Loading...
HomeMy WebLinkAboutBUILDING PLAN3/8' CONT. BEAD OF CAU.K BACK BEDDING) r0f TO PREVENT LIQUID PASSAGE 3/8' CONT. BEAD OF CAULK BACK BEDDING) BE34IND SHI <+ �•F TO PREVENT LIQUID PASSAGE ROOF EDGE � OF CAULK FLANGE A CONT. Ba I/4' IMAX) SHI nP WINDOW O ENTIRE FACE OF BUCK - /4' MAX SHIM SET FLANGE IN CONT, BED CF CAUJK A WINDOW v. ENTIRE FACE OF SHIM �- EMBED tt5 DOWEL 7- P.T. IX WOOD BUCK TO 1,: SILL CORROSIVE RESISTANT TAPCON CEMENTIOUS PERIMETER CAUx -C�NC. SCREWS INSTALLED AS SPECIFIED INTO FOOTING W/EPDXY FINISH BEYOND INTERIOR ..:.y FACE OF WINDOW OR S GD. + ' ' F PRECAST IN WINDOW MANI F. PRODUCT APPROVAL CONC. SILL O PERIMETER CAULK /2' DRYWALL _ O TTACH AS PE32 MANU=. EZ ATTACH P.T. BUC2CS PRODUCT APPROVALS CEvENTIOUS CONCJ3UKEXT. E O WAO99 X 1-1/7 NAI TYP. ALUMWINDOW FINISH ALL W/Itt5 VHRT V. A O AT 17 O.C. OR S.GD. JAMB AS IN FLOOR PLAN SEE TYPICAL WALL SECTION FOR FOOTING DETAILS °" . �,• I I O RIDGE 2 TYPICAL WINDOW E S.G.D. JAMB DETAIL AT C.B.S. WALL pip END O END NOTE GU NABLE SEALANTS SHALL COMPLY WITH ASTM C 92C CUSS 25 GRADE N5 TYPICAL PRECAST CON(. SILL DETAIL OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION NOTE GUT NABLE SEALANTS SHALL COMPLY WITH ASTM C 920 CLASS 25 GRADE N5 OR GREATE2 FOR PROPER JOINT EXPANSION AND CONTRACTION MISSED DOWEL DETAIL O O O j i1 APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED S14NGLE FASHION IN A 1 I� MANNER TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. THE FLASHING SHALL EXTEND TO TILE SURFACE OF THE (9) IOD X 1-1/2" EXTERIOR WALL FINISH. APPROVED STRAP TO TRUSS CORROSION-RLOCATIONS, FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATION ROOF EDGE I. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH 12803,23.1 SHEATHING FASTENINGS. OR TO THE WATER -RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. FLASHING AT WOOD STRUCTURAL PANE- SHEATHING SHALL EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH BE FASTENED To ROOF FRAMING WITH ED RING- ONE OR MORE OF THE FOLLOWING OR OTHE12 APPROVED METHOD: SHANK NAILS AT 6 INCHES ON CENTER AT EDGES � SIMPSON MTS 16 ATTACHE AND 6 INCHER ES ON CENTAT INTERMEDIATE FRAMING. 1.1 THE FENESTRATION MANI-FACTURERS WRITTEN FLASHING INSTRUCTIONS. SCANNED TO BLOCK W/(3)- 3/16' X 1-3/4' Z41NEJ RING IJM NK DIMENSIONS NAILS SHALLHAVE THE FOLLOWING1.2 THE FLASHING MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. BY TAPCONS MINIIvaIM DIMENSIONS, ZONE z 1.3 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200,012 St. Luci® c I. 0.113 INCH NOMINAL SHANK DIAMETER. ZQ F a 2 RING DIAMETER of o.012 ovez SHANK DIAMETER. 1.4 IN ACCORDANCE WITH THE FLASHING METHOD OF A REGISTERED DESIGN PROFESSIONAL TYPICAL CONC.BLK \- 2 AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR -' EXTERIOR WALL 3.16 To 20 RINGS PER INCH STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. )) 1 4. 0.280 INCH FULL ROLM HEAD DIAMETER. 3. UVDE32 AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. ST, I,I!e , P_OU`INTY Bitti,DING DIVISION 5.2 INCH NAIL LENGTH 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. REVIF,N'ED FAR COA1 'CE REVIE ROOF SHEATHING NAILING ZONES 5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL DATE WED BY PLAINS AND PER T MUST E KEPT ON JOB MISSING TRUSS STRAP DETAIL OR NO LNSPECTION WILL BE AL1DE. R702.4.1 GENERAL. CERAMIC TILE SURFACES SHALL BE INSTALLED IN ACCORDANCE WITH ANSI A108.1, A108.4, A108.5, A108.6, A108.11, A118.1, AI18.3. A136.1 AND AI37.1. 2702.4.2 CEMENT, FIBER -CEMENT AND GLASS MAT GYPSUM BACKERS. CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325 OR C 1178 AND INSTALLED WITH 1-1/4, WAFER HEAD, RUST RESISTANT DRILL OR SHARP POINT SCREWS AT 8' O.C. IN FIELD AND 4' O.C. AT EDGES, BACKING FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER AREAS, ON MIN. 2' X 4' WOOD FRAMING. REVISIONS DATED 06/08/2015 PROJECT ADDRESS REVISIONS DATED 06/08/2015 FIXED GLASS METAL ANCHOR FLANGE (4) BY MANUFACTURER WITH 1/4' X 3' STEEL BOLTS TO S''EEL PLATFOR T 'P. (4) PLACES CONDENSER UNIT MANUFACTURED STEEL FLATFORvI VJ!_1I! N.T.S. 