Loading...
HomeMy WebLinkAboutSET-UP MANUALSCANNED S . Luc1s COU0j SET-UP MANUAL F-1011 I jAqOBS N HOMES 600 PACKARD COURT SAFETY HARBOR, FLORIDA 34695 (727) 726-1138 NOTICE These specifications and drawing are original, proprietary, and confidential materials of Jacobsen Manufacturing, Inc. Such materials are provided to the recipient for specific purposes and must be kept confidential and secret from others, SU-00-0000 6/1 /07 MANUFACTURED HOME SET-UP *SITE PREPARATION (A.) BLOCKING (B.) LEVELING (C.) ASSEMBLY AND CLOSE—UP *TIEDOWNS (SEE SET—UP MANUAL ADDENDUM) *ELECTRICAL CONNECTIONS *PLUMBING CONNECTIONS *A.C. CONNECTIONS *ON SITE VENT CONNECTIONS *MISCELLANEOUS DETAILS APPROVED BY Revised Nov 28,2006 FEDERAL WWUFACTURID HOME I;' CONSTRUCTION AND SAFETY STANDARDS IF YOU ARE GOING TO LIVE IN A PARK, YOUR HOME SITE WILL BE READY OR BE PREPARED FOR YOUR HOME IF YOU INTEND TO INSTALL YOUR HOME ON YOUR OWN LOT (NOT IN A PARK), SOME SITE PREPARATION WILL BE NECESSARY. THE SITE MUST BE GRADED TO PROVIDE FOR STORM RUN—OFF. SPECIAL CARE MUST BE TAKEN WITH THE AREA DIRECTLY BELOW YOUR HOME TO PREVENT WATER FROM PONDING AND/O PUDDLING UNDER YOUR HOME AND SUPPORTS. IT IS HIGHLY RECOMMENDED THAT THE GROUND E COVERED WITH A VAPOR BARRIER (I.E. VISQUEEN, ROOFING UNDERLAYMENT). PIER SUPPORTS MUST BE PLACED ON UNDISTURBED SOIL (ALL GRASS AND ORGANIC MATERI MUST BE REMOVED) OR FILL WHICH IS COMPACTED OR FULLY SETTLED (SEE SU-4.1, DETAIL 'A' AND DETAIL 'B'). IN AREAS THAT ARE SUSCEPTIBLE TO FROST, PIER SUPPORTS MUST BE BELOW THE FROST LINE. OPTIONAL: PIERS MAY BE PLACED ON CONCRETE RIBBONS 4" X 16" X LENGTH OF HOME MINUS 18", REINFORCED WITH WELDED WARE MESH. (A.) BLOCKING UNUKE A STANDARD HOUSE, YOUR MANUFACTURED HOUSE DOES NOT NEED A FOUNDATION TO SUPPORT IT.COMPLETELY AROUND ITS PERIMETER. THE STEEL FRAME OR CHASSIS USED FOR TRANSPORTATION ALSO SUPPORTS THE HOME AT ITS HOME SITE. THE STEEL FRAME MUST BE SUPPORTED (SEE SU-01-0003 & 0004) TO PREVENT YOUR HOME FROM SAGGING, AND TO KEEP IT LEVEL. NOTE: ADDITIONAL PIERS ARE REQUIRED AT ALL RIDGE BEAM SUPPORT COLUMNS (EXCE AT THE FRAME HEADER), SHEARWALLS, .AND AROUND - THE PERIMETER OF YOUR HOME. CHECK F01 THE APPROPRIATE DETAILS FOUND IN THIS AND THE SET—UP MANUAL ADDENDUM FOR SPECIFICSI FOR EACH TYPE OF ADDITIONAL BLOCKING REQUIRED. SPECIFIC BLOCKING LABELS ARE FOUND ON THE EXTERIOR SIDES OF YOUR HOME. MAXIMUM HEIGHT OF A PIER IS DETERMINED BY THE TYPE OF PIER USED, CHECK THE APPROPRIATE DETAILS FOR THE PROPER CONSTRUCTION OF EACH DIFFERENT TYPE OF PIER. (ALSO SEE TIE —DOWN REQUIREMENTS TO DETERMINE MAXIMUM HEIGHT FROM GROUND.) ALL SUPPORTING STRUCTURES NOT LISTED OR SHOWN IN THIS MANUAL OR SET—UP MANUAL ADDENDUM MUST BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER. II (B.) LEVELING PROPER BLOCKING SEQUENCE IS ESSENTIAL IN THE LEVELING OF YOUR HOME. (SEE BLOCKING DETAILS ON SU-01-0002 .0003, do 0004) FOR THE RECOMMENDED BLOCKING SEQUENCE, TAKING CARE TO CHECK YOUR LEVEL BETWEEN EACH STEP AND SUPPORT. RECOMMENDED LEVEL IS A 48" CARPENTER'S LEVEL. (SEE ACCEPTABLE . LEVELING GUIDE BELOW) eUBeLE HAIRUNES IS CARPENTER'S LEVEL 1A CCEPTABLE AMMUM II SPECIAL NOTE FOR ALL HOMES SET IN FLORIDA CHECK FLORIDA STATUTE 15C FOR ANY UMITAIONS THAT MAY AFFECT THESE INSTRUCTIONS. NM AAM DRAMN BY: JACOBSEN HOMES DAZE REv LlTIFR „� srECF1cA1IaIs au„wcS,wE M.T. 11-21-06 I it UMUL• MaMMY AM oaN WM& MAVMWG IRE P.O. BOX 368 YATOWS OF JACOEM UWACUMM H SAFETY HARBOR, FLORIDA 34895 MW � gT� q� � WW BE MN FACIUREO HOME SET—UP PHONE (727) 726-1138 KEPT mIFICEIRK me gnu Ftmll Omm $U-Oi —0001 MAIN PR I -BEAM S (DECAY RESISTANT) AND/OR TREATED LUMBER PIER MAPPED WITH SOLJD CONCRETE----' BLOCK�,I(MIN. 4' THICK) 8 X �j X 16 2CELLED MASONRY BLOCKS WITH OPEN CELLS VERTICAL SEE Tj SIZING (SEE REMOVE AND PLC BELOW I CODE RI E I FOR- PIER FOOTER ID SPACING IONS (PAGE 11) 4A FOR 16 X 16 PIER PAD SPACING), TIE -DOWN TO RIDGE EACH SEC TO A DOU SEE NOTE DOUBLE NOTE ORGANIC MATERIAL - PAD ON STABLE SOIL T LINE PER LOCAL APS ATTACHED I COLUMNS ON TO BE CONNECTED HEADED ANCHOR SEE NOTE J2 J DETAIL 'A' DETAIL 'B'. 1. 48' MAX. FOR HOLLOW BLOCKS, 72' MAX. PIER BLOCK WITH CELLS COMPLETELY FILLED WITH CONCRETE (PIER SYSTEMS ANY TALLER MUST BE APPROVED BY A LICENSED ARCHITECT OR ENGINEER) 2. MAXIMUM PIER/PAD EXPOSURE: 1000 PSF SOIL — 8' 1500 PSF SOIL — 6 3/4' 2000 PSF SOIL — 5 3/4' 2500 PSF SOIL — 3 3/4' 3. MARRIAGE WALL OPENING PIERS TO BE WITHIN 6' OF OPENING ON E 7HER SIDE OF COLUMN. 4. MINIMUM PIER PAD THICKNESS: A. 4' MIN. FOR PRECAST UNITS UP TO 16" X 16" B. FOR CAST IN PLACE FOOTINGS MIN. THICKNESS IS MAX. FOOTING DIMENSION DIVIDED BY 4. (BUT NOT LESS THAN 4') 5. ALL FOOTING CONCRETE.TO HAVE COMPRESSIVE STRENGTH. (fc') 0 3000 PSI (MIN.) 6. PLACE 4 MIL POLY ON GROUND PRIOR TO POURING FOOTING CONCRETE 7. ALL PIERS MUST BE CENTERED ON FOOnNG. 8. FOOTING CONSTRUCTION MUST COMPLY TO LOCAL BUILDING CODES. SEE NOTE 12 owl I No ,TC'-� 3 1994 INC WOOD SHIMS (DECAY RESISTANT) AND/OR PRESSURE TREATED LUMBER PIER CAPPED WITH SOLID CONCRETE BLOCK (MIN. 4' THICK) 8' X 8' X 16' CELLED MASONRY BLOCKS WITH OPEN CELLS VERTICAL (SEE NOTE 11 FOR MAX. PIER HEIGHTS AND DETAIL ABOVE) SEE TABLE FOR PIER FOOTER SIZING AND SPACING SPECIFICATIONS (PAGE 10) REMOVE ALL ORGANIC MATERIAL AND PLACE PAD ON STABLE SOIL BELOW FROST LINE PER LOCAL CODE REQUIREMENTS -.--SEE NOTE 12 (DIMENSION VARIES WITH MA)C ALLOWABLE SOIL BEARING) su-a-�d,1 REV. 9-7-93 SU-4.1 MOBILE HOME SET-UP NOTES: 1. JACKS TO BE RATED AT 5 TONS. 2. ALWAYS USE A SUPPORT UNDER JACKS. 3. FOLLOW BLOCKING INSTRUCTIONS. 4. FOR MULTIPLE WIDES SET HEAVY SECTION FIRST. BLOCKING SEQUENCE 1 2 3 4. 5. 6. 7. 8. 9. 10 11. LOCATE HOME ON SITE AND LEVEL AS CLOSE AS POSSIBLE USING HITCH JACK. SET SUPPORTS (BLOCKS #1) UNDER BOTH I -BEAMS JUST FORWARD OF THE FRONT SPRING HANGERS. SET SUPPORTS (BLOCKS #2) UNDER BOTH I -BEAMS JUST BEHIND THE REAR SPRING HANGERS. LOCATE SUPPORTS (BLOCKS #3) APPROXIMATELY 24" BEHIND THE FRONT CROSSMEMBER. LOCATE SUPPORTS (BLOCKS #4) APPROXIMATELY 24" FROM THE END OF THE HOME. ADDITIONAL SUPPORTS (BLOCKS #5) MAY BE NECESSARY BETWEEN 1 & 3 AND 2 & 4, IF THEY ARE NEEDED THEY SHOULD BE SPACED EQUALLY, MAXIMUM SPACING 10'-0". IF YOUR HOME HAS 4 AXLES ADD BLOCKING BETWEEN THE MIDDLE SET OF AXLES. FOR SINGLE WIDES BLOCKING IS COMPLETE. FOR MULTIPLE WIDES REMOVE ALL SHIPPING BATTENS AND VISQUEEN AND SET LIGHT SECTION(S) AS CLOSE AS POSSIBLE TO THE ALREADY SET HEAVY SECTION. JACK THE LIGHT SECTIONS) TO THE HEAVY SECTION USING JACKS AND COME-ALONGS. FOLLOW BLOCKING SEQUENCES 1 THRU 7. NOTE: PERIODIC RELEVELING MAY BE NECESSARY BECAUSE OF THE WEIGHT OF THE HOME AND SETTLING THAT MAY OCCUR. NOTICE: DRAWN BY: S.A. DATE: 6-6-9 li REV. LETTER: ❑❑❑❑ JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWINGS ARE ❑❑■❑ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING "T ' OBILE HOME SET-UP #211 ❑„� P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE �I ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: I SU-01-000��, SEE NOTE #7 SEE NOTE #6 2 1 3 I NOTE #5 SEE NOTE 3 I i SEE NOTE #2 I >_ .-SEE NOTE #4 --, NOTE #5 - I NOTE #1 I SEE NOTE 3 4 2 1 NOTE #6 5 5 3 TYPICAL TRIPLE WIDE BLOCKING SEE NOTE #7 NOTES #1-MAIN FRAME I -BEAMS #2-LOCATE PIERS UNDER FRAME I -BEAMS #3-LOCATE PIERS UNDER CLOSEST FLOOR JOIST EACH SIDE OF OPENINGS 48" AND LARGER. (I.E.-RECESSED ENTRIES AND SL. GL. DRS.) SEE TABLE FOR PIER FOOTER SIZING PAGE 10. #4-LOCATE PIERS UNDER MARRIAGE WALL PERIMETER JOISTS WITHIN 6" OF EACH SIDE OF OPENINGS. 48" & LARGER AND RIDGE BEAM COLUMNS. SEE TABLE FOR PIER FOOTER SIZING SU-01-0030 AND SEE DETAIL 'B', SU-01-0010. #5-AXLE ASSEMBLY CENTER LINE #6-SEE TABLE I FOR PIER FOOTER SIZING AND PIER SPACING INFORMATION SU-01-0040, AND DETAIL 'A' SU-01-0010. #7-BLOCKING SEQUENCE NUMBERS, SEE SU-01-0002 FOR PROPER BLOCKING PROCEDURES. i. I' I ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: DATE: I REV. LETTER: S.A. 6-6-94 ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE: TRIPLE WIDE BLOCKING ❑„❑ ❑❑❑❑ P.O. BOX 36B SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 INC. SUCH MATERIALS ARE PROVIDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS DRAWING NUMBER: SU-01 -0004I I� ADDITIONAL PERIMETER BLOCKING (THIS BLOCKING IS IH ADDITION TO BLOCKING REQUIRED IN NS MANUAL) FIREPLACES ON SIDEWALL OR MANAGE WALL Ili 54'• OR 60' TUB AT SIDEWALL OR MARRIAGE WALL UNDER EACH SIDE OF ALL DaER10\DOORS LOCATED,ON SIDEWALLS 2 OR MORE 46 1/2' WNDOWS PIERS REQUIRED AT EACH END AND BETWEEN EACH OPENING RECESSED AREAS REQUIRE PIERS SPACED 64' O.G MAIL (18' OR LESS IN DEPTH) EACH END OF RECESSED AREAS RECESSID AREAS W/SDE BAY REQUIRE PIERS SPACED 64' O.0 MAX. THIS ALSO APPLIES TO ALL ENDWALL BAY WNDOWS UNLESS SUPPORTED BY A FRAME MEMBER GARDEN TUB AT SIDEWALL OR MANAGE WALL . 64' O.C. MAX. . -------�-- ---- iuui-------- CABINETS ALONG SIDEWALL OR MARRIAGE WALL (APPLIES 10 BAIN CABINETS 80' OR GREATER IN LENGIH) (SAYE BLOGONG MAY BE USED FOR MULTIPLE 461/r WNDOWS) I I SPECIAL BLOCKING NOTE FOR 15'-e (184°) WIDE FLOOR SECTIONS APPROVED BY PERIMETER BLOCIONG IS REQUIRED (MARRIAGE AND SIDEWALLS) 64' ON CENTER MAX SPACINGON NOTE LEVEL FLOOR SYSTEM FIRST (SIDET4ALLTO MALL OR MARRIAGE WALL) BEFORE INSTALLING PER6BETER BLOCKS reap 22,2006 NOTES14INC. 1. ADO 4 MOO= REQURED AS DXIICATED ABOVE (USE IC X 16' PIER PADS FEDEW MMUFA DROME 2 LOCATE OCJONfa UNDER PFA61E1ER JOIST OR WOIW W OF END OF 16' O.G J=M CDMSTItlIGT10X rwD SAFETY STANDARDS 1 FERN IBLW04 IS REQUIRED UNDER TLE FLOORS QA MMX h SMIU LS) Se O.C. UAL MEmEpI, JACOBSEN HOMES ff-sE U1CA7N1n lY O DMWM AK DRAWN BY: M.T DATE: 4-12-00 LErtLx it ORMAI. PROF` MY. AND WfioExnAL DRAWING TITLE: P.O. BOX 368 W►maALS OF JAODBN UNWACRAM ADDITIONAL BLOCKING SAFETY HARBOR. FLORVA 34695 W r FOR � ply AHD L M BEBE DRAWWG NUNOERI A PHONE (813) 726-1135 WT OD:f10E1 K AM swo fm OTM QI I—nl —nMr, BLOCKING (PIER) LABELS LOCATE THESE LABELS AND CHECK THE APPROPRIATE MANUAL FOR PROPER INSTALLATION OF BLOCKING AND PIERS.. SHEARWALL LUMN PIER PIER OCATION ZSEE LOCATIONS ET —UP MANUALSEE SET—UP ADDENDUM SPECIFICS R SPECIFICSFOR MARRIAGE UNE)PIERS AT BOTTOM OF EXTERIOR SIDING AT SIDEWALL SPECIFIC PERIMETER PIER LOCATION SEE SET—UP MANUAL N, FOR SPECIFICS i \/ BOTTOM OF EXTERIOR SIDING AT SIDEWALL GENERAL PERIMETER BLOCKING 64" O.C. MAX. (SEE SET —MANUAL FOR SPECIFICS) NOTES '" " " ""."•. 1. THIS IS INCLUDED IN THE HOME OWNERS PACKAGE. APPROVED BY INMay 22,2006 174NC. FEDERAL MANUFACTURED HOME CONSTTUICTION AND SAFET STANDARDS JACOBSEN HOMES NOTI= DRAWN Br DATE 1 Rf11 TNESE sPECi1C mm me DR wmm pmM.T. 05-20-06 °A J=MARY M COFMOMAL yMFAC111 M DH1� 'BLOCKING (PIER) LABELS ' P.O. BOX 368 M 2= MATERIALS ARE PWAn TO THE SAFETY HARBOR, FLORIDA 34695 RF SW FER 9EDIN p1rM AM) UM BE DRAYANG NUMBER: PHONE (727) 726-1138 WT CMEDIM AID WW FRAY CUM SU-01-0006 I ADDITIONAL RECESSED PORCH BLOCKING (INS Own Is N ADDmm 10 aL e c REOLJIn LK TIBS "UK) I • I 81' MAX 61' MAX USE DETAIL t;' OIQY we i OUiRIm is ON FLOOR JOIST ` SEE DUAL 'A' SEE ma - dRECiIY UNDER PORCH POST 1---------------- - -- .'81-------r n Al J . � m II �� W. RECESSED PORCH - wu Ix>� l J WALL ADDED -DEAU.UNDER am0WALL-- -- -- - - - - put U ADDED !-lLJ� U! RECESSED PORCH REMK PERS SPACED 64' QC' YAX �C FM AT PORCH POSTS) AS SHOWN ocR Duo DEB I -EAU fir 0.c. MAX PIER SPACING AT VARMAGEWALL WE- US AHCE IUW EDCE OF ` PIER AND FOGS OF PORCH POST MAY NOT EXCEED DEPTH. OF 1YP. PORCH POST .PORCH POST FLOOR JOIST (51CY) TYPJ FLOORING 51 2' MAX TYP. POROI FLO' OidNGiPORCLI . ~� PORCH FLOOR JOIST PORCH FLOOR JOIST it OOUIIIE P� PERI1ETt7t RAIL � �� (2) 2 X 6 PT X f1' W. DOUBLE PORCH PER110:1ER RALrV. 6 P� TAX 1!�YN. T)P. 1fE-DOWEL STRAP FJRDCED BEiWFEN 2 TIP. IE-DOVIN SWIPRCH BR RMCED FLODrt JOlS1T OfIR DETAILS) PORCH fL00R JOISR (� DTHER OETALS)UP.PiER(8'XWX16') (8'X8'X161 16' 16 WN PAD 16' X 16' UK PIER PAD .� SS SECTION VIEW At j CROSS SECTION VIEW Bl TV. PORCH POST `PORCH TYP. PORCH POST To. PORCH FLOORING �i �NDX' DISTANCE Li IVEE L EDGE OF PIER M EDGE OF PCRCFI POST TYP FLOORING ;51/2 _ PORCH BOOR ,fast PORCH FLOOR JOIST MAY NOT E1(IiED 5 1/2' (2) 2 X 6 PT X 187•10L (2) 2 X 8 PT X leMBL� BOM F2 TIP. lE-OOYbI SiRAP (SEE DIETER DETARSj 'I PORCH BOOR JUST3 P� LOOR JOlS7T i LONGITUDINAL VIEW A2 LONGITUDINAL. VIEW B2 • ,� DAPDI A"Raft NOTES: ' '�• •:IM�,� r •. c �. LL A0a jI BLDCXING REOIAAED AS NO IM ABOVE (USE IC X 16' PO + : G..t:; 1. APPROVED BY .. .0 PADS ON 1,000 PSF SOL CAPACITO " 0. r. 2 LOCALE ow PERIMETER JIM OR WINS! s 1/2r OF END OF IC 0C IN Dec 13,2006 1 PER6FE1fR �I� a REQURED UNDER PM AT EACH POST (61- Oit UAX) : I Z I Q 4 PlINC, {. (W �I8�0faN REQ>tIED AS INDICATED AM UHOER C2ITER OF ADDED 1-BEAI1 ; ; � s v 1� (� w FEDERAL NANUFAM EO HOME (6i QC ) I • • �. WNSTRUCRON AND SAFETY STANOARDS S SEE 010QDETAI S FOR OUR REQUIRED BLOOM LOCA110NS �'� :, : o Tjlo4 .�• �1 �. 6 ADDED , AT PORGI/iXIf W WALL MAY DIFFER 01 SZE FROM MAIN HODS£ I-BEAx' ,f/sT�`��L7 ;t '�40 ` �• L w III NOTICR =: m vy: CAM BEY. LETTER JACOBSEN HOMES IMM S T"AM Afa R.R. 11-28-66 °aia'"E• PAWRUAM A10 °°"FToo' 4 AMN HILE AMTIONAL RECESSED P.O. BOX 359 T jff wpm i0 m PORCH BLOCKINGLiNgLi '— SAFETY HARBOR. FLORP)A 3"95 AlMM M SM914JUM NO LUST Ef DRAVA NUMBER: PHONE (813) 726=113e an 000mmu m xw FRa ones SU-01-0007 I - 6� ATTACHMENT TO HOST BEAM ATTACHMENT MAY BE FLUSH WITH HOUSE -� _ - HOST BEAM STRUCTURE ATTACHMENT SECURED DIRECTLY TO FACTORY INSTALLED HOST BEAM (THIS IS IN LIEU OF "FOURTH WALL CONSTAUCTION") STRUCTURE ATTACHMENT INSTALLED ON -SITE BY OTHERS -AND MUST MEET LOCAL CODES PERIMETER BLOCKING ON -SITE 48" O.C. MAX. DESIGN MEETS FBC AND ASCE FOR 140MPH (3 SEC. GUSTS) EXP. B LOADING FOR PPR.TIALLY ENCLOSED STRUCTURES REF. PG. 07-0050, 07-0051 N D S01 RU. `ALA NOTES �- LAPP `9�lIJ. 119`,t 1. HOST BEAM INSTALLATION IS FOR ON -SITE STRUCTURE ATTACHMENT: ; : �; `, ��i;Ii=lC_; .•�; .mot, 20' WIDE MAX 00 ZONE 2 OR 12)MPH EXP. B SITES, �'� • `� `t> ; t 16' WIDE MAX WIND ZONE 3 OR 14OMPH EV. B SITES 2. MIN. BRACKET LOAD CAPACITY FOR VERTICAL PE -DOWNS IS 24501 WIND ZONE 2, 29601 WIND ZONE 3 3. WALL FRAMING IS 2 X 6 SPF 13 16 O.C. .• `' t3F p :. Q �(�j•�'c`04`r���`` 4. 48, O.C. PERIMETER BLOCKING REOLIRED ON HOST BEAM SIDE OF HOUSE A ISO MEETS YANDZONE • 111 EXPOSURE C 20 PSF ROOF 10 PSF D.L APPROVED BY Jan 20,200NJ - INC. FEDERAL MANUFACTURED�HOME CONSTRUCTION AND SAF TYSTANDARDS NOTICE: tt y; t Y. D.M.T. DA1'e 01-10-07 LETTER JACOBSEN HOMES n-m sPET ICATMS At0) DRAMS11�` + ORI=AI, PROPRIETARY. AND COWIDEHTIAL DRANNIG IIU- P.o Box 368 MA70UM OF JACOBSEN MANUFACTURING ATT. TO HOST BEAM W_ SOQI MATEIR" AK FROMM*TO THE SAFETY HARBOR. FLORIDA 34695 RECMI tot STECFIO PIR8M AND 9W RE DRAVANG NUMBER: PHONE (727) 726-1138 KEPT COMOOML AMD SECRET FROM aOaTts. SU-01-MOB III ' I V ` 16" X 16" PIER FOOTER SPACINGS* f I MAXIMUM I -BEAM PIER SPACING I FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) { WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR 39" 62" 86" 110" 134" 157" 1�4" WIDE FLOOR 33" 53" 73" 93" 113" j 133" 1110" WIDE FLOOR 30" 48" 66" 85" 103" 121" 184" WIDE FLOOR 26" 42" 58" 74" 90" 107" MIi PIER CAPACITY 1778 LBS. 2667 LBS. 3556 LBS. 4444 LBS. 5333 LBS. 6222 LBS. II NOTE: ALL UNIT WIDTHS INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. l 4" MINIMUM, AND/OR PER LOCAL CODE REQUIREMENTS 4„TYP ji 7" OR 8" 30• MAX TYP (TYP) Q Q NOMINAL 16" X 16" SQUARE PRECAST 1 CONCRETE FOOTING 16 MIN.led10. EACH SIDE 4 X 8 X 8 SOLID 6 X 7 X 8 SOLID FOOTING CONC. BLOCKS CONC. BLOCKS TYPICAL PIER FOOTER TYPICAL PIER CONFIGURATIONS (THE CAPACITY OF THESE PIERS EXCEEDS MIN. REQUIRED, I IONCRETE NOTES it WINDZONE III ALL FOOTINGS CONCRETE TO HAVE fc' = 3000 PSI MIN AT 28 DAYS; (110 MPH) t ALL SOLID CONCRETE BLOCKS TO HAVE fm' = 1500 PSI MIN; ALL EXPOSURES 31 20 CENTER ALL PIERS ON FOOTINGS PSF ROOF I 10 PSF D.L. ` REF. CALCS. c G•V A- — v � O( � �p11U1I I IIIII p// NOTE: �I EN '! . • • �(• ''• ��'4 DAPIA APPROVAL 1. REFEf1 TO OTHER DETAILS FOR ADDITIONAL PIER FOOTER SIZES AND .���(�Q.•G\STEji'•.�l �� � No. �O •.• r APPROVED EY SPA GS. 2. STARTIII-BEAM PIER SPACING 1/2 THE ALLOWABLE SPACING FROM EACH END 910334 •� OF 14E HOME AT EACH I -BEAM, AND MAXIMUM SPACING SHOWN IN THE CHART �c� •%C - ABO IIFOR FULL LENGTH of HOME. -o ; STATE OF t� �': 14 INC. 3. SEE 07HER DETAILS FOR PIER REQUIREMENTS AND MAXIMUM OPENINGS AT 11IN LINE OF MULTIPLE WOE HOMES. ��I Q;.' ���� ••" �ry A �� �� 'i�tS'�j' • FEDERAL MANUFACTURED HOME CONSTRUCTIQIINI�SgFE1Y STAGpAROS 4. SEE O ER DETAILS FOR TIE -DOWN REQUIREMENTS. . lii JACOBSEN HOMES THESE SPEanCATI I w AWN 8Y: M.T. DATE 2-8-99 P.O. BOX 368 ORWAL• PROPPoETARY, AND CONFIDENnAL MATERIALS OF JACOOSEN MANUFACTURING INC. SUCH MATEIUALS ARE PROVIDED TO THE f LF JS DRAWING MU- „ , 16 x 16 " PIER SPACING n SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 FIECRENT FDR SPECETC PURT'OSES AND MUST SE WT CONROCNTUL MD SECRET FROM OTHERS. DRAWING NUMBER: SU-01-0020 ALTERNATE MAIN BEAM PIERS (8' X 8" X 16- HOLLOW CONCRETE MASONRY BLOCKS) (NO MORTAR OR GROUT REQUIRED) MAIN FRAME I-BEAM��� �'•• WOOD SHIMS (DECAY RESISTANT) AND/OR 8" X 8" X 16' HOLLOW CONCRETE BLOCK IS SHOWN, �" . BUT A 8" X 4• X 16" BLOCK SOLID OR HOLLOW CORE PRESSURE TREATED LUMBER USED FOR ( ) HEIGHT ADJUSTMENT, 1' MAX. THICK.,, OR A 1' TO 2' X B' X 16' SOLID BLOCK MAY BE USED. AND 4" X 8' MINUMUM SIZE . IL _,-tM6YER ONLY). PIER CAPPED WITH CONCRETE 2" OR 4" THICK OR 1 X OR 2 X PRESSURE TREATED LUMBER 8" X 8' X 16" CELLED MASONRY BLOCKS WITH OPEN CELLS VERTICAL (PERPENDICULAR TO MAIN BEAM) 8,000 LBS. CAPACITY -SEE NOTE #1 MAIN FRAME I -BEAM J •.., \ \ �\ HOOD SHIMS DECAY RESISTANT) AND/OR PRESSURE TREATED LUMBER USED FOR HEIGHT ADJUSTMENT, I' MAX THICK AND 4• X 8' MINUMUM SIZE PIER CAPPED WITH CONCRETE 2" OR 4" THICK OR i X OR 2 X PRESSURE TREATED LUMBER 8' X 8' X 16' CEU.ED MASONRY BLOCKS WITH OPEN CELLS VERTICAL DOUBLE STACK BLOCK PIER 16,000 LBS. CAPACITY (SEE NOTE 11 & 12) 8' X 8" X 16' HOLLOW CONCRETE BLOCKS ARE SHOWN, BUT 8• X 4' X 16' BLOCKS (SOLID OR HOLLOW CORE) OR 1' TO 2" X 8" X 16' SOLID BLOCKS MAY BE USED. (TOP LAYER ONLY). WINDZONE qll (110 MPH) ALL EXPOSURES 20 PSF ROOF 10 PSF D.L. FLOOR MAXIMUM I -BEAM PIER SPACING (CONTROLLED BY PIER LOAD CAPACITIES) WIDTH MAX. 48" O.C. 72" O.C. 96" O.C. 120" O.C. 144" 0.;6. 144" WIDE FLOOR 2428 LBS. 3488 LBS. 4548 LBS. 5608 LBS. 6668 LBS: I 160" WIDE FLOOR 2661 LBS. 3838 LBS. 5014 LBS. 6191 LBS. 7368 LBS: I' 184" WIDE FLOOR 2961 LBS. 4288 LBS. 5615 LBS. 6941 LBS. 8268 LBS. NOTE: UNIT WIDTHS INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. (CHECK PIER PAD LOAD CAPACITIES BASED ON SOIL BEARING PSF) NOTES: 1. SEE SU-01-0020 FOR PIER SPACING WHEN USING 16" X 16' PIER PADS, WHEN USING 16' X 16' MIN. PIER PADS OTHER THAN CONCRETE THEY MUST BE LISTED AND CERTIFIED TO EXCEED OR EQUAL MIN. PIER CAPACITY. 2. WHEN USING PIER PADS THEY MUST BE LISTED AND CERTIFIED TO EXCEED OR EQUAL MIN. PIER CAPACITY. 3. START I -BEAM PIER SPACING 1/2 THE ALLOWABLE SPACING FROM EACH END OF THE HOME AT EACH I -BEAM, AND MAXIMUM SPACING SHOWN IN THE CHART ABOVE FOR FULL LENGTH OF HOME CALCS. tt111111111rrr NGI� STE • - O .• -i No. 910334 -o•• STATE OF DAPIA APPROVAL APPROVED BY l �i INC. FEDERAL MANUFAOTURED HOME CONSTRUCTION ANC SAFETY STANDARD; . MAR 4; 1 1999 JACOBSEN HOMES THESE sPEcmcA Ns`ARDoRAv csARE ........ M.T. 2-8-9,9; CRIONAI, PROPRIETARY. AND 00fi1OENTIAL DRAWING TITLE- P.O. ;❑ MATERIALS OF JACOBSEN MANUFACIMC ' P.O. BOX FLORIDA M SUCH MATERIALS ARE PROVIDED TO THE ALT. MAIN BEAM PIE S SAFETY ( HARBOR,) 26 1138 � EN � � t OTHM DRANNC NUMBER: - PHONE SU—O,-00 I; 16" X 16" PIER FOOTER SPACINGS* (MIN. 256 SQ.INJ MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR- 39" 62 1/2" 86 1/2" 110" SEE NOTE #4 SEE NOTE #4 144" WIDE FLOOR- 33" 53" 73 1/2" 93 1/2" 113 1/2" SEE NOTE #4 160" WIDE FLOOR- 30" 48 1/2" 66 1/2" 85^ 103" SEE NOTE f/4 184" WIDE FLOOR- 26 1/2" 42 1/2" 58 1/2" 74 1/2" 90 1/2" 107'• MIN. PIER CAPACITY 1778 LEIS 2667 LBS 3556 LBS 4444 LBS 5333 LEIS 6222 LEIS 18 1/2" X 18 1/2" PIER FOOTER SPACINGS* (MIN. 342 1 4 SQ.IN) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR- 54 1/2" 86" 117 1/2" SEE NOTE #4 SEE NOTE b4 1. SEE NOTE #4 144" WIDE FLOOR- 46" 73" 100" SEE NOTE #4 SEE NOTE #4 SEE NOTE y4 160" WIDE FLOOR.. 42" 66 1/2" 90 1/2 115" SEE NOTE #4 SEE NOTE #4 184" WIDE FLOOR.. 37" 58 1/2" 79 1/2" 101" SEE NOTE #4 SEE NOTE #4 MIN. PIER CAPACITY 2377 LBS. 3565 LBS. 4753 LBS. 5942 LBS. 7130 LBS. 8319 LBS. NOTE: UNIT WIDTHS WITH •. INCLUDES A 6•' OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE SU-01-0021 NOTES: 1. PRE -FABRICATED PIER PADS MAY BE USED AS AN ALTERNATE TO THE CONCRETE ENGINEER APPROVAL: ;•' [, V: DAPIA APPROVAL: /S>�£ CIi �� S- FOOTINGS SPECIFIED IN THE JACOBSEN HOMES SET-UP MANUAL. "C" c - r Y " c ) 5•v 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE APPROVED BY MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM PIER CAPACITIES SHOWN ABOVE. ALL OTHER REQUIREMENTS -� •• ~ A 4 t"+^ Ft- OtT 1 1 3. ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN HOMES INSTALLATION INSTRUCTIONS.rN %,� •'•-' •' -+ + n L'•''.`' ' ^ 4. MAX. PIER SPACING 8' FOR UNITS WITH 8' I -BEAMS / 10' FOR UNITS WITH 10' OR °''•• 12' I -BEAMS (24' MAX. FROM ENDS). FEDERALMANUfACTUREC] ON1E TI NANDSAFENSTANDARUS JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: D.M.T. DATE: lI 09-22-0�,' REV. LETTER: P.O. BOX 368 ORIGINAL. PROPRIETARY. AND CONFIDENTIAL SENARE MANUFACTURING INC. SUCH OF JACOMATERIALS INC. SUCH NATEPoAL$ ARE PRONGED TO DRAWING TITLE: PRE-FAB: 16• & 18 1 2" PIER PAD SPACINIG / ❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS DRAWING NUMBER: I2 SU-01-00221i 1B" X 22" PIER FOOTER SPACINGS* MIN. 396 SQ.IN) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) i WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR- 63 1/2" 100 1/2" SEE NOTE #4 SEE NOTE #4 SEE.NOTE #4 SEE NOTE #4 III 144" WIDE FLOOR** 54" 85" 116 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 1160" WIDE FLOOR- 49" 77 1/2" 105 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 1Y1184" WIDE FLOOR** 43" 68" 93" 117 1/2" SEE NOTE #4 SEE NOTE #4 IIIMIN. PIER CAPACITY 2747 LBS 4121 LBS 5495 LBS 6868 LEIS 8242 LBS 9616 LBS I ,I 20" X 20" PIER FOOTER SPACINGS* MIN. 400 SQ.IN) II MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 1120" WIDE FLOOR- II 64 1/2" 101 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 1114" WIDE FLOOR.. i 54 1/2" 86" 117 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 11�O" WIDE FLOOR** 49 1/2" 78 1/2" 107" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 1`I14" WIDE FLOOR­43 1/2" 69" 94" 119" SEE NOTE #4 SEE NOTE #4 MII . PIER CAPACITY 2778 LBS. 4167 LBS. 5556 LBS. 6944 LBS. 8333 LBS. 9722 LBS. NOTE: UNIT WIDTHS WITH •• INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE SU-01-0021 I "' " TO THE BRICATED EN Ci APPR�d •ry. �.� tt�.,,;...... jj��., DAPIA APPROVAL: 1 C& e4i-c PG1. F: Ii. P PIER PADS MAY BE USED AS AN ALTERNATE CONCRETE TINGS SPECIFIED IN THE JACOBSEN HOMES SET-UP MANUAL. Q. •. ATEF • l`�i�a T' Y - (�' ��� CC 2. TH1 PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE a %��- i�� _APPROVED 910334�T BY M UFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM t PIE CAPACITIES SHOWN ABOVE. ZQ•�® 3. A `OTHER REQUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN ;tSTAT -` HOMES INSTALLATION INSTRUCTIONS. 4. MA PIER SPACING 8' FOR UNITS PATH 8' I -BEAMS / 10' FOR UNITS WITH 10' OR �y .. d� ' A� _w - 12 —BEAMS (24• MAX. FROM ENDS). , ,•0 y4 s INC EDERAL MANUFACTURED HOME c rocllc I!I 0 0� JACOBSEN HOMES NOTICE: F e4� THESE SPECIFlCATIONS AND DRAWINGS ARE 4D BY: D.M.T. DATE: 09-22-01 REV. LETTER: DRAWING TITLE: PRE—FAB. 18' X 22" & 20" PIER PAD SPACING P.O. BOX 368 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC, SUCH MATERIALS ARE PRONDED TO THE — m SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 RECIPIENT FOR SPECIM PURPOSES AND MUST BE KEPT CONFlDENTIAL AND SECRET FROM OTHERS DRAWING NUMBER: SU-01-0024 17 3/16" X 25 3/16" PIER FOOTER SPACINGS* (MIN. '432 7/8 SQ.IN) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR- 70 1/2" 110 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 144" WIDE FLOOR-- 59 1/2" 93 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 160" WIDE FLOOR. 54" 85" 116" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 184" WIDE FLOOR- 47 1/2" 75" 102" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 MIN. PIER CAPACITY 3004 LBS. 4507 LBS. 6009 LBS. 7511 LBS. 9013 LBS. 10,516 LBS. 24" X 24" PIER FOOTER SPACINGS* (MIN. 576 SQ.INj MAXIMUM I -BEAM . PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY;; WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 35010 (PSF) 120" WIDE FLOOR.. 95 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEI EI,NOTE #4 144" WIDE FLOOR-- 81" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE, NOTE #4 160" WIDE FLOOR** 74" 115" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 184" WIDE FLOOR-* 65" 101" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 MIN. PIER CAPACITY 4000 LBS 6000 LBS 8000 LBS. 10,000 LBS. 12,000 LBS. 114.000 LBS. NOTE: UNIT WIDTHS WITH •. INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. I FOR TYPICAL PIERS SEE PAGE SU-01-0021 �y� NOTES: 1. PRE -FABRICATED PIER PADS MAY BE USED AS AN ALTERNATE TO THE CONCRETE EN kP OVA ; F, '!� �• Q. • �Ti l` G .•••C>>S ''r" 4` DAPIA APPROVAL: I I C�rc1-5! P& FOOTINGS SPECIFIED IN THE JACOBSEN HOMES SET-UP MANUAL. No. 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE 910334 ` APPROVED Y MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM �„w® i PIER CAPACITIES SHOWN ABODE. 'd •'. STATE � : QT 1 1 3. ALL OTHER REQUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN � � •' 9 HOMES INSTALLATION INSTRUCTIONS 4. MAX. PIER SPACING 8' FOR UNITS WITH B' I -BEAMS / 10' FOR UNITS WITH 10' OR12' r Cam'• 1t, ,1,'7"•' •�`� I�. IW SEDERALMANUFACTURED I -BEAMS (24' MAX. FROM ENDS). ElElElEll JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: D.M.T. ATE: Ili I 09-22-0,11 REV. LETTER: ❑❑■❑ORIGINAL, ❑„❑ P.O. BOX 368 SAFETY HARBOR, FLORIDA 34595 I PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE RECIPIENT FOR SPECu1C PURPOSES AND MUST BE — DRAWING TITLE: PRE-FAB. 17 X 25 & 24- PIER PAD SPACING DRAWING NUMBER: IIII SU-01-002V1 ❑❑❑ PHONE (813) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS PIER FOOTER SIZING CHART FOR MARRIAGE WALL OPENINGS Q1 (FOR SIDEWALL OPENINGS SEE NOTE Q3 ) LOAD SPANS SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' w Q 1000 390 sq. in. 494 sq. in. 597 sq. in. 701 sq. in. 805 sq. in. 908 sq. in. 1500 260 sq. in. 329 sq. in. 398 sq. in. 467 sq. in. 536 sq. in. 606 sq. in. 2000 195 sq. in. 247 sq. in. 299 sq. in. 351 sq. in. 402 sq. in. 454 sq. in. C\2 2500 156 sq. in. 197 sq. in. 239 sq. in. 280 sq. in. 322 sq. in. 363 sq. in. MIN. PIER CAP. 2708lbs. 3428lbs. 4148lbs. 4868lbs. 5588lbs. 6308lbs. LOAD SPANS w SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' Q 1000 409 sq. in. 519 sq. in. 628 sq. in. 737 sq. in. 847 sq. in. 956 sq. in. 1500 273 sq. in. 346 sq. in. 419 sq. in. 492 sq. in. 565 sq. in. 638 sq. in. 2000 205 sq. in. 259 sq. in. 314 sq. in. 369 sq. in. 423 sq. in. 478 sq. in ir7 2500 164 sq. in. 207 sq. in. 251 sq. in. 295 sq. in. 339 sq. in. 383 sq. in C\l MIN. PIER CAP. 2841 lbs. 3601 lbs. 4361 lbs. 5121 IDS. 5881 lbs. 6641 lbs. LOAD SPANS w SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' Q 1000 428 sq. in. 544 sq. in. 659 sq. in. 774 sq. in. 889 sq. in. 1004 sq. in. 1500 286 sq. in. 362 sq. in 439 sq. in. 516 sq. in. 593 sq. in. 670 sq. in. CID 2000 214 sq. in. 272 sq. in. 329 sq. in. 387 sq. in. 445 sq. in. 502 sq. in. co 2500 171 sq. in. 217 sq. in. 264 sq. in. 310 sq. in. 356 sq. in. 402 sq. in. MIN. PIER CAP. 2975lbs 3775lbs 4575lbs 5375lbs 6175lbs 6975lbs LOAD SPANS w SOIL BEARING CAPACITY PSF 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' la 1000 486 sq. in. 618 sq. in. 751 sq. in. 883 sq. in. 1016 sq. in. 1148 sq. in. CID 1500 324 sq. in. 412 sq. in. 501 sq. in. 589 sq. in. 677 sq. in. 766 sq. in. l 2000 243 sq. in. 309 sq. in. 375 sq. in. 442 sq. in. 508 sq. in. 574 sq. in. 0 2500 194 sq. in. 247 sq. in. 300 sq. in. 353 sq. in. 406 sq. in. 459 sq. in. C0 MIN. PIER CAP. 3375lbs 4295lbs 5215lbs 6135lbs 7055lbs 7975lbs i rNDZONE III (1�10 MPH) IL. EXPOSUR >0 PSF ROOF 0 PSF D.L. NOTES: W. ML;b. Q SEE DETAIL 'B'. PAGE SU-01-0001 FOR BLOCKING AND ANCHORING OF MARRIAGE WALL 1111111 I I, OPENINGS N AND ® UNDER TABLE I, PAGE SU-01-0040. ENG!