Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ELEVATION CERTIFICATE 5-27-19
S. DEPARTMENT OF HOMELAND CURITY SCANNED j OMB No. 1660-0008 deral Emergency Management Ag ncy BY Expiration Date: November 30, 2018 ational Flood Insurance Program Sg, ude County ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. opy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION A - PROPERTY INFORMATION FOR INSURANCE COMPANY- USE Building Owner's Name Policy Number. IIA1. WADE & ELIZABETH ONEY IA2. Building Street Address (including Apt, Unit, Suite, and/or Bldg. No.) or P.O. Route and Company NAIC Number. Box No. �14860 WATERSONG WAY City State ZIP Code �i� FORT PIERCE Florida 34949 IA3. Property Description (Lot and Block Numbers', Tax Parcel Number, Legal Description, etc.) PARCEL ID 2532-500-0060-000-3 LOT 46 WATERSON PUD PLAT NO. 1 IA4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) RESIDENTIAL A15. Latitude/Longitude: Lat. N 27°23' 26.OT' Long. W -8rP 15' 37.77" Horizontal Datum: ❑ NAD 1927 0 NAD 1983 I A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 6 A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) 1100.00 sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 0 c) Total net area of flood openings in A8.b 0.00 sq in d) Engineered flood openings? ❑ Yes x❑ No 9. For a building with an attached garage: a) Square footage of attached garage, 508.00 sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 3 c) Total net area of flood openings in A9.b 600.00 sq in d) Engineered flood openings? 0 Yes ❑ No II SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION �1. NFIP Community Name & Community Number B2. County Name B3. State III AINT LUCIE COUNTY, UNINCORPORATED 120285 SAINT LUCIE Florida . Map/Panel B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) Number Date Effectivel Zone(s) (Zone AO, use Base Flood Depth) Revised Date 1 111 C 0194 fI�AE J 02-16-2012 02-16-2012 6 it 10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9: ❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source: 11. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: II 12. Is the nuilding located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)7 ❑x Yes ❑ No Designation Date: 10-01-1983 ❑x CBRS ❑ OPA I FTA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 1 of 6 i E L EVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 I ,QORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE BuI ilding Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 4 60 WATERSONG WAY C ty State ZIP Code Company NAIC Number FORT PIERCE Florida 34949 II SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) 0 1. Building elevations are based on: ❑ Construction Drawings" ❑ Building Under Construction" © Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. 32. Elevations —Zones Al—A30, AE, AH, A (with BFE), VE, V1 V30, V (with BFE), AR, AR/A, AR/AE, AR/A1—A30, AR/AH, AR/AO. Complete Items C2.a=h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: ST LUCIE COUNTY BM "B-308" Vertical Datum: NAVD 1988 i Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 FX� NAVD 1988 ❑ Other/Source:. Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. feet meters a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 8.0 ❑X ❑ b) Top of the next higher floor 19.1 feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) 15.8 . 0 feet ❑meters d) Attached garage (top of slab) 6.0 0 feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 7.6 0 feet ❑ meters. (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 5.8 0 feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 6.1 0 feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including 5.8 Eg feet ❑ meters structural support SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION his certification is to be signed and sealed by a land surveyor,' engineer, or architect authorized by law to certify elevation information. certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. ltatement ere latitude and longitude in Section A provided by a licensed land surveyor? 