5T" EDITION FBC ENERGY CONSERVATION CODE R403.2.2
Duct Sealing (Duct Blaster) Certification
Prescriptive and Performance Method
Z Lot#•
Date: Permit #: I o " &te�� !,1 _1�
-r-�il } �, �Y � Address: ��— c - �l
Contractor: c— �/�� �l>!�e_
Construction: 91'P'0`St Construction Test ❑- Rough -in Test
Test Conditions:
Date: J/ i2 Floor Area (ft2): Bedrooms
G
Time: j p�, Primary Location of Supply Ductwork Hallways
Indoor Temperature (F): Primary Location of Return Ductwork
Outdoor Temperature (F):
Total Leakage Test (Outside) Duct Leakage: ❑ Default ❑ Prop. Leak Free ® Proposed Qn
<•03�
Test Pressure: -25 (Pa) As Proposed on Florida Energy Efficiency Code
Baseline Duct Pressure (optional) NSA _(Pa) Asper 803 of Resnet
Duct Press. (Pa) Flow Ring Fan Press Flow (cfm)
Installed (pa) Results: El Pass ❑ Fail
-25 74 25 Total Leakage (cfm):
Total Leakage per 100 sgft: _
CFM25 x 100 divided by the CFA = Duct Leakage
CFM/100 sgft.
QN Test Results:
R403.2.2 Sealing (Mandatory). All ducts, air handlers, and filter boxes and building cavities that form the primary air containment passageways for air distribution
systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this
code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals
as defined in Section 553.993(5), or (7), Florida Statutes, or individuals licensed as set forth in section 489.105(3)(f), (g), or (i), Florida Statutes, to be "substantially
leak free" by either of the. following: 1. Post construction test: Total leakage shall be less than or equal to 4 cfm per 100 square feet of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All registered boots
shall be taped or otherwise sealed during the test. 2. Rough -in test: Total leakage shall be less than or equal to 4 cfm per 100 square feet of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure. All registers shall be taped or
otherwise sealed during the test. If the air handler is not installed at the time of the test, total leakage shall be less than or equal to 3 cfm per 100 square feet
conditioned floor area. Exceptions: 1. The total leakage testis not required for ducts and air handlers located entirely within the building thermal envelope. 2. Duct
testing is not mandatory for building complying by Section 405 of this code.
Certification Tests will be accepted from the following Individuals:
1. Individuals defined under FS 553.993 (5) or (7)
2. *Individuals licensed under FS 489.105(3)(f), (g) or (i)
*FS 489 licensed individuals -will need to submit proof of certification from an approved organization indicating
education, training, use, and evaluation of testing results for the blower door and duct testing equipment and -
procedures /
Testing Comoanv
Company Name:
607 NW Commodity Cove
Address: Port St Lucie FL. 34986
772-924-35
I hereby certify that the above ct Sealin eakage results demonstrate compliance with 5th Edition FBC Energy
accordance w' ection R403..2.
Signature:
Printed Name: Michael Anderson /
GFA International
License/Certification #: BPI 5059963
fF;
Datet
Job
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
Phone:772-462-2165 Fax:772-462-6443
BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
12/12/18 Permit #:
FILE COPY
9 7" a 2
N �- f- m - - r--i
) New Construction — Complete
) Existing — After Addition
Hou"' a Infiltration Test Results SLC Climate Zone 2
CF V (50) _ Test Date: 12/12/18
Vol me - b
AC (50) = CFM (50) x 60 / Volume =� Mechanical Ventilation required less than 3 ACH
Pas ing results must be & ACH (50) or less Crass ( ) Fail
FBC, Energy
The � uilding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hou I�in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blo er door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Sect ion 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
app loved third party. A written report of the results of the test shall be signed by the party conducting the test and
pro ided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
the al envelope.
Residential
re the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
ure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
welling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Coripany Name:
GFA International, 77.2-924-3575 Address: 607 NW Commodity Cove, Port St. Lucie F
I h j'reby certify that the above House I
re uirements ia-accordance with Sep
re:
Name: Michael
e/Certification #: BPI 5059963
n results demonstrate compliance with FBC Energy Conservation
4.1.2 Climate Zone 2.
L'-
/a--7 -03(,.2-
rr uTe a m
fmi RdoIltIDshIJS Nabanaf Acsr. ill ccS
3601-1 Crossroads Parkway
Fort PllJerce, FL 34945
Gale Insulation
RECEIVE®
DEC 0 6 2Oi8
ST. .]DEC
Permitting
BUILDER: DR Horton SUBDIVISION: Creekside
JOB ADDRESS: 8617 Cobblestone Dr CITY; Fort Pierce
PERMIT#: M7 - 07>&2, LOT/BLOCK:28
INSULATION INSTALLATION CERTIFICATE
The uihdersigned hereby certifies that insulation has been installed in the above property as follows:
1. Exterior CBS walls have been insulated with Reflective Foil to thickness of '.7s" inches, which
according to Fi-Foil Company will yield an "R" value of 4.1
2. Ceiling Area (flat) has been insulated with Fiberglass Blow to a thickness of 13" i.nches, which
according to Knauf will yield an "R" value'of 38
3. Ceiling Area (vaulted) has been insulated with to a thickness of inches, which
according to will yield an "R" value of
4. Interior knee walls have been insulated with
according to
will yield an "R" value of
to a thickness of inches, which
5. Garage common walls adjacent to conditioned living space have been insulated with Fiberglass Batt
to a thickness of 3.5" inches, which according to Knauf will yield an "R" value of 13
General Contractor/Builder
Signature
Insulation Contractors Signature
License # CGC1512179
THEIAFFIANT, Jeremy Theisen IS PERSONALLY KNOWN TO ME. Sworn to and subscribed before me this 3
day " f Decemeber 2018
Notary Public, State of Florida
vn SE4 �,
JENNIFER SV/Ec7
NotaryPublic- Stateofflorida
Commission a GG 50011
My Comm. Expires Jan 29, 2021