`;k�i� Pf�OVAL....� �DAPIA APPROVAL @SEE NOTES: @ Q QFOR ALL UNIT WIDTHS, USE 177 sq/m PIER FOOTER UNDER SIDEWALL OPENINGS. THAT `�VQ • q •lt! ''i�i APPROVED BY ARE 49 INCHES TO 96 INCHES VIDE FOR OPENINGS THAT ARE 96 INCHES TO 144 Q� No. y INCHES. USE 242 sq/"a PIER FOOTER UNDER SIDEWALL OPENINGS. (MIN. t000 PSF SOIL BEARING REO'D) - 910334 •; ' f. I ® FOR PROPER LOAD SPANS, SEE SU-03-0001. ('LOAD SPANS' ARE CLEARSPANS; PIERNIP �C- SPECIFICATIONS ABOVE ASSUME CLEARSPAN OCCURS ON ONE SIDE OF PIER ONLY - E OFII'IF CLEARSPAN OCCURS ON BOTH SIDES, ADO VALUES LISTED ABOVE FOR EACH CLEARSPAN) '0 '. QS CHECK V41H LOCAL JURISDICTION TO DETERMINE THE SOIL VALUE ON YOUR ': �Q '• /w,D ' �� FEDERAL MANUFACTUREOROME SITE OR HAVE A SOIL BEARING TEST PERFORMED ON YOUR SOIL TO DETERMINE THE VALUE. ��i •:r �� CONSTRUCTIONIWOSAFETXSTANOAflOS MAR 10 1 1999 JACOBSEN HOMES THESE SPECIFICATIOONS`AND DRAWINGS ARE 1 �� B.E.M.DATE: 2-6-99 REV. LETTER: ■ ORIONAL. PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: PIER FOOTER SIZING CHARM A P.O. BOX 368 MAIERIALS OF JACOBSEN MANUFACTURING,ISAFETY HARBOR, FLORIDA 34695 INC. SUCH MAIFRIALS ARE PROVIDEDTO DIE FOR MARR. WALL OPENINGS REOFIO+T FOR SPEC>F1C PUSSES AM1 MUST BE DRAWING NUMBER: I I PHONE (727) 726-1138 KEPT CCNFIDFRTML AND SECRET FROM OTHERS SU—01-003OI II TABLE I PIER FOOTER SIZING AND PIER SPACING CHART (SEE NOTES BELOW) 12-WIDE WIDTH MAXIMUM (j) ( PIER SPACING SOIL BEARING PSF CAPACITY Q © REQUIRED PIER FOOTER AREA, SQ. IN. 3'-0" MAXIMUM FROM EACH END 1000 655 AND 8'-0" ON CENTER MAXIMUM 1500 437 (MINIMUM PIER CAPACITY 4548#) 2000 327 2500 262 4'-0" MAXIMUM FROM EACH END 1000 808 AND 10'-0" ON CENTER MAXIMUM 1500 538 (MINIMUM PIER CAPACITY 5608#) 2000 404 2500 323 13'- 4"- WIDE WIDTH MAXIMUM Q PIER SPACING SOIL BEARING PSF CAPACITY © REQUIRED PIER FOOTER AREA, SQ. IN. S—O" MAXIMUM FROM EACH END 1000 716 AND 8'-0" ON CENTER MAXIMUM 1500 478 (MINIMUM PIER CAPACITY 5014j) 2000 358 2500 287 4'-0" MAXIMUM FROM EACH END 1000 884 AND 10'-0" ON CENTER MAXIMUM 1500 590 (MINIMUM PIER CAPACITY 6191#) 2000 442 2500 354 15'-4"-WIDE WIDTH MAXIMUM (5 PIER SPACING SOIL BEARING PSF CAPACITY Q2 © REQUIRED PIER FOOTER AREA, SQ. IN. 3'-0" MAXIMUM FROM EACH END 1000 807 AND 8'-0" ON CENTER MAXIMUM 1500 539 (MINIMUM PIER CAPACITY 5615#) 2000 404 2500 323 4'-0" MAXIMUM FROM EACH END 1000 1000 AND 10'-0" ON CENTER MAXIMUM 1500 666 (MINIMUM PIER CAPACITY 6941g) 2000 500 2500 400 U `ON MULTIPLE SECTION HOUSES, CHECK EACH SECTION INDIVIDUALLY. O2 I UNDISTURBED SOIL OR 90% COMPACTION FOR FILL. 03 FOOTERS TO BE BELOW FROST LINE. ® �Ll- ORE THAN ONE PIER MAY BE USED TO ACHIEVE THE MINIMUM SQUARE INCHES REQUIRED. OS ALL UNIT WIDTHS TO INCLUDE 6" SIDE OVERHANG ONE SIDE OR ONE 3" PVERHANG ON EACH SIDE MAXIMUM. © CHECK WITH LOCAL JURISDICTION TO DETERMINE THE SOIL VALUE ON (OUR SITE OR HAVE A SOIL BEARING TEST PERFORMED ON YOUR SOIL TO DETERMINE THE VALUE. �y �. V,ic 4� No. a 910334 �TAT� OF W = ALL ZONES ALL EXPOSURES 20 PSF ROOF 10 PSF D.L. DAPIA APPROVAL' APPROVED BY I 44� INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDAROS MAR 0 1 1999 JACOBSEN HOMES NOTICE' 7111811 1�ppmuT: UA IL' TRY. LLI IM THESE SPECIFICATIONS AND DRAWINGS ARE M.T. 2-8-99 ORIGINAL, PROPRIETARY. AND MEMENRAL DRAWING TITLE: n MATERIALS OF JACOBSEN MANUFACIURING P.O. 80X 368 !H\ \, INC. SUCH MATERIAS ARE PROVIDED TO THE PIER FOOTER SPECS CHART SAFETY HARBOR, FLORIDA 34695 RECNENT FOR SPECK PUNPOst;s AM WST BE DRAWING NUMBER: PHONE (727) 726-1138 REPT CONRDENRAL AND SECRET FROM OTHERS SU-01-0040 MOBILE HOME SET-UP DIM. 'A' DIM. 'B' MN #1 COLUMN #2 COLUMN #3 COLUMN SUPPORT SPANS TO PROPERLY SIZE PIERS LOCATED AT RIDGE BEAM SUPPORT COLUMNS, SURVEY THE ARRANGEMENT OF THE ROOMS IN THE MOBILE HOME TO LOCATE THE OPENINGS ALONG THE I; MARRIAGE WALL OF THE HOME. MEASURE EACH OPENING IN THE MARRIAGE WALL PAYING ATTENTION PARTICULARLY TO OPENINGS GREATER THAN 4 FEET WIDE. IN THE EXAMPLE ABOVE TO DETERMINE THE SPAN FOR COLUMN #1 SIMPLY USE DIMENSION 'A'. TO DETERMINE THE SPAN FOR COLUMN #2 ADD DIMENSION 'A' AND DIMENSION 'B' TOGETHER. THE SPAN FOR COLUMN #3 CAN BE DETERMINED THE SAME WAY AS COLUMN #1 SIMPLY USE DIMENSION 'B'. ONCE THE COLUMN SPANS HAVE BEEN DETERMINED, FIND THE CORRESPONDING PIER FOOTING SIZE IN THE CHART (SU-01-0030). ❑❑❑❑ ❑❑■❑ ❑„❑ ❑❑❑❑ JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: I DRAWING TITLE COLUMN SUPPORT SPANS DRAWING NUMBER: SU-03-0001 Ili CLOSE-UP NOTES DURING SET-UP ALL SEAMS BETWEEN FRAMING MEMBERS ON THE FLOORS AND EXTERIOR WALLS OF MULTIPLE WIDE UNITS MUST BE SEALED. THIS SHALL BE ACCOMPLISHED BY ANY OF THE FOLLOWING METHODS: 1. BLACK FABRIC TAPE ADHEARED TO BOTH SECTIONS BEFORE APPLING THE ON -SITE FINISH MJERIALS. 2. FOILCORE OR THERMO-PLY STRIPS (2" WIDE MIN.) FASTENED TO BOTH SECTIONS W/ MIN. 7/,6" X 5/8" X 16 GA. STAPLES 6" O.C. MAX. SPACING (APPLIED BEFORE ON -SITE FINISH MATERIALS). 3. SMALLER GAPS APPROX. 1/4" WIDE MAY BE SEALED WITH A BEAD OF LATEX CAULK (OR EQ,,AL). BEFORE SETTING MULTIPLE WIDE UNITS THE CLOSE-UP PLASTIC SHIPPING MATERIAL MUST BE REMO\ ED FROM ALL EXTERIOR WALLS OF ALL SECTIONS. THE SHIPPING PLASTIC MAY BE LEFT IN PLACE ON ALL MATING OR MARRIAGE WALLS OF EACH SECTION, BUT THE PANEL STRIPPING MATERIAL OUTSIDE THE CLOSE-UP SHIPPING PLASTIC MUST BE REMOVED TO ALLOW THE MULTIPLE WIDE SECTIONS TO BE BROUGHT TOGETHER WITH MINIMUM GAPPING BETWEEN THE SECTIONS. AFTER THE UNITS ARE PLACED TOGETHER THE CLOSE-UP PLASTIC MATERIAL LEFT ON THE MARRIAGE WALLS MAY BE CUT-OUT AT ALL OPENINGS THROUGH THE MATING WALLS TO OTHER MULTIPLE WIDE SECTIONS. AFTER REMOVAL OF THE GALVANIZED WIND DEFLECTOR LOCATED ON THE ROOF AT THE HITCH END )F EACH UNIT OF THE HOME. ANY PENETRATIONS OF THE ROOF SHINGLES MUST BE SEALED WITH A ROOFING ',EMENT OR OTHER SUITABLE MATERIAL. ALL CEILING FAN PREPS AND/OR FIXTURE PREPS LOCATED ON THE MATING LINE OF MULTIPLE WIDE UNITS MUST BE TEMPORARILY REMOVED FOR THE SET-UP OF THE HOME. WHEN REINSTALLING THE PREPS (ELECTRICAL BOXES) A FIXTURE FLASHING RING MUST BE INSTALLED BETWEEN THE FINISH MATERIAL (CEILING BOARD AND/OR PANELING) AND THE ELECTRICAL BOX. THE FIXTURE FLASHING RING IS PROVIDED WITH THE HOME (SHIPPED WITH THE SET-UP KIT) AND MUST BE INSTALLED DURING THE SET-UP OF THE HOME. THE FIXTURE FLASHING RING IS REQUIRED TO PROTECT THE FINISH MATERIAL FROM POSSIBLE FIRE HAZARDS FROM ELECTRICAL SHORTS OR EXCESSIVE HEAT BUILDUP FROM THE ELECTRICAL SYSTEM. THE FIXTURE FLASHING RING CAN BE IDENTIFIED AS THE THIN WHITE FIBROUS DONUT LOOKING RING IN THE SET-UP KIT. NOTE: BEFORE INSTALLING A CEILING FAN INSTALL A 4 CU. IN. MIN. BOX EXTENSION. (CHECK FACTORY INSTALLED CEILING BOX FOR LABELING INDICATING SUITABLE FOR DIRECT ATTACHMENT OF CEILING FAN FIXTURE -IF NOT LABELED AS BEING SUITABLE, YOU MUST INSTALL A HOOK TYPE CEILING FAN -INSTALL HOOK THROUGH BOX INTO LUMBER BACKER BEHIND FAN BOX.) THE SAFETY CHAIN FOR ALL EXTERIOR OUTSWING DOORS SHALL BE INCLUDED IN THE SET-UP KIT. THE SAFETY CHAIN SHALL BE INSTALLED WHEN THE HOME IS SET-UP. INSTALL THE SAFETY CHAIN PER THE MANUFACTURERS SPECIFICATIONS INCLUDED WITH THE SAFETY CHAIN HARDWARE. FASTEN ALL EXTERIOR SIDING IN THE HORIZ. DIRECTION W/ MIN. 7/16" x 1" x 16 GA. STAPLES 16" O.C. MAXIMUM THROUGH SHEATHING INTO STUD. FASTEN ALL EXTERIOR TRIM W/MIN. 7/16 x 5/8' x 16 GA. STAPLES AT 6" O.C. MAXIMUM. III DE]❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAN7NGS ARE DRAWN BY: S.A. DATE: 12-22-94 REV. LETTER: ❑;II,❑ ❑❑0❑ P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFDENTAL AND SECRET FROM OTHERS. DRAWING TITLE: CLOSE-UP NOTES DRAWING NUMBER: SU-05-001 _ EXTERIOR ROOFING CLOSE-UP RIDGE SHINGLES OR TABS CUT FROM THREE —TAB SHINGLES FURNISHED IN THE SET—UP MATERIALS APPLIED OVER COMPLETED SHINGLE ROOFING I (INSTALL RIDGE SHINLGES PER ++ I I MANUFACTUERS INSTALLATION INSTRUCTIONS.) + I ++ I I +I I I+ I I I I I + •nul. + IIp. + ^Illli + ,uu. •auo. �Ilm. .nun. Elul,. .ipll. — COMPLETE SHINGLE ROOF BY ADDING FINISHING COURSE(S) TO SHINGLES INSTALLED IN THE FACTORY. ALLOW TOP END OF TOP ROW OF SHINGLES TO EXTEND ACROSS RIDGE ONTO OPPOSING SECTION OF MULTIPLE WIDES. (SEE SU-05-0011 FOR SHINGLE FASTENING REQUIREMENTS.) — COMPLETE SHINGLE ROOFING BY INSERTING FINISHING COURSE(S) OF SHINGLES TO EXISTING SHINGLES INSTALLED AT THE FACTORY. LIFT THE UPPER ROW OF SHINGLES AT THE TABS TO INSERT FINAL COURSE OF SHINGLES AND FOLLOW THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS FOR FASTENING. (THIS APPLICATION FOR TRIPPLE WIDES ONLY) NOTES: � 1. RIDGE SHINGLES ARE FACTORY APPLIED ON TRIPPLE WIDE HOMES, AND MUST Ili BE APPLIED DURING SET—UP FOR DOUBLE WIDE HOMES. ❑❑❑ ❑ ❑❑■❑ ❑„❑ ❑❑❑❑ JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWN BY: S.A. I DATE: 6-6-94 REV. LETTER: i DRAWING TITLE: EXTERIOR ROOFING CLOSE-UP DRAWING NUMBER: SU-05-0010 III SHINGLE INSTALLATION ROOF SHEATHING (TYP.) SHINGLE UNDERLAYMENT 'a41. FIBERGLASS SHINGLES ua. •mu.. +pll. +Ilhf ^ally .ihlp"hO�+II. a Chu. ..pa, +uu,. +uu,. +uv,. II j TYPICAL ROOF TRUSSES 16" ON CENTER i 1/2" 1/2" IIII 1T0, O 3 TO 3' 1/2„ METAL DRIP EDGE 1 1/2" A TO 1 1/2" c "o� n I— Lf) 'O SEE PAGE RC-19-0002 NO 'ES: 1. SHGLES FASTENED W/ MIN. 1" X 3/4" X 16 GA. STAPLES AS SHOWN IN ITHE SHINGLE FASTENING DETAIL. IF A STAPLE IS OVER -DRIVEN, PR PERLY INSTALL ANOTHER STAPLE RIGHT OR LEFT OF OVER -DRIVEN ST 'PLE AND SEAL OVER -DRIVEN STAPLE WITH ROOFING CEMENT. 2. WH N METAL DRIP EDGE IS INSTALLED, IT IS NOT NECESSARY FOR SHI GLES TO OVERHANG THE RAKE (FRONT & REAR) EDGE OF THE ROOF. 3. SHI I GLE UNDERLAYMENT FASTENED TO DECKING W/ MIN. 3/8" X 3/4'• X 18 A. STAPLES MIN. (TACKED DOWN UNTIL SHINGLES ARE APPLIED). 4. ME I,L DRIP EDGE FASTENED TO DECKING W/ MIN. 3/8" X 3/4" X 1B GA. STAILES 12" O.C. MAXIMUM. 5. SHI LE ROOF COVERINGS WHICH ARE SECURED W/ 6 FASTENERS PER SHINGLE THR UGH AN UNDERLAYMENT WHICH IS CEMENTED DOWN TO 3/8" STRUCTURAL RATtD ROOF SHEATHING NEED NOT BE EVALUATED FOR DESIGN WIND PRESSURES. FASTENING DETAIL NOTE: SHINGLES INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS ONLY WHEN SPECIFIC APPLICATIONS ARE NOT COVERED WITHIN THIS MANUAL. ❑❑❑❑ JACOBSEN HOMES ❑❑M❑ ❑,PF❑ P.O. BOX 368, 901 4lh ST. NORTH ❑❑❑❑ SAFETY HARBOR, FLA. 34695 PHONE (813) 726-1138 SHINGLE INSTALLATION © 6-6-94 REVISIONS: DATE: 12-21-94 SU-05-0011 EXTERIOR FINISH CLOSE-UP SOFFIT AND FASCIA APPLICATION DETAIL METAL DRIP EDGE ;ILAP SOFFIT MATERIALFASCIA MATERIAL RECEIVER (J CHANNEL) NOTES: 1. ALL MATERIALS REQUIRED FOR ON SITE COMPLETION OF THE LAP SIDING APPLICATION IS SHIPPED INSIDE THE HOME WITH THE SET—UP KIT. 2. FIRST LOCATE AND SECURE THE SOFFIT MATERIAL TO EACH SECTION OF THE HOME WITH EITHER STAPLES, NAILS, OR SHEET METAL SCREWS 6" O.C. 3. NEXT LOCATE AND SECURE THE FASCIA MATERIAL IN THE SAME MANNER AS LISTED ABOVE FOR THE SOFFIT. 4. THEN COMPLETE THE APPLICATION OF BOTH THE METAL DRIP EDGE AND THE LAP SIDING RECEIVER. 5. AFTER ALL PARTS HAVE BEEN JOINED AT THE MATING EDGES OF EACH SECTION OF THE HOME, BEGIN WITH N THE LAP SIDING APPLICATION. START THE LAP SIDING APPLICATION AT THE BOTTOM OF THE HOME AS SHO IN THE LAP SIDING APPLICATION DETAIL BELOW. ALL TRIM AROUND OPENINGS (ie. WINDOWS AND DOORS) IS COMPLETED BEFORE THE HOME IS SHIPPED. LEAVE AMPLE ROOM AT ALL TRIM FOR THE LAP SIDING TO EXPAND AND CONTRACT WITH TEMPERATURE CHANGES. FOR ANY .ADDITIONAL INFORMATION REQUIRED SEE THE MANUFACTURERS INSTALLATION INSTRUCTIONS PLACED INSIDE THE SET—UP KIT SHIPPED WITH THE HOME . I , I LAP SIDING FASTENING: 1. SECURE HORIZ. LAP SIDING W/ MIN. 7/16" X 1" X 16 GA. STAPLES 16" 0. C. MAXIMUM THROUGH SHEATHING INTO STUD. SECURE ALL EXTERIOR TRIM W/ MIN. 7/16" x 5/8" x 16 GA.. STAPLES AT 6" 0. C. MAXIMUM. 2. WITH METAL LAP STAPLE CROWNS MAY BE EITHER PARALLEL OR PERPENDICULAR TO NAILING FLANGE WITH BOTH LEGS OF STAPLE PENETRATING THE NAILING FLANGE. 3. WITH VINYL SIDING STAPLE CROWNS TO BE PERPENDICULAR TO NAILING FLANGE WITH ONE LEG CENTERED IN SLOT AND OTHER LEG ON OUTSIDE OF NAILING FLANGE WITH APPROX. 1/32" SPACE BETWEEN STAPLE CROWN AND NAILING FLANGE. I 4. ALL FASTENERS TO BE WEATHER RESISTANT. BOTTOM STARTER STRIP , HOOK STARTER LAP ON----* STARTER STRIP LAP SIDING APPLICATION DETAIL i i I I I JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: S.A. DATE: 12-22-94 EV. LETTER: DRAWING TITLE: RHiH ORIGINAL, PROPRIETARY, AND CONFIDENTIAL I [APE-] „❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE EXTERIOR FINISH CLOSE-UP DRAWING NUMBER: SU-05-0020 ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND ,Iil1�T BE KEPT CONFIDENTIAL AND SECRET FROM'OTHERS. III MOBILE HOME SET-UP/CLOSE-UP SITE INSTALLED EXTERIOR SIDING APPLICATION SEE OTHER DETAILS (SU-05-0031 THRU 0034) FOR PLAN VIEW DETAILS IDENTIFING AREAS REQUIRING EXTERIOR SIDING TO BE SITE INSTALLED. SEE SU-05-0020 FOR LAP SIDING FASTENING, AND SOFFIT AND FASCIA APPLICATION. ALL AREAS WHERE THE. EXTERIOR SIDING MATERIALS EXTEND ACROSS THE MATING LINE BETWEEN MULTIPLE WIDE UNITS ARE REQUIRED TO BE FINISHED ON SITE TO PREVENT A CONTINUOUS SEAM IN THE EXTERIOR SIDING LOCATED AT THE MATING LINE(S) OF THE HOME. ALL TRIM AND EXTERIOR SIDING MATERIALS ARE PROVIDED IN THE HOME SET—UP KIT FOR COMPLETION OF ALL EXTERIOR SIDING APPLICATIONS FOR THE HOME. THE STARTER STRIP FOR THE LAP SIDING APPLICATION IS INSTALLED AT THE FACTORY TO ENSURE STRAIGHT ALIGNED APPLICATION OF THE SIDING. ALL TRIM MATERIALS NOT REQUIRING FASTENING TO MORE THAN ONE SECTION OF MULTIPLE SECTION HOMES IS ALSO FACTORY INSTALLED TO ENSURE PROPER CLEARANCES AND AN ASSURED MATCH TO THE REMAINDER OF THE HOME. ALL TRIM MATERIALS SECURED TO MORE THAN ONE SECTION OF THE HOME ARE TO BE FASTENED TO THE WALL FRAMING MEMBERS WITH MIN. 7/16" X 5/8" X 16 GA. STAPLES OR 1" ROOFING NAILS 6" O.C. MAXIMUM. TAKE CARE IN LOCATING TRIM MATERIALS TO ENSURE PROPER ALIGNMENT WITH THE FACTORY INSTALLED MATERIALS. ALL FASTENERS USED MUST BE WEATHER RESISTANT TO INSURE DURIBILITY. ENCLOSED WITH THE EXTERIOR SIDING MATERIALS ARE THE MANUFACTURERS INSTALLATION INSTRUCTIONS DETAILING THE RECOMENDED INSTALLATION PROCEDURES AND SPECIFICATIONS FOR THE TYPE OF SIDING BEING USED ON THE HOME. CAREFULLY EXAMINE THE MANUFACTURERS INSTALLATION INSTRUCTIONS BEFORE ANY ATTEMPT TO COMPLETE THE REQUIRED INSTALLATION OF THE EXTERIOR SIDING MATERIALS. SHOULD FOR ANY REASON THE MANUFACTURERS INSTALLATION INSTRUCTIONS BE LOST OR MISSING, CONTACT JACOBSEN HOMES AT 901 4th Street North Safety Harbor, Florida 34695 OR CALL (727) 726-1138 FOR REQUESTING THE INSTALLATION INSTRUCTIONS. III ❑❑©❑ ❑❑�❑ ❑„❑ ❑❑�❑ JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING SUCH MATERIALS ARE PROVIDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS DRAWN BY: S.A. I DATE: 6-6-94 REV. LETTER: ' — DRAWING TITLE: EXTERIOR SIDING APPLICATION DRAG NUMBER: DRAWING SU-05-0030 APPROVED BY INC. .. � n�l %�LLr�•Frj t�� W3tr4 VIr:�/L51DI�G� ,� tl - i "I- IlttvritA - I J >�:lirll� Hli j aw.pm Y v . I� II i li , , i+-%a• G u' - _ _.- IG gic- jt4M -SM-p. CTYP) h'i • it �i __ CMPtX�._ _ rjX9(, *pcs 0 TH FA 0 2 .. Z: 7tlE 2 btlb 3 i'rf"=='VlTii'L� 5t�ruC,� INSratL.l4L�onj L1. kALk=.kY P=hoL• . APPROVED BY 0 000" N r;l JUL 1 3 OR FMMMEW me INC �xj�RiC7p, �&;T ..l_t�l�i itLL�T10t\I Cu,av�Ryiti�r►.si�n�� I � I I �I I I � i i j � I1�tDbl�1 _ • peoaR m�oro *pm- TH ' cl, 12.�.. i o c o 0 0 WITH . - I-IIoL�� x"yt(il�til X 2i�2' h(A� I Ca"O.G- lrt��TvbS (Njll.l.) • .: IL 17 jY�'V1141'L �iDtW,j'INSt�I..�PG*L ii lV -------------- i MOBILE HOME SET-UP I I ! SHUTTER INSTALLATION: SHUTT RS ARE NORMALLY FASTENED BY SCREWING DIRECTLY THROUGH THE VINYL SIDING. THIS TENDS TO RESTRICT SIDE —TO —SIDE MOVEMENT OF THE VINYL SIDING PANELS. HOWEVER, SEVERAL THINGS CAN BE DONE TO ELIMINATE BUCKLING OR OIL CANNING OF THE VINYL SIDING IN THESE AREAS: A. WHEN PANELS RUN FROM WINDOW AREA TO A CORNER POST OR I OR J—CHANNEL (OR ANY TYP. VINYL SIDING TRIM) AT THE OPPOSITE { END, BE SURE TO LEAVE PROPER CLEARANCE IN THE -POCKET" — THEN SIDING WILL EXPAND TOTALLY IN THAT DIRECTION. B. TWO SHUTTERS BETWEEN WINDOWS: THE PANELS THAT WILL BE RESTRICTED BY THE SHUTTER SCREWS SHOULD BE SHORTER LENGTHS (SEAM BETWEEN WINDOWS — NOT ONE CONTINUOUS PIECE OF VINYL) — SIMPLY OVERLAP TWO PANELS IN THIS AREA. PANELS WILL THEN EXPAND TOWARD THE OVERLAP JOINT (SEE DETAIL "A"). OR Y STAGGER THE SHUTTER SCREWS — INSTALL FIRST SHUTTER, TAKE NOTE OF WHICH PANELS ARE RESTRICTED BY THE SCREWS. THEN INSTALL THE OPPOSITE SHUTTER, POSITION THE SCREWS FOR THIS SHUTTER THROUGH PANELS EITHER ABOVE OR BELOW THE PANELS RESTRICTED BY THE SCREWS FROM THE FIRST SHUTTER. BY DOING THIS THE PANELS OF VINYL SIDING WILL BE ABLE TO EXPAND IN AT LEAST ONE DIRECTION, SO LONG AS PROPER CLEARANCE HAS BEEN MAINTAINED IN THE "POCKET" AREA OF THE CHANNEL. (SEE DETAIL "B") i „ I DETAIL B I �I ll DETAIL "A" I ❑D❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: ❑❑■❑ ❑„❑ P.O. BOX 368 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE DRAWING TITLE: SHUTTER INSTALLATION ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-05-0034 it of MOBILE HOME SET-UP T)EDOWNS THERE ARE TWO TYPES OF WIND THAT CAUSE DAMAGE. HORIZONTAL AND UPLIFT. YOUR HOME IS DESIGNED FOR THE HURRICANE ZONE (ZONE III). IF YOU FOLLOW OUR RECOMMENDATIONS YOU WILL PROTECT YOUR HOME FROM BOTH TYPES OF WIND FORCES. IN TIEING DOWN YOUR HOME, YOU MUST USE MATERIALS OF ADEQUATE STRENGTH AND SPECIFICATIONS. ANCHORING EQUIPMENT— (LOAD RESISTANCE) ANCHORING EQUIPMENT SHALL BE CAPABLE OF RESISTING AN ALLOWABLE WORKING LOAD EQUAL TO OR EXCEEDING 3.150 POUNDS AND SHALL BE CAPABLE OF WITHSTANDING A 50 PERCENT OVERLOAD (4.725 POUNDS TOTAL) WITHOUT FAILURE OF THE ANCHORING EQUIPMENT. ANCHORING EQUIPMENT— (WEATHERIZATION) ANCHORING EQUIPMENT (STRAPS, ETC...) EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIORATION AT LEAST EQUIVALENT TO THAT PROVIDED BY A COATING OF ZINC ON STEEL OF NOT LESS THAN 0.30 OUNCES PER SQUARE FOOT OF SURFACE COATED, AND IN ACCORDANCE WITH THE FOLLOWING: SLIT OR CUT EDGES OF ZINC —COATED STEEL STRAPPING NEED NOT BE ZINC COATED. TIE —DOWN STRAPS SHALL BE TYPE 1. FINISH B. GRADE 1 STEEL STRAPPING. 1, 1 /4 INCHES WIDE AND 0.035 INCHES IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL, AND SEALS. ANCHORING NOTE: THERE IS A TENDENCY FOR THE TOP OF THE ANCHOR ROD TO DEFLECT AND MOVE OR 'SLICE" THROUGH THE SOIL WHEN LOADED WITH THE FRAME TIE. THIS IS NOT DESIRABLE. SINCE IT PERMITS THE MOBILE HOME TO BE DISPLACED DOWNWIND AND TEND TO SLIDE OFF THE PIERS. TO MINIMIZE DEFLECTIONS. AUGER —TYPE AND OTHER ANCHORS USING STEEL RODS � SHOULD BE PUT ON AT AN ANGLE SO THEY ARE MORE IN LINE WITH THE DIRECTION OF PULL.I. THIS CAN BEST BE ACCOMPLISHED BY INSTALLING THE ANCHORS PRIOR TO PLACEMENT OF THE FOR MOBILE USEHOME ucRTIOCALLY LOT. THEI VERTICALREOUI EDSFORETHESIREDSTRAPPING BEING. THERATT C1HED_ LIS`I D APPROVED BY1N I' JUL 1 3 j INC. CAUTION: DO NOT PRETENSION TENSION TIE —DOWN STRAPS ON ONE SIDE OF THE HOME ONLY. IF t' N,$ION IS NOT APPLIED TO TIE —DOWNS ALTERNATELY ON OPPOSITE SIDES, THE HOME MAY B_ PUL..ED OFF THE SUPPORTS. �,,�„•� 6-6-94 �_ SU-07-0001 MOBILE HOME SET-UP/ELECTRICAL ELECTRICAL CONNECTIONS BETWEEN HOME SECTIONS NOTE: NO ELECTRICAL POWER SHOULD BE CONNECTED TO HOMES WHILE MAKING ELECTRICAL CONNECTIONS. ALL ELECTRICAL WORK SHOULD BE DONE BY A QUALIFIED ELECTRICIAN. MATERIAL SUPPLIED 1. APPROPORATE NUMBER OF JUNCTION BOXES TO MAKE 2 CONNECTIONS PER JUNCTION BOX. (SHIPPED LOOSE IN THE SET-UP KIT) 2. WIRE NUTS. 3. JUNCTION BOX COVERS. INSTRUCTIONS A. SECURE JUNCTION BOXES UNDER HOME. B. WIRES HAVE BEEN COLOR CODED; SIMPLY MATCH UP COLOR CO-ORDINATED WIRES WITHIN A JUNCTION BOX AND CONNECT WITH WIRE NUTS. C. PLACE COVERS OVER JUNCTION BOXES. OMITTED CEILING FIXTURES FIXTURES TO BE INSTALLED AT THESE LOCATIONS MUST BE A TWO WIRE FIXTURE WITH GROUND. INSTALL ALL FIXTURES BEFORE TURNING ON MAIN BREAKERS. HOT LEADS (RED & BLACK) CONNECTED TO MAIN BREAKER NEUTRAL (WHITE) WIRE TO NEUTRAL BUSS NOTE: SEE BELOW NO. 6 BARE COPPER GROUNDING FOR SERVICE ELECTRODE CONDUCTOR BONDED TO CONDUCTOR NEUTRAL BUS IN SERVICE PANEL, EXTEND SIZES TO GROUNDING ELECTRODE PER NEC 250-83 MINIMUM CONDUIT SIZES:- -v/ CONDUIT DROP FROM HOME - EXTEND 1 /2" MINIMUM - 150 AMP TO BELOW GROUND LEVEL OR SEE 2" MINIMUM - 200 AMP LOCAL CODES TYPICAL ELECTRICAL CONNECTIONS CROSS -OVER CONNECTIONS CROSS -OVER INFORMATION APPLIES TO MULTI -SECTION UNITS CROSS -OVER WIRES ARE COLOR -CODED SERVICE CONDUCTORS MAIN BREAKER HOT NEUTRAL GROUND 150 (2) NO. 1 NO. 1 NO. 6 200 (2) NO. 2/0 NO. 2/0 NO. 6 NOTE: ABOVE SERVICE CONDUCTORS ARE FOR COPPER ONLY. FOR COPPER -CLAD ALUMINUM REFER TO LOCAL CODES ELECTRICAL PANEL LABEL THIS LABEL IS LOCATED ON OR NEAR THE ELECTRICAL PANEL THE MINIMUM SIZE JUNCTION BOX ATTACHED TO THE CONDUIT FOR SERVICE CONDUCTORS ARE: 9" X 9" X 4" - 150 AMP OR 12" X 12" X 4" - 200 AMP ❑ - JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWNGS ARE DRAWN BY: D.M.T. DATE: 01-24-02 REV. LETTER: ❑❑■❑ P.O. BOX 368 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE: SET-UP/ELECTRICAL ❑„❑ SAFETY HARBOR, FLORIDA 34695 INC. SUCH MATERIALS ARE PROVIDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: ❑❑❑❑ PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS. SU-09-0001 1. 2. 3. 4. 4 ELECTRICAL CROSS -OVER ,--MARRIAGE LINE I I . 1 NOTCHED MARRIAGE WALL PERIMETER JOISTS — .92" DEEP NOTCH MAX. ELECTRICAL WIRING FROM ONE SECTION TO BE HOOKED —UP IN JUNCTION BOX(S) ELECTRICAL JUNCTION BOX(S) FASTENED TO TRANSVERSE FLOOR JOIST. ALL GROUND LEADS ARE SECURED TOGETHER AND BONDED TO THE JUNCTION BOXES W/ THE LARGEST SIZE CONDUCTOR IN BOX. (ALL REQUIRED JUNCTION BOXES ARE SNIPPED LOOSE IN THE SET—UP KIT) ALL ELECTRICAL WIRING CONNECTIONS TO BE MADE INSIDE LISTED JUNCTION BOX(S) IN COMPLIANCE WITH N.E.C. — 2005 WIRING IN LISTED JUNCTION BOX(S) NOT TO EXCEED CAPACITY OF THE JUNCTION-.BOX(S) PER N.E.C. — 2005. WIRING TO BE PROTECTED AND SECURED AT MARRIAGE WALL JOISTS WITH WIRE PROTECTOR PLATES INCLUDED IN SET—UP KIT. ELECTRLCAL CROSSOVER WIRING TO BE DONE ONLY BY QUALIFIED PERSONNEL. MATCHING IDENTIFIED CIRCUIT WIRING FROM EACH SECTION OF MULTIPLE WIDE HOMES. AFTER WIRING CONNECTIONS HAVE BEEN MADE, REPLACE COVER ON JUNCTION BOX(S), AND REPAIR ANY CUTS OR VOIDS IN THE. BOTTOM BOARD WITH DUCT' TAPE. DMA APPROVAL: APPROVED BY Revised INFAmay I 25,2006 II YC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS °1 JACOBSEN HOMES NOTICE`. UM SPECF1CATfONS AND DRAM ME DRAWN Or M.T. OAT A —05-25-06 REV. LEf(Fit P.O. BOX 368 DR MAI. PROPRIETARY, MD CM11081UIL OF sRE DRAWNG ¶TLC: ELECTRICAL CROSS —OVER B SAFEiY HARBOR. FLONDA 34695 SUGI RMME 70 ING INC.NC: SDCH YATFIClUS ARE Rta►�Eo To THE RECPEYT FOR SUM KRPOMS AND um BE DRAWNG NULI M PHONE (813) 726-1138 IDPT m+Fomix AND SECRET TROY anFxs $U-09-00� MOBILE HOME SET-UP/ELECTRICAL I -BEAM WIRE FROM BREAKER BOX TO GROUNDING TERMINAL #8 BARE COPPER WIRE MINIMUM OUTRIGGER GIRDLING WIRE MAY BE ATTATCHED TO ANY PART OF THE FRAME ASSEMBLY (NOT REQ'D TO BE ® OUTRIGGER). ANY APPROVED GROUNDING TERMINAL SECURED TO FRAME TO INSURE PROPER GROUND (METAL TO METAL CONTACT INSURED BY USING A STAR WASHER BETWEEN OUTRIGGER AND TERMINAL). TYPICAL ELECTRICAL GROUND NOTE: ALL EXPOSED NONCURRENT CARRYING METAL PARTS THAT MAY BECOME ENERGIZED SHALL BE EFFECTIVELY BONDED TO THE GROUNDING TERMINAL OR ENCLOSURE OF THE DISTRIBUTION PANELBOARD. A BONDING CONDUCTOR SHALL BE CONNECTED BETWEEN EACH DISTRIBUTION PANELBOARD AND AN ACCESSIBLE TERMINAL ON THE CHASSIS. NO. 8 BARE COPPER J' - L-APPROVED GROUNDING TERMINAL BOND WIRE (MINIMUM) ATTACHED TO OUTRIGGER OR I -BEAM (TYPICAL EACH UNIT). TYPICAL ELECTRICAL BONDING GROUNDING AND CONTINUITY TEST THE GROUNDING CONTINUITY TEST MUST BE PERFORMED BEFORE THE FEEDER CONDUCTORS ARE CONNECTED. PERFORM THE FOLLOWING TEST AFTER ALL STRUCTURAL ASSEMBLY, METAL AND TRIM INSTALLATION IS FINISHED: A. CONNECT ONE CLIP OF A FLASHLIGHT CONTINUITY TESTER TO A CONVENIENT GROUND (METAL SKIN, WINDOW FRAME ON METAL SKINNED UNITS, FLOOR DUCT RISER, SCREW HEAD ON RECEPTACLE OR SWITCH PLATE, ETC.) AND TOUCH THE OTHER CLIP TO EACH LIGHT FIXTURE CANOPY (WHERE LIGHT IS MOUNTED TO CEILING OR WALL). THE CONTINUITY TESTER SHOULD LIGHT IF EACH FIXTURE IS PROPERLY GROUNDED. B. REPEAT THESE PROCEDURES FOR ALL DIRECT WIRED APPLIANCES AND FIXTURES. C. USING THE SAME PROCEDURES, CHECK THE CONTINUITY BETWEEN THE FOLLOWING: 1. BETWEEN METAL ROOF AND STEEL FRAME. 2. BETWEEN METAL SKIN AND STEEL FRAME. 3. BETWEEN STEEL FRAME AND GAS PIPING. D. ANY LOSS OF GROUNDING CONTINUITY FOUND IN THE ABOVE WILL REQUIRE INVESTIGATION, CORRECTION, AND RETESTING FOR CONTINUITY. ❑❑❑❑ ❑❑■❑ORIGINAL, JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE PROPRIETARY, AND CONFIDENHAL DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: DRAWING TITLE: ❑„❑ P.O. BOX 368 MATERIALS Of MANUFACTURING INC. SUCH MATERIALSRIALS ARE ARE PROVIDED TO THE TYPICAL ELECTRICAL GROUND DRAWING NUMBER: SU-09-0020 ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 REOPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFlDENIIAL AND SECRET FROM OTHERS. I i EXTERIOR LIGHT FIXTURE INSTALLATION BE SURE ELECTRICAL SERVICE IS DISCONNECTED BEFORE COMING IN CONTACT WITH ELECTRICAL CONDUCTORS FIXTURE FLASHING RING f (THIN WHITE FIBROUS RING; I WHI-E (NEUTRAL) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER AND SECURED WITH WIRE NUT BLACK (HOT) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER AND SECURED WITH WIRE NUT I I I EXTERIOR ELECTRICAL BOX I - BARE (GROUND) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER AND SECURED WITH WIRE NUT I I EXTERIOR LIGHT FIXTURE (LISTED FOR EXTERIOR USE) I BEFORE ELECTRICAL SERVICE IS CONNECTED TO THE HOME, INSPECT THE EXTERIOR OF THE HOME AND LOCATE ALL THE EXTERIOR LIGHT LOCAT.ONS TO BE INSTALLED ON SITE. (ALL EXTERIOR LIGHT FIXTURES IN PORCH AND OTHER AREAS N )T ALONG THE EXTERIOR WALL AREAS OF THE HOME ARE INSTALLED AT THE FACTORY). THE EXTERIOR LIGHT LOCATIONS CAN BE I IDENTIFIED AS EXTERIOR ELECTRICAL BOXES IN THE WALLS USUALLY LOCATED ADJACENT TO EXTERIOR DOORS THAT ARE CO/ERED WITH BLANK (SOLID) COVERS. TO INSTALL THE EXTERIOR LIGHT FIXTURES, REMOVE THE BLANK COVERS FROM THE ELECTRICAL I BOXES AND FEED THE THREE WIRES (IDENTIFIED IN THE DETAIL ABOVE) THROUGH THE FIXTURE FLASHING RING BEFORE THE CONNECTIONS OF THE CONDUCTORS ARE MADE. THE FIXTURE FLASHING RINGS MUST EXTEND FROM THE OPENING OF THE ELECTRICAL BOX TO THE OUTERMOST EDGES OF THE EXTERIOR LIGHT FIXTURE (EXCESS AMOUNT OF THE FLASHING RING MA' BE TRIMMED OFF AFTER THE FIXTURE IS SECURED TO THE ELECTRICAL BOX). TO INSURE AGAINST THE POSSIBILITY OF AN ELECTRICAL SHOCK, ALL ELECTRICAL CONNECTIONS SHOULD BE DONE WITH THE ELECTRICAL SERVICE SHUT OFF TO THE HOV _. THE WIRE NUTS REQUIRED FOR SECURING THE WIRES WILL BE FOUND INSIDE THE ELECTRICAL BOX FOR THE FIXTURE (THESE WIRE NUTS ARE INSTALLED AT THE FACTORY TO CAP THE CONDUCTORS IN THE ELECTRICAL BOX). THE FIXTURE FLASHING RING IS LOCATED IN THE SHIPPING KIT INSIDE THE HOME. i ❑�❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: ❑❑.