HomeMy WebLinkAboutTRUSS PLACEMENT PLANe c i Y ,. W *WARNING* ALL BEARING POINTS MUST BE INSTALLED PRIOR TO INSTALLING ANY TRUSSES! FAILURE TO DO SO MAY RESULT IN DAMAGED TRUSSES AND WILL VOID ALL WARANTIES. -THIS IS A PLACEMENT PLAN FOR ENGINEERED -BRACING: WARNING* -SEE FINAL ENGINEERING SHEETS FOR THE COMPONENTS AS DEFINED BY WTCA 1 - 1995. 1) FORTH E ERECTION BRACING FOLLOW STRUCTURAL DATA, NUMBER OF GIRDER AND TRUSS DIAPHRAMS HAVE NOT BEEN ANALYZED BY INSTRUCTIONS ON THE BCSI-B1 SUMMARY SHEETS PLIES AND THE CONNECTION INFORMATION. EAST COAST TRUSS. 2) PERMANENT BRACING FOR THE STRUCTURE IS HE -OUR DESIGN DEPARTMENT MUST APPROVE -FOR ERECTION AND INSTALLATION OF TRUSSES RESPONSIBILITY OF OTHERS, ALTERATIONS AND/OR REPAIRS TO TRUSSES IN FOLLOW INSTRUCTIONS ON THE BCSI-B1 SUMMARY 3) INSTALL WEB BRACING AS STATED ON SEALED ADVANCE. SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS ENGINEERING TRUSS DRAWINGS. St ;H BY 9'-2". N. BEAMS/LEDGERS LA = DBL 2x-, TOP @ 9'-311 BBB = BEAM BY BLDR, TOP @ 9'-3" -BACK CHARGES WILL NOT BE ACCEPTED UNLESS OUR DESIGN DEPARTMENT APPROVES THEM IN ADVANCE -ALL HANGERS ARE SIMPSON STRONG -TIE UNLESS OTHERWISE NOTED. INSTALL HANGERS ACCORDING TO THE CURRENT SIMPSON STRONG -TIE CATALOG BEARING ELEVATION 8'-1 " f 9'-5-3/411 171-6-3/411 HANGERS D = HHUS-48 : 3 TYPICAL END DETAIL HEEL HEIGHT 4" ROOF PITCH 3F 1 1 ' 011 12" PLUMB CANTILEVER � II ENGINEERED TIMBER TRUSS SYSTEMS PRODUCTS rl O EAST COAST TRUSS r_1 5285 ST. LUCIE BLVD. FT. PIERCE, FL 349646 OFFICE:(772) 466-2480 FAX:(772)466-5336 to CUSTOMER: Mel-Ry Construction JOB NAME: Cehelnik Res Flr/Low Rf ADDRESS:10701 South Ocean Dr #697 CITY/COUNTY: Jensen Beach JOB # 28791 SQ E ( 1130 DATE LATEST=05/14/15 DATE 05/04/15 IN ACCORDANCE WITH THE FLORIDA ADMINISTRATIVE CODE 61GISS-31.003 (3) (o), EAST COAST TRUSS Is the "Truss Design ErglnseY' Trusses are designed in ac=da with the Flonda Buliding Code NOTE: By approving this placement plan(s), signatured anywhere on this sheet, the customer or his representitive acknowledges that this placement plan complies with the structural intent of the project. The customer also acknowledges that this approval authorizes EAST COAST TRUSS to manufacture these trusses and deliver them 0 to the project indicated on this drawing. W The customer also acknowledges that 0.he/she accepts financial responsibility for any repair, engineering, and labor required due to errors other than those of EAST COAST TRUSS. Signed: C - R6eASS— V J DESIGN L4UAERIA = C&C Hybrid MWFRS OCCUPANCY CATEGORY= II ' ^ EXPOSURE = D V, MWF SPEED = 170 W BUILDING TYPE =ENCLOSED J MEAN HEIGHT: 22.00 7 GRAVITY LOADS FLOOR: DURFACTOR= 1,0 W PSF=TCLL-TCDL-BCLL-BCDL , ^ 40.0120.010.015.0 (J� ROOF: DUR FACTOR= 1.25 PSF=TCLL-TCDL-BCLL-BCDL D 20.0115.0110.0110.0 0� LOADS PER FBC & FRC *NON -CONCURRENT BC f— LL 10psf LLI CONCURRENT BC 0 DOTIOR !6L 20 psf MWF = MAIN WIND UJ FORCE V) C&C = COMPONENTS D AND CLADDING TOB = TOP OF BEARING TC = TOP CHORD 0 $S�NN�QQses SSGiVE RUSS t6jj.���Iawlws.LIV��E((��L IO(A��D���� 0 �CL`GIRDEFPf0L17F1N'CO'AilS MUST 0 gYSfAS8:FR0k)1NW5' lE%S SHOWN JAUAft1rM PASS DRAWING. �1 1 2#6 STP9I[9R9ICING, 10'-0" O.C., IS RECOMMENDED ON FLOOR TRUSSES }- SPANNING 20'-0" OR MORE 1 CAUTION: SPANS GREATER THAN 30'-0" OI MUST BE SET WITH A SPREADER BAR. THE U SPREADER BAR SHOULD BE AT LEAST 1/2 TO 2/3 IN LENGTH AS THE SPAN OF THE TRUSS J BEING SET, Q I REFER TO BCI-B1 FOR COMPLETE 0 J ERECTION AND SAFETY PROCEDURES. Q ALL BEAMS BY BUILDER 0. z NOTE: TRUSSES DO NOT CL 1-4 SUPPORT ANY PLANT SHELVES Q REVISIONS 1-05-12-15: JC: ADDED FL10's 2-05-14-15: JC: REVISED rl STAIRWELL 4, 4- FILECOPY 6- TRUSS PLACEMENT PLAN (1/4" if plotted 24x36) . Designed By: