HomeMy WebLinkAboutSET-UP MANUAL ADDENDUMET=UP MANUAL ADDENDUM SCANNED BY Ise. Lre C100 IV ❑ter❑ JACOBSEN HOMES' 600 PACKARD COURT SAFETY HARBOR, FLORIDA (727) 726-1138 NOTICE specifications and drawings are original, proprietary, and confidential materials of en Manufacturing, Inc. Such materials are provided to the Mr; es and must be kept confidential and secret from others. REV 01/10 ALL HO.MES'SET IN FLORIDA MUST COMPLY WITH DMV RULE 15C EFFECTIVE MARCH 29,1999 For information on 15C. contact the Department of Motor Vehicles 850-413- 7600 1 ADDENDUM EXTERIOR HEATING/COOLING DUCT DUE TO THE NEW THERMAL REOUIREMENTS INSTITUTED BY HUD, THE INSULATION VALUES OF THE MANUFACTURED HOME HAVE INCREASED. IT IS NOW NECESSARY FOR ALL EXTERIOR DUCTS INSTALLED ON JACOBSEN HOMES HAVE A MINIMUM R-VALUE OF B. ALL HEATING AND/OR COOLING SUPPLY AND RETURN DUCTS EXPOSED DIRECTLY TO THE OUTSIDE AIR, SUCH AS UNDER CHASSIS CROSSOVER DUCTS OR DUCTS CONNECTING EXTERNAL HEATING, COOLING OR COMBINATION HEATING/COOLING APPLIANCES SHALL BE INSULATED WITH MATERIAL .HAVING A MINIMUM THERMAL RESITANCE OF R=8.0, WITH A CONTINUOUS VAPOR BARRIER HAVING A PERM RATING OF NOT MORE THAN 1 PERM. WHERE EXPOSED UNDERNEATH THE MANUFACTURED HOME, THE DUCT SHALL NOT HE IN CONTACT WITH THE GROUND, /DUCT SUPPLY OR RETURN DOLING SSOVER USE MINIMAL AMOUNT OF DUCT. LIMIT DUCT USAGE TO REDUCE THE AMOUT OF BTU/HOUR LOSS. DO NOT OVER BEND OR CRIMP FLEX DUCT, THIS WALL RESTRICT THE AMOUNT OF AIR FLOW THROUGH THE DUCT. USE STRAPPING OR OTHER MEANS OF SUPPORT TO PREVENT THE DUCT FROM COMING IN CONTACT WATH THE GROUND. PLACE STRAPS AS NEEDED TO SUPPORT DUCT (DO NOT RESTICT AIR FLOW BY OVER TIGHTENING SUPPORT STRAPS). ALSO SEE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR DUCT INSTALLATION AND SUPPORT. APPROVAL'oN TES. A�DAPIA PROVED BY M 1 5 T9�5 11PTINC NOTICE DRAIN BY. DATE: htV• ILVI IL ' JACOBSEN HOMES THESE SPECUTCATIONS AND DRANINGS ARE C.L.Y. 5-30-95 MONAL. PROPRR:TART, AND CpOWNTM DRATWNG TITLE: MATUtIALS OF JACOBSEN MANUFACI"G EXTERIOR A/C DUCT P.O. BOX 368 NG S" MAMWLS ARE PROVIDED TO THE SAFETY HARBOR. FLORIDA 34595 RECMT raR SPECnC PJ PM W IMT BE DRAMNG NUMBER: PHONE (813) 726-1138 PVT COWDDITIAL AND SECRET maI OTIFRS AD—AC-0001 .2 ADDENDUM WHOLE HOUSE VENTILATION SYSTEM YOUR HOME HAS BEEN EQUIPPED WITH A 'WHOLE HOUSE' VENTILATION SYSTEM. THIS SYSTEM HAS BEEN DESIGNED TO MEET ALL THE REQUIREMENTS SET FORTH BY THE UNITED . STATES DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT. THE WHOLE HOUSE VENTILATION SYSTEM IS REQUIRED (BY HUD) TO EXCHANGE AIR DIRECTLY WITH THE EXTERIOR OF THE HOME. THE PURPOSE OF THIS SYSTEM IS TO GIVE THE HOME OWNER THE ABILITY TO INTRODUCE FRESH OUTSIDE AIR INTO THE INTERIOR OF THE MANUFACTURED HOME, INSTEAD OF SIMPLY RE— CIRCULATING THE SAME OLD, STALE AIR THROUGHOUT THE HOME, THUS IMPROVING THE INDOOR AIR QUALITY. THE SYSTEM INSTALLED IN YOUR HOME HAS BEEN DESIGNED TO GIVE YOU COMPLETE CONTROL OF WHEN AND HOW THIS SYSTEM IS USED. YOUR HOME IS EQUIPPED WITH A FAN THAT WILL EXHAUST STALE INDOOR AIR (TO THE EXTERIOR OF THE HOME). THIS FAIN IS SWITCH CONTP.OLLED AND MAY BE MANUALLY OPERATED. TO DI�CCNT!"!UE USE OF THIS SYSTEM, SIMPLY 'TURN OFF' THE SWITCH THAT CONTROLS THE FAN. NOTICE TO HOMEOWNER Whole house ventilation switch You will be able to locate the switch that controls this fan by locating the switch that is labeled -WHOLE HOUSE VENTILATION. (See AD-AC-0100) DAN APPROVAL• APPROVED BY 1N14S`Y r O, INC. L790NLr�wNc7Y��pR 601111INNIMMO V0TlIWOMICi JACOBSEN HOMES »�� s��u»a�aRAwws CMS VKAhTf C.L.Y. 9-28-95 P.O. Box 368 AND AND ARE ofaaM, rff0pWtjMT'L MU OXWEU & YATCUM OF Jk'=Y UANUFACP"C DRAMWc TITLE- W.H. VENT. SYS. B bm SAFETY HARBOR, FLORIDA 34695 W_ sm Ymats ARC VRO M TO 1RC REafglf ►P�RaR 7WIC m AND NMI K DRArnHc MIYBER: PHONE (013) 726-1138 1VT C09MPA uD X00 may OTMn AD—AC-0100 ADDENDUM MULTI —WIDE UNIT FLOOR FASTENING 0.131' X 1 1 /1 MIN. / NAILS OR 7/16' X 16 GA. STAPLES PER TABLE: 0.016' X 1 1/2' MIN. STEEL STRAP 0 48' O.C. MAX. SPACING WITH FASTENING INTO JOIST EACH SIDE OF CENTER LINE PER TABLE BELOW: NDS01 (ALL ZONES) (ALL DOKWRES) n AM U11f.T FOR GAPS IN FLOOR SYSTEMS TO 1 /2', INCREASE LAG LENGTH 1' AND FOR GAPS TO 3/4'.INCREASE LAG LENGTH 1 1/2'. _ ., _ _ •- •--STALLED SEE CHART FOR MAXIMUM SPACING, STAGGERED FROM SIDE TO SIDE AT AN APPROX. 45' ANGLE FROM VERTICAL. SEE. DETAIL BELOW IF GAP EXISTS BETWEEN FLOORS. 1 4' TO 3 4' GAP WOOD SHIM AT ALL LOCATIONS FOR LAG SCREW THROUGH AND TO KEEP COI TIGHT. (SEE NOTE 2) 30 GA STRAP FASTM N/ WIN!" NLAIOER Cr FASMUS REQUYiii1 1MI�D WNE DRPOSURE 3/6' 13 1/i' TAG 9CAE'Jr MAX"ll SPACNG 7/14' X 16 GA. STAPLES MAXMLL SPAONG W00 ZONE DP09Ut1E 0.131' X 1 1/?r NAILS 7/1C X IS GA. iMn IV 0.C. 2 1/4' aC 3 S 2 2 b' 17' Or_ 1 7/MC O.0 b' 4 7 ti 1S' o.0 t ac 4 7 1 3 3 YY 8' Or_1 1/Y D.C. YI' S e NOTES: 1. 1' UK PiiMTICN 15 REQU4iED ON STAPLES FOR MDL O.OIC STRAP. L MOD SHMT9 TO 1E RIPPED FROM SPF p UK OR BETTER. Sr X 4' X GAP ■OTH MYL 9ZE) lOSB OR PLYWOOD MAY PL USED F VON= EQUALS GAP WIDTH-4' X 4' UDL 90 l 1Or UM" SIDEMALL HEIGHT. 4. SEE OTN ER DETAILS FOR SEALM FLOCKS FOR AIR KLTRAIDL _./r�3�-6 .John IC. �becfon, IRA=. ,K2 Enc Ting, !nc APPROVED BY Revised May 24,2006 INC. FEDERAL MANUFACFUREO HOME co%STRUCFION AND SAFETY STANDAFIDS MAW BY: DATE KY. LETTER JACOBSEN HOMES ,H1scNomm o,F,,.,�� AM M.T. OS-22-06 P.a eox 3sa Clomm. NARK AD mrFEonur. YA1u&4LS OF Ammo" Mm"AG1O1G DRAMLNG 11TLi M /W FLOOR FASTENING c IC 2101 MAIUM ME PFUMED 10 THE , SPH(326134E9S 8j726-13B �MFarm m DRAMNNu1BO PHONE IC0otA10 no OHM AD-FA-OW1 A ADDENDUM MULTI -WIDE UNIT WALL FASTENING ENDWALL NDS01 .131' X 3 1/2' MIN. NAILS 8' O.C. MAX. SPACING, STAGGERED FROM SIDE TO SIDE (TOE -NAILED). MARRIAGE LINE 1. FASTENING REQUIRED ONLY AT MARRIAGE LINE OF APPROVED aY EXTERIOR WAILS. S 23 O(5ON Revised Jahn C. Doeden, Rl�. K2 Engineering. ira . CWST INC. ta�srNb sasetr sr.ja.oms I JACOBSEN HOMES *m ma c►m= w DUN �' M.T. DA1� 05-22-06 �. Cr ��. Nhe DRANNB 11m. B PA Box 368 W. „a VAMW AM F A,K M/W WALL FASTENING SAfE1Y FIARBORFLORnA 34895 NEW is SM NA = No E DRAW MAM PHOK (813) 726-1138 gar mmr lft No =r nm OHM AD-FA-0010 5 ADDENDUM MULTI —WIDE ROOF FASTENING CENTER UNE OR MATING UNE OF TRIPLE WIDE UNITS 30 'GA. GALV. STEEL STRIP X SECURED WITH 7/16' X 16 GA. STAPLE$ FULL PENETRATION INTO OECKING (SEE CHART ON AD-FA-0001 MAX SPACING). 