2015 INTERNATIONAL
Plan Review # 1807-0362
a RESIDENTIAL CODE® 1i19i2018
. Date:
FOR ONE- AND TWO-FAMILY DWELLINGS Valuation:
Md PLAN REVIEW RECORD Fee:
JURISDICTION:
(City, County, Township, etc.)
I�
BUILDING LOCATION ` 8617 COBBLESTONE DR ._
a
> , ' (Stre et address)
BUILDING.DESCRIPTIO.N h ;SFR_
�r
EVIEW.E0. BY - JWF° ,.
umerahs indicated in,parerithesis are""applic ble code sections of the 2l)157ntemational Residential Code(IRC), The plan review accomplished as�indicated-.�a.
r. � this record �s limded fo those code sections specfically identified herein: This recored references commonly applicable code`sections with dueyregard for,".._
e amount type of detailed Information vihich is typically fourid;on construction documents for one -and two family dwellings and townhouses. It does :=;
of reference all`cotle provisions which may be applicable to specific buildings This're"cord is`desigried to be used oniy`by those who'are knowledgeable
Fy and capable`of exercising'° cmnpdtentiuddmentiin evaiiieting construction°documenfs for code compliance.'.
CORRECTIONS LIST
llN0.
Code
DESCRIPTION
Section
�I
f
II
I
,I
I
S
i
,I
Y�
Copyright,1 • o • Rep •• • by prohibited. ISBN 978-1-60983-611-5
is the trademark• _ • ••_ • and, is-re'gistefed in theU.S. Ratent and II III II'IIII III III III III
Trademark • .•o,•
-,®,- .
9II781609II836115II
I•E• ALtbU'N'CIL, INC.
COD�;COUNCIL' •
-1-
Entries to this Plan Review Record that require a field check or inspection of the installation must be coordinated with the inspection phase (R109) of the project.
BUILDING PLANNING (Chapter 3)
D�ySIGN
CRITERIA [Table R301.2(1)] Parapets and construction
V
Floor live load (Table R301.5) 75 psf (R302.2.2, R302.2.3)
Roof live load (Table R301.6) 20 psf Two-family dwelling separation (R302.3)
Ground snow load psf Dwelling unit penetrations (R302.4)
160 X Dwelling/garage opening/penetration protec-
Ultimate design wind speed mph tion (R302.5)
Wind exposure category (R301.2.1.4) 2-C X Dwelling/garage fire separation (R302.6)
i High wind design criteria applicable Under -stair protection (R302.7)
(R301.2.1.1) Y
X
Wall and ceiling finishes (R302.9)
Seismic design category (SDC)
[Figure R301.2(2)] X Flame spread index (R302.9.1)
DC C&D provisions (R301.2.2) X
index (R302.9.2)
rSmoke-developed
IISeathering NEG
Testing (R302.9.3, R302.9.4)
!Frost line depth
ermite area VH X Insulation (R302.10)
Decay area X Flame spread/smoke-developed
Winter design temperature (R302.10.1, R302.10.2)
ul
,lice barrier underlayment required Cellulose loose -fill and exposed attic
lood hazards X insulation (R302.10.3, R302.10.4)
FIRS
-RESISTANT CONSTRUCTION (R302) Testing (R302.10.5)
it-- Fireblocking (R302.11)
X Exterior walls
(R302.1, Tables R302.1(1) and R302.1(2)] Draftstopping (R302.12)
VI{ITownhouse separation (R302.2) Fire protection of floors (R302.13)
Continuity and structural independence Combustible insulation clearance (R302.14)
N (13302.2.1, R302.2.4)
PLANNING REQUIREMENTS (R303 through R305)
Use
Area (ft2)
Width
Ceiling height'
Natural light*
Natural ventilation*
Living
70
T-0"
T-0"
8% floor area
4% floor area
Dining
70
T-0"
T-0"
8% floor area
4% floor area
(Kitchen
N.A.
N.A.
7'-0"
8% floor area
4% floor area
edroom
Bathroom
70
N.A.
7'-0"
N.A
7'-0"
6'-8"
8% floor area
3 square feet
4% floor area
1'/2 square feet
` See Actions R303.1 & R303.3 for mechanical ventilation and artificial light and R303.4 for required whole -house mechanical ventilation.
t 6110" min. at plumbing fixtures and for non -habitable basements.
