Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE __ SCANNED _ Q BY 1 UCIE)C00 a'nning&Development Services Department Building&Code Regulations Division -- 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553 Certification for Design Load Compliance Project Name: Queen Island Preserve Lot 5 Single FamikResidence +Project Address: 4434 Al(North Hutchinson Island); Fort Pierce, Florida 34949 Permit#: Occupancy Type: R-3 Construction Type:Type Vb INSTRUCTIONS FOR USE: ESS • This certification must be completed,signed,and sealed by Ion p ING • Submit(2)copies for residential, (3)copies,for commercial p r Rdt1' plfcA ' sill ��ing: o New Residences(single or multi-family) OF 5 , .. EIdINGS R + F E . ' o Residential Addition ' N BE T 24' ,OR 20'W o Any accessory structure requiring a building perm SIl L Ri 4 4' ABO-vt FLOOR. o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as(check one): X Enclosed Partially Enclosed Open 3. Risk Category: X I II III IV Exposure Category: B C X D 4. Design Wind Velocity 160 Vult mph X ASD LRFD End Zone Width: 5.1 ft. 5. Mean Roof Height- 30• ft Roof Pitch: 4 :12 Parapet: N/A ft 6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings): Zone 1:42.0 Zone 2: 73•0 Zone 3: 108.0 Zone 4:49•7 Zone 5:61.4 Garage: N/A 7. Design Loads: Floor: 55 PSF Roof/Dead: 25 PSF Roof/Live: 20 Balcony: 100 PSF Dock: N/A PSF Deck: 100 PSF Stairs: 60 PSF Fence: N/A PSF Railings: 200 PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief,the attached plans &specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: David S. Knight, P.E. 41060 SEP7 1 20 1-5 Print Name Cert#&Co.Cert Auth. Knight McGuire &Associates, Inc. ib I - h, FL Palm Pointe Suite 401; Vero Beach, 3 6 Signature, Date,and Seal 80 Royal __ ...� Company Name&Address Revised 07/25/2014 '