'SIMPSON' SP6 AT EACH STUD, TO AND BOTTOM DBL TCP PLATE TX4'OR6' WOOD STUDS AT 16' O.C. P.T. WOOD BOTTOM PLATE T X 4'OR 6' P.T. WOOD STUD FILL CELL SOLID W/ CONC. CONCRETE BLOCK -4 e. e� : tt10 X AT 24' 4' TAPCONS O.C. VERT. ANCHOR BOLTS \-TYPICAL FOOTING AT 37 O.C. WOOD FRAME ATTACHMENT TO CONCRETE ST, LU IE COUNTY BUILDING DERARTMENT PRODUCT APPROVAL CHECKLIST PERMIT TYPE SPR. PERMIT NUMBER: OWES NAB, E�NIK RES DESIGN PROFESSIONAL NAME A/E JOHN H. CRESWELL, PE JOB SITE LOCATION: 10701 SOUTH OCEAN DRIVE #69 JENSEN BEACH, FL 34957 RULE 9 B-72 REQUIRES THE FOLLOWING INFORMATION AS PROMLRGATED BY THE FLORIDA BUILDING COMM ION, IN THE EVENT THAT INFOR TION IRED FOR PRODUCT APPROVAL HAS BEEN INCORPORATED IN TO TE PLANS, SPECIFICATIONS OR GENERAL NOTES, SIMPLY INDICA PAGE MBERS I T. PRODUCT MODEL NUMBER MANUFACTURER EVALUATION AGENCY NOA NUMB WINDOWS -SINGLE HUNG SERIES SH-7700 LAWSON IMPACT GLASS MIAMI-DADE 14-0908.10 EXPIRATION DATE DESIGN PRESSURES PSF) ALUMINUM TUBE LAWSON MIAMI-DADE 14-0908.08 12/27/2016 +/- 80 SLIDING GLASS DOOR SERIES SH-9200 LAWSON IMPACT GLASS MIAMI-DADE 14-0908.02 05/30/2017 + /- 150 WINDOWS -FIXED GLA DELI T. WINDOWS, ALL FIXED GLASS SERIES 4200/6200 LAWSON IMPACT GLASS MIAMI-DADE 14-0908.18 08/22/2017 +/- 78 -95 AWNING WINDOW AW2740/2840 PGT IMPACT MIAMI-DADE 11-1114.23 08/11/15 +75 -100 Is IORE EXTERIOR HINGED DOOR THERMA-TRU FLORIDA BUILDING CODE FL 5891.1NA +/- 67 ROOFING MATERIAL 5V-CRIMP J.M. METALS FLORIDA BUILDING CODE NA -114.25 K-13 AND CELBAR INTERNATIONAL MIAMI-DADE 10-0603.04 09/04/2015 ROOF INSLLATION SPRAY -ON CELLULOSE CELLULOSE CORP.1 +/_ p II v I.11 INSULATIONS HYDRO VENT 8' X 16' VENT SMART VENT PRODUCTS, INC FLORIDA BUILDING CODE FL 5822-122 NA 00 ORDANCE WITH THE FLORIDA ARCHITECTS AND ENGINEERS PRODUCT APPROVAL SYSTEM THIS AFFIDAVIT CERTIFIES THAT I HAVE PERFORMED THE BUILDING E VE'LOPE EVALUATION AS REQUIRED BY THE FLORIDA BUILDING CODE JOIN I-L CRESWELL, PE PE# 40940, COAU 27002 ARCHITECT/ENGINEER'S SIGNATURE FL CE12T,REG, NUMBIER DNS DATED 06/08/2015 INS./VENT NOTE: ALL MATERIALS USED BELOW BASE FLOOD ELEVATION MUST BE FLOOD RESISTANT. THIS INCLUDES ALL WALL COVERINGS IN GARAGE, AND ELSEWHERE IF APPLICABLE.. I"n TBERS OR ATTACHMENTS' THESE PLANS AND ALL PHOPO SE:r:RE0R'ONSI9ILlTY OFTHE AND SUBJECT TO ANY CORRECT s+. REQUIRED BY FIELD INSPEOiOR; wuNTRACtQROFRE�ARD MAY BE NECESSARY IN 090E' ST. LUCIE COUNTY COMPLY WI 111 ALL A7F.ICAN." PUBLIC WORKS DEPARTMENT CODE COMPLIANCE DIVISION 2308 VIRGINIA AVENUE FORT PIERCE, FL.. 34952 772-462-155 DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE GENERAL NOTES, I. CCNSTRUCTION SHALL FOLLOW 79-ORIDA BUILDING CODE' AS ADOPTED BY THE AREA IN WHICH THE BUILDING IS TO BE CONSTRUCTED WITH ALL APPLICABLE AMENDMENTS. 2. THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ETC. SHALL 3. ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE VERIFY ALL DIMENSIONS, CONDITIONS AT JOBSITE, PLANS, SPECIFICATIONS, ETC. OVER SCALED DIMENSIONS. 4, STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. STUCTURAL NOTES - I. DESIGN LOADS IN ACCORDANCE WITH FBC CHAP. 16 2 SOIL BEARING CAPACITY, 2500 PSF 3. ALL STRUCTURAL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. 4, SL.AB/FODTINGS TO BE CONCRETE WITH MINIMUM 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLANS FOR SIZE AND S"EEL REQUIREMENTS. 5. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTIPGS: 3' BEAMS, 1-1/7 SUSPENDED SLABS: I' 6. LAP ALL TEINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS. GRADE60 STEEL MINIMUM IN FOOTINGS AND SLAB. GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS. 7. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRIESURE TREATED. 8. SPLITTINGOR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTAL-ATION OF HARDWARE IS NOT PERMITTED. 9. UNLESS OHERWISE NOTED, THE INSTAIIATION OF SPECIFIED HARDWARE SHALL COW-ORM TO THE MANUFACTURERS INSTRUCTIONS AND STANDARD PRACTICE IO.BEARING PDINTS OF TRUSSES SHALL HAVE VERTICAL STUDS IN A NUABER EQUAL TO THE NUMBER OF PLIES OF THE / BEARINGMEMIBER WHEN THE BEARING MEMBER IS 2 OR MORE PLES UNLESS NOTED. OR 8D 121OG SHANK NAILS OR EQUAL 4' O.C. EDGES AND 6 O.C. IN FIELD II. ROOF SI EA -HIND TO BE NAILED WITH IOD GALV. 12PRAME TO I ASONRY SEGMENT CONNECTIONS, PT 2 X 4 MINIMUM TO MASC42Y WITH 1/7 DIAMETER 7 EMBEDMENT WEDGE BOLTS I AT TOP AND BOTTOM 36' OC TI-82EAF18 . 