Project ame: CEHELNIK RESIDENCE
Builder Name:
Street: it 10701 SOUTH OCEAN DR. #697
Permit Office:
City, Sta e, Zip: JENSEN BEACH , FL ,
Permit Number:
Owner. it
Jurisdiction:
Design Location: FL, West Palm Beach
hl
1. New II struction or existing New (From Plans)
9. Wall Types (1200.0 sgft.)
Insulation Area
2. Single amity or multiple fatuity Single family
a. Concrete Block - Int Insul, Exterior
R=4.1 1200.00 ftz
b. N/A
R= ft=
3. Number of units, if multiple family 1
c. WA
R= ft�
Bedrooms 2
d. N/A
R= ftz
4. Numb ;r of
10. Ceiling Types (1488.0 sqft.)
Insulation Area
5. Is thislworst case? No
a. CathedraYSingle Assembly (Unvented) R=20.0 1488.00 ftz
6. Cond' toned floor area above grade (ftz) 1488
b. N/A
R= fP
it
c. NIAucts
R _ z
Cond' ned floor area below grade (ft') 0
11
R ft
7. Windt, (261.0 sgft.) Description Area
a. Sup: Main, Ret: Main, AH: Main
6 245
a. U- ,Iactor. Sgl, U=0.79 261.00 fh
SF;GC: SHGC=0.50
12. Cooling systems
kBtulhr Efficiency
b. U- actor: N/A it=
I
a. Central Unit
29.0 SEER:16.00
S iGC:
C. U;' actor: N/A
S GC:
13. Heating systems
kBtuthr Efficiency
I U, Factor: NIA ft�
a. Electric Strip Heat
27.0 COPA .00
S', GC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area,WeightedAverage SHGC: 0.500
14. Hot water systems
i
a. Propane Tankless
Cap: 1 gallons
8. Flo o Types (1488.0 sgft) Insulation Area
EF:0.590
a. Slab-0n-Grade Edge Insulation R=0.0 1488.00 ftz
b. Conservation features
b- A R= fP
None
C. A R= fF
15. Credits
Pstat
II Total Proposed Modred Loads: 31.96
PASS
Glas' Floor Area: 0.175
II Total Standard Reference Loads: 41.59
I hI;� y certify that the plans and specifications covered by
Review of the plans and
OtC-V0E S7,,gT�`
this calculation are in compliance with the Florida Energy
specifications covered by this
v ,; Off,
Cod II
calculation indicates compliance-
i i Mill
with the Florida Energy Code.
�?+„ ram, ..�;.•• �;,,, - �� �
PR QAR E B
Before construction is completed
---• - t7
DA E: r
this building will be inspected for compliance with Section 553.908
_
l
I he by certify that this building, as designed, is in compliance
Florida Statutes.
1
'L J5
COD
with the Florida Energy Code.
WE
0 ' NER/AGENT:
BUILDING OFFICIAL:
DA
DATE:
ilE:
511:42 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5
III
I!I
PROJECT
Title: I;
CE4IELNIK RESIDENCE
Bedrooms: 2
Address Type: Street Address
YP
Building Type:
User
Conditioned Area: 1488
Lot #
Owner: I
Total Stories: 2
Block/SubDiivision:
# of Units'
1
Worst Case: No
PlatBook:
Street: 10701 SOUTH OCEAN
Builder tame:
Rotate Angle: 0
Cross Ventilation: No
County: MARTIN COUNTY
Permit Office:
11n:
Whole House Fan: Yes
City, State, Zip: JENSEN BEACH,
Jurisdicti
FL
Family TI' e.
Single-family
,
New/ "' 'ng:
New (From Plans)
Commept:
j
CLIMATE
IECC Design Temp
Int Design Temp Heating Design Daily Temp
/
V
III Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
FL, West Palm Beach FL_WEST_PALM_BEAC 2 44 90
70
75 316 60 Medium
L
BLOCKS
NuAer
- Name
Area Volume
1 I
Blockl
1488 11904
SPACES
Nurliber
Name
Area Volume Kitchen Occupants
Bedrooms
InfillD Finished Cooled Heated
1
Main
1488 11904 Yes 4
2
1 Yes Yes Yes
FLOORS
III
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
I' I
1 Slab -On -Grade Edge Insulatio
Main 187 ft 0
1488 ft2
0 0 1
III
ROOF
Roof Gable Roof
Solar
SA Emitt Emitt Deck Pitch
#
Type Materials Area Area Color
Absor.
