HomeMy WebLinkAboutENERGY EFFICIENCY CODEyi ! SCANNED Vl� Y FORM 05-10 FLO IIII IDA ENERGY EFFICIEP&Y CODE fOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ri Project ame: CEHELNIK RESIDENCE Builder Name: Street: it 10701 SOUTH OCEAN DR. #697 Permit Office: City, Sta e, Zip: JENSEN BEACH , FL , Permit Number: Owner. it Jurisdiction: Design Location: FL, West Palm Beach hl 1. New II struction or existing New (From Plans) 9. Wall Types (1200.0 sgft.) Insulation Area 2. Single amity or multiple fatuity Single family a. Concrete Block - Int Insul, Exterior R=4.1 1200.00 ftz b. N/A R= ft= 3. Number of units, if multiple family 1 c. WA R= ft� Bedrooms 2 d. N/A R= ftz 4. Numb ;r of 10. Ceiling Types (1488.0 sqft.) Insulation Area 5. Is thislworst case? No a. CathedraYSingle Assembly (Unvented) R=20.0 1488.00 ftz 6. Cond' toned floor area above grade (ftz) 1488 b. N/A R= fP it c. NIAucts R _ z Cond' ned floor area below grade (ft') 0 11 R ft 7. Windt, (261.0 sgft.) Description Area a. Sup: Main, Ret: Main, AH: Main 6 245 a. U- ,Iactor. Sgl, U=0.79 261.00 fh SF;GC: SHGC=0.50 12. Cooling systems kBtulhr Efficiency b. U- actor: N/A it= I a. Central Unit 29.0 SEER:16.00 S iGC: C. U;' actor: N/A S GC: 13. Heating systems kBtuthr Efficiency I U, Factor: NIA ft� a. Electric Strip Heat 27.0 COPA .00 S', GC: Area Weighted Average Overhang Depth: 2.000 ft. Area,WeightedAverage SHGC: 0.500 14. Hot water systems i a. Propane Tankless Cap: 1 gallons 8. Flo o Types (1488.0 sgft) Insulation Area EF:0.590 a. Slab-0n-Grade Edge Insulation R=0.0 1488.00 ftz b. Conservation features b- A R= fP None C. A R= fF 15. Credits Pstat II Total Proposed Modred Loads: 31.96 PASS Glas' Floor Area: 0.175 II Total Standard Reference Loads: 41.59 I hI;� y certify that the plans and specifications covered by Review of the plans and OtC-V0E S7,,gT�` this calculation are in compliance with the Florida Energy specifications covered by this v ,; Off, Cod II calculation indicates compliance- i i Mill with the Florida Energy Code. �?+„ ram, ..�;.•• �;,,, - �� � PR QAR E B Before construction is completed ---• - t7 DA E: r this building will be inspected for compliance with Section 553.908 _ l I he by certify that this building, as designed, is in compliance Florida Statutes. 1 'L J5 COD with the Florida Energy Code. WE 0 ' NER/AGENT: BUILDING OFFICIAL: DA DATE: ilE: 511:42 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 III I!I PROJECT Title: I; CE4IELNIK RESIDENCE Bedrooms: 2 Address Type: Street Address YP Building Type: User Conditioned Area: 1488 Lot # Owner: I Total Stories: 2 Block/SubDiivision: # of Units' 1 Worst Case: No PlatBook: Street: 10701 SOUTH OCEAN Builder tame: Rotate Angle: 0 Cross Ventilation: No County: MARTIN COUNTY Permit Office: 11n: Whole House Fan: Yes City, State, Zip: JENSEN BEACH, Jurisdicti FL Family TI' e. Single-family , New/ "' 'ng: New (From Plans) Commept: j CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp / V III Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, West Palm Beach FL_WEST_PALM_BEAC 2 44 90 70 75 316 60 Medium L BLOCKS NuAer - Name Area Volume 1 I Blockl 1488 11904 SPACES Nurliber Name Area Volume Kitchen Occupants Bedrooms InfillD Finished Cooled Heated 1 Main 1488 11904 Yes 4 2 1 Yes Yes Yes FLOORS III # Floor Type Space Perimeter R-Value Area Tile Wood Carpet I' I 1 Slab -On -Grade Edge Insulatio Main 187 ft 0 1488 ft2 0 0 1 III ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 I Hip Metal 1612 ft2 0 ft= Medium 0.96 No 0.9 No 20 22.6 I, ATTIC V l # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1488 ft2 N N I. CEILING Vill # Ceiling Type Space R-Value Area Framing Frac Truss Type iI- 1 Cathedral/Single Assembly (Unvented) Main 20 1488 ftz 0.11 Wood 11:42 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 w WALLS II Cavity Width Height Sheathing Framing Solar Belowo Adjacent S ace PR-Malue Ft In Ft In Area R-Valne Fra on 1 N Exterior Concrete Block - Int Insul Main 4.09999 41 8 328.0 ft2 0 0.75 0 _ 2 E Exterior Concrete Block - Int IllMain 4.09999 34 8 272.0 ft'0 0.75 0 _ 3 S Exterior Concrete Block - Int insul Main 4.09999 41 8 328.0 ft2 0 0.75 0 _ 4 W Exterior Concrete Block - Int Insul Main 4.09999 34 8 272.0 ft2 0 0.75 0 i DOORS # Omt Door Type Space Storms U-Value Ft Wig In Height Ft In Area 1 S Insulated Main None .