13.ALL SOILS TO BE COMPACTED TO MIN. 95% DENSITY 14.CORNER BARS ARE REQUIRED AT ALL OUTSIDE CORNERS 15POOTINGSSHALL BE A MIN OF 16' IN WIDTH OR AS INDICATE ON DRAWINGS 16120OF DL E LL - 55 PSF. 17LPLIFT FC2CES AS PER ENGINEERS NOTES AND SCHEDULES 18PL0012 U. - NA 19ALL PRE -CAST LINTELS TO HAVE MIR6' BEARING 20.ALL STANDARD 1 I p,FE12 SHALL BE SPF WITH A MINIMUM FB OF THIS CERTIFICATION MUST BE COMPLETED BY THe PROJECT DESIGNER, ARCHITECT OR ENGINEER. THIS CERTIFICATION MUST BE SUBMITLAD IN DUPLICATE WITH ALL APFUCATIOAS FOR BUILDING PERMITS INVOLVING THE CONSTRUCTION OF NEW RESIDENCE (SINGLE OR MULLTI-FAMILY), RESIDENTLuL ADDITION, ANY ACCESSORY STRUCTURE REQUIRING A BUILDIUG PERMIT AND ANY NONRESIDENTIAL STRUCTURE THIS CERTIFICATION SHALL NOT APPLY TO LNTE2102 NENOVATIONS (PROVIDED THAT NO EXTERIOR STRUCTURAL WALLS. COLUMNS OR OTHER COMPONETS ARE BEING AFFECTED) AND CERTAIN OTHER MINOR BUILDING PERMITS FOR FURTHER ASSISTANCE PLEASE CONTACT THE BUILDING INSPECTION OFFICE AT (772)462-2172 PROJECT NAME, CEHEUNIK RESIDENCE T_ PROJECT ADDRESS: 10701 SOUTH OCEAN DRIVE 4697 PERMIT NUMBER JENSEN BEACH, FL 34957 OCCUPANCY TYPE SF12 CONSTRUCTION TYPE CBS CERTIFICATION STATEMENT: I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOAD AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. DESIGN PARAMETERS AND ASSUMPTIONS USED (PLEASE CHECK OR COMPLETE THE APPROPRIATE BOX) 1. FLORIDA BUILDING CODE 2010 EDITION AND ASCE 7-10 2. BUILDING DESIGN IS: ENCLOSED: YES PARTIALLY ENCLOSED: OPEN BUILDING: 3 MEAN ROOF HEIGHT: LESS THAN 22' ROOF PITCHi 3/12 INTERNAL PRESSURE COEFICIENT. +/- 0.18 4. WIDTH OF END ZONES: < 4.5' WIND SPEED: 170 (3 SEC. GUSTS) 5. BUILDING CLASSIFICATION TABLE 1-I. ASCE 7 IE FBC TABLE 1604.5 6. WIND EXPOSURE CLASSIFICATION: D ADJUSTMENT FACTOR FOR EXPOSURE E HEIGHT: 1.61 7. COMPONENTS E CLADDING WIND PRESSURE ON ROOF ZONE 1 -41.9 2 -59.1 3 93.5 PSF 8. COMPONENTS E CLADDING WIND PRESSURE ON WALL ZONE 4 SEE 5 PLANS PSF 9. COMPONENTS E CLADDING WIND PRESSURE ON OVERHEAD GARAGE DOOR SEE PLANS PSF 10. LOADS: FLOOR 40 PSF ROOF/DEAD: 25 PSF ROOF/LIVE 30 PSF 11. SHEAR WALLS CONSIDERED FOR STRUCTURE? YES 2�_NQ ---sIF NO, ATTACH EXPLANATION) 12. CONTINUOUS LOAD PATH PROVIDED? YES X NO (IF NO, ATTACH EXPLANATION) 13. ARE COMPONANT AND CLADDING DETAILS PROVIDED? YES2L-NO IF NO, ATTACH EXPLANATION) 14. MINIMUM SOIL BEARING PRESSURE: 2500 PRESUMPTIVE: 2500 BY TEST: N/A PSF AS WITNESSED BY MY SEAL, 1 HEREBY CERTIFY THAT THE INFORMATION INCLUDED WITH THIS CERTIFICATIOM IS TRUE AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND BELIEF. NAME: JOHN H. CRESWELL, PE DESIGN FIRM: SLCCDV FORM# 020-00 REVISED 5/18/09 (CU CERTus PE# 40940. COA# 27002 DATE: SEAL FILE ME--12Y CONSTRUCTION INC. ALL DRAWINGS AND WRITTEN MATERIALS HE32EIN CONSTITUTE THORIGINAL AND WORK OF ME--RY CONSTRUCTION, INC. AND THE SAME OR ANY PART THEREOF MAY NOT SE DUPLICATED, DISCLOSED, DESTRIBUTED, OR USED IN ANY MANNER WITHOUT WRITTEN CONSEBJT OF MEL-RY CONSTRUCTION, INC., THE USER THEREOF, , WITHOUT CONSENT, BECOMES INDEBTED TO ME_-RY CONSTRUCTION, INC. FOR PULL COMMISION. R I GNT FLORIDA DESIGN CRITERIA V(UT) 170 MPH (3 Sec. GUSTS) V(ASD) 132 MPH (3 SEC. GUSTS) EXPOSU7E D IMPORTANCE FACTOR I CATE-GO Y II INTERNAL PRESSURE COEFFICIENT +/- 0.18 ROOF ZONE UP LIFT PRESSURES: ZONE 1 -41.9 PSF ZONE 2 -59.1 ZONE 3 -93.5 FOR ROOr PITCPS 2/12 TPRU 6/12 EXPOSURE "D" MULTIPLIER MEAN ROOF HEIGHT FACTOR LESS THAN 25' 1.61 4TED 12015 ,TION FIN. FL. 8' AFE. NO TRUSS CH, ADD 1-1/2' FACIA NO TRUSS OH. ADD HIT FACIA 5V-CRIIvP METAL ROOF lawil. #[-I- m N ♦m \rl `el 8'-I OPEN SPAN 3 1-1/2' I-1/T TRUSS CH. ) I-1/2' FACIA LINTEL AND BEAM BLOCK WAD #5 CONT. EA. CPS. L EXT. CONC WALL STEMWALL BEYOND STORAGEINDER SLAB TYPICAL FOOTING U) 6 w84 4 Q'm rn � U) %0 Q9a00m W Q p r > 00 m Z J J O` I o Lo —j GV N 0 uj n O W N �z 0 Wfy m�U 0 U- � = (1)UJ 0 d 7 LO tt O �a C� n Q CID v� W �v W zCC) ZW tL p O= Q W DfLu N� L o Z 0 Cr) rnn r- Q R L NOTE, ALL MATERIALS USED BELOW BASE FLOOD ELEVATION MUST BE FLOOD RESISTANT. THIS INCLUDES ALL WALL COVERINGS IN GARAGE, AND ELSEWHERE