Tested Tested Insul. (deg)
1
I
Hip
Metal 1612 ft2 0 ft= Medium
0.96
No 0.9 No 20 22.6
I,
ATTIC
V
l
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0
1488 ft2
N N
I.
CEILING
Vill
#
Ceiling Type
Space R-Value Area
Framing Frac Truss Type
iI-
1
Cathedral/Single Assembly (Unvented) Main 20 1488 ftz
0.11 Wood
11:42 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5
w
WALLS
II
Cavity Width Height
Sheathing
Framing Solar
Belowo
Adjacent
S ace
PR-Malue
Ft In Ft In
Area
R-Valne
Fra on
1
N
Exterior Concrete Block - Int Insul Main
4.09999 41 8
328.0 ft2
0 0.75
0
_
2
E
Exterior Concrete Block - Int IllMain
4.09999 34 8
272.0 ft'0
0.75
0
_
3
S
Exterior Concrete Block - Int insul Main
4.09999 41 8
328.0 ft2
0 0.75
0
_ 4
W
Exterior Concrete Block - Int Insul Main
4.09999 34 8
272.0 ft2
0 0.75
0
i
DOORS
#
Omt
Door Type Space
Storms U-Value
Ft
Wig
In
Height
Ft In
Area
1
S
Insulated Main
None .46
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered. Proposed orientation.
II
Wall
Overhang
/
V
Omt ID Frame
Panes NFRC
U-Factor SHGC Area
Depth
Separation
Int Shade
Screening
i
N 1 Metal
Single (Tinted) Yes
0.79 0.5 80.0 ft2
2 ft 0 in
6 ft 0 in
Drapes/blinds
None
N 1 Metal
Single (Tinted) Yes
0.79 0.5 80.0 ft'
2 ft 0 in
6 ft 0 in
Drapes/blinds
None
l�F3
E 2 Metal
Single (Tinted) Yes
0.79 0.5 30.0 ft2
2 ft 0 in
6 ft 0 in
Drapesiblinds
None
4
E 2 Metal
Single (Tinted) Yes
0.79 0.5 6.0 ft'
2 ft 0 in
6 ft 0 in
Drapes/blinds
None
5
E 2 Metal
Single (Tinted) Yes
0.79 0.5 15.0 ft2
2 ft 0 in
6 ft 0 in
Drapes/blinds
None
6
S 3 Metal
Single (Tinted) Yes
0.79 0.5 7.0 ft2
2 ft 0 in
6 ft 0 in
Drapes/blinds
None
7
S 3 Metal
Single (Tinted) Yes
0.79 0.5 4.0 ft2
2 ft 0 in
6 ft 0 in
Drapes/blinds
None
8
W 4 Metal
Single (Tinted) Yes
0.79 0.5 1.0 ft2
2 ft 0 in
6 It 0 in
Drapesiblinds
None
9
W 4 Metal
Single (Tinted) Yes
0.79 0.5 6.0 ft2
2 It 0 in
6 ft 0 in
Drapes/blinds
None
110
I
W 4 Metal
Single (Tinted) Yes
0.79 0.5 32.0 ft2
2 ft 0 in
6 ft 0 in
Drapes/blinds
None
li
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 W 'olehouse
II
Best Guess
.0005
1951.6 107.14 201.49
.4247
9.8363
I
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat None
COP: 1 27 kBtulhr
1
sys#1
!
L-T
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Air Flow
SHR Block
Ducts
1
Central Unit
None
SEER: 16 29 kBtu/hr 870 cfm
0.75 1
sys#1
.. it
i
4/2 /2015
II
11:42 AM
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
Page 3 of 5
U
GOO
N
Ow ww w10 w(O
Q
wP PP f0 O f0
W
= d
LL
=
p
LL
�p G C
Om ww w{O CO iO
COP PP w(O wW
0)
zzz
Z
O) E
" lCrK
C
C.)N
W
j
d
coon rr too(Do 00
000
n H
U.0
O
rn
ow wco cow corn
wP PP mm mw
aaa
V
N
�
NfnN
co
tin rr o0 00
N
0
N
d=
OOCA
a.-,
o
P
�n nti ww Coco
0
(/�
l0
�--•T,
O
w w cow corn coop
PP PP ow (OHO
W
~
M
o)
CD
J
}
la0
(W).-•
N
7
.7
~
7 7 7
b
0000 rr
W
F
y
COOW w(D
a
2
o
a
3
LL
W O
o
d
V,
d�
I
W
LL aTT
rr rr mco Wo
~
N
07 c
U
ww ww cow o0
O R
J
J
a¢Q
-+--+=�
N
�p
n000 nr �OWW two
g
AAA
N
N
I
rcwo rr o0 00
m
N F-
E
m
a�
t0
0.
o
gg
¢a
o
c
o
o
U
Z
o
ecc
0
m
LLJ
`
o
m
d
W
—#
1yi(j
Z
ik
co
'k
0 W 0
— 5
Lfcc
d
a
U U
=
14 FORM
10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
;: 10701 SOUTH OCEAN' DR. #697 PERMIT #:
JENSEN BEACH, FL,
REQUIREMENTS SUMMARY - See individual code sections for full details.
COMP
II
NENT
I
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air lea
age
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
I
envelope leakage report or visually verify Table 402.42.
Therm
star &
403.1
At least one thermostat shall be provided for each separate heating
co
�trols
and cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water
eaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies
in Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to =
R-2 + accessible manual OFF switch.
Mech,
finical
403.5
Homes designed to operate at positive pressure or with mechanical
ve
tilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swim
ping Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of =1
&
HP shall have the capability of operating at two or more speeds. Spas
pas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Offltimer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooli'
fg/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
e'
uipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceili i
l s/knee walls
1 405.2.1
R-19 space permitting.
4/23/20 5 11:42 AM
I
I
EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software
Page 5 of 5
N.
a
1. New coni
2. Single fart
3. Number
4. Number
5. Is this a
6. Conditio
7. Window'
a. U-Fa1
b.
C.
d.
Area W,
Area W
8. Floor Tj
a. Slab-
b. N/A
c. N/A
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 77
The lower the EnergyPerformance Index, the more efficient the home.
10701 SOUTH OCEAN DR. #697, JENSEN BEACH, FL,
uction or existing
ly or multiple family
units, if multiple family
Bedrooms
rst case?
1 floor area (ft')
Description
r: Sgl, U=0.79
SHGC=0.50
r: N/A
N/A
NIA
Average Overhang Depth:
Average SHGC:
de Edge Insulation
New (From Plans)
9. Wall Types
Insulation
Area
a. Concrete Block - Int Insul, Exterior
R=4.1
1200.00 ft'
Single-family
b. NIA
R=
ft'
1
c. WA
R=
f?
2
d. NIA
R=
ftz
10. Ceiling Types
Insulation
Area
No
a. Cathedral/Single Assembly (Unvented) R=20.0
1488.00 ft'
1488
b. N/A
R=
ft2
c. N/A
R=
ftz
Area
11. Ducts
R ftz
261.00 ftT
a. Sup: Main, Ret: Main, AH: Main
6 245
ftz
12. Cooling systems
kBtulhr
Efficiency
fI2
a. Central Unit
29.0
SEER:16.00
ftz
13. Heating systems
kBtu/hr
Efficiency
a. Electric Strip Heat
27.0 COP:1.00
2.000 ft.
0.500
Insulation
Area
14. Hot water systems
Cap:
1 gallons
R=0.0
1488.00 it=
a. Propane
EF: 0.59
R=
fi2
b. Conservation features
R=
ft'
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on nstalled Code compliant features.
Builder
Address df New Home:
Date:
City/FL Zip:
y��O�THE SrApFO�
Sl: This is not a BuildingEnergy Rating. If our Index is below 70, our home may qualify for energy efficient
J.9Y 9• Y Y Y q fY 9Y
age (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
492 or seethe EnergyGauge web -site at energygauge.corrr for information and a list of certified Raters. For
ation about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
1ort staff.
�ei required by Section 303.1.3 of the Florida Building Code, Energy Conservatio► Ip2t [ffA
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Comp