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered. Proposed orientation. II Wall Overhang / V Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening i N 1 Metal Single (Tinted) Yes 0.79 0.5 80.0 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None N 1 Metal Single (Tinted) Yes 0.79 0.5 80.0 ft' 2 ft 0 in 6 ft 0 in Drapes/blinds None l�F3 E 2 Metal Single (Tinted) Yes 0.79 0.5 30.0 ft2 2 ft 0 in 6 ft 0 in Drapesiblinds None 4 E 2 Metal Single (Tinted) Yes 0.79 0.5 6.0 ft' 2 ft 0 in 6 ft 0 in Drapes/blinds None 5 E 2 Metal Single (Tinted) Yes 0.79 0.5 15.0 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None 6 S 3 Metal Single (Tinted) Yes 0.79 0.5 7.0 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None 7 S 3 Metal Single (Tinted) Yes 0.79 0.5 4.0 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None 8 W 4 Metal Single (Tinted) Yes 0.79 0.5 1.0 ft2 2 ft 0 in 6 It 0 in Drapesiblinds None 9 W 4 Metal Single (Tinted) Yes 0.79 0.5 6.0 ft2 2 It 0 in 6 ft 0 in Drapes/blinds None 110 I W 4 Metal Single (Tinted) Yes 0.79 0.5 32.0 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None li INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 W 'olehouse II Best Guess .0005 1951.6 107.14 201.49 .4247 9.8363 I HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP: 1 27 kBtulhr 1 sys#1 ! L-T COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 16 29 kBtu/hr 870 cfm 0.75 1 sys#1 .. it i 4/2 /2015 II 11:42 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 U GOO N Ow ww w10 w(O Q wP PP f0 O f0 W = d LL = p LL �p G C Om ww w{O CO iO COP PP w(O wW 0) zzz Z O) E " lCrK C C.)N W j d coon rr too(Do 00 000 n H U.0 O rn ow wco cow corn wP PP mm mw aaa V N � NfnN co tin rr o0 00 N 0 N d= OOCA a.-, o P �n nti ww Coco 0 (/� l0 �--•T, O w w cow corn coop PP PP ow (OHO W ~ M o) CD J } la0 (W).-• N 7 .7 ~ 7 7 7 b 0000 rr W F y COOW w(D a 2 o a 3 LL W O o d V, d� I W LL aTT rr rr mco Wo ~ N 07 c U ww ww cow o0 O R J J a¢Q -+--+=� N �p n000 nr �OWW two g AAA N N I rcwo rr o0 00 m N F- E m a� t0 0. o gg ¢a o c o o U Z o ecc 0 m LLJ ` o m d W —# 1yi(j Z ik co 'k 0 W 0 — 5 Lfcc d a U U = 14 FORM 10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ;: 10701 SOUTH OCEAN' DR. #697 PERMIT #: JENSEN BEACH, FL, REQUIREMENTS SUMMARY - See individual code sections for full details. COMP II NENT I SECTION SUMMARY OF REQUIREMENT(S) CHECK Air lea age 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete I envelope leakage report or visually verify Table 402.42. Therm star & 403.1 At least one thermostat shall be provided for each separate heating co �trols and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water eaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mech, finical 403.5 Homes designed to operate at positive pressure or with mechanical ve tilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swim ping Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of =1 & HP shall have the capability of operating at two or more speeds. Spas pas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Offltimer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooli' fg/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special e' uipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceili i l s/knee walls 1 405.2.1 R-19 space permitting. 4/23/20 5 11:42 AM I I EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 N. a 1. New coni 2. Single fart 3. Number 4. Number 5. Is this a 6. Conditio 7. Window' a. U-Fa1 b. C. d. Area W, Area W 8. Floor Tj a. Slab- b. N/A c. N/A ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 77 The lower the EnergyPerformance Index, the more efficient the home. 10701 SOUTH OCEAN DR. #697, JENSEN BEACH, FL, uction or existing ly or multiple family units, if multiple family Bedrooms rst case? 1 floor area (ft') Description r: Sgl, U=0.79 SHGC=0.50 r: N/A N/A NIA Average Overhang Depth: Average SHGC: de Edge Insulation New (From Plans) 9. Wall Types Insulation Area a. Concrete Block - Int Insul, Exterior R=4.1 1200.00 ft' Single-family b. NIA R= ft' 1 c. WA R= f? 2 d. NIA R= ftz 10. Ceiling Types Insulation Area No a. Cathedral/Single Assembly (Unvented) R=20.0 1488.00 ft' 1488 b. N/A R= ft2 c. N/A R= ftz Area 11. Ducts R ftz 261.00 ftT a. Sup: Main, Ret: Main, AH: Main 6 245 ftz 12. Cooling systems kBtulhr Efficiency fI2 a. Central Unit 29.0 SEER:16.00 ftz 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 27.0 COP:1.00 2.000 ft. 0.500 Insulation Area 14. Hot water systems Cap: 1 gallons R=0.0 1488.00 it= a. Propane EF: 0.59 R= fi2 b. Conservation features R= ft' None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on nstalled Code compliant features. Builder Address df New Home: Date: City/FL Zip: y��O�THE SrApFO� Sl: This is not a BuildingEnergy Rating. If our Index is below 70, our home may qualify for energy efficient J.9Y 9• Y Y Y q fY 9Y age (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 492 or seethe EnergyGauge web -site at energygauge.corrr for information and a list of certified Raters. For ation about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's 1ort staff. �ei required by Section 303.1.3 of the Florida Building Code, Energy Conservatio► Ip2t [ffA EnergyGauge® USA - FlaRes2010 Section 405.4.1 Comp