HomeMy WebLinkAboutPROPOSED UTILITY STRUCTURE..
CCUPANCYGROUP:
oFBC
U
APPROVED PRODUCTS LIST
GENERAL MOTES:
CONSTRUCTION TYPE:
II-B
1.
THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL
RISK CATEGORY:
I
APPROVAL
ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, FINISH
PRODUCT CATEGORY SUB CATEGORY
MANUFACTURER
FLOOR ELEVATIONS AND SLOPES, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS.
BUILDING ENCLOSURE TYPE:
ENCLOSED
No. &DATE
2.
THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY I) CAPABLE OF SUPPORTING DEAD LOAD OF
WIND EXPOSURE CATEGORY:
C
THE STRUCTURE. AND APPLICABLE LIVE AND WIND LOADS._ IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS,
STRUCTURAL COMPONENTS ROOF DECK
UNION CORRUGATING COMPANY
FL9555.2-R4
OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CARPORTS
MP
ULTIMATE WIND SPEED (MPH):
150
ANYWHERE, INC., WHICH EXERT ADDITIONAL. LOADS ON -THE STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC.,
26 Gauge MasterRib Panel
12/12/17
SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS.
NOMINAL DESIGN WIND SPEED (MPH):
116
SCANNED
STRUCTURACCONiPONENTS=STREC-Tt�CtNALt
=UNION-CORRUGATING-C-OMP_-A
—-L9555.2-R4_
3.
ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS.
MEAN ROOF HEIGHT (FEET):
12.08
.
26 Gauge MasterRib Panel
_
12/12/17 a
4.
y�
ALL STEEL TUBING SHAiE8E50 KSt GALVANIZEnTEEPW_ -FASTENERS-SHALL--SEGALVANIZED-ORSTPJNLES5 STE_ - — - _ _ _ ` y
_ QO�NGLE(DEGREES):
14.0
DESIGN PRESSURES (PSF):
EXTERIOR DOORS SWINGING ELIXER DOOR AND METAL COMPANY FL17996.5-R1 5. ALL FIELD FRAMING CONNECTIONS SHALL BE 1F12-14 x 1' SELF DRILLING SCREWS WITHOU.T.CONTROLSEAL WASHER. ALL SHOP FRAMING
Series 401
01/29/18
CONNECTIONS SHALL BE WELDED.
6.
CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40.
ROOF:
ZONE 1:
+16.0 / -25.
EXTERIOR DOORS ROLL -UP
ASTA INDUSTRIES INC.
FL8888.1-R5
CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH.6X6-W1.4XW1.4 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH
ZONE 2:
+16.0 / -36.5
Mode1203
10107/17
SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116.
ZONE 3:.
+16.6/-57:s
7.
CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TITE MODEL AT1252. OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT.
DESIGN ROOF PRESSURES:
+16;01.30.6
8.
POST/RAFTER BRACING: BRACE ON EVERY POSTIRAFTER CONNECTION, EXCEPT FOR END WALLS AND GABLE ENDS.
WALLS:
ZONE 4:
+26.71-29.1
9.
SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R3180 OF THE FLORIDA
ZONE 5:
DESIGN WALL PRESSURES:
+26.7 / -32.5
+26.71.29.8
BUILDING CODE, SIXTH EDITION (2017) - RESIDENTIAL, AND SECTION 1816.1 OF THE FLORIDA BUILDING CODE, SIXTH EDITION.(2017) - BUILDING.
MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,000 PSFIS ASSUMED.
SWINGING DOOR:
+29.91.34.7
10.
14 GA FRAMING: 2-1/2' x 2-1/2' TUBE STEEL (TS) WITH 2-1/4' x 2-114' TS NIPPLES.
ROLL -UP DOOR:
+28.01.31.1
12 GA FRAMING: 2-1/4' x 2-1/4' TS WITH 2' x Y TS NIPPLES.
NOTE: 14 GA FRAMING.
FRONT ELEVATION
SCALE:'1/8'=1'- '.
LEFT SIDE ELEVATION
SCALE: 1/8' -1'
RIGHT SIDE ELEVATION .