30 GA. GALV. STEEL STRIP .8' X LENGTH OF ROOF (SECTIONS MAY BE OVERLAPPED 2' MIN.) W/STAPLES AS SHOWN. INSTALL ROOF CAP PER SET- UP MAN. OVER GAL STRIP. I (30 GA. GALV. STRIPS USED MAY 13E WIND DEFLECTORS REMOVED FROM **LAG SCREW SET BACKS ROOF IN ORIGINAL CONDITION, FOR TRIPLE WIDES EXCEPT FOR STAPLE HOLES) FOR DOUBLE WOES PLAN w w xz 1 4' 2 3 4' 3/8' X S' LAG SCREWS AAuG Sf1tEW ME BACKS TRIPLE WIDE ROOF LINE (2 1/4' SMOOTH SHANK) FOR DOUBLE WIDES INSTALL LAG SCREWS SEE CHART ON AD—FA-0001 /'— FOR TRIPLE WIDES AT A 45' ANGLE I __� FOR MAXIMUM SPACING / STAGGERED 2 1 4 P34' 1 4' TO 3 4' GAP _ ROOF PERIMETER RAIL OR RIDGE BEAM (FOR RIDGE BEAMS SEE NOTE /4) CROSS—SECTION INSTALLWOOD SHIM AT ALL LI1G FOR GAPS IN ROOF SYSTEMS LOCATIONS FOR LAG SCREW TO GO FOR TO 1INCREASE LAG LENGTH 1' THROUGH AND TO KEEP CONNECTION AND FOR GAPS TO 3/4', INCREASE TIGHT. (SEE NOTE 2) NDS01 LAG LENGTH 1 1/2'. (ALL ZONES) CROSS—SECTION (W/GAP) c wa 91 0 - s1.07 (AOUES) I 1 NOTES: DICI i APPROVAL: DAM APPROVAL' L 2 Ile wL PEAIE1I aw N10 RECOMI C MGM IS RECMM FOR LAG SO MS 2 WOW SIM TO K RIPPED FROM SPF P UK OR KI I APPROVED BY 13' X 6' X GAP TN01H YN. SMI Revised ON 09 OR PLYYADOD MAY K USED IF 1HICJQIESS EQUALS WP MD1 4' X 6' MIX M* l SEE OTHER OETAI S FOR MIFLETIIG ROOF WMIECTIO L / S _ I Q� AMay24 , 2006 r 4. *lEX 11STALLNG A LAC SiilE11 KM A R M BEAM, FRST-M 3/fT John C. V0608n. P. � N C L A MEMMICE HOLE THROUGH THE FVW ROM TEAM. SECM-CRLL A 1/4' HOIE TF OCH THE ii? Enginwrh Rg, Inc . FEDERAL MANUFACTURED HOME 1ECF711NG RIDGE WM FOR TIE TIffJ M:D PCRTIOi OF LAG S' r I DUE DNS ARE CONSTRUQIDH AND SAFETY STANDARDS FOR 31e LAG SCAETES W&Y. S Itle MAMMF SMM1/1L MGTT. TO JACOBSEN HOMES TNT VEaETaA� wo MAW= AK oaAMH er M.T. DA1� 05-22-06 P.O. BOX 3sa CMUL mmwrwr. me mrzOmAL wIDW aF MUM MAIMAGAMC FVL SM WATINALS AK RVANZ TO RC � C 1w ORAMNG ARE: M f W ROOF FASTENING SAMW HARBOR. FLORIDA 34603 KWW FM WIMM A WO M AM HET N ORAWNG IMMMIt PHONE (613) 726-1135 Far CwmFut AN RM FXV VINOM AD-FA-0020 .0 METAL ROOF RIDGE CAP DOUBLE WIDE UNITS ONLY PLAN VIEW 29 GA. MIN. GALV. STEEL RIDGE CAP COVERING LENGTH OF ROOF (MR Y OVERLAP AT SEAM) SECURED WITH III X 711C HEAD X f FULLY THREADED SCREW AT EVERY RIB (AND ON BOTH SIDES OF RIB WITHIN END ZONE) SEALER STRIP BETWEEN RIBS OR CLOSURE STRIP RUNNING ENTIRE LENGTH OF ROOF Ref: EX-13-0051 and AD-FA-0020 NDS01 (ALL ZONES) (ALL ) CENTER OR MATING LINE r .I �88 X 7 16' HEAD X 2' j NIlY THREADED SCREW I (NO MORE THAN 12. O.C.) I •I . e 1 1 1 8 m m 1 � 1 ' 1 - 1 1 METAL ROOF PANELS STOP 1 APP. -3' FROM CENTER LINE "-30 GA. GALV. STEEL STRIP S' X LENGTH OF ROOF (SEE AD -FA -MD) SECURED WITH 7jAC X 16 GA. STAPLES FULL PENETRATION WTO DECKING (SEE CHART ON AD-FA-0001 MAX SPACING) SEE OTHER DETAILS FOR CONNECTIONS BETWEEN SECTIONS C STANDARD 7/1C O.S.B. (24/16 INDEX) ROOF SHEATHING. METAL PANELS ARE 29 GA. MIN. STEEL WITH 9' O.C. RIBS. SCREWS HAVE A NEOPRENE WASHER FOR WEATHER PROOFING AND TO HELP AVOID OVER DRIVING. IF SCREW IS OVER DRIVEN ANOTHER SCREW MUST BE ADDED BESIDE THE INEFFECTIVE SCREW (DO NOT REMOVE OVER DRIVEN SCREWS) c D)a j r. �F:Jl li 1'.r. go g, Inc, APPROVED BY Sep 10,2008 P1 INC. FEDHIAL YANIFACNI�D HOIff COMSIHDrnoM AND SaFE1Y STANDMDS JACOBSEN HOMESNmm ,� ,ms,,,o ow►das,rE """"" °" D.M.T. '""� �-25-OB �K �� TItE PA BOX 368 FETAL ROOF RIDGE CAP OK i� 9' PH= WIG Wi yMEM AK W&M 1D IM E zw m ((W j ao�mrm n ova m AD-FA-D021 ADDENDUM MULTI=WIDE ROOF SEALING/CLOSE-UP MIN. 30 GA. GALV. STEEL STRAPPING \ SEE AD-FA-0020) 6" STRIP ROOFING CEMENT RECOMMENDED OVER EDGES 15# FELT UNDERLAYMENT MULTI -WIDE ROOF LINE BEAD OF ROOFING CEMENT RECOMMENDED EACH SIDE PROVED BY 1. 30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). JIA 1 5 M INC 7 THESE SKOMA1IONSAND DRAWNGS ARE DRAYM BY: C.L.Y. DATE: 6-5-95 REV. LE cR JACOBSEN HOMES ■ P.O. BOX 368 OMm+AL, PROPWARY. WTFRIAND AIS Cf JACOBSEN AAUFACILMG RAIG oRAwwc nTIE M/W ROOF SEALING SAFETY HARBOR. FLORIDA 34695 PHONE (813) 726-1138 NC SUCH MAMMALS ARE PROYM 1D THE RECPENT M SPECM "MOM NO 4US1 BE IVT CDNUMTIAL AID moo nim OTTERS DRAWING NUUBER AD-FA-0025 8 ADDENDUM MULTI -WIDE. ROOF SEALING/CLOSE-UP MIN. 30 GA. GALV. STEEL STRAPPING (SEE AD-FA-0020) • 6" STRIP ROOFING CEMENT RECOMMENDED OVER EDGES - LOW SIDE 30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). 6" STRIP ROOFING CEMENT REQUIRED OVER EDGES -HIGH SIDE / 15# FELT UNDERLAYMENT MULTI -WIDE ROOF LINE BEAD OF ROOFING CEMENT (2 BEADS REQ'D HIGH SIDE 1 BEAD RECOMMENDED ON THE LOW SIDE) DAPIA APPROVAL 'ROVED BY JW 1 5 W5 INC. clim"SWIMUMDUM JACOBSEN HOMES NOTICE DRAWN BY: DATE: REV. LETIYR: 1Hess sa�alunons Arm oRAwms ARE C.L.Y.. 6-5-95 A MATWIALSP TCOeSEr� UNMAC1"O DRAWWc nTLE P.O. BOX 368 we 9" YATEM&S ARE P��y TO TK M/W ROOF SEALING SAFETY HARBOR, FLORIDA 34695 KOPQIT rOR SPECIFIC H. WM NO YA1 K DRAWING HUYBER: PHONE (813) 726-1138 IVT WWTu1 NO 100 n= OTIM AD—FA-0026 SHIPPED LOOSE HEARTH EXTENSIONS TYPICAL WALL HEARTH. 1N3TAILA IlK 1. REMOVE ANY CARPET AND/OR PAD FROM UNDER THE HEARTH EXTENSION AREA 2. INSPECT THE META FIASITNG IN THE HEARTH AREA TO INSURE THAT IT HAS BEEN 167A M (THIS FLASIM MUST BE PLACED ON THE FLOOR TO PROTECT THE AREA BETWEEN THE FIREPLACE AND THE HEARTH I LOCATE THE HEARTH EXTENSION (SHIPPED LOOSE N THE HOME) AND INSTAL FOLLOMING THESE SIM A. CAREFILLY PLACE THE HEARTH EXTENSION N THE PROPER LOCATION N FRONT OF TTEE FIREPLACE ASSERY. B. SECURE THE HEARTH EXTENSION TO THE FLOOR W/ 4 18 x 2' WOW SCREWS C. FILL IHE AREA BETWO THE FACE OF THE FOULACE AND THE HEARTH EXTENSION METH A NON-COMBUSTABLE CAWGIG OR MORTAR. D. OR FOLLOW THE HEARTH MANUFACTURERS INSTRUCTIONS FOR INSTALLATION. TILE SURROUND WOOD TRIM TYP. HEARTH FACTORY INSTALLED FLASHING (MAY BE SHIPPED LOOSE) 1. A TYPICAL TILE FRONT FIREPLACE IS SHOWN, HOWEVER THIS DETAIL APPLIES TO ALL FACTORY INSTALLED FIREPLACES. (STONE, WOOD, GYPSUM, ILE, STUCCO, ETC... MAY BE USED IN LIEU OF THE TYPE OF FIREPLACE SURROUND SHOWN ABOVE.) APPROVED BY jw 2 8 w INC ROfA1l W W VACiIR®IOt J AC O B S E N HOMES too s MD DRAWN BY:. DAIS ilEvc LETTER: THESE sPEalunan AND DRAraNa ARE C.L.Y. 6-16-95 ■ aaONAL. PROPRIETARY, AND OOWIMTK DRAWING TITLE- m P.O. BOX 368 � „A� PMM T T� SHIP —LOOSE HEARTH SAFETY HARBOR, FLORIDA 34695 REOPENT MR 7= PIAP M N O "I K DRAMNG NUMBER PHONE (813) 726-1138 JUT oOrFW114 AIO SEQV IRON ODDS AD—FP-000I lU SMOKE ALARM ADDENDUM Enclosed in the home owner's packet is the smoke alarm user's manual, (if it is not there, contact Jacobsen Homes and one will be sent to you. NOTICE TO DEALER AND SET-UP PERSONNEL This home is equipped with a smoke alarm system and must be tested in accordance with the smoke alarm user's manual after the home is completely set-up and all the electrical connections are done. NOTICE TO CUSTOMER Smoke Alarms have been installed in your Jacobsen Homes. You should be familiar with the locations and operation, and learn how the alarms can be silenced once they have sounded and be familiar with its use. This is a very important safety device installed for your protection. Be sure that it is kept in A-1 working condition by testing if frequently in accordance with the manufacturer's instructions. The alarms operate on household current, and have battery backups. Its purpose is to provide early warning in case of a fire. Again we stress the importance of keeping your smoke alarms in proper working order. TESTING SMOKE ALARM Test smoke alarms after home has been set-up completely. To test the smoke alarm, press and hold the test button on the cover of the unit, until the alarm sounds. All smoke alarms should sound alarms. If all units do not alarm, replace units immediately. This test should be given to all smoke alarms individually. APPROVED BY >zEV. 1 40,04 9iW i 5 20 NF14 INC. FEDERAL &mUFACTUREO H041E CONSTRUCTION AND SAFETY STANDAHUS SET-UP MANUAL ADDENDUM AD-FS-0001-A 11 TRUSS SHEATHING APPROVED BY IN'A INC. FEDERALMANUFi MREDHOME CONSTRLOWIN ADD SAFETY STANDARDS DEALER (SET-UP)INSTALLED PLYWOOD FOR SHEATHED TRUSSES HINGED TRUSS - NOTE: HOLES TO BE CUT IN SHEATHING TO ALLOW OUTLOOKERS TO PASS THROUGH. , v- TYP. OUTLOOKERS FACTORY INSTALLED PLYWOOD FOR SHEATHED TRUSSES L SIDEWALL 3/8' WIN. APA OR TECO RATED SHEATHING APPLIED TO ROOF TRUSSES LOCATED DIRECTLY ABOVE SIiEARWALLS (APPLICABLE TO ALL SHEARWALLS) PENETRATIONS OF THE SHEATHING ON THE TRUSSES) FOR THE OVERHANG OUTLOOKERS (PURLINS), ATTIC VENTALATION. OPENINGS IN TRUSS SHEATHING MAY BE LOCATED AT ANY LOCATION ALONG THE LENGTH OF THE TRUSS. (18' X 14 1/2' MAXIMUM SINGLE OPENING SIZE IN TRUSS SHEATHING) NOTES: 1. 