Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT REVIEW AFFIDAVIT
QUEEN'S ISLAND PRESERVE LOT 5 Building Permit ## Planning. & Development Services Department Building & Regulations Division Product Review Affidavit Owners Name Applicant: Product Opening"Design Product Rated. Manufacturer Model Number Product Approval Glass Method of AttachRK Pressures Design Pressure Number T e +46/-62 PSF +80/-80 PSF CGI SENTINEL 110' NOA 14-0915.06 B1 1/4" ELCO ULTRACON 1lVindows +44/-57 PSF +66 PSF CGI CLIPPED NOA 12-1220.15 N/A 1/4" ELCO ULTRACON 1: Mullions +46/-62 PSF +801-80 PSF CGI SENTINEL 130 . NOA-13-0502.03 B1 1/4" ELCO ULTRACON Fixed Glass . Block Glass N/A Skylights N/A 'Sliding Glass Doors +40/49 PSF +80/-80 PSF CGI SENTINEL 150 NOA 14-067.15 61 1/4" ELCO ULTRACON +44/-57 PSF +65/-65 PSF THERMATRU SMOOTH STAR FL15225-Rl N/A 1/4" 1TW SCREWS TO CONCRETE Swing Type Doors +42/46 PSF +80/-80 PSF CGI SENTINEL 160 NOA 14-1117.05 131 1/4" ELCO ULTRACON French Doors Garage Doors +40/44 PSF +56/-64 PSF DAB 8241811 NOA 15-0304.02 N/A 5/16" x 1 5/8" hex head lag screw (aD_ 11" o/c Hurricane Protection N/A Roof Ventilation N/A ikoofing.Materiat -108 PSF -189 PSF SUNLAST METAL, INC. 5V METAL NOA 12-1009.01 N/A #14 HEX -HEAD WOOD SCREW w/ NEOPRENE WASHER SCREWED TO PLYWOOD DECK SPACING @ ;:a ROOF 12" O.C., ROW SPACING 16" O.C. F have reviewed the above components .or cladding and.I have approved their use in this. structure. These products pr'ovide'adequate resistance to the wind loads and forces specified by current code provisions. NAme RANDALL STOFFT Signature: seax , Design Prof: ARCHITECT Cert. No. FL-0011105 Date: 8/3/2015