SCALE: 1/8' =1'
REAR ELEVATION
SCALE: 1/81 a 11.. .
METAL FRAMING AND SIDING PREFABRICATED BY
CARPORTS ANYWHERE
P.O. BOX 776
STARKE, FL 32091
THESE ENGINEERING DRAWINGS ARE THE PROPERTY
OF BECHTOL ENGINEERING & TESTING, INC. AND
CARPORTS ANYWHERE, INC. THESE DRAWING MAY
NOT BE REPRODUCED WITHOUT THE WRITTEN
CONSENT OF BECHTOL ENGINEERING & TESTING, INC.,
AND CARPORTS ANYWHERE, INC.
THIS IS TO CERTIFY THAT THE CALCULATIONS AND
SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE
UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN
ACCORDANCE WITH THE -REQUIREMENTS OF SECTION 1609
OF THE FLORIDA BUILDING CODE, SIXTH EDITION.(2017). THE
PLANS ARE VALID UNTIL THE NEXT REVISION OF THE
FLORIDA BUILDING CODE.
\\`1%111111/117/,
BECHTOL ENGINEER D° ING, INC.
:605 WEST NEW YORK AVENL ,'
DELAND, FLORIDA 32720 38538
Certificate of dzafion N O•
UJ
Thomas Be tol, P.E. /� S'SA OF
Florida Licen i53i i p, �ri�
PROPOSED UTILITY STRUCTURE
8680 HIDDEN -PINES ROAD
FT. PIERCE, FLORIDA .
.rme ' .. - we .. 5l2/18
,OECHTOL-ENGINEERING .RR. NOTED
AND 7FSW NG, Ina
TB. G18002
c0asutTWc cD)i[cwau- ea�¢ A4 AND MAMMS TWM DM*M .
"°°°°°°"°'wwTB . SHEET 1 OF 3
TS BOX EAVE RAFTER
MINIMUM 6' LONG TS NIPPLE
NIPPLE To 3116
SECURE WITH (4) #12-14x 314'
INSTALL 1/2' x 5.1/2' EXPANSION ANCHOR
RAFTER
SELF -DRILLING FASTENERS
THROUGH BASE RAIL WITHIN 6' OF EACH
MINIMUM 6' LONG TS NIPPLE
BOW ALONG SIDES OR INSIDE EVERY
48' 16 GA U-CHANNEL BRACE
SECURE WITH (4) #12-14 x 3/4-
SELF -DRILLING FASTENERS
TS RAFTER POST (CORNER)
OTHER END WALL POST ALONG END
BRACE ANGLE SHALL BE MIN.45'
NIPPLETO 3/16'
WALL SECTIONS
o TO MAX. 60' FROM HORIZONTAL
BASE RAIL
1-112' x 1-112' x 2' 16 GA CLIP
E
ANGLE, SECURE TO RAFTER
POST AND BASE RAIL
MINIMUM 2-1/4' EMBEDMENT
6'
i i WITH (4) #12-14 x 3W SOF's
TS RAFTER POST
o
GROUND SURFACE
- — -
- MINIMU—fJf6'TONGTSNIPP ---
NIPPLETO 3/16'
BASE RAILCONTINUOUS
- -
-101
_
-- -- — _ _ - _
. . , \/\�/. �\\/\\�\\,•�� '
- - - - _ _ -
12
SECURE RAFTER AND POST
Q
TO NIPPLE WITH (4) #12-14 x 3/4-
SELF-DRILLING FASTENERS
of
TS CONTINUOUS BASE RAIL
MONOLITHIC CONC. FOOTING (2500 PSI MIN.)