3/8' MIN. RATED SHEATHING FASTENED TO ROOF TRUSS WITH 7/16' X 1 1/I' X 16 CA. MIN. STAPLES 1 1/4' O.C. AT PANEL EDGES AND 3' O.0 AT ALL FRAMING MEMBERS. (NO GLUE REOUIRED) MARRIAGE WALL 3/8' SHEATHING TO BE INSTALLED ON -SITE K2 VANOZONE III (110 MPH) ALL EXP'I OSURES DAPIA APPROVAL n APPROVED BY MAT E E INC. ON I= f®ERAL MANUFACTURED HOME CONSTRUCTION AND SAFE;Y STANDARDS NOTICE: UKAINK HT: I IA 1l IiEV. LETTER: JACOBSEN HOMES THESE SPECIFlCATIONS AND DRAWINGS ARE R.R. 4-27-98 - ■ ORIGINAL. PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE C P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACRMINC TRUSS SHEATHING - „ SAFETY HARBOR, FLORIDA 34695 R[�H( Si" MATERIALS AVF� AK AW MST VIDED TO BE DRAWING NUMBER: PHONE (813) 726-1138 KEPI CONMEJNIIAL AND SECRET TROM DINERS. AD-HR-0001 12 HINGED ROOF DETAIL HINGED ROOF IN SET-UP POSITION NDS01 1. BRACE RAM ROOF IM N W PA M P'09= W E S14 = N U wo POM Km POSt00l utan au roar �o RtDfE 6 5W p rmn aic roar for RAt. 1101rWM9Qti>tat3-Axr am REF. CALL. PG. C-RF- 223.0 - 223.6 John C. Doeden, Rk. 11<2 Engi m*rmq, Inc APPROVED BY IN00orl Revised =, 06,2006 INC. CM'Fot= JACOBSEN HOMES as �,: ut"M I � �m or. O.A. wow 06-0Z� R.. �slw= Moocomn. rwwwu n M m.00rm ORAWW wu W1 W OF � wNSACRIM HINGED ROOF DETAIL A P.a Box 36B SAFETY HARBOR, FLOWA 34695 MMI RR 9n= RlO��NO W 10 K. oM�iG MAC PHONE (W) 726-1138 OUT OMFMWK No ZW Nm o.oS AD—HR-000Z 13 HINGED ROOF DETAIL UNDERLAYMENT TO BE GLUED 3' MIN. CH BOTH SECW6 OF HNGE ROOF. FOR WIND ZONES 2 AND 3. RAISE EXTENDED SHINGLE AND UNDEFiAYMT AND - AND A MIN. 4 1/2' WIN OF ROOFW CEMENT TO 70P OF LAST SH94ME ROW ON FIXED ROOF SECTION. (THIS IS tO BE DONE BEFORE RAISING HINGED ROOF SECTION.) SHINGLE AND UNDERLAYMENT CEMENTING AT HINGED AREA ATTACH 2 X 6 X 8' BLOCK BEHIND 2 X 6 - OVERHANG FASCIA BOARDS AND SECURE WITH 3-0 X 3' WOOD SCREWS EACH SIDE CF GAP, APPROVED BY Revised ON 14 Nw 30,2006 WooINC. FEDERAL wANOFACTURED MOPE CONSTRUCTION AND SAFETY STANDARDS BLOCK ATTACHMENT AT FRONT AND REAR OVERHANGS WINDZONE III (110 MPH) I , ALL EXPOSURES II NOTES: 1. 8RACE RAISED RDOF SECIM N W RAISED P09TO B CRE SNWQW IWCm Km POSTS NTO POS1110N. John C. DOsd^ P-*• K2 Engine*** NOTICL' MATM19r. oATE: REV. LETIM JACOBSEN HOMES TasE VEOF1C UM AM D NICS AK D.T. 10-02-06 P.Q. Box ma w"W"s a, &%cow MAuk%w Rmr HINGED ROOF DETAIL A m soI TFRIw,S ARE FRanoeD TO me Smr" HARBOR. FL 0A Mlli avert n sma RWM Alp VW R MAIM NMM. PHONE (413) 726-1138 un awmm wp amen am .Has. AD—HR-0003 14 LL ON SITE 151 FELT WITH A 6- MIN. OVERLAP ONTO MAIN CEMENTED WITH ROOF TAR AND SECURED PER NOTE #2 CONTINUE 15# FELT TO ROOF PEAK -- x z 0 SECURE FIRST ROW OF SHINGLE TO 6t IN51ALLtU UN SITE WITH • 6 STAPLES (1' X 3/4' X. 16 GA OR ROOFING NAILS) PER SHINGLE MANUFACTURERS INSTRUCTIONS AND CONTINUE TO PEAK. REMOVE THE ONE PIECE SHINGLE UNDERLAYMENT IN THE GAP (HINGE SECTION -IN DOWN POSITION) BEFORE LIFTING THE HINGED SECTION OF THE ROOF TO ITS FINAL POSITION AND BEFORE INSTALLING THE 151 FELT AND SHINGLES. .DETAIL A 1. CNG OF 15f FELT IS NOT REQUIRED IN ANY AREA EXCEPT WHERE NOTED. 2 F NG OF 15/ FELT IS NOT REQUIRED. (FASTENERS APPLIED JUST TO HOLD FELT IN PLACE UNTIL 3SE LES ARE INSTALLED.) 6 3. D THE. FIRST LAYER OF ON SITE 15/ FELT ONTO THE FIXED ROOF A MR OF 6' AND UNDER THE LAST OF FACTORY INSTALLED SHINGLES IF NEEDED TO MAINTAIN THE 6' MIN. OVERLAP ONTO THE FIXED ROOF, 4. ED IN THE HINGED ROOF ADDENDUM ARE DETAILS: AD-HR-0001 (WITH SPECIFIC END PANEL LAYOUT. AD-HR-0003. AND AD-HR-0004. WINDZONE III (110 MPH) ALL EXPOSURES MPROVED BY �PINC, sf-F .l 2 69ANUFACTURED HOME CIO AND SAFETY STANDARUS -- NonCR DRAWN BY: M.T. DAB' 9-20-03 ttt:v. tl rnaC JAC O B S EN HOMES im rEdR ms AND ORA1t m ARE QI WWL RUMMY. AM MWOOM& DRAWING TITLE: SH➢NGLE AND UNDERLAV"T UA1ERMS OF 04011W MANNACIUM APPLICA110N ON HINGED SECTION P.O. BOX 3" W. slat MAIFRIAIS ARE PRONGED 101E SAFETY HARBOR. FLORIDA 34695 NEWW FOR WWM Pu rWM AO KW K DRAWING NUYBf>i: PHONE (813) 726-1138 an COFMIM Ago smw Rm onam AD—HR-0005 15 PEAK INSTALLATION DETAILS SECURE ROOF PEAK ASSEMBLIES TO - HINGED RAFTER WITH #8 X 4' SCREWS, 6-1/20 O.C. MAX DECKING ON RIDGE BLOCK ASSEMBLIES \ FASTENED WITH (6) 7/16R X 1 1/2" X 16 GA. I STAPLES INTO EACH 16' O.C. RAFTER 'AND 3 1 /2' O.C. MAX, INTO 2 X 4 RAIL (TYPICAL BOTH SIDES) NDS01 NOTES: I. SEE AD-HR-0007 FOR INSTALLATION OF UNDERLAYMENT AND SWNGLES. JACOBSEN HOMES P.O. Box 366 SAFETY HARBOR., FLORIDA 34695 PHONE (727) 726-1138 - a & too .John 0. uoGdwi, F.E. -9Z Enginwring, Eric AY! NDne1w DRAWN WISE SPCC6TCADDRf AND DRAVOM ME OMONAL PROPRUART. AND COWIMITML MAMALS Of .RCCM MAIOXALTURNG NC. S M YATMU All FYMV D 10 WE ICIP01 f0R SF(CFIC 111rrM AMD MAT K IVf COMM AND SECAR FROM OTHM SEE AD- HR-0002 FOR ASSEMBLY DETAILS. ALL VANDZONES ALL EXPOSURES 20 PSF, ROOF 10 PSF D.L RU' C&' CRC - 167.01 - 167.02 OIf m APPROVAL DAPU .r��.... APPROVED BY 0 N 00oRevised J= 09,2006 INC. FEDERAL MAMIFACiUIIED HOME CONSTRUCTION A110 SAFETY fTADDAROf O.A. 1 06-06-06 j W INSTALLATION DETAILS 'A AO-HR-0006 16 SHINGLE/UNDERLAYMENT INSTALLATION SITE INSTALLED SHINGLES (USING THE 000URSE(S) EK S SHINGLES TO 6 FASTENER METHOD) AND CAP INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS. SHINGLE INSTALLATION INSTALL FIRST LAYER OF 151 FELT INSTALL TOP LAYER OF 151 FELT TO ROOF WIN A 6' MIN. WIDTH OF TO ROOF WITH A 6' MIN. WIDTH OF ROOF CEMENT AT EACH END TO ROOF CEMENT AT EACH END TO ROOF DEC( AND/OR EXISTING ROOF DECK AND/OR EXISTING FELT AS SHOWN. „r FELT AS SHOM. SEE OTHER DETAILS FOR 91E INSTALLED ROOF PEAK UNDERLAYMENT INSTALLATION AP ROVED BY AUG 0 1 2a1k INC. mu MANu�►cluAm„ NOTICE DRAIN BY: DATE utv. L" Luc JACOBSEN HOMES TH:S VEWOMM NO WA � ARE M.T.7-18-04 OEOML Wt61t[M. AID OOiMUL DRAIING TIME: „ MATEMKS OF JM MSEM'MA"ACTURK SHIN uAi DERLAYMENT INSTILLATION — P.O. BOX 368 NC &0 HAM" AK PWAM TO K SAFETY HARBOR. ROMA 34695 I[fptN1 FOI 90 RRRO AIO MKT OE ORAMG NUMBER PHONE (727) 725-1138 IVY ONWI t NO, IOU FAIN OMM AD-HR-0007 ADDENDUM TYP. SHIP -LOOSE PLUMBING SUPPORT �- FASTEN TO FLOOR FRAMING MEMBER W/ STAPLE OR NAL BANDING STRAP 'WRAPPED' AROUND PIPE AND FASTENED TO FLOOR FRAMING. 4DE Of NOT LESS THAN 1/4' PER FOOT MUST BE MAINTAINED TOWARD THE OUTLET. WHERE THIS GRADE CAN NOT BE ACHIEVED, NOT LESS THAN 1/8' 'OOT MAY BE USED WHEN A FULL SIZE CLEIWOUT IS INSTN O AT THE UPPER END. 1 MF9A rr rd?Afu PIPM, II NOTE DAM A"R°YAL• 1. PIPE CLEANER AND GLUE SHALL ALSO 8E SUPPLIED BY THE MANUFACTURER FOR PLUMBING CONNECTIONS. ` 2. 48" O.C. MAX. SUPPORT SPACING. ON rl ;ji;� is it JACOBSEN HOMES ➢IE9E safcrleAnars W r°TtDUNDUNBT. " IILEiTFR:; AN7 avAArNfS Aft . R.R. 7-17-97 CAMAS PROUTART. AM Wfmjiw% DRAW 11AE NAMNAIS OF ,NO'S. M MANIOACWOC Q P.O. gee nt SM VAIR,u AW �m w DC PLUMING SUPPORT SAFETY HARBOR, FLORIDA 34693 KCeoa FCR WE= fuVM AND W= BE DHAHNG HW19ER PHONE (813) 726-1138 dri cwmmu" im my flum AD—PL-0001 A� v-sr t;.if 18 NOTES: OPEN PORCH RAILING(S.) IT IS THE RESPONSIBILITY OF THE SET-UP CONTRACTOR OR GENERAL CONTRACTOR ON SITE TO INSURE THAT THE RAILING(S) INSTALLED OR TO BE INSTALLED MEET ALL CODES IN EFFECT AT TIME OF HOME INSTALLATION. PP ROVED BY MAR V II INC. NOTICE: UITA11A1 UT: JACOBSEN HOMESC REV. L�ncn: TNESE sPEaFtcAnoNs AND oRAwNGS ARE M.T.a1.T. 3-30-05 ORIGNAL. PROPRIETARY, AND COWWENTIAL DRABING nn.E: P.O. BOX 368 MATERIALS OF JACOBSEN 11ANUFACTURRNG OPEN PORCH RAILING S Rit SUCH MATERIALS ARE PROWDEO TO 1lIE SAFETY HARBOR, FLORIDA 34695 REMMI FOR SPECK PWOSES AND MST BE DRAWMG NUMBER: PHONE (727) 726-1138 NETT CR7 WIIAL AND SECRET FROM ORERS. AD—PO-0001 19 ON SITE PITCHED ROOF DETAILS IMPORTANT NOTICE THE ON SITE PITCHED ROOF INSTALLATION (INCLUDING SHINGLES AND CAP) MUST BE COMPLETED WITHIN 60 DAYS OF DELIVERY TO THE HOME SITE. FOR ATTACHMENT OF ALL VENTING (INCLUDES 12 EXHAUST & ROOF), SOLAR TUBES AND PLUMBING 41 VENTS SEE AD—PR-7007 & 7009. MAX. ROOF SLOPE FOR ROOF DECKING DETAILS SEE AD—PR-7004. FOR ATTACHMENT OF PITCHED RAFTER TO TRIPLE WIDE SEE ` FOR ROOFING DETAILS SEE AD—PR-7002 „ SEE AD—PR-7008 SHIP THIS SEC. LOOSE � (SITE INSTALLED) )---— — — — — — — — — — — — — -------- � FOR OVERHANGS SEE AD—PR-7003. FACTORY INSTALLED RAFTERS (CENTER SECTION) REMOVE ALL FACTORY INSTALLED FOR ROOF VENTING BOTH FACTORY POLYVINYL BEFORE INSTALLING THE AND ON SITE SEE AD—PR-7005 & 7006 ON SITE PITCHED ROOF RAFTERS CENTER SECTION OF TRIPLE WIDE TYPI AL TRIPLE WIDE HOME REF. PG. IW-07-0011 WITP SITE INSTALLED PITCHED FOR FASTENING C ATER SECTION RAFTERS NOTES: APPROVAL' APPROVED BY ON Revised Oct 25,2007 INC. FEDERAL MANUFACTURED HOME i CONSTRUCTION AND SAFETY STANDARDS NOTICE DRAWN BY: I DATE: REV. LETTER: JACOBSEN HOMES TNESE SKCIFICATNONS AND DRAwexs ARE O.A. 10-24-07 , ORIGINAL. PROPIREUIRY. AND CONFIDENTIAL DRAWING TITLE: _! IB A P.O. BOX 368 �, MAEaN � ON SITE PITCHED ROOF DETAILS SAFETY HARBOR, FLORIDA 34695 REOPIQNT FOR SPM RRPOKS AM DUST BE DRAWING NUMBER: PHONE (727) 726-1136 IVT CONT1O UL AND SECRE7 FROM OTHERS AD—PR-7001 20 ROOF. TO ROOF ATTACHMENT SECURE SITE INSTALLED ROOF DECKING WITH 7/16- X 1 1/2- X 16 GA. STAPLES (12) EACH SIDE OF MARRIAGE LINE TO EACH 16' O.C. RAFTER. SEE DETAIL 'A' SEE NOTE 11 11' MIN. SITE INSTALLED DECKING OVERLAP FACTORY INSTALLED ROOF DECKING _ I � 1L i/ SEE NOTE /2 EBE RIDGE E NOTE BEAMS A I 18' MIN. DECKING Yip CROSS-SECTION REF. PG. RC-07-0044 SITE INSTALLED 7/16- MIN. ROOF DECKING SECURED MATH 7/16- X 1 1/2' X 16 GA, STAPLES. 2' O.C. UAXX, TO EACH 16' QC. RAFTER. SITE INSTALLED RAFTER TO ALIGN MATH FACTORY INSTALLED RAFTER BELOW. FACTORY INSTALLED RAFTER (CENTER SECTION) CA CS C-FS3.88.01 WNOZONV O ALL EXPOSURES (110 MPH) 20 PSF ROOF 10 PSF D.L. 1 SECURE EACH 16' O.C. RAFTER TO RAIL BELOW wTH 2—/10 X 4 1/2' SCREWS AT EACH RAFTER ENO. SITE APPROVED BY INSTALLED PITCHED RAFTER TO ALIGN N17H FACTORY INSTALLED RAFTER. (EA. SCREW TO HAKE 1 1/4' PENETRATION MIN.)=1 ATTACH MATE LINE RAFTER RAILS (OR RIDGE BEAMS) WITH Jun 09,2006. 110 X 4 1/2' SCREWS 9' QC. MAX SPACING, 6 Q.� � C. SEE AD—FA-0020 FOR GAP TREATMENT BETIM SECTIONS. -John C. 80Lfe3f1, P L r 0FRAl ruaaAau I'HM K2 EnghwrkV. Inc. `°""'""CTMAno Sam STA" Mos MpTIC�e oRATO B1. DAIF: i¢v 1E11ER JACOBSEN HOMES MC M O.A. 06-02-06 A wtuawc DRA1l1G nT1� /� ,�x P.O.P.o. B36e We M= w� wM& aF �"urWArt PRMW 10 IK ROOF TO ROOF ATTACHMENT SAFETY SAFETY HARBOR. FLORIDA U695 flow Re 9 =Par® 1"11"67 a[ ORAIRJC NU R PHONE (727) 726-1138 evr mwrxiw Mo air nw pmAD—P'R-7002 21 RAFTER TOP CHORD END ZONE RAFTER/OVERHANG ASSEMBLY ALT. CONSTR. RAFTERS 2 X 6 OUTLOOKER 19' O.C. MAX. BETWEEN OUTLOOKERS . /V �� QO �.._ 2 X 6 OVERHANG FASCIA THIS TRUSS INSTALLED ON SITE BOTTOM CHORD 16r DOUBLED END ZONE RAFTERS TYP. 16' O.C. 19.0 c Mq,E q8.0 2 X 4 NAILING BLOCK (INSTALLED ON SITE) MIN. (3) .1310 X 3' NAILS FROM NAILING BLOCK INTO RIM PLATE OF ADJACENT SEC110N OF UNIT, AND YIN. (3) .131' X 3' NABS FASTENING FASCIA INTO END OF NAILING BLOCK 2 X 6 OUTLOOKER 19' O.C. MAX. BETWEEN OUTLOOKERS ALL OUTLOOKERS SHOWN ARE 2 x 6 SPF /3 FLAT SEE CHART FOR FASTENING OUTLOOKER TO TOP CHORD -MULTIPLE TRUSSES FASTENED TOGETHER W/MIN..1311 X 3' NAILS OR MIN. 7/16- X 2 1/2' X 15 GA. STAPLES 16' O.C. MAMMUM INTO TOP do -BOTTOM CHORDS ONLY. 2 X 6 FASCIA FASTENED TO OUTLOOKER J `— 2 X 6 OVERHANG FASCIA END ZONE ASSEMBLY W/14N. (5) 7/16' X 2 1/2' X 15 GA. NOTE: STAPLES OR MIN. (3) .131' X- 3' NAILS .(SHIPPED ASSEMBLED FOR SITE INSTALLATION) MUMS M BE SECURm M EACH (TYPICAL AT ALL CENTER BRACES) IN X E�1 O INE �� ul M O T, SINGLE MSS ONLY REOT OU75 E OF 3 FT. AREA ....SS MAY IV PLACED ON EIM SIDE NDS01 1. ALL TRUSSES LOCATED WITHIN 36' OF THE END OF THE SECTION TO BE DOUBLED. 2 SEE OTHER DETAILS FOR TYPICAL ROOF FRAMING. 3. EACH TRUSS IN END ZONE AREAS ARE REQUIRED TO BE FASTENED PER AD—PR-7002. TYP. OUILOOKER FASTENING: FASTENERS: Dummy: PEHE7RAl10�k .131 PD NAB. 5 1 1/,f 15 GOL STAPLE B 1 189= 2 r (wcC ; TD') OUILDOKf.R FASIDERS MAY BE lIM= TANOZONE 111 FROM TOP CHORD DM F PEIEM10 ALL EXPOSURE! B MAWAM (110 mm) 20 PSF ROOF 10 PSF, D.L. F. C-RC-197.01-197.02 fGINEER API WAL• DARA APPROVAL• APPROVED BY ONrl Feb 05,2008 z��� INC. John C. itd �L�' FEDERAL WIUfACNRED ROPE cortsrnllcnwl ARn sa�ry srrumaROs K2 Englne0-11119r Inc. JACOBSEN HOMES mx mmlwaARE 0PREW DdMWO M uR0FJWWA P.O. BOX 368 LWO SIG an YAIFNMS ARE PRC► =10 DIE SAFETY HARBOR, FLORIDA 34695 RIww FOR- P11i06E55 AND V=!E PHONE (727) 726-1136 WT tAlimm Alp mw mm DOERS. DRAW BY: DAZE REV. iET1E O.A. 1-29-08. DRAWING mm, 'A END ZONE RAFTER/OVERHANG ASSEMBLY RAWING Nun AD-PR-7003 22 ON SITE PITCHED ROOF DECKING INSTALLATION TYP. ROOF FRAMING 16' ON CENTER TRIPLE WIDE CENTER SECTION PEAK SITE INSTALLED DECKAIG ON PITCHED NO BLOCKING REQUIRED TRUSS SECTION do REMAINDER OF AT CONTINUOUS PANEL B01H WISDE SECTIONS (2 FULL ROWS OF SHEATHNG) SEAMS BETWEEN TRUSSES SEE OTHER DETAILS TO SECURE TRIPLE WIDE MARRIAGE LINE SITE INSTALLED PITCHED TRUSSES WIDTH PER SHEATHING REQUAtEMENT APA RATED ROOF DECKING (OR EQUAL) 1/8' MAXIMUM GAP AND 1/16' MINIMUM GAP BETWEEN DECKING PERPENDICULAR AND PARALLEL TO TRUSSES. ROOF DECKING MATERIAL TO BE 7/16' APA RATED ROOF (24/0 SPAN RATED) DECKING (EQUAL OR BETTER). OTHER TRIPLE WIDE SECTION (NOT SHOWN) WILL BE THE SAME DECKING PATTERN. FASTEN DECKING TO ROOF FRAMING WITH 7/16 X 1 1/2' X 15 GA. STAPLES AT 3' O/C EDGES AND FIELD MANUF. INSTALLED DECKING TO HERE 16h?1 Cyr. 1.:Jt-a R' K2 �.iiC�a et 4i0,19, 11 se. Is v VANOZONE RI ALL EXPOSURES (110 MPH) 20 PSF ROOF 10 PSF O.L APPROVAL• APPROVED BY Revised N 14N. OcctC29,2007 FEDERAL WNUFACrU i HOME CONSTRUMON AND SAFETY STANDARDS JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA J�895 PHONE (727) 726-1138 - 1mNIMCIL m m Dnum ARE awaNK. eRaPRErAar. Alq co�lDotaAL YAIEBIAS Of dAC118�1 YANUFACIIMIlIC Ut 91CH YAMWIS ME RPM m K WT Opp Alp �, 0 DRAW dr. O..k °"'� 10-24-a� REV.` ' A mon DRAW nnE: ON SITE PITCHED ROOF DECKING INST. oRAwRc MIY Aa-I'R-7004 23 SITE INSTALLED PITCHED ROOF VENTING TYP. 50 SO. IN. ROOF VENTS (SEE AD—PR-7006 FOR QUANTITIES) SITE INSTALLED CENTER SECTION OF ROOF TYP. 100 SO. IN. CUTOUTS FOR - VENTILATION OF ROOF SECTION (SEE AD—PR-7006 FOR QUANTITIES) FLAT CENTER SECTION OF ROOF INSTALLED AT MANUFACTURER TYP. ROOF INSULATION --,- / CEILING PANEL CENTER SECTION (FLAT TRUSS) MARRIAGE WALLS MARRIAGE WALLS FLAT CENTER SECTION NOTES: DAPIA APPROVAL OVED BY pIRevised Oct 25,2007 I VC. MANUFACTURED HOME , j CTION AND SAFETY STANDARDS ❑gyp❑ JACOBSEN HOMES ❑„ P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THm SKaMIM AM DRAWINGS MONAL. PROMETAn AM 00NRDENML MATERIALS OF JAC08SEN MANUFACRIRING DIG SUCN IIATT:iZfALS ARE PRDVSDED TO THE RECFENT FOR SPEOFTC PURPOSES AND MOST BE KEPT COIEMTIAI AND SECRET nmu OTHERS DRAWN BY: O A. I DATE. 10-24-07 KLV,'LL' IGK: A DRAWING TlU: SITE INSTALLED PITCHED ROOF VENTS DRAWING NUMBER: AD—PR-7005 24 3 ROOF VENTING / MARRIAGE WALLS TTP. 10/ SR K CUTOUTS FOR vDNTiI or ROOr 5[cum (SEE DIART ►OR R WKWENTS) r_ 100 SO. IN, CUTOUT VENT HOLES REQUIRED IN FLAT ROOF SECTION (16n X SECTION LENGTIt CUTOUT HOLES o To iS'-C I 1S'-6- TO 31'-3' 2 31'-3' To 46 -TNT' 3 46'-TO' TO 6 -6' 62'-6 TD -0 S I I MARRIAGE MALLS FLAT CENTER SECTION OF ROOF FACTORY INSTALLED I I �I MARRIAGE MALLS c l LOW VENT LOW VENT •v •-r I 1=1 050 _ZRG IN. VENTS REDUIRED t 3 HIGH VENT I 1' z --------------r=� I `CENTER LINE OF CENTER SECTION Y Inn i SECT= unia Na im too %m ow K- 10 if-i 2 1 [A S K 67Io [S- 3 2 [A sat I M AodTAAI 10 01 MAK KNIS I •-r ti-r R I •'� —� TIP. SO So. it ROOF VENTS r_,I LOW VENT (SEE CHART FOR REOUIREMENTS) LOW VENT l MARRIAGE MALLS I I SITE INSTALLED CENTER SECTION OF ROOF. J 3 2 W Z . W - o Ali �1 UA'NII PMWAL: AF PROVED BY JUN 14 ?� INC FEDE L MANUFACTURED HOME CON RUCTION AND SAFETY STANDAROS NOTICE: DRAWN BY: OATS REV 'LETTER JACOBSEN HOMES rmSKonCAMG ORAMMARI; R.R. 01-22-04 000MAL PRINAKIARr. NO 00141 11 DRAWING AAE: P.O. Box 368 111p1� OF A%CDM k~Ac�"'"c ROOF VENTING PG SAN MATNTNY115 AK 1AWAM TO IK SAFETY HARBOR FLORIDA 34695 MEOW FOR VM P[WM Asp MISI K DRAY" NWKIL 6-41PHONE (727) 726-I138 PVT (XlIbDIW A� WWI no UbM AD—PR-7006 11r. PITCHED ROOF EXTENDED VENTS SIX INSTALLED VENT CAP OR SOLAR TUBE VENT LAr (OR SOLAR SITE INSTALLED FLEX DUCT (SEE DETAIL 'A') SITE INSTALLED VENT CAP SITE INSTALLED CENTER ,SECTION OF ROOF , EXTEND FLEX DUCT 3' ABOVE RAFTER SHEATHING FLEX DUCT (FACTORY INSTALLED) FACTORY INSTALLED SHEATHING— FYTFNO PIPF Z' AROVF %FATFRNG FACTORY INSTALLED CENTER SECTION OF ROOF TYP. CONNECTION TO VENT FAN, SOLAR TUBE. OR EXTEND TO RANGE HOOD MARRIAGE WALLS PLUMBING VENT (FACTORY INSTALLED) CEILING PANEL rX SITE INSTALLED UMBING VENT PIPE ND 3' ABOVE jR00 (SEE DETAIL �13,) MARRIAGE WALLS FACTORY INSTALLED FLAT CENTER SECTION 'XHAUST DUCT SPLIT ►ND FASTENED TO ROOF )ECKING OR BACKER PITH MIN. 4— 80 NAILS N LIEU OF FASTENING )UCT TO VENT CAP. SITE INSTALLED FLEX DUCT �--SHEET METAL SCREW .EX DUCT (FACTORY INSTALLED) NOTE: EXHAUST DUCT (FLEX DUCT OR RIGID) SECURED WITH 1 SHEET METAL SCREW MINIMUM AND ALUMINUM TAPE TO SEAL AROUND DUCT AFTER SCREW IS IN PLACE. DETAIL 'A' NOTES: 1. FOR VENTS NOT SHOWN INSTALL PER MANUFACTURERS SPECIFICATIONS. Z SEE OTHER DETAILS FOR ROOF FLASHING INSTALLATION. 3_ EXHAUST DUCT MAY BE RUN THROUGH EITHER A SOUARE OR ROUND HOLE CUT IN ROOF DECKING. 4. RANGE AND BATH/AIR DUALITY FLEX DUCTS TO BE SPUCED MTN ALUMINUM TAPE AS SHOWN IN THE DETAIL ABOVE. S. SECURE SITE INSTALLED PLUMBING VENT PIPE INTO COUPLER WITH APPROVED GLUE. PLUMBING VENT ROOF FLASHING (SITE INSTALLED) VENT PIPE (SITE INSTALLED) COUPLER p� (SITE INSTALLED) VENT PIPE 0.#-(FACTORY INSTALLED) DETAIL ' B' DAM MMVM; AP40VED BY JUN 10, ° INC. FEDERAL. ANUFACTURED H061E rnNCTRI I .TIDN AND SAFETY STANDARDS NOTICE DRAWN BY: R.R. DATE Ot-23-04 REV' LETTER: JACOBSEN HOMES w-gE�Eamw-sAmm--,csANIE ORMaw. PROPRETA". NO COWMTIRL DRAWING TITLE _ P.O. Box 368 W- 1pllAl „ARE PROOYYM M II[ PITCHED ROOF EXTENDED VENTS SAFETY HARBOR. FLORIDA 34695 RECIPEMT rat SPECiIC PIRFM NO MIST EE DRAWING NUMBER: PHONE (727) 726-1138 KEPT CafR)EMIK NO SECRET flu olim AD—PR-7007 oo 9R SITE INSTALLED SHINGLE AND UNDERLAYMENT 15+ FELT TO HAVE A 6' MIN. OVERLAP AND A MIN. 6" WIDTH OF ROOF CEMENT THIS ALSO APPLIES TO ENDLAP SEAMS. r FW INSTALLED 151 FELT WIN. INSTALLED OVER THE FACTORY INSTALLED UNDERLAYMENT WITH A 6' MIN. OVERLAP AND A MIN. V VADTH OF ROOF CEMENT. 15/ FELT ALSO CEMENTED PATH A 6- WIDTH AROUND ALL PENETRATIONS OF THE UNDERLAYMENT AND PERIMETER OF ROOF. FIELD INSTALLED ROOF SHEATHING (IYP.) b� I l 6' WIDTH OF ROOF CEMENT WHEN I OPTIONAL 15# FELT IS INSTALLED.. I ' I I WNW LAYER OF 151 FELT i I i I I I J 1 � I ONE-PIECE SI0111iE UNDERLAYMENT ROOF SHEAUNG (TV.) THIS ROW OF SHIMMES TO BE FIELD INSTALLED AFTER THE UNDEALAYMENT HAS BEEN INSTALLED. THE LAST. COURSE OF FACTORY INSTALLED SHINGLES TO LEAVE A MINIMUM OF 6' FROM THE TOP OF THE SHINGLE TO THE EDGE OF THE FACTORY INSTALLED DECIONG FOR UNDERLAYMENT OVER LAP OF 6' MINIMUM. 1/2' TO m m1om = +■MIME = FASTENING DETAIL 1. CEMENTING OF OPTIONAL 150 FELT IS NOT REQUIRED IN ANY AREA EXCEPT WHERE NOTED. 2. FASTENING OF OPTIONAL 15/ FELT IS NOT REQUIRED. (FASTENERS APPLIED �hhnl. 4j:. �^ARE JUST TO HOLD FELT IN PLACE UNTIL SHINGLES ARE INSTALLED.).1uaf1, 3. SHINGLES INSTAlLEO PER MANUFACTURERS INSTALLATION INSTRUCTIONS n F_ng:rcz;f,, g' mc` ONLY WHEN SPECIRC APPLICATIONS ARE NOT COVERED. N0710E JACOBSEN HOMES rim summs = wim ARE p =&. PRn WARx MM CmfwwK Em P.O. BOX 368 NC. � Y 19 U ME PRMW TE SAFETY HARBOR. FLORIDA M95 REOW:OR Spon PJWM SO W9 NE PHONE (813) 726-1138 KIM Odi10fl1RK AND ww Ro olm WINDZONE ILA (110 MPH) .ALL EXPOSURES FMVAL DYED BY Revised Oct 29,2007 INC. KAAUFAC UREDHOME. CTIOH AND SAFETY STANDARDS O.A. 10=24-07 owAWILE. SITE WTAIIID SHI U AND UNDFRLAYIENT � Numom AD-PR-7008 TYPICAL FLASHING INSTALLATION ROOFING TAR UNDER NAILING FLANGE AT ALL FASTENERS TYPICAL SHINGLE ROOF i I ROOFING TAR APPLIED OVER TYPICAL FIELD INSTALLED RAFTER FASTENERS AND UNDER ALL SHINGLES OVERLAPPING THE ROOF FLASHING. .105" X 1" MINIMUM ROOFING NAILS OR .113* X 1' MINIMUM NAILS MAY OPTIONAL SHINGLES MAY BE APPLIED TO BE USED IN LIEU AS OF STAPLES FOR FASTENING FLASHING TO ROOF. COVER ANY ROOF VENT FLANGE BY SECURING THE SHINGLE TO THE FLANGE AREA NTH ROOF- ING MASTIC (TAR). OPT. SOLAR TUBE INSTALLATION TYPICAL SHINGLE ROOF SOLAR TUBE DOME. WITH NAILER FLANGE. SECURED TO ROOF. ON TOP OF UNDERLAYMENT. AND 70P OF FLANGE UNDER SHINGLES. WTH 80770M OF FLANGE OVER SHINGLES (BOTTOM FLANGE MAY BE COVER WITH SHINGLE TABS SECURED W7H AN APPROVED CAULK). - TUBE SUPPLIED BY SOLAR TUBE MAN. DAP111 APPROVAL NOTES. APPROVED BV T NGE FASTENED To SHINGLE T Afi STAPLES O.C. (SHINGLES APPLIED UNODERVLowER END OF FLANGE). JIiIK A 0 INC. FEDEVALMANUFACTIL)REDIJOWIE CON ETYSTADARDS NOTICE DRAWN BY: M.T. DATE 02-04-04 REV. LETTER: JACOBSEN HOMES msE sKamr� Ara m-mm DRAWNG TITLE. TV. FLASHING INSTALLATION' y 'M pU~AC1L"X CWMTM „ P.O. BOX 368 SAFETYPHONE 3) rIG SUCH W11CRURS ARE PROVOED 10 11[ Komi NO CREI "M O,� oRAWrlc NuueER AD—PR-7009 (HARBOR. 726-1138,695 9R ADDENDUM GENERAL NOTES / TIE -DOWNS NOTES: 1. FRAME TIE -DOWNS SHALL BE INSTALLED TO PROPERLY SECURE THE HOME. 2. VERTICAL TIE -DOWNS ARE REQUIRED IN ADDITION TO THE FRAME TIE -DOWNS 3 VERTICAL TIES MAY BE SECURED TO THE SAME GROUND ANCHOR AS THE FRAME TIE-CCYINS WHEN A DOUBLE HEADED ANCHOR IS USED AND IS CAPABLE OF RESISTING THE COMBINED LOADING. l E4 ANCHORS ARE NOT INSTALLED AT THE ANGLE(S) SPECIFIED IN THE TABLE(S), A STABILIZER PLATE MUST BE ,NSTAL:-m IN ACCORDANCE WITH THE ANCHOR MANUFACTURER'S INSTRUCTIONS. 4. FRAME RE -DOWNS AND ANCHORS ARE NOT SUPPLIED BY JACOBSEN HOMES (TO BE SI.PPL'ED BY OTHERS). S VERTICAL TIE STRAPS MAY BE SUPPLED BY JACOBSEN HOMES OR ANCHOR BRACKET MAY BE INSTALLED BY JACOBSEN HOMES FOR ATTACHMENT OF VERTICAL TIE STRAPS, IN EITHER CASE ALL ANCHORS AND END TREATMENTS ARE TO BE SUPPLIED BY OTHERS. 6. ALL GROUND ANCHORS AND FRAME TIES SHALL BE INSTALLED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. GROUND ANCHORS AND FRAME TIES ARE NOT TO EXTEND BEYOND THE EXTERIOR WALL OF THE INT. 7. STEEL ANCHORING EQUIPMENT EXPOSED TO THE WEATHER SHAM BE PROTECTED WITH A MIN. OF 0.30 OZ. OF ZINC COATING PER SQUARE FOOT OF STEEL 8. DESIGN BASED ON 95 1/2' I -BEAM SPACING AND A MAXIMUM SIDEWALL HEIGHT OF 8'-0' (82' I -BEAM SPACING IS ACCEPTABLE FOR 10' WIDE SECTIONS OF MULTI -WIDE UNITS W/ 90' SIDEWALL HEIGHT ONLY). 9. LONGITUDINAL TIES SHALL BE INSTALLED ON THE INSIDE OF EACH I -BEAM AT THE CROSS-VOABER LOCATIONS OR PER ALTERNATE DETAILS IN ACCORDANCE PATH THE SPACING TABLES AND NOTES 4, 6, 7 AND 16. 10. FRAME TIE -DOWNS SHALL BE 'WRAPPED' AROUND THE MAIN I -BEAM (AS SHOWN ON TIP. CROSS-SECTION DETAILS) AND SHALL COME OFF THE TOP FLANGE OF THE I -BEAM WITH AN APPROVED BUCKLE OR LOOP. 11. ANCHORS SHOULD BE CERTIFIED FOR THESE CONDITIONS BY A PROFESSIONAL ENGINEER ARCHITECT OR A NATIONALLY RECOGNIZED TESTING LABORATORY AS TO THOR RESISTANCE BASED ON THE INSTALLED ANGLE OF THE DIAGONAL TIE AND/OR VERTICAL LOADING AND ANGLE OF ANCHOR INSTALLATION AND TYPE OF SOIL IN WHICH 1HE ANCHOR IS TO BE INSTALLED. 12. GROUND ANCHORS SHOULD BE EMBEDDED BELOW THE FROST LINE AND BE AT LEAST 12' ABOVE THE WATER TABLE. 13. GROUND ANCHORS SHOULD BE INSTALLED TO THEIR FULL DEPTH, AND STABILIZER PLATES SHOULD BE INSTALLED TO PROVIDE ADDED RESISTANCE TO OVERTURNING OR SIDING FORCES 14. "ANCHORING EQUIPMENT SHOULD BE BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT TO RESIST THESE SPECIFIED FORCES IN ACCORDANCE WITH TESTING PROCEDLIHES IN ASTM STANDARD SPECIFICATION D3593-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL AND SEALS 15. ALL GROUND ANCHORS TO BE RATED FOR LOAD LISTED IN TABLES, TIMES 1.5 SAFETY FACTOR OR AN ULTIMATE LOAD OF 47251 (31501 DESIGN LOAD), WHICHEVER IS GREATER. VALUES IN THE TABLES ARE DESIGN LOAD VALUES. 16. A MAXIMUM OF TWO LONGITUDINAL TIE -DOWN STRAPS MAY BE INSTALLED AT A SINGLE CROSS -MEMBER LOCATION. IF MORE THAN TWO LONGITUDINAL TIE -DOWNS ARE REQUIRED (SEE APPROPRIATE SPACING TABLES)ADDITIONAL CROSS - MEMBERS MUST BE USED FOR ATTACHMENT OF STRAP(S) (OR SEE OTHER DETAILS FOR ALTERNATE STRAP ATTACHMENT). 17. LONGITUDINAL TIE -DOWN STRAP(S) MAY BE INSTALLED AT AN ANGLE NOT PERPENDICULAR TO THE CROSS -MEMBER TO WHICH IT IS ATTACHED (SEE NOTE 16) IF REQUIRED TO MISS PIER LOCATIONS OR OTHER OBSTRUCTION(S). 18. ALL FIGURES (DETAILS) SHOWN IN THIS SECTION ARE TYPICALS ONLY. REFER TO THE APPROPRIATE TABLES FOR THE REQUIRED NUMBER, SPACING AND/OR SPECS OF SPECIFIC TIE -DOWNS AND ANCHORS REQUIRED. 19. SEE OTHER DETAILS IN THE SET-UP MANUAL AND ADDENDUM FOR BLOCKING P,EQII;REMENTS. ALL BLOCK:YG DETAILS CONTAINED WITHIN THIS MANUAL ARE APPLICABLE FOR ALL ZONES AND ALL EXPOSURES THESE NOTES AND DETAILS ARE APPLICABLE FOR WIND ZONE 1I AND/OR WIND ZONE III. THEY ARE ALSO APPLICABLE TO BOTH EXPOSURE 'C' AND EXPOSURE V. SEE APPROPRIATE TABLES FOR .SPECIFIC INFORMATION ON EACH. ENpNEER``kQQSl1t "D'N/41/'' 0 4-P- Q•'' \STE .��a ); qZ No.RFo'..'L ENE8703571.': JACOBSEN HOMES NOTICE /h/p THESE SPEOnCAnMS AND DRATYN Is ARE „ fill OIEONAE, PROPWETARY. AND CON Mr&AL fDRA P.O. BOX 368 MATERIALS OF .IACODSEN MANTFACIEATINC SAFETY HARBOR. FLORIOA 34695 aK SiCH MATERIALS ARE PRONGED TO THE DI REWT FOR SPEOAC P.RP= NO WSi BE PHONE (813) 726-1138 IOPT COIdMRq AND SECRET EROY OTHERS ftj ED BY jLN J.510 � 44, f1 INC � Anv�WaME AWosaETTSTuouq C.L.Y. DATE: 5-19-95 REV. LETTER e TD—GENERAL NOTES A 9:R AD—TD-0001 ` 29 ADDENDUM NORMAL TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE (�1 MIN. W140 ZONE II WIND ZONE I,II! DIN. Ott. ENO OF ANCHOR AN MIN.OTY. E END OF MiCHOR A1iCaF �J FLOOR �4 WIDTH �t A SECTIONEA. EA. YIN.. 6 EA SECTION 111N. B 20'-0' 2 36' 2 45' 24'-0' 2 46' 2 60' 2 50' 3 38' 2 54' 3 41' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE n WIND ZONE III sAaNc DEL. HEAD ANCHOR ANGLE SPACING DEIL HEAD ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG LOAD LOAD 20'-0' 12' 8'-0' 31501 40'-50' 6'-8' 3150# 40'-50' 24'-O' -12' 8'-0' 31501 40'-50' 6'-8' 3150# 40'-50' 25'4 12' 8'-0, 3150 j 40'-50' 6'-8' 31501 40'-50' 26'-8' 12' 5-0' 1 31501 40'-50' 6'-8' 31501 40'-50' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III FLOOR MIN. OTY. EA. END OF ANCHOR MIT OTY. EA. END OFANGLE ANCHOR WIDTH Eti SECTION ink IN. a Ex SECTION MIN. e 20'-0' 2 50' 2 68' 24'-0' 2 70' 3 50' 25'-4' 3 1 45' 3 60' 26'-8' 3 45' 3 60' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE N1 SPAaNG DEL. HUD ANCHOR ANGLE SPACING DBL HEAD ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG LOAD LOAD 20'-0* IF 5-4 31501 40'-45' 4'-0' 31508 40'-50' 24'-0' 12' S'-4' 31501 40'-50' 4'-0' 3150# 40'-50' 25'-4' 12" 54 1 31501 40'-50' 4'-0' 31501 40'-50' 26'-8' 12' 5-4' 31501 40'-50' %%%1 1111111, '-0' 31501 NOTES:ENGINEER` O�'C�^/a, DANA APPROVAL 1. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS. '�t�``�� Q4rG� N 0 RFo.�/�j i PPROVED BYE 2. SEE AD-TD-0011 FOR MAXIMUM PIER HEIGHTS REQUIRED FOR THE LOADS TABULATED ABOL£. :• EiVE8 5 OF: Q-= INC. OIA� N� .� ',, �lJ,'•.,•.... � �. ►��,� tra,e,crc.rasA,ETlswtAlloe JACOBSEN HOMES ■ NOTICE: THESE SKOnCATIONS AND DRA"NGS ARE ClaGINAL, PROPRIETARY. AND COWDENTIAL iORAtM�b •• C.L.Y. DATE: 5-30-95 REV. LETTER: DRAMANG TITLE: MATALS OF JAC06SEN MNAA'ACTURING TRI NORM. SPACING TABLES P.Q. BOX 368 „ SAFETY HARBOR. FLORIDA 34695 NC SLCH WATEM&S ARE PROMDED 10 THE REOPUR FCR sErnc wuom AND IGAT DE AND SEA rRW 07HEM DRAWING NUMBER: AD-TD-0010 PHONE (813) 726-1138 IVT CWMnk 30 ADDENDUM slot 11 ALTERNATE TIE —DOWN SPACING TABLES � �1 ZONE II & III/EXP. C �4 LONGITUDINAL TIE —DOWN SPACING TABLE y� IND ZONE u IND ZONE N FLOOR �TM NR W. u ff ANm AwaE 0L My. aF AM MaE sm u �>� a e u w socaoM mK B 2 54' 3 40' 24'-0' 2 54' 3 40' 254 2 60' 3 4T 26'-6' 3. ff 3 48' 3 4T 4 41' (SEE NOTE 14 FOR ANCHOR ANGLES) VERTICAL TIE—DOIN / FRAME TIE—DOTIN SPACING TABLE YIN. wix IND ZONE 11 WIND ZONE 11 s°w�s I lL IEw LaVD AIMMILE �" OBI. WA UMD Nitl10k WE FLOOR IMW EAVE OVERHANG 1'2S 4' 12' 6-4' 31501 40-45' S-4' 31501 35-40' 1 244 12' S4 3154 40'-45' S-4' 3150j 35-40' 254 12' 51-4' 315V 40'-45' 64 31501. 35-40' 12' T 4' 3150f 40-45 5'4 3154 30'-8' 12' 54 31501 40=45' 5-4' 31501 35'-40' (SEE NOTE 14 FOR ANCHOR MGLES) 4e,%J1111111/psj,,, C. DpF `eo �• No 45484 ,^ m all -� a + O ; G o O •. . ® REF. CALC. '�A�F'�.