IF APPLICABLE.. Wgial MEL-RY CONSTRUCTION INC. ALL DRAWINGS AND WRITTEN MATERIALS HEREIN CONSTITUTE THORIGINAL AND WORK OF MEL-RY CONSTRUCTION, INC. AND THE SAME OR ANY PART THEREOF MAY NOT BE DUPLICATED, DISCLOSED, DESTRIBUTED, OR USED IN ANY MANNER WITHOUT WRITTEN CONSENT OF MEL-I2Y CONSTRUCTION, INC., THE USER THEREOF, WITHOUT CONSENT, BECOMES INDEBTED TO MEL-RY CONSTRUCTION, INC, FOR FULL COMMISION. FRONT ELEVATIONS 1/4" = I'-O" I I 1 r IVh " 5V-CRIMP METAL ROOF OVER 30tt FELT OVER 19/32 CDX PLY OVER• ENGINEERED ROOF TRUSSES 'SIMPSON' FETA20 EACH TRUSS TO BE 12 PITCH 3 IX4 AT TOP OF BOTTOM CHORD AT 8' O.C. AND. CONT. NAILED WAM 8D COMMiDN EA. TRUSS SEE SOFFIT E FACIA DETAIL CONTBEAM ELK WAI*5 CONT ATER PROOF CEILING CON, LI W/(I)e5 CONT I, BALCONY MAX DBL 7 X 8' P.T. RIM JOIST i W/(2) 5/8' DIA WEDGE ANCHORS AT 37 O.C. W/b' MIN EIv�EDIMBYf CONCRETE COLLMN IN CON, WAD tt5 VERT. 3/4' PLYWOOD DECKING CONT,BEAM ELK WAD#5 CONT. CON, LINTEL W/(I)n5 CONT. WATER CORETE COLUPNNI� \\'E9'NG. OP BEARING CEILING NC WAD tt5 VB7T. FLOO12JOISTS �--CONCRETE COLUMN ENDS 48 BADIVA M� R, PROVIDE PORCH CONT. LOAD PATH FROM FOOTING TO TOP OF BEAM JOMff W COL ELEV. AT AFE )ONcs.6a JkNLILD88 T NOTE SEE FLOOR PLANS FOR COLUMN LOCATIONS E C LINTELS PORCH/BALCONY DETAIL N.T.S. 5V-CRIMP METAL ROOF OVER 30tt FELT OVER 19/32 CDX PLY O 12 ENGINEER®PITCH H 'SIMPSON' f-ETA20 AT EA TRUSS TO BEAM WAIZ IOD XI-I/2, BEND AND NAIL BOTH SIDES SEE SOFFIT F� FACIA DETAIL CONTBEAM BLK WAD#5 CONT. I' USE CON, LINTEL ALL ALL EXT OPENINGS ML 7/8" CONCRETE BLOCK EXT. WALLS W/tt 5 VERT. AT W O.C. E EA SIDE OF EA - OPENING IN BLOCK WALL E AT ALL INSIDE E OUTSIDE CORNERS FILL SOLID WIC AT WEDGE ANC- CONT,BEAM W/(I)tt5 C CONCRETE BLOCK EXT. WALLS W/tt 5 VERT. AT 4 O.C. E EA SIDE OF EA OPENING IN BLOCK WALL E AT ALL INSIDE E OUTSIDE CORNERS LAP BAR ENDS 48 BAR, DIA MIN, PROVIDE CONT. LOAD PATH FROM FOOTING TO TOP OF BEAM TYPICAL 2 Y I/7 DRYWALL OVER R-4.1 FOIL OVER 1/2 P.T. FURRING AT 24' O., IX4 AT TOP OF BOTTOM CHORD AT 8' O.C. AND CONT. NAILED W/(3) 8D COMMON. EA TRUSS DBL 2' X 8' P.T. RIM JOIST WAD 5/8' DIA WEDGE ANCHORS AT 37 O.C. W/6' MIN EIvDEDIMENT IN CON, Y/7 TOP CHORD ENO. FLOOR AT 24' O., 1/2' DRYWALL OVER 9-4.1 FOIL OVER 1/2 P.T. FURRING AT 24' < m al JOINT rMCAL ELEV. AT APE. NAVD88 t if N I;z- m WALL N.T.S. TYPICAL WALL SEE WALL DETAILS AL DRIP FLASHING 'X6 PRIMED R.S. FACIA, 6" MAX O.H. ZERO OVERHANG DETAIL N.T.S. 4' CONC. SLAB GRADE SO. 31 tt5'S • N CONT i FILLAN CONC. O FOOTING 6' TYPICAL CONCRETE FOOTING FOUNDATION PLAN 1/4" = 1'-0" REVISION DATED CONCRETE NOTES 6/8/2015, CONC. PSI 4'CONC.SLAB W/6"X6-#10/#10 WWM OVER 6 MIL. VISQUEEN OR EQUAL OVER CLEAN COMPACTED ORGANIC FILL TO 95% DENSITY * SOIL OW SLAB TO BE TERMITE JFFO D PRIOR TO SLAB POUR * 1 MIN CONC W/VAPOR BARRIER * TING DESIGN BASED ON 2500(ASSUMED) IL BEARING CAPACITY, CONTRACTOR FY. PROVIDE MIN. 3/4' RECESS AND/OR SILL FOR ALL DOORS TO EXTERIORANCL GARAGED LINTEL SCHEDULE HIGH -STRENGTH PRECAST AND PRESTRESSED LINTELS MANUFACTURED BY CAST-CRETE SAFE APPLIED SAFE APPLIED Eil GRAVITY GRAVITY UPLIFT UPLIFT BEAM LENGTH TYPE LOAD LOAD LOAD LOAD COMPOSITE U 2'-10' PRECAST 6113 < 800 4460 < 400 8FI6-IB/IT L2 4'-0' PRECAST 6113 < 800 3079 < 400 8FI6-IB/IT L3 5'-4' PRECAST 5365 < 800 2290 < 400 8FI6-IB/IT L4 7-6 PRECAST 2661 < 800 1634 < 400 8FI6-IB/IT L5 10'-6' PRECAST 1533 < 800 914 < 400 8F16-IB/IT L6 la-6 PRECAST 184E < 800 1471 < 400 1 8FI6-IB/IT I. ALL BOND BEAM REINFORCING SHALL BE CONTINUOUS AROUND ENTIRE HOUSE PE32INJETE12 INCLUDING CHANGES IN BEAM ELEVATION. ALL SPLICES TO BE A MINIMUM OF 48 BAR DIAMETERS 2. CONCRETE FOR COLUMNS AND BEAMS SHALL HAVE 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS 3. A SINGLE FILLED CELL IS REQUIRED AT EACH SIDE OF EACH OPENING AND AT 6 FEET ON CENTER 4, 4 INCH MINIMUM BEARING IS REQUIRED FOR ALL UNITEI_S WHEN FILLED. LENGTH - OPEN SPAN PLUS 8 INCHES 2ND FLOOR PLAN 1/4" = 1'-0" CONCRETE BLOCK EXTERIOR WALLS WITH TYPICAL STUCCO FINISH NOTE, ALL MATERIALS USED BELOW BASE FLOOD ELEVATION MUST BE FLOOD RESISTANT. THIS INCLUDES ALL WALL COVERINGS IN GARAGE, AND ELSEWHERE IF APPLICABLE.. 