❑ORIGINAL. li AND DRAWINGS ARE PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: ❑��❑ P.O. BOX MATERIALS OF JACOBSEN MANUFACTURING SUCH MATERIALS ARE PROVIDED TO THE LIGHT FIXTURE INSTALLATION ❑ I ❑❑ FLORIDAINC. SAFETY HARBOR, ORI34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-09-0030 I MOBILE HOME SET-UP PLUMBING CONNECTIONS CHECK WATER AND DRAIN LINES FOR ANY CONNECTIONS THAT MAY HAVE COME LOOSE DURING SHIPMENT. SHOULD YOUR HOME NOT BE EQUIPPED WITH A MASTER SHUT-OFF VALVE, ONE MUST BE INSTALLED BETWEEN THE HOME AND THE WATER SUPPLY. THE WATER SUPPLY SYSTEM IS DESIGNED FOR A MAXIMUM INLET WATER PRESSURE OF 80 PSI. IF THE LOCAL WATER SUPPLY PRESSURE TO WHICH THE HOME IS BEING CONNECTED EXCEEDS 80 PSI, A PRESSURE REDUCING VALVE SHOULD BE INSTALLED TO LIMIT THE SUPPLY PRESSURE. WHEN HOMES ARE SET IN AREAS SUBJECT TO FREEZING THE EXPOSED WATER SUPPLY LINES MUST BE PROTECTED. AN ELECTRICAL RECEPTACLE IS LOCATED ON THE UNDERSIDE OF THE HOME NEAR THE WATER INLET, AND NEAR ANY CROSSOVER LOCATION WHERE THE WATER LINES ARE EXPOSED. THESE ELECTRICAL RECEPTACLES ARE FOR THE CONNECTION OF AN ELECTRICAL HEAT TAPE. HEAT TAPE USED MUST BE LISTED FOR USE WITH MOBILE HOMES. FOR MULTIPLE SECTION HOMES WITH PLUMBING IN MORE THAN ONE SECTION, LOCATE AND CONNECT THE WATER CROSSOVERS LOCATED UNDER THE FLOOR ALONG THE MARRIAGE LINE BETWEEN THE SECTIONS. TURN THE WATER SUPPLY ON AND CHECK FOR LEAKAGE. CAUTION: DO NOT TURN THE POWER ON TO THE WATER HEATER UNTIL THE TANK IS FULL OF WATER. CONNECT DRAIN DROP OUTS TO COMPLETE ALL FIXTURE DRAINS AND MAIN DRAIN. BE SURE ALL CONNECTIONS ARE MADE TO COMPLY WITH LOCAL PLUMBING CODES. GAS PIPING HOMES WITH GAS PIPING HAVE BEEN FACTORY TESTED FOR LEAKS, HOWEVER, BEFORE CONNECTING THE GAS SUPPLY TO THE SYSTEM ANOTHER PRESSURE TEST IS RECOMMENDED TO INSURE THAT THERE ARE NO LEAKS AFTER THE HOME HAS BEEN TRANSPORTED AND SET-UP. 1. CLOSE OFF ALL THE GAS APPLIANCE SHUT OFF VALVES. 2. ATTACH THE GAS TEST FITTING GAUGE. 3. PRESUREIZE THE SYSTEM UNTIL 3 PSI OF AIR PRESSURE IS REACHED. 4. PRESSURE MUST BE MAINTAINED FOR 10 MINUTES WITHOUT ANY INDICATED PRESSURE LOSS. CAUTION: DAMAGE MAY RESULT IF THE SYSTEM IS OVER PRESSUREIZED, THE GAS PIPING SUPPLY SYSTEM HAS BEEN DESIGNED FOR A MAXIMUM PRESSURE OF 14" WATER COLUMN (1/2 PSI) AND NOT LESS THAN 7" WATER COLUMN (1/4 PSI). THE GAS PIPING SYSTEM IS DESIGNED TO USE EITHER LIQUIFIED PETROLEUM GAS OR NATURAL ' GAS. BEFORE TURNING THE GAS ON: 1. BE SURE THE APPLIANCES IN YOUR HOME ARE DESIGNED FOR THE TYPE OF GAS BEING CONNECTED. 2. WHERE APPLICABLE ON MULTIPLE WIDE HOMES, LOCATE "QUICK -DISCONNECT" AND CONNECT. THE "QUICK -DISCONNECT" IS LOCATED UNDER THE FLOOR AT THE MARRIAGE LINE. 3. MAKE SURE ALL CONNECTIONS ARE TIGHT, AND ALL APPLIANCES ARE TURNED OFF. 4. AFTER THE GAS HAS BEEN CONNECTED AND TURNED ON, MAKE SURE ALL THE PILOT LIGHTS ARE LIT. ❑❑❑❑ JAC 0 B S E N HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: S.A. DATE: 3-22-95 REV: LETTER: ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: ❑,P.O. Pi BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROMDED TO THE PLUMBING CONNECTION + GAS PIPING SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: ❑❑ PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS Su-1 1 -0001 MOBILE HOME SET-UP SET-UP KIT PLUMBING FITTINGS Chi � II FITTING NAME: COUPLER 71SYMBOL I ORIENTATION / USE COUPLING PIPE SPLICING DIRECTION OF FLOW FITTING NAME: SANITARY TEE OL ORIENTATION / USE TEE HORIZONTAL TO VERTICAL ONLY FITTING NAME: LONG TURN 90' ELL YMBOL ORIENTATION / USE O' ELL MAY BE USED IN ANY ORIENTATION CHECK THE INSTALLATION INSTRUCTIONS FOR MATERIALS REQUIRED AND PLACEMENT OF FITTINGS, NOTE AS SHOWN IN THE DETAILS THE DIRECTION OF FLOW FOR FITTINGS. ALL PIPING REQUIRED TO FIT BETWEEN FITTINGS IS INCLUDED IN THE SET-UP MATERIALS. THE LENGTHS OF PIPE SHOULD BE CHECKED BEFORE CUTTING TO ENSURE THAT PROPER DROP-OFF IS REMAINING FOR COMPLETION OF PIPE RUNS. DRY FITTING ALL PARTS TOGETHER IS RECOMENDED BEFORE ANY FITTING AND PIPE JOINT IS GLUED. pa DIRECTION OF FLOW FITTING NAME: REDUCER BUSHING SYMBOL ORIENTATION / USE BUSHING REDUCE FITTING PIPE SIZE DIRECTION OF FLOW FITTING NAME: LONG TURN TEE WYE SYMBOL ORIENTATION / USE LTTY MAY BE USED IN ANY ORIENTATION SET-UP INSTRUCTION SYMBCLS O = 1 1/2" DROP O. = 1 1/2" DRY VENT O = 2" DROP 0 = 2" WET VENT O = 3" DROP O = 3" MAIN DRAIN - - - = 1 1/2" DRAIN LIN: m = 2" DRAIN LINE = 3" DRAIN ,LINE NOTE: USE A GOOD QUALITY CLEANER AND CEME IT LISTED FOR USE WITH PVC PIPING CONNECTIONS. BE S JRE TO FOLLOW THE MANUFACTURERS INSRUCTIONS ON THE COP TAINERS. ❑�❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS DRAWN BY: S.A. I DATE: 6-6-94 REV. LETTER: ❑ N❑ AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIUENTIAL DRAWING TITLE: ❑ ,❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE SET-UP KIT. PL. FITTINGS ❑ ❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-11-0010 MOBILE HOME SET-UP 2" WET VENT WITH NOT MORE THAN UNVENTED (1) FIXTURE DRAIN W.C. DROP3 r�' / / 2" 0 VENTED W.C. 3^ DROP / / / INDICATES BOTTOM 3" OF HOME �1 1/2" DRY VENT (SEE ALT. FOR OPT. WET VENT W.C. DROOPP UNVENT/ CONNECTION) / / 1 1/2" / 3" / O / i O3•• 3" D 3 3.. 3" TO ON SITE DRAIN CONNECTION O MINIMUM SLOPE 3" /� 1/8" PER FT. / WITH CLEAN -OUT / 1/4" PER FT. WITHOUT CLEAN -OUT TYPICAL 2" DROP / / 2" f INSTALL FULL SIZE 2" CLEAN -OUT IF SLOPE 3..2„ O S BETWEEN 1/8" & 1/4" PER FOOT USE O IF CLEAN - TYPICAL OUT IS NOT NEEDED 3" 1 1/2" DROP / / / / 1 1 /2" 1 1 /2" FITTING SCHEDULE OA VERT. TO HORIZ. (LONG TURN TY OR COMB. Y & 1/8 BEND) OB HORIZ. TO HORIZ. (LONG TURN TY OR COMB. Y & 1/8 BEND) © HORIZ. TO VERT. (1/4 BEND -LONG ELL) OD VERT. TO HORIZ. (LONG SWEEP 1/4 BEND) OE HORIZ. TO VERT. (SHORT TURN TY - SAN. TEE) TYPICAL ON SITE DRAIN CONNECTIONS 3/4" DROP FF WATER HEATI SECTION / / ,.,,-3/4" THREADED INLET 3/4" TEE AND FRESH WATER INLET FOR 3/4" THREADEE NOTE: INLET - FIELD SINGLE WIDES AND MULTI - THE TWO EXAMPLES SHOWN ARE INSTALLED WIDES WITH PLUMBING IN TYPICAL FOR MOST MODELS. ONE SECTION ONLY SOME MODELS DEPENDING ON THE PLUMBING LAY -OUT FRESH WATER INLET FOR MAY HAVE A COMBINATION MULTI-WIDES WITH OF BOTH OF THE EXAMPLES SHOWN. PLUMBING IN MORE THAN ONE SECTION TYPICAL FRESH WATER ENTRANCES '4" DROP 3/4" ELL (FIELDINSTALLED) ❑❑❑❑ JAC 0 BS EN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE: DRAIN SET-UP ❑"❑ P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-11-0005 FLOOR JOIST MAY BE NOTCHED AT PLUMBING CROSS -OVER (SEE ELECTRICAL SET-UP FOR SPECIFICATIONS). WATER LINE CROSS -OVER YY/91 ... VI\VJJ-V VL" (SEE DE TAIL BELOW) TYPICAL MARRIAGE LINE OF MULTIPLE WIDE HOMES TYPICAL FLOOR ASSEMBLY WATER CROSS -OVER R-7 INSULATION MINIMUM AND BOTTOM BOARD OVER WATER CROSS -OVER LINES NOTE: NO HEAT TAPE RECEPT. REQUIRED AT INSULATED WATER CROSS -OVER. 1. ICONNECT WATER LINES TOGETHER AT ALL CROSSOVER LOCATIONS. 2. INSTALL R-7 MINIMUM INSULATION BLANKET OVER THE WATER ICROSS-OVER LINES AND SECURE INTO PLACE WITH DUCT TAPE. 3. PLACE A PIECE OF BOTTOM BOARD MATERIAL LARGE ENOUGH TO �ICOVER WATER CROSS -OVER LINES AND INSULATION AND SECURE 0 FLOOR FRAMING MEMBERS WITH 1" X 1° X 16 GA. STAPLES INIMUM AT EACH FRAMING MEMBER, AND TAPE OVER SEAMS TH CLOTH DUCT TAPE OR EQUAL. III ❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWNGS ARE DRAWN BY: C.L.Y. DATE: 10-23-95 REV. LETTER: �El ;� ❑❑❑ P.O. BOX 366 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PRONDED TO THE REORIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. n H DRAWING TITLE: WATER CROSS -OVER DRAWING NUMBER: SU-11-0020 MOBILE HOME SET-UP 6. A.C. CONNECTIONS JACOBSEN MOBILE HOMES ARE MADE AIR CONDITIONER READY, WHICH MEANS THE REGISTERS, SUPPLY DUCTS, AND RETURN AIR FACILITIES ARE ALREADY INSTALLED IN YOUR HOME. IN A MULTI — SECTION HOME THERE IS ONE SUPPLY DROP PER SECTION, AND ONE RETURN AIR DROP FOR THE ENTIRE HOME. CONNECT THE RETURN AIR DROP TO THE INTAKE SIDE OF THE AIR CONDITIONING UNIT, AND CONNECT THE SUPPLY DROPS REDUCER "Y" FITTING(S) (i.e., (1) 12" TO (2) 10") TO THE BLOWER SIDE. FOR SINGLE UNIT HOMES, THERE IS ONE SUPPLY DROP, CONNECT THAT ONE DROP DIRECTLY TO THE BLOWER SIDE OF THE AIR CONDITIONING UNIT. ALL CONNECTIONS BETWEEN THE AIR CONDITIONER AND DROPS CAN BE MADE WITH INSULATED FLEXIBLE DUCT. CHECK THESE ITEMS AFTER THE AIR CONDITIONER IS INSTALLED. 1. ALL DUCT WORK BELOW THE HOME IS INSULATED. 2. ALL SEAMS ARE SEALED. 