HomeMy WebLinkAboutCERTIFICATE FOR DESIGN LOAD COMPLIANCE•_a,
i SCANNED
BY Planning & Development Services Department
ORO Building & Code Regulations Division ILE Co.
2300 Virginia Avenue, Fort Pierce, FL34982 (772) 462-3553
Certification for Design Load Compliance
IProject Name*. lo!°t,'4 57
Project Address•
C
Permit #: Occupancy Type: ��Construction Type:
I.NM DONS FOR USE:
This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or mufti -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
" Note: Form not required for Interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local buildMg offidal; Contact the # above for questions.
__ .._...MIJERS erdn ecel,MpUg" u� SED: (complete all that apply) .
1. 'DESIGN CODE: Florida i Code 2010 Edition with 20 -. Supplements using ASCE 7-10
Enclosed � Partially Enclosed Opyn
i 2. Structure Designed as (Check one):
3. Risk Category: 1 1ll iV Exposure Category:
4. Design Wind Velocity ._.mph •,_ASD LRFD :. End Zone Width:
5. Mean Roof Height 2
ft .. Roof Pitch: _ ;:12 Parapet: _-= ft
6. Components & Cladding Design Pressures Used: (PSF based on WSWIMK Clem label on all plan openings):
p
Zone 1:+� Zone 2: + Zone 3: Zone'4i yc� Zone S:'^�.4 Garage:
—'_ `�"�-- PSF
7. Design Loads: Floor: ' < .PSF Roof/Dead: g-� -- PSF :Roof/Live:_y balcony: �._
PSF Deck: Psi Stairs: PSF Fence: ,;PSF Railings: 2�PSF
Dock.,..-_ s I :
g. Were Shear Walls Considered For Structure? Yes __, ,Not Applicable Explain Why Not:
I
9. Is A Continuous load Path Provided? Yes Not Applicable . Explain Why Not.
10. Design Soil Bearing Pressure: Z,_ �C> PSF Solt Test Reports Submitted? . Yes
0 IGN PROFEStONAL CERTIFISOON STATEMENT:
' 1 certify that; to the best of my knowledge and belief, the attached plans &specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that. structural elements depicted on these plans provide adequate resistance to the design
l I forces specified: 2-
A v-10-
' 77 Print Na a Cert & Co. Cert Auth.
±l.._.
I "and'Seal,
SlCompany Name &Address
SLCCDV Form p 020-12 Revised 3/1S/12 (JS) .
I
�II