'S PORCH STAIRS 'S PORCH STAIRS IST FLOOR PLAN 1/4" = 1'-0" CONCRETE BLOCK EXTERIOR WALLS WITH TYPICAL STUCCO FINISH MEL-12Y CONSTRUCTION INC. ALL DRAWINGS AND WRITTEN MATERIALS HEREIN CONSTITUTE THORIGINAL AND WORK OF MEL-12Y CONSTRUCTION, INC. AND THE SAME OR ANY PART THEREOF MAY NOT BE DUPLICATED, DISCLOSII=D, DESTRIBUTED, OR USED IN ANY MANNER WITHOUT WRITTEN CONSENT OF MEL-RY CONSTRUCTION, INC., THE USER THEREOF, WITHOUT CONSENT, BE --COMES INDEBTED TO MEL-12Y CONSTRUCTION, INC. FOR FULL COMMISION. s 0 U e z Q 3 J W JILT VTR / /2• — SING 1 / 2' 12' IJ wC r VTRJ L 3' LAV ` 1 WID r r I /-3' TO 2ND FLOOR I 1 JIL2' VTR /_2" LAV I I� 1 2. 3'1 1 3. - u �. 1 — �Wez 13. / ly 3' 14. 4' C/O I TO APPROVED SEPTIC SYSTEM IST FLOOR PLUMBING RISER N.T.S. JIL2' VTR SINK L rl � r SHOV 52 ` `I I1.,Ir v Y 3' `a �• �-3' FROM IST FLOOR 2ND FLOOR PLUMBING RISER N.T.S. 2ND FLOOR HVAC PLAN 1/4" = 1'-0' PROVIDE BALANCED AIR RETURNS IN ALL UNIT BEDROOMS LOAD CALCULATIONS RESIDENTIAL 150 AMP ELECT. PANEL 240- IC 3W CIRC. DESCRIPTION VOLT SIZE WATT RE SIZ 1.2 AC/AH 240 60 12,000 6 3A ANKLESS/ ON DEMAND 240 30 17000 10 5,6 OVEN/RANGE 240 50 12,000 6 7,8 DRYER 240 30 1,000 10 9 LIVING RM. 120 15 1,500 14 10 MASTER BEDRM. 120 15 1,000 14 II BEDRM.2 120 15 1,000 14 12 DINING RM. 120 20 1,000 12 13 LALINDQY/WASHER 120 20 11000 12 14 KITCHEN 120 20 2,000 GFI 15 BATI-4ROOMS 120 20 11000 GFI 16 SPARE 120 20 1,000 12 FIRST 10,000 - 10,000 51500 WATTS REMAIN. 41,500 AT 40%-16,600 TOTAL 26,600 AMPS - 26,600 / 240 - 110.8 AMPS ELECTRICAL LEGEND 1/2 ON SWITCH 110 V. RECEPTACLE In V. mcEF-rACLE (BE 220 V.SPECIAL PURPOSE OUTLET a FLOOR OUTLET 0 RED - AD1 EYEBALL IIOV WALL MOUNT LIGHT FIXTURE nOV FOR FD(T1. W(UGHT ,ETC) RECESSED LIGHT ® EXHAUST FAN/LITE COMBINTICN ® EXHAUST FAN CEILING FAN CEILING FAN W/ LIGHT SINGLE POLE SWITCH $3 DOUBLE POLE SWITCH 220 V. ECT CARBONN MONNOXIDE D MONOXIDE %"O E DETECTOR ROOD LIGHT �� DOOR OPENER FLUORESCENT LIGHT mi&Q ELECTRICAL PANE_ I] ELECTRICAL he7E2 TELEVISION JACK (CA A PHONE JACK SPEAlaRS GPI GROUND FALLT INTM WATERPROOF 1­1106E BIB IST FLOOR HVAC PLAN 1/4" = I' —On PROVIDE BALANCED AIR RETURNS IN ALL UNIT BEDROOMS ELECTRICAL NOTES: *200 AMP SERVICE *SMOKE DETECTORS AS REQUIRED *FIELD VERIFY RECEPTACLE LOCATIONS *GARBAGE DISPOSAL *ALL BRANCH CIRCUITS THAT SUPPLY 125V. SINGLE PHASE, 15 AND 20 AMP RECEPTACLE OUTLETS INSTALLED IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN "ARC -FAULT CIRCUIT INTERRUPTER(S)'. *RECESSED LIGHTING FIXTURES MUST COMPLY WITH: FLORIDA ENERGY CODE 606.I.ABC. 1.2.4. PRODUCT APPROVAL (TOTALLY ENCLOSED) 2ND FLOOR ELECTRICAL PLAN 1/4" = 1'-0" PER 200E N.E.C. TYPICAL ELECTRIC RISER 2�p � WI.�/23°V NOT T SCALE 20o AnaP AMP W/200 AW MAIN BREAKER MAIN DISCONNECT PA (30 CIRC.1 ELECTRIC METT32 (^ ^ 30AA Ypi-P I .O � AC TRArSFCQ1 (3) u2/O THI-N-CU BY PPL IN 2' CONDUIT 3#2/CL( IN T DIA. COM u4 SOLID OR STRANDED CU. GROUNDED TO (2Id5 REINFORCING BARS AT F(U•DATION BASE 2 GRNDRODS • E APART e2/0 LIFER GROUND REQUIRED T cmACU ON ROOF SEE ELEVATIONS FIND LOCATE =i 220 V. DISC IST FLOOR ELECTRICAL PLAN 1/4" = 1'-0" PER 2008 N.E.C. MEL-RY CONSTRUCTION INC. ALL DRAWINGS AND WRITTEN MATERIALS HEREIN CONSTITUTE THORIGINAL AND WORK OF MEL-RY CONSTRUCTION, INC. AND THE SAME OR ANY PART THEREOF MAY NOT BE DUPLICATED, DISCLOSED, L)ESTRIBUTED, OR USED IN ANY MANNER WITHOUT WRITTEN CONSENT OF MEL-RY CONSTRUCTION, INC., THE USER THEREOF, WITHOUT CONSENT, BECOMES INDEBTED TO MEL-RY CONSTRUCTION, INC. FOR FULL COMMISION. ��.ndi LIB O U z ) Q 0 i Ill BEARING HEADER SCHEDULE SIZE SPECIES NAILING OPENING JACKS FULL STUD (2)2X6 SPF STAGGERED ITOC 16D UP TO 3'-II (1) (1) (2>2X8 HEMP FIR STAGGERED ITOC 16D N TO 6' (D (U (2)2XI0 HEMP FIR STAGGERED 12'OC 16D 6'-I TO 8'-6 (2) (1) (2)2XI2 HEMP FIR STAGGERED 8'OC 16D 8'-7 TO 16' (2) (2) NON -BEARING HEADEQ SCHEDULE SIZE SPECIES NAILING OPENING JACKS FULL STUD (2)2X4 SPF STAGGERED ITOC 16D UP TO 3'-11 (D (1) (2)2X6 SPF STAGGERED 12'OC 16D N TO 9'-8 (1) (D HEADER T T I' MIN FROM EDGE AX 21 D FL FL JOISTS 12" MAX T X 17 STRINGERS ATTACH TO SIDE WALLS WA4) 16D EA. STUD 5 (3) 1/4' X 3' TAPCONS AT 16 O.C. TO CONIC. 