TS RAFTER POST
REINFORCED WITH 2 #Ss CONTINUOUS
BOX EAVE RAFTER/CORNER POST
RAFTER POST/
��CONCRETE MONO. SLAB BASE RAIL ANCHORAGE
CONNECTION DETAIL
BASE RAIL CONNECTION DETAIL
END POST/BASE RAIL CONNECTION DETAIL
,
4
t Not To Scale
L
`�
Not To Scale
Not To Scate
NOt TO Scale
TS TRUSSED RAFTER CHORD,
OR NONSTRUCTURAL HEADER
3n6' WELD, CONTINUOUS,
TS POST
3116' WELD, BOTH SIDES,
TOP AND BOTTOM ALL FOUR SIDES, TOP AND
(12 GA FOR ROLL -UP DOOR FRAME)
(TYPICAL ALL TRUSS POSTS) BOTTOM TRUSS CHORDS
TS RAFTER
2' x T x 2' 16 GA ANGLE CLIP
SECURE TO POST AND TOP OF
TS END POST OR DOOR/
HEADER, OR BOTTOM OF WINDOW
WINDOW FRAME POST 2'x2'xT 16 GA ANGLE CLIP
RAIUGIRT WITH #12-14x 3/4' SDFs
�e
TS POST
TS NONSTRUCTURAL HEADER SECURE TO POST (EACH SIDE) AND
�e
(12 GA FORNON-STRUCTURAL
ROLL-UP DOOR FRAME), RAFTER CHORD/RAIL WITH (4) #12-14x 3/4-
BASE RAIL, OR WINDOW RAIL SDF's, (2) ON BOTTOM AND (2) ON SIDE
2'x2x2' 16 GA ANGLE CLIP
NOTE: AT ROLL -UP DOOR OPENINGS,
TS NONSTRUCTURAL HEADER
SECURE TO POST AND
POST SHOULD BE FLUSH WITH RAIL
(12 GA FOR ROLL -UP DOOR FRAME)
RAFTER WITH #12-14 x 314'
END. CLIP POST TO RAIL ONLY ON
SDF'S, (2) ON TOP AND
SIDE OPPOSITE THE OPENING.
(2) ON SIDE
OR
TS END POST 2'x4' 16 GA PLATE
TS WINDOW RAIL (OR GIRT
SECURE TO EACH SIDE OF
FOR VERTICAL SIDING OPTION)
POST/RAFTER CONNECTION
WITH (4) #12-14 x 3W SDFs,
(2) ON POST, (2) ON RAFTER
POST TO NON-STRUCTURAL HEADER, BASE
NON-STRUCTURAL HEADER OR WINDOW
�I TRUSSED RAFTER CENTER CONNECTION DETAIL
RAIL, OR WINDOW RAIL CONNECTION DETAIL
RAIL TO POST CONNECTION DETAIL
END POST/RAFTER CONNECTION DETAIL
8 Not To Scale
5
6
7
Not To ScaleLi
Not To Scale
Not To Scale
BECHTOL ENGINEERING A{ G
1' 16GAUGE FURRING CHANNEL FASTENED TO EACH
ffi,[�.•
605 WEST NEW YORKAVENUE �� �.t�+�N Cjy i
�•
RAFTER WITH (2) #12-14 x 3/4' SELF -DRILLING FASTENER SPACED
DELAND, FLORIDA 32720 ;
NOT MORE THAN 48' O.C.
Certificate of Auth 'on No. ; NO.
385
26 GA. METAL ROOF PANELE3
Thomas Bach , P.E.
-
Florida Licens
2-1/4' FOR 16 GAUGE U-CHANNEL BRACE
s/ r
12 GA FRAMING FASTENED TO THE POST AND
'
/ Q N \\\
L
TS RAFTER
2-1/2' FOR RAFTER, 4'
14 GA FRAMING F DRILLWG(SCREws AT
ROOF PANEL ATTACHMENT
EACH END (4 PER BRACE)
Not To Scale
BRACE SECTION
PROPOSED UTILITY STRUCTURE
8680 HIDDEN PINES ROAD
Not To Scab
FT. PIERCE, FLORIDA
5/2118
Er BECHTOL ENG/NEER/NG RR Nrs
AND TE=NG, Ina
TB G18002
CCl= Ma CEO1MW C/1, ervulosueitw Arm NNMKS TOTING [NCINa tS
CaS" cf�N'00 W= TB SHEET 3 OF 3