Loading...
HomeMy WebLinkAboutPROJECT INFORMATION BOAT LIFT/— E /— H r , B -ftO� K C .I —A 1 B s C Equal Equal B A ST. LUCIE COUNTY BUILD DIVISION REVIEWED FOR COMPI REVIEWED BY/ / JOB SITE OR NO I FILE COPY DATE NOTES REVISIONS 0110712018 Changed FBC Note Scale: 3/8" = 1 '=0" .V%% ,� 10% NOT VALID UNLESS SIGNED WITH ORIGINAL NGINEER'S SIGNATURE AND ED EMBOSSED SEAL ARK E. WEBER, P.E. LICENSE #53895 1 CA 30702 9 l MW, ENOFNEERING, INC 6810 NORTH STATE ROAD 7 COCONUT CREEK, FL 33073 Ofc: 954-617-8143 WWW.MwEngineering.net OCANxFa RECEIVED JUL 16 2018 ST. Lucie County) Ptrmiuinp General Notes: • Design in accordance with Florida Building Cgde, 6th Edition (2017). • This lifting structure has been designed to withstand wind loads associated with speeds of V (ult) = 175 MPH, (3 Second Gust) Exposure 'D' without a boat on the lift per ASCE 7-10 using above ground sign/wall method. The lifting structure including boat has been designed to withstand wind speeds of V (ult) = 73 MPH in Exposure 'D'. • Boats shall not be stored on lift during high wind events. • Do not scale drawings for dimensions. • Licensed Contractor to verify locatign of existing utilities prior to commencing work. • The Licensed contractor to install and remove all shoring and bracing as required for the proper installation of the work. • Licensed Contractor to obtain all permits as necessary from all Local, State, and Federal agencies. • Aluminum: Material 6061 T6 Aluminum, all welds are min. 4" full fillet weld using 5556 filler alloy, all welding must conform to AISC steel construction manual 14th ED as inspected and verified by others. The contractor is responsible to insulate aluminum members from dissimilar metals to prevent electrolysis. • Aluminum members in contact with concrete and wood shall be protected by "Koppers Bituminous Paint" or Polyethylene Tape UHMW (ultra high molecular weight). 11.7 mils (0.30 mm) min. total thickness in accordance with current Florida Building Code. • All anchors to be Hilti Brand or Approved Equal. 'All bolts shall be hot dipped galvanized or stainless steel & meet the requirements of ASTM A304 with hardened washers and hex nuts. Washers shall be used between wood & bolt head & between wood & nut. Where generic fasteners are labeled in details, capacities shall be equal to or greater than Hilti Kwik Bolt 11 or Red Head thru bolts SAE Grade 5 or better. Embedment depths specified herein are depths into solid substrate and do not included thickness of other finishes. • MW Engineering has no control of the manufacturing, performance or installation of this product. These generic plans were engineered in accordance with accepted engineering practices and data provided by the manufacturer. Piles shall be driven to refusal and sufficiently penetrated into sand or rock strata to support lift capacity, weight and loads. • Each pile to carry commensurate Igad I.E. 1/4th lift capacity for 4—post lift (Factor of Safety of 1.5) • Allowable minimum compression pile capacity of 5 tons. • The contractor of record shall verify pile type, installation and driving in compliance with FBC 6th ED (2017) • Sub —surface conditions can vary greatly. Proposed 4 - Post Boat Lifts 4,500 Ib to 2 4,000Ib NEPTUNE BOAT LIFTS 228 SW'21 Terrace Fort Lauderdale, Florida 33312 Phone:954-524-3616 Fax: 954-524-3604 'LALz 32 DATE: 05.12.2015 DRAWN BY: WRT CHECKED BY: WM JOB No: Elevotor' 32.dwg Sheet 1 of 3