HomeMy WebLinkAboutSEWAGESCANNED
BY
a. WOW County
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL
r�s Qi SYSTEM
CONSTRU ION PERMIT FOR: OSTDS Repair
APPLIC �T: Jose Torres
PROPERTII ADDRESS: 4966 Deanna Ln Fort Pierce, FL 34946
LOT: 311 BLOCK: 3 SUBDIVISION: Green Acres
1430-702-0019-000-5
PERMIT #: 56-SF-1 846322
APPLICATION #:AP1343948
DATE PAID:
FEE PAID:
RECEIPT #:
DOCUMENT #: PR1117228
[SECTION, TOWNSHIP, RANGE, PARCEL NUMBER]
[OR TAX ID NUMBER]
SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION
381.006i, F.S., AND', CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL. OF SYSTEM DOES NOT GUARANTEE
SATISFAI'I��TORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS,
WHICH 13ERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE
PERMIT I1APPLICATION. SUCH 'MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID.
ISSUANCIII OF THIS PERMIT DOES •NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL,
STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND SPECIFICATIONS
T
00 )
GALLONS / GPD SeDtic New
CAPACITY
A [
0 ]
GALLONS / GPD
CAPACITY
N (
0 ]
GALLONS GREASE INTERCEPTOR CAPACITY
(MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K [
]
GALLONS DOSING TANK CAPACITY [
]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ]
D [
R [
A TYPE
I CONE
N
F LOCA'
I ELEV�
E BOTTi
L
D FILL
100 ] SQUARE FEET Drainfield New SYSTEM
O ] SQUARE FEET SYSTEM
5 STEM: [X] STANDARD j ] FILLED [] MOUND [ ]
,;URATION: [ ] TRENCH [X] BED [ ]
=ON OF BENCHMARK: Crown of Road
P,iISON OF PROPOSED SYSTEM SITE [ 5.00 ][ INCHES FT ][ABOVE BELOW) BENCHMARK/REFERENCE POINT
y OF DRAINFIELD TO BE t 11.00](INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT
IRED: [ 2.00] INCHES EXCAVATION REQUIRED: [ ] INCHES
n is sized for 2 bedrooms with a maximum occupancy of 4 persons (2 per bedroom), for a total estimated flow of
200 gad.
T The licensed contractor installing. the system is responsible for installing the minimum category of tank in accordance with
H s. 646- 6.013(3)(f), FAG. Required drainfield area based on rule 64E-6.015(6)(c)2.
Install new drainfield to achieve Drainfield size requirement.
E Havel he tank abandoned in accordance with the following procedures:(a) The tank shall be pumped out.( (Comments
R Conti' Rued on Page 2.)
SPECIFICATIONS BY: Jason Harri's'I - TITLE: Septic Tank Contractor
APPROVE BY: TITLE: Environmental Specialist I St. Lucie CHD
Dianna S May
DATE IS UED : 05/16/2018
11
DH 4016;108109 (Obsoletes all previous editions which may not be used)
Incorporl1lted: 64E-6.003, FAC
i
EXPIRATION DATE: 08/14/2018
S210969,Yo ti