15 RISERS AT 7.5" 14 TREADS AT 10" I" BULLNOSE ;*Xsf4 eg�� _ 'j SWING I X2' P.T FURRING I/7 DRYWALL FOIL I'X7 P.T I/7 FIR STRIP \DOO2 JAMB ATTACHED DRYWALL /tt10 X 3' WOOD SCREWS CAST •6 EAEND S 18' O.C.(SNGLIEAF) 9 12' O.C.(DBLLEAF) EXTERIOR SWING DOOR ATTACHMENT DETAIL RNDOW UNIT ADD (1) #5 OV62 4• LNG. FC)1POUR® w. CCNsc. NC. SILL _ = - - CONCBLKEXT. ALL W/Iu5 VERT l AS IN FLOOR PLAN u CONIC. WINDOW SILL DETAIL INTERIOQ) STAIR DETAIL METAL NFL PLYWOOD 25-1/2" 5V-CRIMP METAL ROOF PANEL ' 30# FELT 19/32" CDX PLYWOOD MOUNT �7 INDOW UNIT TAPER ADD O) ffi SILL OVER 4' LNG. vxo FORMED E POUR® CONG SILL - - - CONCBLKF:XT. ALL WARS VERT - - AS IN FLOOR PLAN CONC. WINDOW SILL DETAIL I ST FLOOR THICKEN CONC. UNDER BASE OF STAIRS WAN) tt5 CONT. 'XT P.T. BRING I X6 P.T. WINDOW BUCK ATTACI-® W/1-1/2' T NAILS • 18'O.C. VERT WINDOW FRAME ATTACHED TO CONC, BLOCK T RU WOOD WINDOW BUCK W/1/4' X 2-I1 TAPCONS, FILL ALL HOLES MIN EMBED 1-1/4' VP43 1/2=X PLY NAIL NAIL PATTI 2X6 FRAM? WALL- TYPICAL WALL SEE WALL DETAILS Iw P.T. Iw P.T. PERKING PERKING I/7 DRYWAL PX6' P.T. DOOR BUCK T�ATTA0-M WIFUZ T / NAILS • 18'O.C. VE12T SGO JAMB ATTACH W1#IO X 3-1/7 TAPCONS THRU DOOR BUCK AMID 1 CONCRETE BLOCK FILL ALL HOLES SCREW" SLPPLI® BY S.GD. MAN.F. INSTALL: AS PER MM1P. INSTRUCTIONS Sa ".t YPICAL FEADM SEV SCHEDULE 2X6 H?AZ-ACK sM HEADM FOR DETAILS S.G.D. JAMB ATTACHMENT DETAIL TYPICAL �2-19 INSLL LINER v1ETAL DRIP FLASHING -I"X2' P.T. DRIP EDGE 20X6' PRIMED R.S. FACIA 2 CONTRACTOR TO USE 7/8" STUCCO OVER 3/8' HI RIBBED PAPER BACKED ETAL LATH OVER -TYVEK' W/1' PER F.B.C. 2514.3.5, THE CONTRACTOR SHALL INSTALL 6' X 24' SOFFIT VENTS m 8'-0' O.C. TYPICAL SOFFIT DETAIL N.T.S. (SEE ZERO O.N. DETAIL, O LOT LINE) AL DRIP FLASHING 2"X6" PRIMED R.S. FACIA, 6" MAX O.N. TYPICAL WALL SEE WALL DETAILS ZERO OVERHANG DETAIL (0 LOT LINE) N.T.S. PNEUMATIC FASTNER SCHEDULE IJ PNEUMATIC FASTNERS SHALL BE 'HILTI' COIL NAILS, TYPE CRF 1120. I-1/2' LONG BY .120 DIAMETER UNLESS OTHERWISE NOTED. 2) FASTNERS OF EQUAL LENGTH AND DIAMETER MAY BE SUBSTITUTED FOR THOSE SPECIFIED. MANUF. MODEL tt SPACING/ LOCATION NAIL SIZE REMARKS PLYWOOD WALL 2-3/8' X .113 (34 DEG.) PRUDENTIAL SHEATHING BUILDING MAT. SP812MS SEE DIAPHRAM SCHEDULE PLYWOOD FLOOR 2-3/8' X .113 (34 DEG) PRUDENTIAL SHEATHING BUILDING MAT. SP8RMS SEE DIAPHRAM SCHEDULE I' X 2' FURRING .099 X I -VT SM INTERNATIONAL 422428 16O.C. STRIPS STAPLE WINDOW BUCKS .120 X 1-1/2' HILTI IT O.C. GARAGE DOOR 1/7 X 5-1/2' RAMSET/REDHEAD 24' O.C. VERTICALLY BUCKS DOOR BUCKS 1/4' X 2-1/2' INTERNATIONAL 8' O.C. TAPCONS STAPLE SLIDING GLASS .120 X 1-1/7 HILTI 17 O.C. DOOR BUCKS ROOF BASE 120 X I' CENCO HJI5ATA 17 O.C. AT HEAD LAPS AND EVE EDGES SHEET GALVANIZED 24' O.C. AT EDGE OF VALLEY SHEETS DIAPHRAM SCHEDULE PANEL FRAMING DIAPHRAM ZONE I ZONE 2 ZONE 3 EDGE INTER. EDGE INTER. EDGE INTER. LOCATION PANEL GRADE THICKNESS SPACING BOLNDERIES REMARKS ROOF APA RATED SHEATHING 19/32' 24' O.C. MAX IOD, 6' O.C. IOD, 6' O.C. IOD, 6' O.C. IOD, 6' O.C. IOD, 6' O.C. IOD, 4' O.C. IOD, 4' O.C. BLOCKING AS SHOWN EXPOSL12E I, OR EQUAL SPAN RATING 40/20 NOTE: ALL ROOFING NAILS TO BE RING SHANK NOTE TO GENERAL CONTRACTOR, ALL CONNECTIONS IN CONTACT WITH ACID MATERIAL SHALL BE HOT DIPPED GALVANIZED MINIMUM. NOTE TO BUILDER, BUILDER SHALL COORDINATE AND REVIEW ALL FINAL ARCHITECTURAL DRAWINGS WITH TRUSS MANUFACTURERS DRAWINGS BEFORE TRUSS MANUFACTURERS TRUSS ENGINEERING PACKAGES AND ACTUAL TRUSSES ARE PRODUCED. NOTES! I. HOUSE IS IN A NEGLIGIBLE WEATHER AREA 2. HOUSE IS IN A VERY HEAVY TERMITE AREA 3. FLAME SPREAD FOR WALLS AND CEILING FINISHES SHALL BE LESS THAN 200 4. FLAME SPREAD FOR INSULATION SHALL BE LESS THAN 25 5. SMOKE DEVELOPED INDEX SHALL BE LESS THE 450 FOR WALL FINISHES, CEILING FINISH AND INSULATION 6. GYPSUM BOARD SHALL CONFORM TO FBC R702.3 STANDARDS 7. TILE IN SHOWERS MUST BE BACKED BY "DURA ROCK" CONCRETE BOARD OR EQUAL RAILING FORCE PER CODE = 200# TOTAL OR 50 PLF 50 PLF - 4.17 /LI. ASSUME 4' TRIBUTARY AREA => TOTAL LOAD - 4.17WIN. X 4' = 16.7tt MOMENT AT BASE - 16.7# X 42' = 701# IN. SECTION MODULUS FOR WOOD = 1/6 BH2 (RECTANGLE) OR 1/6 63 (SQUARE) - 1/6 (23/16)3 = 0.5 IN3 BENDING STRESS = MIS = 701/0.5 - 1,402 PSI < 1750 PSI (FIBER STRESS FOR SYP.) I. AT TI E SAVE, RAKE AND RIDGE, FASTENERS