III Required heating (R303.9)
III
SANITATION (R306 and R307)
X Water closet
X Lavatory
X Tub or shower
X Kitchen area with sink
Sanitary sewer (Chapter 30)
Private disposal (Appendix I)
GLAZING (R308)
Identification (R308.1)
Louvered windows or jalousies (R308.2)
Human impact loads/hazardous locations
(R308.3, R308.4)
Skylights and sloped glazing (R308.6)
acil
BUILDING PLANNING (cont'd.)
GARAGES AND CARPORTS (R309)
X Floor surface noncombustible; sloped floor
(R309.1)
Carport: open two sides; noncombustible
floors; sloped floor (R309.2)
X Automatic garage door opener (R309.4)
Fire sprinklers (F!309.5)
EMERGENCY ESCAPE AND RESCUE OPENINGS
(R310)
X Where required (R310.1)
Areas, height, width, operations (R310)
Window wells (R310.2.3)
Under decks and porches (R310.2.4)
Bars, grilles, covers and screens (R310.4)
MEANS OF EGRESS (R311)
X General (R311.1)
X Egress door (R311.2)
X Landings at exterior doors
(R311.3 - R311.3.3)
Vertical egress (R311.4)
Construction and attachment (R311.5)
X Hallways (R311.6)
Stairway width, headroom, vertical rise, walk -
line (R311.7.1 - R311.7.4)
Stairway treads, risers profiles
(R311.7.5 - R311.7.5.4)
Stairway landings and walking surfaces
(R311.7.6, R311.7.7)
Handrails required (13311.7.8)
Handrail height, continuity, grip -size
(R311.7.8.1 - R311.7.8.4)
Stairway illumination (R303.7, R311.7.9)
Special stairways (R311.7.10)
Ramp slope, landings, handrails (R311.8)
GUARDS AND WINDOW PROTECTION (R312)
Required for open -sided surfaces, stairs,
ramps and landings > 30" above floor/
grade (R312.1.1)
Height - 36" (R312.1.2)
Opening limitations (R312.1.3)
Window fall protection (13312.2)
AUTOMATIC FIRE SPRINKLER SYSTEMS (R313)
Townhouses (R313.1)
One- and two-family dwellings (R313.2)
SMOKE ALARMS (R314)
X Referenced standards (R314.1)
X Location and interconnection
(R314.3, R314.4)
Power source (R314.6)
CARBON MONOXIDE ALARMS (R315)
X New construction (13315.1, R315.2)
Existing construction (R315.2.2)
Referenced standard (R315.6)
FOAM PLASTIC (R302.8, R316)
Labeling (R316.2)
Surface burning, thermal barrier, specific
approval (R316.3 - R316.8)
DECAY AND TERMITE PROTECTION (R317 and R318)
Protection required
(Table R301.2(1), R317.1, R318.1)
Quality mark (R317.2 and R318.1.1)
SITE ADDRESS (R319)
Address numbers (13319.1)
ACCESSIBILITY (R320)
Type B dwelling units applicable (R320.1)
ELEVATORS/PLATFORM LIFTS (R321)
Referenced standards (R321.1 - R321.3)
FLOOD -RESISTANT CONSTRUCTION (R322)
General (13322.1)
Hazard area and requirements
(13301.2.4, R309.3, R322.2, R322.3)
Design professional (R322.3.6)
STORM SHELTERS (R323)
General/referenced standard (R323.1)
SOLAR ENERGY SYSTEMS (R324)
System, installation, access
(R324.2 - R324.7)
MEZZANINES (R325)
Area, egress, openness (R325.2 -
SWIMMING POOLS, SPAS AND HOT TUBS
ISPSC (R326.1)
-4-
FOUNDATIONS (Chapter 4)
(R402)
Wood foundations (R402.1)
Concrete, compressive strength
(R402.2, R402.3) ,
NGS (R403)
Soil bearing value (13401.4, R403.1)
Footing width.
(Tables R403.1(1) - R403.1(3)],
Footing edge thickness; footing projection =
2" minimum, but <_ footing thickness
(R403.1.1)
Footings in SDC and D
(R403.1.2 and R403.1.6.1)
II Depth below (outside) grade = 12" minimum;
but below frost line (R403.1.4, R403.1.4.1)
Sill plate bolting in concrete/masonry ='/2" di-
ameter bolts, within 12" but not less than 7
bolt diameters from ends, 7" embedment
(R403.1.6)
Footings'adjacent to slopes (R403.1.7)
Frost -protected shallow foundations (R403.3)
Footings for precast concrete foundations
(R403.4)
NDATION/RETAINING WALLS (R404--R406)
`I Masonry foundation walls (R404.1.2)
G Wall height, unbalanced backfill, nominal
thickness (Tables R404.1.1(1) -
R404.1.1(4), R404.1.5.1]
Reinforcement size and spacing
(Tables R404.1.1(2) - R404.1.1(4)]
Concrete foundation walls (R404.1.3)
Wall height, unbalanced backfill, nominal
thickness (Tables R404.1.2(1) -
R404.1.2(8), R404.1.5.2]
Horizontal, and vertical reinforcement size and
spacing (Tables R404.1.2(1) -
R404.1.2(8), R404.1.3.2, R404.1.3.3.7]
Stay -in -place forms (R404.1.3.3.6.1)
SDC D provisions (R404.1.4)
Height above finished grade (R404.1.6)
Sill plate size (R404.3)
Precast concrete foundation walls (R404.5)
Drains required if habitable or usable spaces
are below grade* (13405)
Soil class (Table R405.1)
Dampproofing if basements are below grade*
(R406.1)
Waterproofing if high water table* (R406.2)
* If uninhabitable, see Under -Floor Space (R408)
COLUMNS (R407)
Protection from decay or corrosion
(R407.1 and R407.2)
X Structural requirements (R407.3)
Anchorage (R407.3)
Wood columns (minimum 4" square) (R407.3)
Steel columns (minimum 3" diameter, Sched-
ule 40 pipe) (R407.3)
UNDER -FLOOR SPACE (R408)
Ventilation (R408.1 and R408.2)
Unvented crawl space (R408.3)
Access (R408.4)
Removal of debris (R408.5)
Finished grade (R408.6)
Flood resistance (R408.7)
-5-
FLOORS (C
WOOD JOISTS AND GIRDERS (R502)
Species and grade (R502.1)
Joists —Sleeping areas, LL = 30 psf
[Table R502.3.1(1)]
Joists—Nonsleeping areas, LL = 40 psf
[Table R502.3.1(2)]
Cantilevered joists
(Tables R502.3.3(1) and R502.3.3(2)]
Girder and header spans
(Tables R602.7(1) - R602.7(3)]
Joists under bearing partitions (R502.4)
Bearing (1.5" minimum on wood or metal; 3"
on masonry or concrete) and lapped joists
(311) (R502.6, R502.6. 1)
Lateral restraint and bridging
(R502.7, R502.7.1)
Drilling and notching (R502.8)
Fastening (R502.9)
Framing of openings (R502.10)
Wood trusses (13502.11)
Draftstopping (R502.12)
LUMBER FLOOR SHEATHING (R503.1)
Allowable span (Table R503.1)
End joints (17503.1.1)
WOOD STRUCTURAL PANEL SHEATHING (R503.2)
Grade (R503.2.1)
Thickness (13503.2.1)
Allowable spans
(Tables R503.2.1.1(1) and R503.2.1.1(2)]
Installation [Table 602.3(1)]
PARTICLEBOARD UNDERLAYMENT (R503.3)
Grade (13503.3.1)
Thickness (R503.3.2)
Installation [Table R602.3(1)]
a
hapter 5)
TREATED -WOOD FLOORS (ON GROUND) (R504)
Base course: 4" thick with maximum 3/4'
gravel or crushed crushed stone (R504.2.1)
Moisture barrier: placed over base course
(R504.2.2)
Materials (R504.3)
STEEL FLOOR FRAMING (R505)
Cold -formed steel; applicability limits;
in -line framing (R505.1)
Structural framing (R505.2) I
Material (R505.2.1)
Corrosion protection (R505.2.2)
Identification (R505.2.4)
Fastening (R505.2.5)
Floor construction (R505.3)
CONCRETE FLOORS (ON GROUND) (R506)
X Thickness: 3'/2" minimum; Concrete strei
(R506.1)
X Support: prepared subgrade; maximum E
fill = 8"; maximum sand or gravel fill =
(R506.2.1)
,Base course: 4" graded, with 2" maximum
aggregate (R506.2.2)
Vapor retarder (R506.2.3)
X Reinforcement support (R506.2.4)
EXTERIOR DECKS (R507)
Support, attachment (R507.1 - R507.2.4)
Plastic composite materials (R507.3)
Decking/deck joists (R507.4, R507.5)
Deck beams (R507.6)
Deck posts, connections, footings
(R507.7.1, R507.8)
N
WALL CONSTRUCTION (Chapter 6)
CONSTRUCTION (R602)
_Construction
[Figures R602.3(i) and R602.3(2)]
_Stud grade (R602.2)
Design/construction (R602.3)
Stud spacing [R602.3.1, Table R602.3(5)]
Interior load -bearing walls (R602.4)
Interior nonbearing walls: 2" x 3" at 24" o.c.
or 2" x 4" flat at 16" o.c. (R602.5)
Drilling and notching —studs (R602.6)
Drilling and notching —top plate (R602.6.1)
Headers [Tables R602.7(1) - R602.7(3) and
Figure R602.7.2]
Fireblocking (R602.8, R302.11)
Cripple walls (R602.9)
Wall bracing, lines, panels
(R602.10.1, R602.10.2)
Required length of bracing, method
[R602.10.3, R602.10.4, Tables
R602.10.3(1) and R602.10.3(3)]
Minimum length, connections, support, joints,
cripple walls (R602.10.5 - R602.10.11)
Wall anchorage (SDC C and D) (13602.11)
Simplified wall bracing (R602.12)
EL WALL FRAMING (R603)
General (13603.1)
Structural framing (R603.2)
Material (R603.2.1)
Corrosion protection (R603.2.2)
Identification (R603.2.4)
Fastening (R603.2.5)
Wall construction (R603.3 - R603.5)
Headers (R603.6)
Studs, tracks and structural sheathing
(R603.7 - R603.9)
SHEATHING (R604 and R605)
Wood structural panels (R604)
Particleboard (R605)
MASONRY CONSTRUCTION (R606 - R610)
X General design (R606)
Seismic requirements (R606.12)
Glass unit masonry (13607)
X Exterior concrete wall construction (R608)
X Exterior windows/doors (R609)
Glass unit masonry (R610)
STRUCTURAL INSULATED PANEL WALL
CONSTRUCTION (R610)
Applicability (R610.2)
Materials (R610.3)
Wall panels, construction details
(R610.4 - R610.10)
-7-
WALL COVERING (Chapter 7)
INTERIOR WALL COVERING (R702)
Plaster material (R702.2)
Plaster support (R702.2.3)
X Gypsum board materials (R702.3.1)
X Gypsum board support, application and fas-
tening (R702.3.2 - R702.3.7)
X Ceramic the (R702.4)
Other finishes (R702.5 and R702.6)
Vapor retarders (R702.7)
EXTERIOR WALL COVERING (R703)
Water -resistive barrier (R703.2)
X Attachment and minimum thickness
[Table R703.3(1)]
Wood siding (R703.5)
KI
Wood shakes and shingles (R703.6)
Exterior plaster (R703.7)
Stone & masonry veneer (R703.8 & Figure
R703.8); Steel angle lintels-4" minimum
bearing each end (R703.8.3)
Veneer ties: #9 U.S. gage wire or #22 U.S.
gage by'/B' corrugated metal; horizontal
and vertical. spacing; 2.67 square feet
maximum area supported (wind > 30 psf
and SDC C or D, maximum.area = 2
square feet) (R703.8.4.1)
Flashing (R703.4 and R703.8.5)
Exterior insulation and finish systems
(R703.9)
Fiber cement siding (R703.10)
Vinyl siding (R703.11)
Other sidings (R703.12 - R703.17)
ROOF -CEILING CONSTRUCTION (Chapter 8)
WOOD ROOF FRAMING (R802)
Fire -retardant -treated wood (R802.1.5)
Framing details (R802.3)
Rafter ties (13802.3.1)
Collar ties (4' o.c., in upper third of attic)
(R802.3.1)
Purlins (2" x 4" at 4' o.c. minimum)
(Figure R802.5.1, R802.5.1)
Bearing (R802.6)
Cutting and notching (R802.7)
Engineered wood products (R802.7.2)
Lateral support and bridging (R802.8)
Framing of openings (R802.9)
Wood trusses (R802.10)
Roof tie -down (R802.11)
CEILING JOISTS [Tables R802.4(1), R802.4(2)]
Without attic storage, LL = 10psf
With attic storage LL = 20psf
Spacing
Species and grade
Span
Size
RAFTERS [Tables R802.5.1(1) - R802.5.1(8)]
Ground snow load/LL = 20 psf
Controlling design (LL or snow)
Ceiling not attached/ceiling attached
Spacing
Species and grade
Span
Size
Hc/HR; Adjustment factor
ROOF SHEATHING (R803.2)
Grade
X Thickness
FRTW allowable stresses/grading
X Allowable spans [Table R503.2.1.1(1)]
X Installation (R803.2.3)
ROOF -CEILING CONSTRUCTION (cont'd.)
EL ROOF FRAMING (R804) Roof construction (R804.3)
General (R804.1) Roof tie -down (R804.3.8)
Structural framing (R804.2) ROOF VENTILATION (R806)
Material (R804.2.1) Ventilation requirements (R806.1 - R806.5)
Corrosion protection (R804.2.2)
ATTIC ACCESS (R807)
Identification (R804.2.3) X
Access requirements (807.1)
Fastening (R804.2.5)
ROOF ASSEMBLIES (Chapter 9)
= CLASSIFICATION (R902)
X Roof covering materials (R902.1)
PROTECTION (R903)
.Flashing (R903.2)
.Coping (R903.3)
.Roof drainage (R903.4)
O TERIALS (R904)
X Compatibility; specifications; physical charac-
teristics; identification (R904.2 - R904.4)
AREMENTS FOR ROOF COVERINGS (R905)
X Underlayment (R905.1.1, R905.1.2)
X Asphalt shingles (R905.2)
Clay and concrete tile (R905.3)
Metal roof shingles (R905.4)
Mineral -surfaced roll roofing (R905.5)
Slate shingles (R905.6)
Wood shingles (R905.7)
Wood shakes (R905.8)
Built-up roofs (R905.9)
Metal roof panels (R905.10)
Modified bitumen roofing (R905.11)
Thermoset single -ply roofing (R905.12)
Thermoplastic single -ply roofing (R905.13)
Sprayed polyurethane foam roofing (R905.14)
Liquid -applied roofing (R905.15)
Photovoltaic shingles (R905.16)
ROOF INSULATION (R906)
General (R906.1)
ROOFTOP - MOUNTED PHOTOVOLTAIC SYSTEMS
(R907)
Materials and installation (R907.1 - R907.5)
REROOFING (R908)
Materials and methods (R908.1)
Structural support (R908.2)
Replacement/re-covering (R908.3, R908.4)
ROOFTOP - MOUNTED PHOTOVOLTAIC,
PANEL SYSTEMS (R909)
Materials and installation (R909.1 - R909.3)
CHIMNEYS AND FIREPLACES (Chapter 10)
RY FIREPLACES (R1001)
Construction
(Figure R 100 1. 1 and Table R 1001.1)
SDC D reinforcing/anchorage
(R1001.3 and R1001.4)
Firebox walls and dimensions
(R1001.5 and R1001.6)
Steel fireplace units (R1001.5.1)
Lintel (noncombustible) (R1001.7)
Hearth extension (R1001.9, R1001.10)
Fireplace clearance (R1001.11)
Fireblocking (R1001.12)
MASONRY CHIMNEYS (R1003)
Construction (Table R1001.1, R1003.2,
R1003.3, and Figure R1001.1)
Corbeling (R1003.5)
0
CHIMNEYS AND FIREPLACES (cont'd.)
Changes in dimension (R1003.6)
Additional load (R1003.8)
Termination (R1003.9)
Spark arrestors (R1003.9.2)
Wall thickness; >_ 4" (R1003.10)
Flue lining - material/installation
(R 1003.11 and R 1003.12)
Multiple flues (R1003.13)
Flue area (appliance) (R1003.14)
Flue area (masonry fireplace) (R1003.15)
Inlet (R1003.16)
Cleanout opening (R1003.17)
Chimney clearance (R1003.18)
Fireblocking (R1003.19)
Chimney crickets (R1003.20)
FACTORY -BUILT FIREPLACES (R1004)
Listed and labeled (R1004.1)
Installation (R1004.2 - R1004.5)
FACTORY -BUILT CHIMNEYS (R1005)
Listed and labeled (R1005.1)
Installation (R1005.3 and R1005.4)
EXTERIOR AIR SUPPLY (R1006)
Intake size (R1006.2, R1006.4)
ENERGY EFFICIENCY (Chapter 11)
Compliance; information
(N1101.5, N1101.13)
Climate zone (Table N1101.7)
Building thermal envelope (N1102)
Systems (N1103)
Electrical (N1104)
Simulated performance (N1105)
ERI compliance alternative (N1106)
Existing buildings (N1107- N1111)
MECHANICAL (Chapters 12-23)
Appliance labeling (M1302, M1303)
Appliance access (M1305, M1401)
Appliance installation (M1307)
Heating and cooling equipment; load calcula-
tions (Chapter 14)
Exhaust systems (Chapter 15)
Duct systems (Chapter 16)
Combustion air (Chapter 17)
Application (G2401.1)
General regulations (G2404)
Appliance location (G2406)
Air requirements (G2407)
Installation (G2408)
Chimney and vent location and terminations
(Chapters 10 and 18)
Special equipment (Chapter 19)
Boilers/water heaters (Chapter20)
Hydronic piping (Chapter2l)
Special piping and storage systems
(Chapter 22)
Solar thermal energy systems (Chapter23)
Penetrations of fire -resistance rated assem-
blies (R302.4, R302.5)
FUEL GAS (Chapter 24)
Clearances (G2409)
Electrical and electrical bonding
(G2410, G2411)
Pipe sizing (62413)
Piping materials (G2414)
-10-
FUEL GAS (cont'd)
Piping installation (G2415 and G2419) Venting (G2425 - G2429)
Piping. support (G2418 and G2424) Misc appliances
Valves, controls, connections (G2423, G2430 - G2454)
(G2420, G2421 and G2422)
PLUMBING (Chapters 25-33)
,Water service location and depth
(P2603, P2604)
,Sanitary and storm sewer location and depth
(P2603, P2604)
Piping support (Table P2605.1)
Listed plastic materials (P2609)
Plumbing fixtures (Chapter27)
Water heater size and location (Chapter28)
Water supply and distribution system -design
and calculations (Chapter29) .
Dwelling unit fire sprinkler systems (P2904)
NFPA 13D system (P2904.1)
Temperature rating
(P2904.2.1, P2904.2.2)
Freezing protection (P2904.2.3)
Sprinkler coverage (P2904.2.4)
_ Piping materials (P2904.3)
Flow rates (P2904.4.1, P2904.4.2)
Water supply capacity (P2904.5.2)
Pipe sizing (P2904.6)
Drain, waste and vent pipe sizing and riser
diagram (P3004, P3005, Chapter3l)
Sumps and ejectors (P3007)
Backwater valves (P3008)
Fixture traps, (P3201)
Storm drainage (Chapter 33)
Penetrations of fire -resistance rated assem-
blies (R302.4, R302.5)
ELECTRICAL (Chapters 34-43)
Penetrations of fire -resistance rated assem-
blies (E3402.2)
Listed and labeled materials (E3403)
Service equipment and location
(E3405, E3601, E3606)
Service size and load calculations (E3602)
Available fault current (E3606)
System grounding (E3607)
Required branch circuits (E3703)
Feeder requirements and load calculations
(E3704)
Wiring methods (Chapter 38)
Required lighting and receptacle outlets
(E3901, E3903)
Ground -fault and arc -fault circuit -interrupter
protection (E3902)
Devices and lighting fixtures (Chapter40)
Appliance installation (Chapter4l)
Swimming pools (Chapter42)
Class 2 remote -control, signaling and power -
limited circuits (Chapter43)
MANUFACTURED HOUSING USED AS DWELLINGS (Appendix E)
ions adopted (13102.5)
Compliance with Appendix E verified
-11-
PASSIVE RADON GAS CONTROLS (Appendix F)
Provisions adopted (R102.5) Compliance with Appendix F verified
PATIO COVERS (Appendix H)
Provisions adopted (R102.5)
Compliance with Appendix H verified
PRIVATE SEWAGE DISPOSAL (Appendix 1)
Provisions adopted (R102.5)
Compliance with Appendix I verified
EXISTING BUILDINGS AND STRUCTURES (Appendix J)
Provisions adopted (R102.5)
Compliance with Appendix J verified
SOUND TRANSMISSION (Appendix K)
Provisions adopted (R102.5)
Compliance with Appendix K verified
HOME DAY CARE—R-3 OCCUPANCY (Appendix M)
Provisions adopted (R102.5)
Compliance with Appendix M verified
AUTOMATIC VEHICULAR GATES (Appendix O)
Provisions adopted (R102.5) Compliance with Appendix O verified
SOLAR -READY PROVISIONS (Appendix U)
Provisions adopted (R102.5)
NOTES
Compliance with Appendix U verified
-12-