19 G-15 G-22 G-18 \ 3- � G-22 I / G-17 N N G-2G •ti G-15 G-16 I / SA1 \ H 0 E I I I EC-8 R172-1 RF2-1 RF1-1 8'-4" '-4" "-4 SIDEWALL ELEVATION: FRAME LINE F I I I I I I I I 0 0 0 f 0 0 0 0 0 ❑ I ❑ F ❑ O I O I O I O I O I O I O I O I O I O I O I O I O I O I O I O I O I O I O I O I 0p W ap 00 OD 0p O] W aD KJ N m W a0 a0 a€1 N N � 00 SIDEWALL SHEETING & TRIM: FRAME LINE A PANELS: 26 Ga. MBCI PBR — COLOR T.B.D. UNICOTE 2000 O O I O I O I O I O O I O I O I O O O I O O I C] I d I O O O T O OD W a0 W o0 W co. a0 W W W a0 Tb W a0 tl7 co W o0 a0 11 > I Ilo I'D I I SIDEWALL SHEETING & TRIM: FRAME LINE F PANELS: 26 Go. MBCI PER — COLOR T.B.D. UNICOTE 2000 2 EG20 TRIM-16 3 ET02 4 EC20L TRIM-20 5 CG20L TRIM-4 6 RT20L 7 EG20R TRIM-21 8 CO20R 9 RT20R 10 DJ01 TRIM_31 U W M W W ¢ O N w o v� �CD N U RAME LINE A & F CORPORATE OFFICE 1912 BUSCHONG HOUSTON, TX 77039 281-442-8247 HID 1 MARK/PART 1 CL23A MEMBER TABLE FRAME LINE A & F pORTLAND FACILITY 214 FOUNTAINHEAD ROAD PORTLAND, TN 37148 MARK PART DJ-2 8X25C16 DH-2 8X25C16 615-325-7351 E -1 8ES16 E -2 8ES16 E-3 8ES16 G-14 8Z16 a o G-15 8Z15 G-16 8Z15 G-17 8Z16 G-18 8Z13 G-19 8Z15 0 G-20 8Z16 a G-21 8Z14 G-22 8Z16 W no 1 o not o ANAN ALMUGHRABI LIC. NO. 54910 EXP. Feb. 2019 UNITED STRUCTURES OF AMERICA 1912 BUSCHONG HOUSTON, TX T7039 F- U w 0 of a JOB #: 50548 DRAWN BY: JWW DATE: 4/10/18 CHKD BY: DATE: SCALE: N.T.S. SIDEWALL ELEVATIONS DWG # MB-4.10 Q1" Q1• 12 C� 1" 12 m SAI—m —_ m___ ---- m--- —SA1 IT 'iG-1 II 1 II 1 I I IG_t ---HB-1----—HB-2----—HU-2------HB-1--� I I I � 1 l 1 � Q 111 I II 1 II G 111 II 11 1 U I ---------- ------- - - I II I I I I EC-1 EC-2 EC-3 EC-2 EC-4 4" 66 -- 50'-6„ 11411 ENDWALL ELEVATION: FRAME LINE 1 Q1° EC-5 EC-6 EC-7 EC-8 [4'-0" 12'-0" 4'-0" y I ENDWALL SHEETING & TRIM: FRAME LINE 1 PANELS: 26 Go. MBCI PBR — COLOR T.B.D. UNICOTE 2000 DOOR SHEETING & TRIM: FRAME LINE 1 PANELS: 26 Go. MBCI PBR — COLOR T.B.D. UNICOTE 2000 12 12 ENDWALL ELEVATION: FRAME LINE 4 I I I N N N N N \ \ \ � ^ of T ^ I o O 00 00 N 00 01 O) O� O1 N N \I I ENDWALL SHEETING & TRIM: FRAME LINE 4 PANELS: 26 Ga. MBCI PBR — COLOR T.B.D. UNICOTE 2000 0 BOLT TABLE AT COL LINE 1 & 4 BOLTS TO BE PRETENSIONED U.N. BOLT WASHER LOCATION QTY TYPE DIA LENGTH QTY ER-1/ER-2 8 A325 5/8" 2" Columns/Raf 2 A325 1/2" 1 1/4" Columns/Raf 4 A325 1/2" 1 1/4" Back Braces 1 A325 3/4" 1 1/2" ENDWALL FLANGE BRACE TABLE COL LINE 1 & 4 AID SIDES MARK SIZEBER OFFSET FB2A L2X2X12 2'-2" 12 2 1 F131A L2X2X12 2'-2" 2 LT01 3 DPO1 4 DJ01 5 DH01 6 CT01 7 RT20 HB-2 BB-1 BB-2 EC-1 EC-2 EC-3 EC-4 EC-5 1„ EC-6 12 EC-7 EC-8 ER-1 ER-2 DJ-1 DH-1 G-1 G-2 G-3 O G-4 G-5 G-6 G-7 G-8 G-9 G-10 G-11 G-12 G-13 TRIM-31 TRIM-33 TRIM-26 TRIM-12 C8x11.5 P0450188 P0450188 W10X33 W8X18 W8X18 W10X33 W8X10 W8X13 W8X13 W8X10 W14X22 W14X22 8X4C14 8X25C16 8Z16 8Z16 8Z16 8Z16 8Z16 8Z16 8Z16 8Z16 8Z16 8Z14 8Z16 8Z13 8Z16 ANAN ALMUGHRABI LIC. NO. 54910 EXP. Feb. 2019 UNITED STRUCTURES OF AMERICA 1912 BUSCHONG HOUSTON, TX 77039 Z CORPORATE OFFICE 1912 BUSCHONG HOUSTON, TX 77039 281-442-8247 PORTLAND FACILITY 214 FOUNTAINHEAD ROAD PORTLAND, TN 37148 615-325-7351 m i w Z w ZD < rn H r m M = M w Ln ° z L,J Y W' N1 m Q J U w F W CD w I- cn o U 11 JOB #: 50548 DRAWN BY: JWW DATE: 4/10/18 CHKD BY: DATE: ISCALE: N.T.S. I ENDWALL ELEVATIONS DWG # MB-4.30 BOLTS AND SPLICE PLATE TABLE BOLTS TO BE PRETEINSIONED U.N. SPLICE QTY WASHER MARK TOP/BOT/INN TYPE DIA LENGTH QTY WIDTH THICK LENGTH SP- 1 4 4 ® A325 3/4" 2 1/4p 8" 1/2 2;-1 3 SP- 2 4 4 0 A325 3 4 2 1/4' 6" 1 2 2'-1 1 FLANGE BRACE TABLE FRAME LINE 1 AX2X12 BER OFFSET 17 ID SIDES MARK E (REF G2 & H2 1 1 F64A 2'-2" STFFENER TABLE Mark Stiff Mark Plate Size Width Thick Length RF1-1 RF1-4 St- 1 St- 1 4" 1/4" 14" 4" 1/4" 14" BASE PLATE TABLE Col Plate Size Mark VI Thick Length BP-1 8" 3/8" 1'-3 1/2" BUILDING CROSS SECTION: FRAME LINE 1 Mark Weight Length %ortc nd Thick Len th W�x Thk x Len th W'x ThkVxyLength RF1-1 566 17 -4 1 2 14.0 14.0 0.188 15 -7 3797 8 x 3 8 x 17 -3 7 8 8 x 3/8 x 15 -7 3/8" 14.0 14.0 0.250 1'-9 11/16" 6 x 1/4" x 1'-10 9 16" RF1-2 859 28'-2 3/1 ' x 8'-1 1 8" 6 x 3/8" x 8'-2 5/8" 18.0/18.0 0.188 20'-0" 6 x 3/8" x 20'-0' 6 x 1 /2 x 19 -10 1 /2" RF1-3 859 28'-2 3/1 "18.0/18'0 0.188 20'-0" 6 x 3/8 x 20'-0 6 x 1/2 x 19 -10 7//16 18.0/18.0 0.188 8'-2 11/16" 6 x 1/4" x 8'-1 1/8" 6 x 3/8 x 8 2 5 8" RF1-4 566 17'-4 1/2" 14.0/14.0 0.250 1-1 1 ,9 11�16" 6 x 1/4" x 1_ 10 9�16 8 x 3/8 x 15'-7 3/8" APR 1 1 2018 ANAN ALMUGHRABI F . NO.54910 , Feb. 2019 ITED STRUCTURES OF AMERICA 1912 BUSCHONG HOUSTON, Tx 77039 o w O Q wo � n- U � O N U nz LLJ _ z CORPORATE OFFICE 1912 BUSCHONG HOUSTON, TX 77039 281-442-8247 PORTLAND FACILITY 214 FOUNTAINHEAD ROAD PORTLAND, TN 37148 615-325-7351 m m m w '- a o o � w z N J W W 00 m M rr3 N ONj O CJ W Y w m¢ J J W d I J O I- 00 N Cn Op N a:: W H CD U O wo � K U d JOB #: 50548 DRAWN BY: JWW DATE: 4/10/18 CHKD BY: DATE: SCALE: N.T.S. CROSS SECTION DWG # MB-7.10 BOLTS AND SPLICE PLATE TABLE BOLTS TO BE PRETENSIONED U.N. SPLICE QTY WASHER MARK TOP/BOT INT TYPE DIA LENGTH QTY WIDTH THICK LENGTH SP— 1 4 4 2 A325 3/4" 2 1/4" 8" 1/2" 2'-7 3/8" Sp_ 2 4 4 0 A325 3 4" 2 1/4" 6" 1 2 1 —9 1/4 FLANGE BRACE TABLE FRAME LINE 2 3 MEMBER OFFSET DID SIDES MARK SIZE (REF G2 & H2) 1 1 FBSA L2X2X12 2'-2" 2 1 FB3A L2X2X12 2'-2" STIFFENER TABLE Mark Stiff Mark Plate Size Width Thick Length RF2-1 St— 1 4" 1/4" 14" BASE PLATE TABLE Col Plate Size Mark Width Thick Length BP-1 8" 3/8" 1'-3 1/2" IIIIIII-JU111111= MCMUM IAOLL 1 Mark Weight Length RF2-1 544 17 47 2 RF2-2 589 28'-2 3/1 " RF2-3 589 _w _� -----�---- — — — — ---- - -- --- �--_�__� 4.0 0.250 2'-311 4.0 0.188 8'-31! 4.0 0.135 20'-0" 4.0 0.135 20'-0" i'-2 11 /16" 190161:I4I19111111I110 BUILDING CROSS SECTION: FRAME LINE 2 3 1'-2 11 /16" 2 Zs x )/a x I 7/u 6 x 1/4" x 1'-10 9/16 6 x 1/4" x 28'-1 1/8" 6 x 1/4" x 28'-1 1/8" ?f X 0/115 x 15-1 J/d 6 x 1/4" x 6'-3 5/8. 6 x 1/4" x 19'-10 13/16" 6 x 1/4" x 19'-10 13/16" I � I � I I I 1 I i!IIill;. I � . I 1 r " , ,10 A- S Taif i 1 AFF% I 1 LU10 ANAN ALMUGHRABI LIC. NO. 54910 EXP. Feb. 2019 UNITED STRUCTURES OF AMERICA 1912 BUSCHONG HOUSTON, TX 77039 I O w Q W O d rJ � O O O Z w z CORPORATE OFFICE 1912 BUSCHONG HOUSTON, TX 77039 281-442-8247 PORTLAND FACILITY 214 FOUNTAINHEAD ROAD PORTLAND, TN 37148 615-325-7351 r m J N � yy,� N T ♦- a] M } J = Mro W J N W n 2 w Y W m< J U U L'J N ^ d d= w CD LLJ N O C U d JOB #: 50548 DRAWN BY: JWW DATE: 4/10/18 CHKD BY: DATE: SCALE: N.T.S. CROSS SECTION DWG # MB-7.11 a A 1 Ln c 1 60'-0" OUT -TO -OUT OF STEEL 1 2 20'-0" 20'-0" 1'-2" 18'-10" RAKE ANGLE PURLIN (BEYOND) ------F ----7 I —_------------- -------7 ------------ L_ _______________J L---------------- — --_J M.F. RAFTER M.F, RAFTER BRACKET / ` (1) 3/4" x 2" / A325'S W/ WASHERS END PIPE STRUT STUB COLUMN (BB -) / - > WALL GIRT (2) 5/8" x 1 3/4" / A325'S W/ WASHERS PBR WALL PANEL— IC USE BOLT FOR ERECTION WELD AFTER FINAL ASSEMBLY 3/16" ni in MEMBER SCREWS W ir_ tly r HEADER 3/16" USE WELDBAFTERFINAL ASOLT FOR SSEMBLY ON JAMB TRIM (DJ01) USE BOLTS FOR ERECTION WELD AFTER FINAL ASSEMBLY J U I 0 Ln A STUB COLUMN ;; ;; (2) 5/8" x 1 3/4" PBR WALL PANEL A325'S W/ WASHERS INSIDE CLOSURE In Ilu MEMBER SCREWS i11 IF-= DRIP TRIM (DP01) �— HFAIIFR 5%"(1) PANEL CAP TRIM (LT01) MEMBER SCREWS OUTSIDE CLOSURE WEATHER PROd�FING (NOT BY USA) STRUCTURAL ANGLE � III II MEMBER SCREWS POWERLIFT HYDRAULIC DOOR COMPONENTS PBR DOOR PANEL (NOT BY USA) TRIM DETAIL AT JAMB COLUMN POWERLIFT HYDRAULIC DOOR COMPONENTS (NOT BY USA) I I I I I I I I I ——I— TRIM DETAIL AT DOOR HEADER PBR DOOR PANEL MEMBER SCREWS POWERLIFT HYDRAULIC INSIDE CLOSURE DOOR COMPONENTS (NOT BY USA) PANEL CAP TRIM j (LT01) I I r BOTTOM DOOR TRUSS 41,E"(f) L c II I (NOT BY USA) TRIM DETAIL AT BASE OF DOOR No.54940 ie STATY OF t APR 1 1 268 ANAN ALMUGHRABI LIC. NO. 54910 EXP. Feb. 2019 UNITED STRUCTURES OF AMERICA 1912 BUSCHONG HOUSTON, TX 77039 a U �o w w �Q 0 Ln oo� w � w U Of o to �z Z CORPORATE OFFICE 1912 BUSCHONG HOUSTON, TX 77039 281-442-8247 PORTLAND FACILITY 214 FOUNTAINHEAD ROAD PORTLAND, TN 37148 615-325-7351 r �m W Lv W e0 = M Nj Li (n IJi C7 U W Z M Y 1 m Q J U Z W 0 W m a t N J p— N N K 0 Ln U O a JOB #: 50548 DRAWN BY: JWW DATE: 4/10/18 CHKD BY: DATE: ISCALE: N.T.S. SECTIONS/DETAILS DWG # MB-8.10 r U.S.A Only Provides the Roof Purlin. Field Modifications All Other MotgFiai and Hardware is By Others - WARNING - ROOF STEEL LINE ROOF STEEL LINE Ref. Cover Sheet Li Paragraph 2.11 1 —2 8° ZEE STRUT Li r l PURLIN MEMBER AS NOTED PURLIN 4 SA3 :2Purlin Q (BY USA) SCREW (FIELD ATTACH) STRUT PURLIN 8 1/2" � o (2) Screws #12 x 1 1/4" SDS PURLIN -CLAMP EAVE STRUT or or #14 x3/4" STS • • o o . . o o � O Flange C-Clamp is not -_-_ • • o o • • o Clip Angle, Bolts, a Hanger, ETC... Purlin n acceptable connection -------- - -------- --- - SHEETING ________ __ _ _ I I I � � By Others r (BY USA) I BOLT SHEETING ANGLE FLANGE BRACE I I MEMBER SCREWS � o 3/4" PURLIN Connection through the ANGLE � o' (4) 1/2"xl"A307 IF REQD (PLAIN) ca MAX lan e is not acceptable table g P 1 2' x 0 -1 A307s FLANGE BRACE MACH BOLTS o w z 1/4" Eye Lag Driller _ (By Others) END RAFTER„ o Recommended Connection Details ALL -THREAD ROD ( „CEE OR WF) MEMBER SCREWS MEMBER SCREWS (PLAIN) 3 4" Connection through the MAIN FRAME (PLAIN) CORPORATE OFFICE MAX flange is not acceptable RAFTER HOUSTON, TX 777039 A7 SECTION THRU ENDWALL RAFTER 281-442-8247 POUNTAI FACILITY Drilling Boles in flanges of purlins is structurally detrimental to the member. Any collateral loads which are included in the Purlin A10 ROOF PURLIN TO ANGLE LOW EAVE STRUT PURLIN CONNECTION design to be attached by connection to web or to flange as shown using 1/4" eye lag driller. 25# MAX load ea. attachment. ENDWALL 1 214 FOOUNTAINHEAD ROAD PORTLAND, TN 37148 615-325-7351 EAVE STRUT PURLIN 1/2"xt" A307 MACH BOLT m �s BFRAFTER-____------------ _ _ 10 _ 01 (TYP UNL NTD) ENDWALL JAMB COLUMN -------- EW RAF I I' ENDWALL GIRT o FLANGE BRACE JAMB WRAP Q (8) 1/2" X 1" A307 BOLT I 0I (REF ELEV FOR LOC) (TYP ® GIRT CONN) o o „A, I O " ° ° ERA1 o ENDWALL COLUMN Z 4) 5/8" DIA. x 1 3/4" A325 3/4"� x l 3/4" (NS/FS) ° ° o' z a A325 BOLTS J v ENDWALL COLUMN i� WIDE FLANGE EW col. ¢ w CL - Cn COLUMN V (4) ERAi EW RAF I o ENDWALL GIRTS 1 j -20" ON CENTER (TYP.) SCREWS „ „ � 1/2 x1 FLAT HEAD BOLT 1,-O„ I I 1 10 OI ' (4) 1/2" x 1" A307 BOLTS w 1 ENDWALL GIRT ENDWALL GIRT 't— END RAFTER sEcnoN "a" 1,-2 C15 ENDWALL 'WF' JAMB COLUMN TO GIRT B6 HOT ROLLED RAFTER TO HOT ROLLED CORNER COLUMN ENDWALL COLUMN TO RAFTER S C12 O ENDWALL COLUMN TO WALL GIRT C6 HOT ROLLED ENDWALL COLUMN Z SIDEWALL GIRT w of N O� CRIGID FRAME ORNER COLUMN J SIDEWALL CORNER COLUMN RIGID FRAME COLUMN 1" \t\�y`Z� ``' dt ' r a �" N J 6-0 z M z M GIRT EAKY PURRUN :' N �_: c 10 C w U o STEEL =_----- �... K (4) 1/2" x 1" A307 BOLTS 0 p LINE^' t ; c ._ �.,. -_ c~i) m n > °r a ENDWALL GIRT O O i O O O ENDWALL LLJ CD --- GIRT (8) 5/8"DIA.x 2- A325 ZD of FIELD BLOCK i in 0 W/ HARDENED WASHERS GIRTS r_____ -- REQUIRED iO O ENDWALL E-rr1/2" x 1" A307 BOLTS (TYP.) O ° O O FOR LAP GIRT " 0 0 y _____________ _________ APR 1 1 2010 O O CL6 CL13 ANAN ALMUGHRABI I FIELD BLOCK GIRT F� 2 RAFTER SPLICE LIC. NO. 54910 EXP. Feb. 2019 4 1/2" x 1" A307 BOLTS O / " D12 CORNER COLUMN TO WALL GIRT 1 STEEL LINE D27 CORNER COLUMN TO ENDWALL GIRT AT SURFACE CHANGE UNITED STRUCTURES OF AMERICA 1912 BUSCHONG HOUSTON, TX 77039 D16 CORNER DETAIL AT RF COLUMN (ALL BOLTS SHOWN ARE 1/2" DIA. x 1" A307'S) JOB #: 50548 DRAWN BY: JWW DATE: 4/10/18 CHKD BY: DATE: SCALE: N.T.S. DETAIL DRAWINGS DWG # MB-9.10 ca A r, Im 9 77777, • • • 9 • • • • a. ERECTOR CONNECTION NOTE: WHEN YOU HAVE A BY-PASS CONDITION WHERE GIRTS SHARE A COMMON CONNECTION, YOU MUST FIRST USE A FLAT HEAD BOLT REF ROOF TO ATTACH ONE GIRT TO THE CLIP. ROUND HEAD BOLTS CANNOT BE USED IN THIS CONDITION, IT MUST BE A FLAT FRAMING LAYOUT BOLT IN ORDER TO BE FLUSH. THIS WILL ALLOW HANDLING OF ONE GIRT TO MAKE THE FINAL LAP. THE REMAINING (8) 1 /2% 0 —1 OFFSET CONNECTION BOLTS ARE THE STANDARD A307 MACHINE BOLTS. A307 BOLTS (TYP) 1/Yx 1' A307 MACH BOLT GF (TYP UNL NTD) PURLIN FRA E OFFSET ADDITIONAL FLAT BRACE (IF REDD REF: CROSS SE( R ANI RRACF— "1b ffO ADDITIONAL FLANGE—/ ' FLANGE BRACE BRACE (IF READ) I jo W/ (2) 1/2"x0'-1 REF CROSS SECTION A307 BOLTS (TYP) G2 ROOF PURLIN TO INTERIOR FRAME RAFTER J24 EAVE STRUT STEEL LINE (- (2) 1/2" x 1 1/4" SECTION ELEVATION EAVE STRUT TO BY-PASS RIGID FRAME HILLSIDE WASHER FLAT WASHER HEX NUT EYE BOLT WEB OF FRAME CABLE BRACE Q2 CABLE BRACE TO FRAME DETAIL (A - HtW) - - MAIN FRAME INTERIOR COLUMN (ONE) FLATHEAD BOLT PER CONN I SIDEWAH SIDEWALL BAY DIMENSION INT FRAME GIRT STEEL LINE(7) 1I2' A307 BOLTS & (ONE) 1 2' FLATHEAD A307 BOLT INT FRAME FLANGE (ONE) 1/2`x 1'� FLAT HEAD A70 BOLT K3 C O a a O 0 GIRT LAP AS REDD H2 GIRT TO MAIN FRAME COLUMN InN ' 'n "A 7n7 MACH BOLTS ;IRT WALL GIRT TO DOOR JAMB Q12 BACK BRACE TO STUB COLUMN EAVE STRUT GABLE RAKE ANGLE 112 S.D. SCREW REFERENCE ROOF FRAMING PLAN FOR CONNECTION DETAILS. ENDWALL 8 EAVE STRUT TO ENDWALL RAFTER '"'"" GIRT SECTION ELEVATION GDOOR JAMB TO WALL GIRT" ELDED FTER CUP 'ID FRAME RAFTER Q31 BRACE TO RIGID FRAME RAFTER (2) 1/2" x 1 1 /4" A307 BOLTS SIDEWALL STEEL LIN EAVE STRUT FRAME E GIRT DEPTH J2 EAVE STRUT TO RIGID FRAME 900R J""0 CONNE PLATE HEADEI. SECTION ELEVATION DOOR HEADER TO DOOR JAMB (ALL BOLTS ARE 1/2" x 1") Rigid Frame Rafter Welded Clip Endwall Bid Bolted Clip (CL13) S SECTION OF ENDWALL GIRT TO RAFTER (ALL BOLTS SHOWN ARE 1/2" x 1" A307) CL23A (8) 1/2" 1 1 /4" f, EAVE STRUTS x BOLTS FRAME COLUMN FIELD DRILL 9/16" DIA. HOLES FOR CL23A COONNECTION!! SECTION ELEVATION CL23A J4 EAVE STRUT TO BY-PASS RIGID FRAME (W/ CL23A) DOOR JAMB CONNECTION PLATE O DOOR HEADER 0 1 SECTION ELEVATION M13 DOOR HEADER TO DOOR JAMB Q CJ tY w Q Q Lil U � �o c U c� Z w z— CORPORATE OFFICE 1912 BUSCHONG HOUSTON, TX 77039 281-442-8247 PORTLAND FACILITY 214 FOUNTAINHEAD ROAD PORTLAND, TN 37148 615-325-7351 8 w a 0 z 0 F a 0 cn W Z W W m i,'J N cD O r U CL1 Q d 540 !Q W 1_ CD c� a ANAN ALMUGHRABI LIC. NO. 54910 EXP. Feb. 2019 UNITED STRUCTURES OF AMERICA 1912 BUSCHONG HOUSTON, TX 77039 JOB #: 50548 DRAWN BY: JWW DATE: 4/10/18 CHKD BY: DATE: SCALE: N.T.S. DETAIL DRAWINGS DWG # MB-9.11 0 Y:. IL MEMBER SCREW LOCATION Detail 'A" (ALL MEMBERS EXCEPT AS NOTED) 12" 1 12" 1 12" 9b" 7" 2' 212" 7" 217" 21T" 7" 212" MEMBER SCREW LOCATION Detail 'A" PEAK PURLIN. EAVE STRUT, AND PANEL END LAPPPS Stitch Screws At ontinuous Tape Sealer 20' On Center 3ex'a4 (Standard) 1"x's (Optionol) ztended Leg On PBR" Panel DETAIL "A" Member Screws , Roof Continuous Tape Sealer 18"x 1 ! (Standard) 1"x'A (Optional Purlin (Must Be Specified On Order SECTION THRU PEAK PURLIN AND PANEL END LAPS "PBR" PANEL ROOF I I uhLIL . _ Tsai NOTE! —I — CREW PATTERNS SHOWN, SATISFY UL-90 EQUIREMENTS FOR ROOF. HE USA PBR MUST NOT BE ATTACHED TO THE STRUT ZEE. ANY ADDED z001` PURLINS FOR EDGE TRIPPING REQUIREMENTS MUST BE ATTACHED TO THAT MEMBER. 12" 12" 12" 10" 2" . 10" 2" , 10" 12 , MEMBER SCREW LOCATION h � ALL MEMBERS Detail '" (2) Screws Between Base 1' Member And 7'-312" Girt. (1) Screw Between All Other Members. And (1) Screw At All Member Locations. Stitch Screws DETAIL "B" Strip away 2' of ,insulation. Fold back the vinyl facing. Tuck over insulation in the recesswoola, prevent ing. "PBR" PANEL WALL Recommended Base Detail to revent Edge Creep Damage ROOF PANEL 2" GUTTER SHOWN, RAKE TRIM SIM. TRIM TRIM LAPS 4 ROOF PANEL GUT GUTTER END CAP GUTTER x Attach to Eave Strut with Gutter Strap (SGO1) Pop Rivets ® 3'-0" O/C ® 4'-0" a/c Roof Steel Line Stitch Screw Rake Trim Stitch Screws 2 3/4° for Strap / (RT20) Stitch Scr6ws ® 12" O/C rw/ 06 O/C Inside Closure continuous Tape Pop +I Sealant under Trim Member Rivet — Roof Panel Screws _ _ Panel Cap Trim Member Screw Roof Panel (ET02) * .� 0 6" O/C Outside Closure Member Screws Sheeting Angle 0 12" O/C Stitch Screws 0 12" O/C Gutter (EG20) Outside Closure Purlin Pop Rivets (Beyond) 0 12' O/C Eave Strut Wall Panel Wall Panel TRIM RAKE TRIM DETAIL TRIM LOW EAVE DETAIL 12 SHEETED WALL 16 GUTTER TRIM WITH SHEETED WALL ` RAKE TRIM POP RIVET AND CAULK (FIELD MITER GUTTER AND RAKE ENDS) TRIM EAVE TO RAKE TRANSITION 20 TYPICAL GUTTER Caulk And Pop Rivet GUTT TRIM 21 Field Cut Gutter Gutter I W/ "X" Pattern Downspr Strap I Strap Field Bend "A" SECTION A Pop Ri Gutter Tabs Pop Rivet Into Downspout Downspout Pop Rivets Pop Rivets 01 Downspout Downspout Downspout Strap Downspout Strap "R" PANEL WALL "A" PANEL WALL TRIM DOWNSPOUT TO GUTTER 29 DOWNSPOUT STRAP ATTACHMENT Downspi EAVE TO RAKE TRANSITION TYPICAL GUTTER Panel dice Req'd) (Install w/ 2 Pop Rivets on 3 Sides) TRIM DOWNSPOUT DETAIL 30 SHEETED WALL [R IBS STITCH SCREWS 0 20" O/C D.S. STRAP QUANTITY AVE HEIGHT QUANTIT 1O'-0 2 12'-0 2 14'-0 2 16'-0 2 20'-0 2 25'-0 3 i I I I I STEEL LINE ------------------------------- PBR PANEL ~— CORNER TRIM (CT01) U � 9 w M LL� w O w O F— U � I— O N U Cz L _ z CORPORATE OFFICE 1912 BUSCHONG HOUSTON, TX 77039 281-442-8247 PORTLAND FACILITY 214 FOUNTAINHEAD ROAD PORTLAND, IN 37148 615-325-7351 r m 0 U 0 TRIM OUTSIDE CORNER DETAIL Z 26 PBR WALL PANEL V) of N M 111„Iil;i' v � ca mM J 61 ap C2CY 7 W Uj YU no c~i1Z�� W g U 0 0 U a ANAN ALMUGHLERICA UC. No. 54s EXP. Feb. 20 UNITED STRUCTURES Of 1912 BUSCHONG HOUSTON, TX 77039 JOB #: 50548 DRAWN BY: JWW DATE: 4/10/18 CHKD BY: DATE: SCALE: N.T.S. DETAIL DRAWINGS DWG # MB-9.12 7 Pop Rivets At Jamb 12" On Center\ ---------------- \ Wall Panel Jamb Trim ( "R" Panel ) (MK—DJ01) TRIM_31 - JAMB TRIM DETAIL Wall Panel Member Screws At 12" On Center Head Trim (MK—DH01) Pop Rivets At 12" On Center Header TRIM 33 - HEADER TRIM DETAIL MEMBER SCREWS (SHORT, MEDIUM, OR LONG) #12 X 2" SDS W/ WASHER #12 X 1 1/2" SOS W/ WASHER I 2X11 4„SDS # / W/ WASHER SCREW 4 STITCH *W� #14 X 7/8" LAP-TEK W/ WASHER FASTENERS SELF DRILLING APR 1 1 2018 ANAN ALMUGHRABI LIC. NO. 54910 EXP. Feb. 2019 UNITED STRUCTURES OF AMERICA 1912 BUSCHONG HOUSTON, TX 77039 V ct� o o- �o V) � z z- CORPORATE OFFICE 1912 BUSCHONG HOUSTON, TX 77039 281-442-8247 PORTLAND FACILITY 214 FOUNTAINHEAD ROAD PORTLAND, TN 37148 615-325-7351 m w a 0 JOB #: 50548 DRAWN BY: JWW DATE: 4/10/18 CHKD BY: DATE: SCALE: N.T.S. DETAIL DRAWINGS DWG # M13-9.13