SHALL BE AS PER F.B.C.2514.3.5 LOCATED NOT MORE THAN 3' AWAY FROM THE PANEL END. METAL AND WIRE LATH SHALL BE ATTACHED TO VERTICAL WOOD SUPPORTS WITH THE 70I INtt = I' FA + 3' FB 2 TI-E LEADING SIDE EDGE OF THE PANEL SHOULD BE TI-E EQUIVALENT OF 4D GALVANIZED OR BLUE COMMON NAILS DRIVEN TO A PENETRATION SIDE WITH THE ANTI -SIR -ION GROOVE, EACH PANEL SIDE OF AT LEAST 3/4 INCH (19 MM) AND BENT OVER TO ENGAGE NOT LESS THAN THREE WILL OVERLAP THIS CHANNEL TO PROVIDE A CAPILLARY BRAKE STRANDS OF LATI-L METAL AND WIRE LATH SHALL BE ATTACHED TO CEILING JOISTS OR B �N 701 IN#/ 4" = 175 tt 3. tt9-15 X HIT SELF DRILLING CORROSIAN RESISTANT FASTBNE2S OTH32 HORIZONTAL WOOD SLPPORTS WITH THE EQUIVALENT OF NO. II -GAUGE, W/ SELF SEALING WASI ®2S AT 17O.C. AND AT 12 O.C. IN TIE CENTER BARBED, GALVANIZED OR BLUED NAILS 1-1/2 INCHES (38 MM) LONG HAVING A ® A= PULL OUT FORCE = 175" OF TI-E PANEL AT THE FIELD PE2PENDICLLA12 TO THE ROOF SLOPE ON THE HEAD NOT LESS THAN 3/8 INCH (9.5 MMIN DIAMETER. 7 1 INtt ®B= PULL OUT FORCE = 525tt MAX HIGH POINTS OF TI-E PANE- RIBSA. THE PANEL'S WIDTH FASTENERS SHAD- SOFFIT VENTS TO BE 6'X24' AT 8' O.C. MAX BE SPACED AT 17 O.C. TO THE CENTER RIB, THEN IT TO THE NEXT, PERPENDICULAR TO TI-E SLOPE, THROUGH TI-E OVERLAPPING PANE-. TI-E FLAT EXTEf2I Oft SOFFIT DETAIL ttl2 WOOD SCREWS W/I-I/8' EMBEDIMENT HAVE WITHDRAWAL RESISTANCE OF 7 5tt > 525# AREA OF THE PANE. AS SHOWN IN TI-E DETAILS HEREIN 5. THE PANELS FASTENING PATTERN AT THE INTERIOR OF HANDRAIL LOAD CALCULATIONS THE PANEL, SHALL BE IN ROWS SPACED 17 O.C, RUNNING N.T.S. PARALLEL TO THE SLOPE OF THE ROOF. FL #6931-12I NOTE: ALL MATERIALS USED BELOW BASE FLOOD ELEVATION MUST BE FLOOD ME- RY CONSTRUCTION INC. ALL DRAWINGS AND WRITTEN MATERIALS HEREIN CONSTITUTE THORIGINAL AND WORK OF ME_-QY CONSTRUCTION, INC. RESISTANT. THIS INCLUDES ALL WALL COVERINGS IN GARAGE, AND AND THE SAME OR ANY PART THEREOF MAY NOT BE DUPLICATED, DISCLOSED, DESTRIBUTED, OR MANNER IN ANY MAER WITHOUT WRITTEN CONSENT OF ME -QY CONSTRUCTION, INC., THE US62 THEREOF, WITHOUT CONSENT, BECOMES INDEBTED TO ME.-RY CONSTRUCTION, INC. FOR FULL COMMISION. OR WD C0NT, 25 GAL16E METAL STUDS ATT O �TRACKS TOP E BOTTOM 24.0., 25 GAUGE CHANNE3_ SHAPED STUDS AT 2W O.C. W/ 1/7 GYPSUM WALL BOARD APPLIED VEWICALL.Y a ATTACHED W/ I' LONG BUGLE HEAD SCREWS TC EA. SIDE AT 12' O.C. CON, FLOOR SLAB TYPICAL INTERIOR PARTITION N.T.S. X 4' TOP PLATE 2' X 4' WOOD STUDS TAT 24' O.C. WITH 1/7 DRYWALL BOTH SIDES ATTACH 2' X 4' .BOTTOM PLATE TO FL. JOISTS WITH i310 X 4' WOOD SCREWS AT 4' FROM EA. END E 24' O.C., (3) MIN. OOR JOIST KNEEWALL DETAIL i 0 O z Zo Q a O 2 W ELSEWHERE IF APPLICABLE.. HETA 20 EA.R CUT 7/12 BIRDSMOUTH CONC. LINTEL W/BEAM BLOCK ABOVE W/(1) $*5 EA. CPS. CONT. CONC. COL. W/1=5 VERT 12 3 ------------------------------- co 2"X8" RAFTERS AT 16" O.C. "SIMPSON" HUS2-10 AT EA.RAFTER 12 TO LEDGER MIQ VA STORAGE ABOVE GARAGE --------------------- - — — — — 1 — — - { — — — — — — — — — — — — — — — — — — — T — — — — — — — — — — 16" X 18" CONC. FOOTING VV/3 =5'S CONT. 2"'X6"' CEILING BEAMS P19 1/2" DRYWALL CHASE 9,_3 1„ 2 2 STOPY LOAD � GOOF UPLIFT AT THIS POINT CA�2POf1T _ 1 8" X 1611 FO�),MFD E POU;:2FD i -� CONC. T I F BEAM VV/(2) =5'S CONT. AT TOP �(2):m7'S AT BOTTOM POUF ALL CONC. MONO d d a 4" CONC. SLA SIMPSON MST16 AT EA. TOP PLATE TO FLOOR JOIST SIMPSON SP4/6'S AT TEB PLATES AT EA. STUD 2"X8"LEDGER NAIL W/(2) 12D AT EACH STUD 2"X6" WOOD FRAME EXT. WALL CONT. LOAD TO CANTILEVER SLAI DOOR TO STORAGE FIELD DESIGN SIMPSON MST16 AT EA. TOP PLATE TO FLOOR JOIST SIMPSON SP4/6'S AT ALL TSB PLATES AT EA. STUD STRAP STUD TO STUD FD�ZIO LOSE ,. A. kfl 4 4 STOQAGF e d O' d a. d, d ° < A a a SECTION AT GARAGE STO;.),AGE 5/8" DIA. WEDGE ANCHOR AT 32" O.C. W/6" MIN EMBEDIMENT SUSPENDED C SLAB W/**5'S BOTH WAYS AT 12" O.C. CONT.