� Q'• F� 1 O ��oe C-TD - 215.01 - 215.20. <� • •..... • E? ee .s NA' ,E��eo• S• ENptm APPROVAL• DAPIA APPROVAL' 1. SEE 0-M- 1 FOR ADMMAL REN E101M APPROVED BY 00 4. SEE AD-M-0011.1 FOR YAM W M MMIS ffAM ED FOR 1HE LOADS 16,2009 TABIAATED tamJun DEWI ON 1M PAM AMICABLE TO DO M LADES ONLY. I N C 3' TE-000 . 4. NO MOM ANGLE S11 W BI 11E CHART ABOVE CANNOT BE ACHEYFD, FEDERAL �pIFACfURFD NOrE ODNSIRDCIIDA AID SAFFn SfANDARDs 96TALM AN APPRDO STAKW PLATE JACOBSEN HOMES N�1iC ► DUN Ft M.T. DAZE: 06-04-09 REk LETTER:' 'kTERNATE SPACING TABLES MMU Of d/COW MWAC UM P.O. Box us" SAFETY HAR"" FLORIDA 34M PHONE (613) 726-1130 IE�ammss RSUM # � WM W 1 AK MW N K m" cmmmA� n mT m am MAIM NLR A�-T�3-001 �,1 31 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS YAA. rLn Nr-llr•wlu IFAXE rcn rar lu-WIV �.wr. r.n rar.rw.v ..-_• .... ... .� ...�— .-_ -_ - FIGURE 1.0 SEE FIGURE 2.0 FOR ALTERNATE TIE -DORM EMOD TYPICAL CROSS SECTION SHOWING TIEDOWNS SEE NOT: 5 FOR 11030 HEIGHT FIGURE 1.1 SEE FIGURE 5.0 FOR ALTE50IATS TIE-DO11N 'EL ENGINEER NOTES: ARPROVAC eoCp''�%�4 AL, 1. SEE AD-TD-0010 FOR SPAONG TABLES �G \S EgFo..rL i .: 2 SEE AD-TD-0010 FOR WANTHY OF LONGTUDIAL TIE -DOWN STRAPS REQUIRED. Q No. - I 2 3. SEE OM DETALS FOR BLOH]OHG (PIER) QUMEnTY AND OTHER REQUMAENTS. - - ENE8703571 INC 4. SEE AH3-TD-0001 FOR ADDITIONAL REQUEREYENTS _ I v PA yNy1iC11/®NOE 5. ZONE 2/E0POSURE V. 60' MA)MIUM HEIGHT ' '� cJ dT� i ��W � Nov= ZONE 2/EP05URE V; 44' MA)MM HE7GHT :�0••' "7�9 P' •� .� REF. CALCS ZONE 3/bP0511RE �C: 40' MAMM HEIGHT �, �` OII'�,.•'•�� ZONE 3/EXPOSURE V: 36' MAXiV HEIGHT �ii,��Ftis+/O • • �,� `���`� NOMM Oe "� C.L.Y. DATE. 3-27-95 REV LETTER. J AC O B S E N HOMES mx SPECnCA7=S AND DRAWTHM ARE ... OTOONAL. PROPRIETARY. AND COIM10 NM DRAWING nnE: MATERIALS OF JACOBSENN MANWACROW FIGURES 1.0 AND 1.1 P.O. BOX 368 NG SUOI MATERALS ARE PRf,YOO TO THE SAFETY HARBOR. FLORIDA 34695 RFCPENT Fat VEDF PUiPM AND MUST BE DRAWING NUMBER PHONE (813) 726-1138 WT COIFWlK AM =W IRa VWM AD-TD70011 32 ADDENDUM RECOMMENDED TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SNOWING TIE —DOWN SPACINGS FIGURE 1.0 TYPICAL CROSS SECTION SHOWING ' VEDOWNS aAOR TV. ANm ANGIE jsEE NOTE P) amm mu (SEE NOTE P) FIGURE 1.1 MMM Basin ON 951/f X-BEAM cENTERs AND 96. KGH MRALLS) NOTES: 1. SEE AD-TD-0010.1 FOR SPACING TABLES 2. SEE AD-7D-Om0.1 FOR QUAMIY OF LONGIIUDIAL TIE-DOV91 STRAPS REQVARED. 3 SEE OTHER DUAILS FOR BLOC W (PER) QUANTITY AND OTHER REQUIREMENTS 4. SEE AD-TD-Dom FOR ADDRIONAL REQUIREMENTS. 5. ZONE 2/EXONXSM 'd, 67' MAXIMUM HEIGHT ZONE 3/1 VOWRE 'C': 56' MAMMUM HEN;NT 6. WHEN ANCHOR ANGLE SHOWN ON AD-ID-0010.1 CANNOT BE ACHIEVED, INSTALL AN APPROVED STAEILUER PLATE e�pesssaeeeeese tie®°�� C • �d� ��oo, 0 o'a, m°®11e114I NAe ®s�aeee as SE NOTE 5 RXR YA1015UY IEIBIT APPROVED BY ON' Jtm 16,2009 INC. FEDERAL MANDFACNRED HOME CONSTROCf10N AND SAFiW STANDARDS F. CALM GTD- 215.01 - 215.20 NOTICXt MAWR nT: "n'� �•• JACOBSEN HOMES TIC uwm Aw m M.T.os—o�—os MA AIS AWFAO>u> G DRA1xNc ' MURES 1.0 AND 1.1 P.O. BOX 368 W. SIOII MATLIOAIS AK PRMM.7011E SAFETY HARBOR, FLORIDA 34695 ROX W Fat SM R1P= NO WST E DRAWING NUMBER PHONE (813) 726-1138 JVT CG16IDW L Alm Rif FROM OpI K AD—TD-0011.1 33 ADDENDUM NORMAL TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE t MIN. FLOOR WIDTH WIND ZONE II WIND ZONE III Yw• OTr• EA. END OF EA SECTION ANCHOR ANGLEEA YIN. 9 YIN D END OF EA SECTION ANCHOR ANGLE YIN. 9 12'-0' 2 43' 2 I 55' 2 50' 2 68' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DEL HEAD LOAD ANCHOR ANGLE SPACING DBL HEAD LOAD ANCHOR ANGLE 1. FLOOR WIDTH EAVE OVERHANG 6' 8'-0' 31501 40'-50' 6'-8' 3150# 40'-50' 13'-4' 6' 8'-O' 31501 40'-50' 6'-8' 31501 40'-50' LONGITUDINAL TIE -DOWN SPACING TABLE O MIN. WIND ZONE II WIND ZONE III . FLOOR WIDTH MIN. OTY. EA. END OF EA SECTION ANCHOR ANGLE YIN. A UK OTT. EA. END OfANGLE EA. SECTION ANCHOR YIN.. 9 12'-0' 2 64' 3 41' 12'-0' 3 37' 1 4 33' �t'(Q 13'-4' 3 42' 3 55' 13'-4' 4 30' 4 38' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WND ZONE III SPACING DEL HEAD LOAD ANCHOR ANLLE SPACING DEL HEAD LOAD AN010R ANGLE FLOOR WIDTH EAVE OVERHANG 12'-0' 6' 5'4 3150# 40'-45' 4'-0' 3150- 40'-50' 13'-4' 6 5'-4' 31501 40'-50' 4'-0' 3150# 40'-50' NOTE 1. SEE AD—TD-DDO1 FOR ADDITIONAL REOLIMENTS 2. SEE AD—TD-0013 FOR MAXIMUM PIER HEIGHTS REQUIRED FOR THE LOADS TABULATED ABOVE. 3. MAX. EAVE OVERHANG REFERS TO OVERHANG AT SIDETWALL NOT FRONT OR REAR. 4. ABOVE TABLES APPLY TO I60' FLOOR OR 144' FLOOR WIDTHS VATH 95 1/2' 1—BEAM SPACING 96' MAXIMUM SIDEWALL HEIGHT AND 6' MAMLIM SIDE OVERHANG (6' OVERHANG MAX. EACH SIDE OF UNIT).4t`� ENGINEER, f'7 ,!//��i �GV$TE9�. F,L. � N0. O %JLN ENES703571 = * ' �-_SITA%TI�'= AF � : 1 ��'• (.l� �� � ��. '• �t , '!�Oia� DAPIA APPROVAL' APPROVED BY 1 5 f N C FLOM WMlfAETM"M C93fil�IR71 AlO SAFETY SiMGMLA JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-113B NOTICE: A//Fq 11 rasf sKa'1CATWNS AND DRAWNW ORDINAL PROPRIETAAY. AND CMnDOIR& MATERIALS OF JACOBSEN MANUFACIMNG pK 9WARMS ARE PROWED TO THE fUR REOINT FUR SPLUX PiPRM AND WST 81 IQPT cwl w,,x No SECRET FROM mum 1111`1"� C.L.Y. OATS: 5-30-95 REV. LETTER: / \ DRAWING TITLE: NORM. SPACING TABLES DRAWING NUMBER: AD-TD-0012 34 TYPICAL SIDE ELEVATION SHOWING TIE —DOWN SPACINGS TYPICAL CROSS SECTION SHOWING TIEDOWNS ADDENDUM TIE -DOWN SYSTEM FIGURE 1.2 SO FI M 2.0 FOR 1LTH IR M-DOW WMD FIGURE 1.3 SFB MUU 7.0 FOR ALMATS M-WVX ROD SEE NOTE 5 FM 101M HW 1. AD-m-0012 FOR SPAONG TABLES Na N07ES 2 AD-m-0012 FOR Ix1A1m of LONaIUDIAL ME ���\�' '.. • DoF `` �srE ' �F'-.,, ` '�G qF APPROVED BYP, -Do S7RAPS REGUIIED. -. 2 s 3. 070 MTAIS FOR BLOQONG (PIER) OUAN7I7Y AND 07HER REOUFROBA IMM Q` N0. O Z 4. AD-m-ooDl FOR ADDInoNAL REOuripuEN7S EN 870357il �� -5. ZONE 2/DMRE V. 30' YA)MM WMT V: ZQNE 2/bMRE 48' YA=UY RMT ZO�E 3/DPOSURE V- 28' 4A1OW111 HEIGHTWtft V.- A ` o f •' • ��� ml*CnM � s ZONE 3/DZO AE 60' NAXWJM HEIGHT ; / . .� .. •� u JACOBSEN HOMES 7HESESPECilp►naaAmIRA' AN �°Rw`� C.L.Y. 5-19-95 P.O. sox 3W CMQNAL. PR0P1 UMY, AID ooNFlDom MA7s OF �M I,NVAc1U M �►cl> DRAYANG n1LE: FIGURES 1.2 AND 1.3 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 D_ SUCH MAIM S W PMWD 70 18E Nimm FOR sum gpp0g5 NID 9M II lur cmrm m#t me mm FROM amm H pRAYANG MIYBER AD-TD-0013- - 4C ADDENDUM ALTERNATE TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS FIGURE 2.0 SEE FIGURES 1.1 AND 1.3 FOR TYP. CROSS-SECTION(S) ..,,L111TI111.._ �WQr\S E,q �:occ ��'% DAPIA APPROVAL 1. SEE AD-TD-0010 FOR SPACING TABLES �: Q�' No. FO '? APPROVED BY 2. SEE AD-TD-0010 FOR OUANITF OF LONOITUDIAL TIE-DOIIN STRAPS REOUIRED. ENE8703571 - 5 3. SEE OTHER DETAILS FOR BLOOONG (PIER) QUANTITY AND OTHER REOUIREIIENTS. 4. SEE AD-TD-0001 FOR ADD17IONAL REQUIREMENTS. NIPFINC • ��'FSS1Q A� E� 'A��rrrrrrr" A� ����. %%% JACOBSEN HOMES NO717CE: THESE sPEancwnONS AND DRAVANGS ARE DRAWN BY: C.L.Y. OAIE: 5-19795 REV. LETTER: P.O. BOX 368 ORIGNAL PROMEURY. AND OONF1DOr11AL MATERIALS OF JACRTgN YNATFACIURINC YCR TT A� 1MDSTHE DRAWING TITLE. FIGURE 2.0 SAFETY HARBOR. FLORIDA 34695 REOar Ms A DRAWING NUMBER PHONE (813) 726-1138 PVT OOrQDE nk me moo FROM OTHERS AD-TD-0014 ADDENDUM ALTERNATE TIE -DON SYSTEM(S) ALTERNATE LONGITUDINAL TIE-DOiNj INSTALLATION METHODS SIDE VIEW OF PAIN FR".