0 Yes ❑ No 0 Check here if attachments. J ertifier's Name License Number L HARLES ARNOLD, PSM FLORIDA LS #4971 • Title VICE PRESIDENT ac e4o ompany Name II RNOLD SURVEYING, INC. ere Address 888 N KINGS HIGHWAY #425 ity State ZIP Code TORT PIERCE Florida 34951 ignature Date Telephone Ext. 05-27-2019 (772) 708-1819 �opy all es of this levatron Vertificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. mments (including type of equipment and location, per C2(e), if applicable) A8A & C2A FLEX SPACE SEPARATED BY WALL FROM GARAGE MEANING IT IS AN EOBTAINED USING HANDHELD DEVICE; CLOSURE; A91) ENGINEERED SMARTVENT MODEL 1546-510 RATED AT 200 SQ FT (SEE ATTACHED 3 REFERENCE SHEETS PROVIDED BY BUILDER); B9 LOT HAS SEVERAL ZONES BUT HOUSE LIES SOLELY IN ZONE AE-6; C2B REFERS TO ST FLOOR LIVING SPACE; C2C REQUESTED BY LOCAL INSPECTOR: HOUSE IS NOT IN V ZONE; C213 GARAGE SEPARATED Y WALL FROM FLEX SPACE MEANING GARAGE IS ATTACHED; C2E REFERS TO WATER HEATER; C2H REFERS TO PATIO; GS 1, 2, 5, 6, 7 & 8 COMPLETED BY SURVEYOR; PGS 3 & 4 LEFT BLANK INTENTIONALLY & IS NOT, CERTIFIED BY SURVEYOR; ELEVATION CERTIFICATE IS 8 PAGES WITH 3 PAGE ATTACHMENT FOR FLOOD VENT (PROVIDED BY BUILDER) FdMA Form 086-0-33 (7/15) Replaces all previous editions. Form rage z oT e E EVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 1 10ORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE B!' ilding Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 4 60 WATERSONG WAY u - C ty State ZIP Code Company NAIC Number F RT PIERCE Florida 34949 SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) IIr FOR ZONE AO AND ZONE A (WITHOUT BFE) F Zones AO and A (without BFE), complete Items E1—E5. If the Certificate is intended to support a LOMA or LOMR-F request, Sections A, B,and C. For Items E1—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, 4mplete ter meters. E �. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑_ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters above or ❑below the LAG. E . For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1 2 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E . Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. �I SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION TI �e property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or c immunity -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Pfbperty Owner or Owners Authorized Representative's Name A dress City State ZIP Code S gnature Date Telephone I C ° mments ❑ Check here if attachments. F MA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 3 of 6 E EVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 I PORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE B'i ilding Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 4860 WATERSONG WAY I C`ty State ZIP Code Company NAIC Number F li RT PIERCE Florida 34949 SECTION G — COMMUNITY INFORMATION (OPTIONAL) the local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete S�'ections A, B,' C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement u11ed in Items G8—G10. In Puerto Rico only, enter meters. G'I I ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) GI2. or Zone AO. G 3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes. G . Permit Number I G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued GII . This permit has been issued for: ❑ New Construction ❑ Substantial Improvement GIB. Elevation of as -built lowest floor (including basement) ❑ feet ❑ meters Datum ' of the building: - G 9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum GII 0. Community's design flood elevation: ❑ feet ❑ meters Datum L 'cal Official's Name Title I ` C" mmunity Name Telephone it S Ignature Date CI�mments (including type of equipment and location, per C2(e), if applicable) I i I I ❑ Check here if attachments. 1MA Form 086-0-33 (7/15) Replaces all previous editions. corm rage 4 or b i� I, FI FVATInN BUILDING PHOTOGRAPHS OMB No.1660-0008 CERTIFICATE See Instructions for Item A6. Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE B'°ilding Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 4860 WATERSONG WAY of C'ty State ZIP Code Company NAIC Number FORT PIERCE Florida 34949 1r, using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View'; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or dents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. f! �I 7 i I I I I. P Photo One oto One Caption FRONT VIEW - PHOTO TAKEN MAY 21, 2019 �116 OneU i I i I I I I tfli�lt, I Proto Photo Two Two Caption REAR VIEW - PHOTO TAKEN MAY 21, 2019 GlearPlotoTwo 11 FA Form 086-0-33 (7/15) Replaces all previous editions. roini rays a ui o 1I , I ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS 1 OMB No.1660-0008 Continuation Page Expiration Date: November 30, 2018 I I o',PORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE uilding Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number. 