3. ALL CONNECTIONS ARE INSULATED AND TIGHT FITTING. UNIT IS SHC AND ONE RI WILL VARY I HAVE MORE un rtwtN JUrrLT UN RETURN DUCTS. (AIR HANDLER, CONDENSER, AND COMPRESSOR) TYPICAL DOUBLE WIDE A.C. CONNECTIONS NOTE: ON SOME MODELS THE SUPPLY AND/OR RETURN AIR DROPS PROVIDED ON THE HOME MAY BE LOCATED DIRECTLY OVER THE RUNNING GEAR (TIRE AND/OR AXLE). ON HOMES WITH THE DROP LOCATIONS LOCATED ABOVE THE RUNNING GEAR IT IS NECESSARY TO REMOVE THE RUNNING GEAR BEFORE HOOKING UP THE SUPPLY AND/OR RETURN AIR DUCT FROM THE AIR CONDITIONER UNIT TO THE HOME. NOTICE: DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: ❑❑❑❑ JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWINGS ARE ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MANUFACTURING DRAWING TITLE: ❑„❑ P.O. BOX 36B MATERIALS OF JACOBSEN INC. SUCH MATERIALS ARE PROVIDED TO THE DOUBLE WIDE A.C. CONNECTIONS 000❑ SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-13-0001 PHONE (727) 726-1138 KEPT MOBILE HOME SET-UP USE THE FOLLOWING INSTRUCTIONS WHERE APPLIED TO DUCTWORK PROVIDED BY JACOBSEN HOMES FOR AIR CONDITIONER INSTALLATION. CHECK THE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR ALL ADDITIONAL DUCTS USED DURING AIR CONDITIONER HOOK—UP FOR RECOMMENDED INSTALLATION PROCEDURES FOR THE TYPE DUCT BEING USED. 4ETHOD PRESSURE DETAILS LIMITATIONS APE ONLY (FOR LOW PRESSURE o )T TO EXCEED CONNECTING 2 IN. W.G.) 11 SP-ICING C EIAMP ONLY (METAL CLAMP (FORLOW TO BondCE M DIUM PRESSURE OT TO EXCEED4 IN. W.G.)SEE PRESURE L MITATIONS FOR PIL STIC CLAMPS** MIN. CONNECTING OR SPLICING TAIE &CLAMP (FOR LOW, MEDIUM OR (HIGH PRESSURE NOT TO EXCEED 1110 IN. W.G.) EE PRESURE CONNECTING LIMITATIONS FOR PL„STIC CLAMPS** SPLICING A) B) C) D) E) A) B) C) A) B) C) D) E) F) CONNECTIONS FOLD BACK JACKET AND INSULATION A) FROM END OF DUCT EXPOSING CORE. SLIP CORE OVER FITTING AT LEAST 8) 1 1 /2 INCHES. APPLY DUCT TAPE* AROUND CORE AND C) FITTING WITH AN EQUAL TAPE WIDTH ON EACH. PULL BACK INSULATION AND JACKET D) OVER FITTING. APPLY DUCT TAPE* AROUND JACKET E) AND FITTING WITH AN EQUAL TAPE WIDTH ON EACH. SLIP DUCT OVER FITTING AT LEAST A) THREE INCHES. PLACE CLAMP** AROUND DUCT AT FITTING AND TIGHTEN WITH APPROPRIATE TOOL UNTIL ALL MATERIAL UNDER CLAMP HAS BEEN COMPRESSED AND CLAMPING PRESSURE IS ASSURED. CHECK CONNECTION BY PULLING ON DUCT WITH A FORCE OF AT LEAST 25 LBS. TO INSURE DUCT HAS BEEN ADEQUATELY CLAMPED. PULL BACK JACKET AND INSULATION FROM END OF DUCT EXPOSING CORE. SLIP CORE OVER FITTING AT LEAST 1 1 /2 INCHES. APPLY DUCT TAPE* AROUND CORE AND FITTING WITH EQUAL TAPE WIDTH ON EACH. PLACE CLAMP** AROUND TAPE AND CORE AND TIGHTEN WITH APPROPRIATE TOOL. PULL BACK INSULATION AND JACKET AND APPLY DUCT TAPE* AROUND JACKET AND FITTING. WITH TABBED DUCTBOARD FITTINGS, OUTER JACKET MAY BE 'DIAPERED' INSTEAD OF TAPED (SEE STEP F). PULL JACKET OVER RING, THROUGH HOLE, AND FOLD UP WITH TABS. SPLICES FOLD BACK JACKET AND I'SULATION FROM END OF DUCTS EXP( SING CORE. INSERT ONE CORE INTO TFE OTHER ABOUT THREE INCHES. APPLY DUCT TAPE* AROUND OUTSIDE OF CORE EDGE WITH EQUA. WIDTH ON EACH CORE. BUTT INSULATION AND PU:_ JACKET FROM ONE DUCT OVER OT ER DUCT. APPLY DUCT TAPE* AROUND OUTSIDE OF JACKET EDGE WITH EQ' AL TAPE WIDTH ON EACH JACKET. FOLLOW AS DIRECTED UND R 'CONNECTIONS' BUTTING TV 0 DUCTS TOGETHER ON A STANDAR•. SHEET METAL COUPLING AT LEAS SIX INCHES IN LENGTH. A) BUTT TWO CORES TOGETHER ON A SIX INCH METAL COUPLING AN[ FOLLOW DIRECTIONS UNDER 'CONNE ;TIONS'. * DUCT TAPE: USE A MINIMUM OF ONE WRAP OF 2 INCH OR TWO WRAPS OF 1 1/2 INCH WIDTH OF TYPE SHUFORD #PC62�. TUCK #92T, ARNO #C520, POLYKEN #222, OR NASHUA #357. ** PLASTIC CLAMPS: PLASTIC CLAMPS ARE NOT RECOMMENDED FOR PRESSURES EXCEEDING 4 IN. W.G. (DIAMETERS 3" — 1, ") AND 2 IN. W.G. (DIAMETERS 12" AND OVER) TO ACHIEVE PROPER TENSIONING OF PLASTIC CLAMP, SE CORRESPONDING TOOL AT MAXIMUM TENSION SETTING. APPROVED TYPES: PANDUIT TYPE PLT—H (TOOL G); CATAMOUNT L-175 (TOOL L-300); OR TYTON T-150 (TOOL T-150). t[EH1111:10 1 ❑ORIGINAL, ❑ JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: — DRAWING TITLE: MOBILE HOME SET—UP DUCTWORK DRAWING NUMBER: SU-1 3-001 O ELECTRIC CLOTHES DRYER VENTING IMPORTANT - BEFORE DRYER IS USED IT MUST BE VENTED TO THE OUTSIDE OF THE HOME. THE VENT MUST NOT TERMINATE INSIDE THE SKIRTED AREA UNDER THE HOME, THIS WOULD RESULT IN EXCESSIVE HUMIDITY IN THE HOME. HOMES SET UP TO RECEIVE A DRYER ARE EQUIPPED WITH A VENT HOLE PRE -DRILLED THROUGH THE FLOOR AT THE DRYER LOCATION. TO COMPLETE THE DRYER EXHAUST SYSTEM, FOLLOW THESE PROCEDURES: 1. REMOVE THE DRYER VENT ACCESS HOLE COVER. 2. CUT DRYER VENT DUCT TO THE PROPER LENGTH, AND CHECK FOR OBSTRUCTIONS. THEN CONNECT TO DRYER IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. 3. SECURE THE VENT CAP TO THE OUTSIDE OF THE SKIRTING AT THE APPROPRIATE LOCATION. 4. SECURE THE END OF THE FLEXIBLE DRYER DUCT TO THE VENT CAP AT THE EXTERIOR OF THE HOME WITH CLAMPS. NOTE: DO NOT USE ANY SCREWS OR OTHER DEVICES THAT EXTEND INTO THE DUCT. 5. STRAP THE DRYER DUCT TO THE UNDERSIDE OF THE HOME TO PREVENT THE DUCT FROM COMING IN CONTACT WITH THE GROUND. 6. SEAL THE OPENINGS AROUND THE DUCT WHERE IT PASSES THROUGH THE FLOOR WITH CAULK OR DUCT TAPE, AND THE BOTTOM BOARD WITH DUCT TAPE. JACOBSEN HOMES WILL NOT BE RESPONSIBLE FOR DAMAGE TO THE HOME RESULTING FROM FAILURE TO INSTALL THE DRYER EXHAUST SYSTEM IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND THE INSTRUCTIONS LISTED ABOVE. NOTE: GAS DRYER INSTALLATION MUST BE DONE BY QUALIFIED PERSONNEL. THE CUTTING OF STRUCTURAL ELEMENTS OF THE HOME, SUCH AS RAFTERS OR FLOOR JOISTS TO EXPEDITE INSTALLATION IS PROHIBITED. ANY WEAKENING OF THE STRUCTURE RESULTING FROM SUCH CUTTING IS NOT THE RESPONSIBILITY OF JACOBSEN HOMES, AND MAY RESULT IN NEGATING YOUR WARRANTY. VSTALLED DUCT ;T BE METAL X OR RIGID CAP CAP NOTES: ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: R.R. DATE: 01-21-00 REV. LETTER: ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF SENARE MANUFACTURING DRAWING TITLE: DRYER VENTING n 1\ ❑„❑ P.O. BOX 368 MATERIALS INC. SUCH MATERIALS ARE PR041DED TO THE ELECT. CLOTHES '/ ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS. SU-15-0001 SITE INSTALLED WATER HEATER PAN DRAIN IMPORTANT - SET-UP OF THIS HOME REQUIRES THAT AN ON -SITE DRAIN BE INSTALLED FROM THE WATER HEATER PAN TO THE EXTERIOR OF THE HOME BEFORE THE WATER HEATER MAY BE USED. WATER HEATER PAN ACTORY INSTALLED UN THROUGH FLOOR 4D BOTTOM BOARD SITE INSTALLED DRAIN -A PIPE AND E=W , I' PER FOOT MIN. SLOPE) •.. wrra�nr., 4'-0- O.C. MAX. MATERIALS ARE PROVIDED BY THE MANUFACTURER. DRAIN TO EXTEND PAST THE EXTERIOR WALL LINE AND BE LEFT EXPOSED AND VISIBLE FOR IN$PECIXM, 1, (SEE DETAIL, 'A) SCREEN FACTORY INSTALLED BETAEEN PIPE AND ELBOW. THIS ASSEMBLY TO BE USED AS OVERFLOW PIPE TER% (NATION_ DETAIL ' 9 (DEALER IS RESPONSIBLE FOR THE SHIP LOOSE W/H PAN PIPE ON SITE INSTALLATION) 1.) ITE INSTALLED STRAPPING USED TO MAINTAIN THE RE4UIRIM SLOPE MAY BE SECURM TO FLOOR FRAMING AND/OR CHASSIS MEMBERS. 2) ///$HIIP LOOSE DRAIN LINE TO BE THE SAME MATERIALS AS THE FACTORY INSTA= W,4i PAN PIPE. MATERIALS FOR THE COMPLETION OF THE ON STE DRAIN WILL BE SHIPPED LOOSE. 36) E WATER HEATER PRESSURE AND TEMPERATURE RELIEF LINE MAY TERMINATE UNDER THE HOME NomJACOBSEN HOMES WOMIMS ARE "' _ III p1aWA. PROPp✓ my. " ooN"N. DRAWING TIRE P.O. BOX 368 U&TERIMS DF JACOM VAUNFAMM K M WIN" IN PItOMbfD TO ft II SAFETY HARBOR, FLORIDA 3095 REu1E11f f0t SUM RFNZ NO WE E DRAWING NUMBER PHONE M7) 728-1138 w l wrWIw No um IR one APPROVED BY INRevised Mar 12,2007 Ir IINC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS M.T. °' 03-08-07 lam"' Lf1nit W/H PAN DRAIN B- SU-15-0003 DOWN DRAFT RANGE VENTING IMPORTANT — BEFORE RANGE IS USED IT MUST BE VENTED TO THE OUTSIDE OF THE HOME. THE VENT MUST NOT TERMINATE INSIDE THE SKIRTED AREA UNDER THE HOME, THIS WOULD RESULT IN EXCESSIVE HUMIDITY IN THE HOME. HOMES WITH A DOWN DRAFT RANGE ARE EQUIPED WITH EXHAUST DUCT INSTALLED FROM THE RANGE THROUGH THE FLOOR, THE REMAINING DUCT IS SENT WITH THE HOME AND MUST BE INSTALLED ON SITE. 1. LOCATE DUCT DROP FROM RANGE. (MAY BE EXTENDING THROUGH BOTTOM BOARD, OR SEALED INSIDE) 2. CHECK DUCT PROVIDED FOR PROPER LENGTH, AND OBSTRUCTIONS. THEN CONNECT TO DUCT DROP FROM RANGE IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. 3. SECURE THE VENT CAP TO THE OUTSIDE OF THE SKIRTING AT THE APPROPRIATE LOCATION. 4. SECURE THE END OF THE DOWN DRAFT RANGE DUCT TO THE VENT CAP AT THE EXTERIOR OF THE HOME WITH CLAMPS OR SCREWS. NOTE: DO NOT USE ANY FASTENERS THAT CRUSH OR BLOCK THE DUCT. 5. STRAP THE DUCT TO THE UNDERSIDE OF THE HOME TO PREVENT THE DUCT FROM BENDING OR COMING IN CONTACT WITH THE GROUND. 6. SEAL THE OPENINGS AROUND THE DUCT WHERE IT PASSES THROUGH THE FLOOR WITH CAULK OR DUCT TAPE, AND THE BOTTOM BOARD WITH DUCT TAPE. JACOBSEN HOMES WILL NOT BE RESPONSIBLE FOR DAMAGE TO THE HOME RESULTING FROM FAILURE TO INSTALL THE RANGE EXHAUST SYSTEM IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, AND THE INSTRUCTIONS LISTED ABOVE. NOTE: DROP LOCATED DIRECTLY BELOW RANGE BLOWER MOTOR SITE INSTALLED DUCT i VENT CAP NOTICE: DRAWN BY: DATE: REV. LETTER: ❑❑❑❑ JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWINGS ARE S.A. I 6-6-94 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: Ht P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE DOWN DRAFT RANGE VENTING SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-15-000Z PHONE (727) 726-1138 PLENUM (DUCT DISTRIBUTION BOX) CEILING BOARD DUCT RISER(S) (SUPPLY DUCTS) AIR HANDLER CROSS -OVER CONNECTIONS CONNECTION BETWEEN CROSS —OVER SUPPLY DUCTS SHALL BE MADE PER OTHER DETAILS. UNIT MARRIAGE LINE AIR HANDLER CROSS -OVER ELEVATION VIEW PLENUM (DUCT DISTRIBUTION BOX) 000 JACOBSEN HOMES NOTICE: THESE sPEancAnoNs DRAWN 9Y: C.L.Y. DATE: — 3-21-95 REV. LETTER: ��■❑ P.O. AND DRANINGS ARE ORICINAL. PROPFUETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN LIAMIFACTMNC DRAWING 71 B 0�m0 BOX 368 ARE TO HANDLER CROSS -OVER 0000 SAFETY HARBOR, FLORIDA 34695 PHONE (013) 726-1138 RE� NTT FCH OR SPEC Sum BE IQrT CON WTML AND SECRET FROM OTHERS DRAWING NUMBER: SU-AC-0100