=5 SLAB TO FOOTING D =5'S (TYP) CONCQFTF STFMVVALL VV/ 1 3:�5 AT 4' O.C. VF2T 24" X 16" CONC. FOOTING W/3 =5'S CONT. rn W H>m t N u-T QaQ . Z Q 0 c u m > c z I U D � u o i N O d O w Lua'10 z LLI Fn UyLL4 =n(Yo =�Dtt �a 7 C� ti O I Lov vz z-i W W UU oQ O�W LL W W ON tt 0, o0, LLI Z UJ p O= U) Lu :lQ W m OW Zp -1Co Lo co 0% 0% Co N co oj o WW ?ZW2U 0U00Q ~z < O NC4 m h 101 N.T.S. 0 *WARNING* ALL BEARING POINTS MUST BE INSTALLED PRIOR TO INSTALLING ANY TRUSSES! FAILURE TO DO SO MAY RESULT IN DAMAGED TRUSSES AND WILL VOID ALL WARANTIES. -THIS IS A PLACEMENT PLAN FOR ENGINEERED COMPONENTS AS DEFINED BY WTCA 1 - 1995. DIAPHRAMS HAVE NOT BEEN ANALYZED BY EAST COAST TRUSS. -FOR ERECTION AND INSTALLATION OF TRUSSES FOLLOW INSTRUCTIONS ON THE BCSI-B1 SUMMARY SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS -BRACING: WARNING* -SEE FINAL ENGINEERING SHEETS FOR THE 1) FOR THE ERECTION BRACING FOLLOW STRUCTURAL DATA, NUMBER OF GIRDER AND TRUSS INSTRUCTIONS ON THE BCSI-B1 SUMMARY SHEETS PLIES AND THE CONNECTION INFORMATION. 2) PERMANENT BRACING FOR THE STRUCTURE IS HE -OUR DESIGN DEPARTMENT MUST APPROVE RESPONSIBILITY OF OTHERS. ALTERATIONS AND/OR REPAIRS TO TRUSSES IN 3) INSTALL WEB BRACING AS STATED ON SEALED ADVANCE. ENGINEERING TRUSS DRAWINGS. -BACK CHARGES WILL NOT BE ACCEPTED UNLESS OUR DESIGN DEPARTMENT APPROVES THEM IN ADVANCE -ALL HANGERS ARE SIMPSON STRONG -TIE UNLESS OTHERWISE NOTED. INSTALL HANGERS ACCORDING TO THE CURRENT SIMPSON STRONG -TIE CATALOG TRUSS CONNECTOR SCHEDULE residence BRG P❑INT TRUSS I, TRUSS ,UPLIFT CONNECTOR MFG CONNECTOR QTY CONNECTOR TO USE CONNECTOR UPLIFT FASTENERS PER STRAP Truss to Concrete < 1725 S 1 HETA20 1805 10-1001 x 1-1/2 Truss to Wood < 625 U 1 RT7A 650 10-8d x 1-1/2 Connector Mfg U=USP, S=Sir)pson zero lot overhang N SIGNATURE ACKNOWLEDGES: Having used the Truss Loads (Provided by the Truss Manufacturer) for Design of Pertinent Components. No Responsibility is Hereby Assumed for the Dimensioning, Detailing, Fabrication Nor Installation of This Truss System. APPROVED BY: JOHN H. CPESWELL, PE TITLE: ENGINEER OF RECORD APPQOVAL DATE: line, no add 2x6 facia TRUSS PLACEMENT PLAN BEARING ELEVATION 8'-1 " E 9'-5-3/4" 17'-6-3/4" HANGERS A = U —24 : 2 B = HUS-26 : 1 TYPICAL END DETAIL HEEL HEIGHT 411 12" PLUMB CANTILEVER ROOF PITCH 3� ENGINEERED TIMBER TRUSS SYSTEMS PRODUC E17 EAST COAST TRUSS 5285 ST. LUCIE BLVD. FT. PIERCE, FL 349646 OFFICE:(772) 466-2480 FAX:(772)466-5336 CUSTOMER:Mel-Ry Construction JOB NAME: Cehelnik Res Up Roof ADDRESS:10701 South Ocean Dr # 697 CITY/COUNTY: Jensen Beach JOB # 28792 SQ FT 1045 DATE (LATEST=05/05/15 05/04/15 IN ACCORDANCE WITH THE RORIDA ADMINISTRATIVE CODE 1G15S-31.003 (3) (c), EAST COAST TRUSS is the Truss Design Engineer" .russa are designed In accordance with the lurid: Building Code NOTE: By approving this placement plan(s), signatured anywhere on this sheet, the customer or his representitive acknowledges that this placement plan complies with the structural intent of the project. The customer also acknowledges that this approval authorizes EAST COAST TRUSS to manufacture these trusses and deliver them to the project indicated on this drawing. The customer also acknowledges that he/she accepts financial responsibility for any repair, engineering, and labor required due to errors other than those of EAST COAST TRUSS. Signed MIX FOR 2110'6 12 DESIGN T4UTERIA =C&C Hybrid MWFRS OCCUPANCY CATEGORY= II EXPOSURE = D MWF SPEED = 170 BUILDING TYPE =ENCLOSED MEAN HEIGHT: 22 GRAVITY LOADS FLOOR: DUR FACTOR= 1.0 PS F =TC LL-TC D L- BC L L- BCD L 40.0120.010.015.0 ROOF: DUR FACTOR= 1.25 PSF=TCLL-TCDL-BCLL-BCDL 20.0115.0110.0,10.0 LOADS PER FBC & FRC *NON -CONCURRENT BC LL 10psf CONCURRENT BC DOTIOMM6L 20 psf MWF = MAIN WIND FORCE C&C = COMPONENTS AND CLADDING TOB = TOP OF BEARING TC = TOP CHORD S S�1 TQ EN=JSSES TRUSS ll wlaaG.LIIVEE�LO(A�Dp� A?L' GIRDEIi/COL'dM�Ct7A'D5 MUST EprsfAS&FR0WftD9 REE&S SHOWN SO0UfiftEM ffSS DRAWING. ST9Q®9kCING, 10'-0" O.C., IS RECOMMENDED ON FLOOR TRUSSES SPANNING 20'-0" OR MORE AUTION: SPANS GREATER THAN 30'-0" UST BE SET WITH A SPREADER BAR. THE PREADER BAR SHOULD BE AT LEAST 1/2 TO 1- 2- 3- 4- 5- 6- IN LENGTH AS THE SPAN OF THE TRUSS JG SET. =R TO BCI-B1 FOR COMPLETE CTION AND SAFETY PROCEDURES. ALL BEAMS BY BUILDER NOTE: TRUSSES DO NOT SUPPORT ANY PLANT SHELVES REVISIONS (1/4" if plotted 24x36) . Designed By: 0 LU CL G Q �U) UJ V/ Ln LU O LU Ln O z 4- 0 rl N Cn (0 i 0 U Z e z Q w J w CD Be a v Y c m S w 1L a In v CU N (" N w c c 0 R P U U E UI 0 x VI C W