4860 WATERSONG WAY City State ZIP Code Company NAIC Number it FORT PIERCE Florida 34949 it f submitting morephotographs than will fit on the preceding page, affix the additionalphotographs below. Identify allphotographs 9 P 9 P 9 fY „. �� � ��. ith: date taken; Front View and Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, jhotographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. +'Cva I . s - s r • r "5►`-.._, - .. ... _-. ., . -. �., gyp, �. �^1.Ip}' P,{ Photo Three oto Three Caption LEFTMORTH VIEW - PHOTO TAKEN MAY 21, 2019 •clear Photo"Tttree ,.., I it l Photo Four P�oto Four Caption RIGHT/SOUTH VIEW - PHOTO TAKEN MAY 21, 2019 Gtear Qdota Four :. F IMA Form 086-0-33 (7/15) Replaces all previous editions. rO"" Fayc v 01 " Florida Building Code Online Professional . M 1 I Omm BCIS Home I Log In I User Registration I Hot Topic Submit Surcharge Stats r=< Facts Publications I FBC Staff I BCIS Site Map, Links Search Product Approval USER: Public User Product Approval Menu > Application Detail FL # FL5822-R5 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email 08/18/2017v. date reapply 08/23/17 O Smart Vent Products, Inc. 430 Andbro Dr Unit 1 Pitman, NJ 08071 (877)441-8368 info@smartvent.com Michael Graham Info@smartvent.com Michael Graham 430 Andbro Dr Unit 1 Pitman, NJ 08071 (877)441-8368 info@smartvent.com Category Structural Components Subcategory Products Introduced as a Result of New Technology Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer D Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Hermes F. Norero P.E. Evaluation Report Florida License PE-73778 Quality Assurance Entity Architectural Testing, Inc. Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden O Validation Checklist - Hardcopy Received Certificate of Independence FL5822 RS COI Smart Vent COI SS 2017-08-18 odf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1612.5(1)(1.2) 1708.2 .floridabuilding.org/pr/pr_app_dd.aspx?param=wGEVXQwtDgvMdF6zR4iI Lm1meckcmccEFNgF4cUyp4c%3d Florida Building Code Online Product Approval Method Method 2 Option B Date Submitted 08/18/2017 Date Validated 08/24/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products FL # Model, Number or Name Description 5822.1 SmartVent Model #1540-510 Dual Function Flood and Ventilation Vent Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5822 115 II 1540-510 SS 2017-08-23.pdf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +100/-500 Evaluation Reports Other: One vent may be used for up to 200 sq. ft. of interior FL5822 R5 AE PER5022 SS 2017-08-23.pdf space (minimum 2). FL5822 R5 AE SmartVent - Impact Requirements SS 2017- 08-23.Ddf Created by Independent Third Party: Yes 5822.2 SmartVent Model #1540-511 Dual Function Flood and Ventilation Vent Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5822 R5 II 1540-511 SS 2017-02-28.pdf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +100/-100 Evaluation Reports Other: One vent may be used for up to 400 sq. ft. of interior FL5822 R5 AE PER5022 SS 2017-08-23.pdf space (minimum 2). FL5822 R5 AE SmartVent - Impact Requirements SS 2017- 08-23.pdf Created by Independent Third Party: Yes 5822.3 SmartVent Model #1540-514 Garage Door Dual Function Flood and Ventilation Vent Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes FL5822 R5 II 1540-514 SS 2017-02-28.odf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Impact Resistant: N/A Design Pressure: +100/-100 Created by Independent Third Party: Yes Evaluation Reports Other: One vent may be used for up to 200 sq. ft. of interior space (minimum 2). FL5822 R5 AE PER5022 SS 2017-08-23.pdf FL5822 R5 AE SmartVent - Impact Requirements SS 2017- 08-23.pdf Created by Independent Third Party: Yes 5822.4 SmartVent Model #1540-520 Insulated Flood Vent Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5822 RS II 1540-520 SS 2017-08-23.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +300/-100 Other: One vent may be used for up to 200 sq. ft. of interior Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL5822 R5 AE PER5022 SS 2017-08-23 pdf space (minimum 2). FL5822 R5 AE SmartVent - Impact Requirements SS 2017- 08-23.pdf Created by Independent Third Party: Yes 5822.5 SmartVent Model #1540-521 Insulated Flood Vent Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5822 R5 II 1540-521 SS 2017-02-28.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-100 Other: One vent may be used for up to 400 sq. ft. of interior space (minimum 2). Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL5822 R5 AE PER5022 SS 2017-08-23.pdf FL5822 R5 AE SmartVent - Impact Requirements SS 2017- 08-23.odf Created by Independent Third Party: Yes 5822.6 SmartVent Model #1540-524 16" Garage Door Flood Vent Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-100 Other: One vent may be used for up to 200 sq. ft. of interior space (minimum 2). FL5822 R5 II 1540-524 SS 2017-02-28 pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL5822 R5 AE PER5022 SS 2017-08-23 pdf FL5822 R5 AE SmartVent - Impact Requirements SS 2017- .aspx?param=wGEVXQwtDgvMdF6zR4iHLmlmeckcmccEFNgF4cUyp4c%3d 2/3 0/10/2017 Florida Building Code Online 08-23.odf Created by Independent Third Party: Yes 5822.7 SmartVent Model #1540-570 Wood Wall Insulated Flood Vent Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-100 Other: One vent may be used for up to 200 sq. ft. of Interior space (minimum 2). FL5822 115 II 1540-570 SS 2017-02-28 Ddf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL5822 R5 AE PER5022 SS 2017-08-23 Ddf FL5822 R5 AE SmartVent - Imoact Requirements SS 2017- 08-23.Ddf Created by Independent Third Party: Yes 5822.8 SmartVent Model #1540-574 14.5" Garage Door Flood Vent Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-300 Other: One vent may be used for up to 200 sq. ft. of interior space (minimum 2). FL5822 115 II 1540-574 SS 2017-02-28,odf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL5822 115 AE PER5022 SS 2017-08-23 Ddf FL5822 R5 AE SmartVent - Impact Reauirements SS 2017- 08-23.Ddf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click 11s_rg_. Product Approval Accepts: ® � � —=k Credit Card Safo .floridabuilding.org/pr/pr_app_ tl.aspx?param=wGEVXQwtDgvMdF6zR4iHLmlmeckcmccEFNgF4cUyp4c%3d 3/3 FRAME FIGURE 2 SIDE VIEW DETAIL DIAGRAM Diginfly Re omIamsignd by pp Hnthis document� MODEL 1540-510 Date:2017.05.29ta5aa9a4nv _AE DUAL FUNCTION ROOD AND VENTILATION VENT _ SMART VENT Foundation Flood Vents 430 AnUnit 1 Pitman NJ NJ 08071 SMART VENT® DUAL FUNCTION FLOOD 877-441-8368 AND VENTILATION VENT WWW.SMAR7VENT.COM MODEL 1540-510 THE IWOtMATM4 CONTADEO IN THIS ]DRAWING N0• RA THO. IS E SE PROPERTY OF SMART VENT INC. ANY REPRODUCTION OR USE 1540-510 OF TMS RiOtMATIOi VITHOUf THE WRITTEN PERMISSION OF SMARTVENT OTC GATE 5-21-15 SHEET 1 OF 2 IS PROIOITEIL Smart VENT 8 �I7— 441— 8368 www.smartvent.com INSTALLATION INSTRUCTIONS & DETAILS MODEL 1540-510 DUAL FUNCTION FLOOD AND VENTILATION VENT REV. 6-21-16 1110 1.! REMOVE VENT DOOR FROM VENT FRAME (TURN UPSIDE DOWN,'ROTATE BOTTOM OF DOOR OUTWARD AND SLIDE OUT) 2. PREPARE A CLEAN 16.25' WIDE BY 8.25' HIGH ROUGH OPENING (APPROX. 1 BLOCK WIDE X 1 BLOCK HIGH) FOR.EACH VENT. ENSURE THE BOTTOM OF THE ROUGH OPENING IS NO MORE THAN 12' ABOVE THE FINISHED GRADE. 3.11 APPLY A BEAD OF HURRIBOND GRIP & SEAL OR EQUIVALENT ADHESIVE AROUND THE BACK OF THE FLANGE ON THE VENT FRAME (FIG. 2) 4.1 INSERT INSTALLATION CUPS INTO THE TWO SLOTS ON THE TOP AND TWO SLOTS ON THE BOTTOM OF THE FRAME. 5.�THE SPRING ARM OF THE CUPS SHOULD BE ON THE OUTSIDE OF THE VENT FRAME. 'COMPRESS THE BOTTOM TWO CUPS AND BEGIN SUPPING THE FRAME INTO THE OPENING. ENSURE THAT THE BOTTOM CUPS ARE IN THE OPENING BEFORE ALLOW THEM TO DECOMPRESS. I 6.1 WITH THE FRAME NOW IN THE OPENING, AND THE BOTTOM SPRINGS IN PLACE, COMPRESS THE TOP SPRINGS AND PUSH THE VENT FRAME INTO THE OPENING COMPLETELY UNTIL THE FRAME IS FLUSH WITH THE WALL 7., RE -CHECK THAT FRAME IS SQUARE AND SLOTS ARE CLEAR OF DEBRIS, AND CAULK. h ' B. INSTALL THE DOOR INTO FRAME BY GRASPING THE BOTTOM OF DOOR (WITH FLOAT PINS DOWN) AND FRONT (SMALL SCREEN IN FRONT). SLIDE DOOR INTO FRAME AND ROTATE UNTIL IT IS LATCHED. 9.', TO OPEN THE DOOR INSERT TWO CREDIT CARDS INTO THE FLOAT SLOTS AS SHOWN IN THE DIAGRAM. THIS WILL UNLATCH THE DOOR FOR REMOVAL AND CLEANING. DETAILED SPECIFICATIONS: MATERIAL STAINLESS STEEL OPERATION FLOOD: AUTOMATIC NON -POWERED ACTIVATION AND OPERATION VENT REMAINS CLOSED AND LOCKED UNTIL ACTIVATED OPERATION AIR: AUTOMATIC LOUVERS FULLY OPEN AT 75 DEG. FULLY CLOSED AT 35 DEG. NO POWER REQUIRED INSTALLATION: SECURED W/ 4 STAINLESS STEEL INSTALLATION CUPS INCLUDED AND AN ADHESIVE HYDROSTATIC RELIEF 200 SQ. FT PER VENT VENTILATION: 51 SO. IN. PER VENT NOTE VAPOR BARRIER ALLOWS FOR REDUCED VENTILATION REQUIREMENTS FLOOD: MINIMUM OF 2 VENTS PER ENCLOSED AREA MOUNTED ON AT LEAST TWO DIFFERENT WALLS COLORS: STAINLESS (STANDARD) EXTERIOR POWDER COATED WHITE, WHEAT, GRAY, AND BLACK (AVAILABLE) MEETS THE REQUIREMENTS FOR ENGINEERED OPENINGS AS SET FORTH BY: FEMA, NFIP, ICC, & ASCE SUPPORTIVE DOCUMENTS, TB 1-08. 44CFR 60.3(C)(5), ASCE 24-14 ICC EVALUATION # ESR-2074 SHEET2 OF 2