HomeMy WebLinkAboutFBC ENERGY CONSERVATIONINDIAN RIVER COUNTYXITY OF VERO BEACH tBUILDING DIVISION CIO2 180127 • Street, Vero Beach, FL 3296 a ILE *FLORIOPQo Eddie�0� 5T" EDITION FBC ENERGY CONSERVATION CODE R403.2.2 Duct Sealing (Duct Blaster) Certification Prescriptive and Performance Method Z Lot#• Date: Permit #: I o " &te�� !,1 _1� -r-�il } �, �Y � Address: ��— c - �l Contractor: c— �/�� �l>!�e_ Construction: 91'P'0`St Construction Test ❑- Rough -in Test Test Conditions: Date: J/ i2 Floor Area (ft2): Bedrooms G Time: j p�, Primary Location of Supply Ductwork Hallways Indoor Temperature (F): Primary Location of Return Ductwork Outdoor Temperature (F): Total Leakage Test (Outside) Duct Leakage: ❑ Default ❑ Prop. Leak Free ® Proposed Qn <•03� Test Pressure: -25 (Pa) As Proposed on Florida Energy Efficiency Code Baseline Duct Pressure (optional) NSA _(Pa) Asper 803 of Resnet Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Installed (pa) Results: El Pass ❑ Fail -25 74 25 Total Leakage (cfm): Total Leakage per 100 sgft: _ CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sgft. QN Test Results: R403.2.2 Sealing (Mandatory). All ducts, air handlers, and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5), or (7), Florida Statutes, or individuals licensed as set forth in section 489.105(3)(f), (g), or (i), Florida Statutes, to be "substantially leak free" by either of the. following: 1. Post construction test: Total leakage shall be less than or equal to 4 cfm per 100 square feet of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All registered boots shall be taped or otherwise sealed during the test. 2. Rough -in test: Total leakage shall be less than or equal to 4 cfm per 100 square feet of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test, total leakage shall be less than or equal to 3 cfm per 100 square feet conditioned floor area. Exceptions: 1. The total leakage testis not required for ducts and air handlers located entirely within the building thermal envelope. 2. Duct testing is not mandatory for building complying by Section 405 of this code. Certification Tests will be accepted from the following Individuals: 1. Individuals defined under FS 553.993 (5) or (7) 2. *Individuals licensed under FS 489.105(3)(f), (g) or (i) *FS 489 licensed individuals -will need to submit proof of certification from an approved organization indicating education, training, use, and evaluation of testing results for the blower door and duct testing equipment and - procedures / Testing Comoanv Company Name: 607 NW Commodity Cove Address: Port St Lucie FL. 34986 772-924-35 I hereby certify that the above ct Sealin eakage results demonstrate compliance with 5th Edition FBC Energy accordance w' ection R403..2. Signature: Printed Name: Michael Anderson / GFA International License/Certification #: BPI 5059963 fF; Datet Job Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method 12/12/18 Permit #: FILE COPY 9 7" a 2 N �- f- m - - r--i ) New Construction — Complete ) Existing — After Addition Hou"' a Infiltration Test Results SLC Climate Zone 2 CF V (50) _ Test Date: 12/12/18 Vol me - b AC (50) = CFM (50) x 60 / Volume =� Mechanical Ventilation required less than 3 ACH Pas ing results must be & ACH (50) or less Crass ( ) Fail FBC, Energy The � uilding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hou I�in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blo er door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Sect ion 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an app loved third party. A written report of the results of the test shall be signed by the party conducting the test and pro ided to the code official. Testing shall be performed at any time after creation of all penetrations of the building the al envelope. Residential re the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a ure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation welling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Coripany Name: GFA International, 77.2-924-3575 Address: 607 NW Commodity Cove, Port St. Lucie F I h j'reby certify that the above House I re uirements ia-accordance with Sep re: Name: Michael e/Certification #: BPI 5059963 n results demonstrate compliance with FBC Energy Conservation 4.1.2 Climate Zone 2. L'- /a--7 -03(,.2- rr uTe a m fmi RdoIltIDshIJS Nabanaf Acsr. ill ccS 3601-1 Crossroads Parkway Fort PllJerce, FL 34945 Gale Insulation RECEIVE® DEC 0 6 2Oi8 ST. .]DEC Permitting BUILDER: DR Horton SUBDIVISION: Creekside JOB ADDRESS: 8617 Cobblestone Dr CITY; Fort Pierce PERMIT#: M7 - 07>&2, LOT/BLOCK:28 INSULATION INSTALLATION CERTIFICATE The uihdersigned hereby certifies that insulation has been installed in the above property as follows: 1. Exterior CBS walls have been insulated with Reflective Foil to thickness of '.7s" inches, which according to Fi-Foil Company will yield an "R" value of 4.1 2. Ceiling Area (flat) has been insulated with Fiberglass Blow to a thickness of 13" i.nches, which according to Knauf will yield an "R" value'of 38 3. Ceiling Area (vaulted) has been insulated with to a thickness of inches, which according to will yield an "R" value of 4. Interior knee walls have been insulated with according to will yield an "R" value of to a thickness of inches, which 5. Garage common walls adjacent to conditioned living space have been insulated with Fiberglass Batt to a thickness of 3.5" inches, which according to Knauf will yield an "R" value of 13 General Contractor/Builder Signature Insulation Contractors Signature License # CGC1512179 THEIAFFIANT, Jeremy Theisen IS PERSONALLY KNOWN TO ME. Sworn to and subscribed before me this 3 day " f Decemeber 2018 Notary Public, State of Florida vn SE4 �, JENNIFER SV/Ec7 NotaryPublic- Stateofflorida Commission a GG 50011 My Comm. Expires Jan 29, 2021