- 1 --DOWN STRAP -- SIC OTHER2AP FOR nE-DM \ - SPECIFICATIONS, APPROVED ANCHOR WELDED TO WAIN I -BEAN (SEE OTHER DETAILS SEE W-TD-0200 FOR FOR MELDING) TO BE INSTALLEi RADIUS CLIP DETAILS AT E FACTORY. REWIRED INS LOCATION). (MW. 31501 %PRANG (DESI;N] LOAD AND 47251 ULTIMATE LOAD.) D ANCFKL THER DETAI S FOR SIZE, A. OTHER INSTALLATION N01ES SC ID HEADER (CROSWEMBER) SIDE M I. SEE AD-TD-0010 FOR SPACING TABLES 2. SEE AD-TD-0010 FOR OUANITY Or LONGITUDIAL TIE -DOWN STRAPS BEOUfiED. I SEE OTHER DETAILS FOR BLOCKING (PIER) OUANTITY AND OMER REQGREMENTS. 4. SEE AD-1D-0001 FOR ADDRANAL REOIAREMENTS. FIG URE 2.1 X 3/4' HEADER 1 CUT INTO HEA• MUST BE LOCATED FOR STRAP ATTACHMENL MITNN S' OF MAIN (FACTORY CUT) CHASSS I-BEALL SEE AD-M-C203 FOR RADIUS CLIP DETAILS (REQUIRED THIS LOCA1,1011). GROUND ANCHOR' SEE 01HER DUALS FOR SIZE, ANGLE 'ANO OVER IISTALLA110N NG rS, �htrR APPROVAL i .0.. -i�NAlts ;;;,� malOR BRACKET AND TIE -corn DEVICES ARE CERTIFIED BY 0110S FIGURE 2.2 '.A APROYAL• =M TWARM OI. un�c. ncr. L:ntN; JACOBSEN HOMES THESE SKWICA?ONS AND CRA,ThGS AU . C.L.Y.. 6-13-95 OAIGNAL FRG°XIART. AQ CO"O1TIIL CRAINING TITUL, FIGURES .1 do 22 .� �; P.O. 80X 368 VATOWS OT JACWSEN WN"ACTMIG SAFETY HARBCRi, FLORIDA 34695 W- SUOI MAWKS A"E PRO"D TO THE F PHONE (813) 726-1138 cl�jq#ammnyo� DRAWN. NWB[R AD-TD-0015 LONGITUDINAL STRAP ATTACHMENT TrPICA TYPICAL LONGITUDINAL ANCHOR STRAP (FIELD INSTALLED) NOTES: ' 1. SEE OTHER DETAILS FOR STRAP PROTECTION AT ALL SHARP CORNERS 2. ALL -STRAPS TO BE TYPE 1, FINISH B, GRADE I STEEL STRAPPING, 1 1/4" WIDE AND 0.035 INCHES IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D 3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL. AND SEALS. AM CLAMP, AMANUFACURED BY I ENGINEERING, PART 159011 CTURER'S INSTRUCTIONS FOR COMPLETE INSTALLATION DETAILS) DAPIA APPROVAL A PROVED EY 15 20 INC. FEDE AL MANUFACTURED HOME DON RLICTION AND SAFETY STANDARDS . . NOTICE DRAWN BY: M.T DATE: 6-12-01 REV. LEMM: t -JACOBSEN HOMES THESE SPEOFlGTIONS AND ORAYMUS ARE 'ORIGINAL. PROPRIETARY, AND CMDENTIAL DRAWING TITLE: _ MATERIALS of JACOBSEN MANUFACTURING LONGITUDINAL STRAP ATTACHMENT P.O. Box 363" LNG SUCH MAMMALS ARE FRONDED 10 THE SAFETY HARBOR. FLORIDA 34695 RECPIflIT Fat 9W PURPoSES AND MUST BE DRAWING NUMBER: PHONE (727) 726-1136 KEPT 0M4 AND SEW TRDIJ OTHERS AD-TD-0016. WNFi 38 ADDENDUM Q�0 OFFSET UNIT TIE -DOWN SPACING TABLES S�� ZONE `II & III/EXP. C& D C6� 1 1 / (�1 v w 0� LONGITUDINAL TIE -DOWN SPACING TABLE MIN. FLOOR WIDTH WIND ZONE II WIND ZONE III UIN. OTt EA. END OF EA SECTION ANCHOR ANGLE UK a UK oTY. FA END OF EA. SECD011 M CROR AMU UK 0 10'-0' 2 44' 2 56' 12'-0' 2 57' 3 42' 13'-4' . 3 38' 3 50' VERTICAL TIE —DOWN •/ FRAME TIE —DOWN SPACING TABLE MIN. FLOOR (MOTH MAX EAVE OVERHANG WIND ZONE II WIND ZONE III SPACING MEAD LOAD LOAD ANCHOR ANGLE SPACNG DB. HEAD LOAD ANCHOR ANGLE 10'—o" 12' 4'-0' 31501 40'-50' 4'-0' 31501 40'-50' 12'-0" 12" 4'-0' 30001 40'-50' 4'-0' 31501 40'-50' 13'-4' 12' 5'-3' 31501 40'-50' 4'-0' 30001 40'-50' 111 o LONGITUDINAL TIE —DOWN SPACING TABLE MIN. FLOOR WIDTH WIND ZONE II WIND ZONE III VIM. OTT. EA. END OF FA sECTNaN ANCHCR NON.K a UK oTY. EA. END OF EA. SECTION ANCHOR ANGLE � UK e 10'-0' 2 64' 3 46' 12'-0' 3 50' 3 68' IS-4- 3 58' 4 48' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING -TABLE MIN. FLOOR WIDTH MAX. EAVE OVERHANG WIND ZONE II WIND ZONE III SPAONC DHL HE/:1 LOAD ANCHOR ANGLE SPACING DBL� ANCHOR ANGLE 10'-0" 12' 4'-0' 31501 40'-50' 2'-8' 31501 40'-50' 12'-0" 12' 4'-0' 31001 40'-50' 2'-8" 31501 40'-50' 13'-4" 12" 4'-0' 30651 40'-50' 2'-8' 30001 40'-50' NOTES: ENGINI�tM� EV�QF� A ir�D BY 1. OFFSET SECTION WITH THE MARRIAGE LINE WALL EXTENDING BEYOND THE ENDINALL OF THE REVISED ADJACENT SECTION MUST BE TIED DOWN AT THE MARRIAGE LINE IN ACCORDANCE .• / WITH THE TABLES ABOVE THE SIDEWALL SIDE AND THE ADJACENT SECTION(S) ARE T TIED •� SEP 0 9 1 ABE DOWN INACCORDANCE WITH THE NORMAL SPACWG TABLES (AD-M-0010). . � � s. 2. SEE AD-M-0601 FOR RDOITIONAL REQUIREMENTS. -CT ' �. INC. 3. SEE AD-M-0021 FOR MA)OMUM PIER REMIT REWIRED FOR THE LOADS TABULATED ABOVE p ��-t`''•!%1��g6r ' ��;� FED �,�, (�• t'? l Ar`. •' \���� RAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STAND LD JACOBSEN HOMES NOTIC& �> nnI I TNESESPECnCAnONSAND ORAWWCSARE 1 of . R.R. DATE: 8-27-96 REV. LETTER S BOX 368 OPodNAL. PROMETARY. AND CotinDENTML MATERIALS OF JACOBSEN MANUFACTURMIC ARE PROVTHE BP.O. DRAWING TIRE- OFFSET SPACING TABLES SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 REpPIENF rOt gE�s NqO ORAMING NUMDER 17PT C"WnX AND SECRET FROM o11E1t5 AU—To-0020 39 ADDENDUM z OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING TIE -DOWN SPACINGS FIGURE 3.0 SEE FIGURE 4.0 FOR ALTERNATE TIE -DOWN METHOD TYP. CROSS SECTION(S) SHOVING TIEDOWNS SEE NOTE 5 FOR MNmAUY ffIGLFT [TABLES ON /AID-OD20 DM APPLY III TO TRE3E STANOARO {A1LTI-EWE SECAOIS OF THE UNIT -SEE NOTE 1, AD-1D-Ml TYP. FLOOR SYS10d-7 III TYP. CROSS -MEMBER ANCHOR ANGLE ANDIOR ANGLE ANGLE ANGLE FIGURE 3.1 FIGURE 3.2 SEE FIGURE &0 FOR ALTERNATE TIE-DOAN METHOD �ALTERNATE TIE -DOWN METHOD DAPIA APPROVAL• NOTES: .`�` O ' G�STFR •' cc � 1. SEE AD-TD-0020 FOR SPACING TABLES (OFFSET SECTION ONLY). �� Q�' N 0. gyp' ' v APPROVED BY gyp. 2. SEE AD-TD-0020 FOR OUANITY OF LONGITUDIAL TIE -DOWN STRAPS REQUIRED. (OFFSET SECTION ONLY) _ ENE8703571 z 3. SEE OTHER DETALS FOR BLOCIONG (PIER) QUANTITY AND OTHER REQUIREMENTS. _7N rfl i` 4. SEE AD-TD-000I FOR ADDITIONAL REQUIREMENTS. INC 5. ZONE 2/EXPOSURE 'C': 44- MAXIMUM HEIGHT %��'• //L�L7L f.'�� F V Ley ZONE 2/EXPOSURE 'D': 24' MAXIMUM HEIGHT (32' ®24' WIDE MIN.)ZONE 3/EXPOSURE V: 32' MAXIMUM HEIGHT ii �t`�'•.,...... .' ZONE 3/EXPOSURE V.- 32' MAXIMUM HEIGHT (44' 0 24' WIDE LAIN.) ���''%,s�ONAI JACOBSEN HOMES NOTFCE THEE sPECIFICAnoNS AND DRA1MNGs ARE DRAWN BY: C.L.Y. DATE 5-11-95 REV. LETTER: ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTLA�ING DRAYTING TITLE:Lium FIG. 3.0, 3.1 & 3.2 n ,\ ❑„❑ P.O. BOX 368 INC. SUCH MAMMALS ARE PROVIDED TO THE '/ SAFETY RRPogSD DRAWING NUMBER: PHONE (813)F726'D1384695RECIPIENTFW� SECRCT � � AD—TD-0021 40 ADDENDUM ALTERNATE OFFSET UNIT TIE-DOtiVN SYSTEM TYPICAL SIDE ELEVATION (WI OFFSET SECTION) SHOWING TIE — DOWN SPACINGS FIGURE 4.0 SEE FIGURES 3.1 AND 3.2 FOR TYP. CROSS-SECTION k 0 ``Er..OV CC0���4 DAPIA APPROVAL 1. SEE AD-ID-0020 FOR SPAO4, TAKES (OFFSET SECTION ONLY). '�O ��6 SOE•9�O APPROVED BY. 2. SEE AD-TD-0020 FOR OUANITY OF LONGi MAL TIE -DOWN STRAPS REOUIRFD. (OFFSET SECTION ONLY) Z PE8703571 I- - S 5 3. SEE OTHER DETAILS FOR OLOCENG (PIER) OUANTITY AND OTHER REWROo(NTS. _ 4. SEE AD-TD-ODO1 FOR ADDITTCCAL REOUIREMENTS. _ • r. INC, Qr C); '`F�•.NCl1AN�'•� �. co,iwc,orroyvst.twcw rJAL ■ JACOBSEN HOMES P.O. BOX THESE SPEDfiGT104 uro DRAW= ARE WONAL. PNOPPoETART, AND COti10DITIAL MATERIALS OF , MSD UARNACIUaNG T1RAwN BY. C.L.Y. DAB' 5-11-95 R>y LETTM /► A. DRAwWG TIM B�ryry 4.0 „ SAFETY HA?oOR. FLOORIRi DA 34695 9" MAtE%" Aa PSI%= TO TICnG. OIG uOPprt ►R start PLIMM wo SET x DRAWING NUMBER PHONE (813) 726-1138 PVT to MTA AM WOO no OTIM A0-M-0022 41 ADDENDUM ALTERNATE UNIT TIE -DOWN SPACING TABLES Q ZONE II & III/EXP. C & D / LONGITUDINAL TIE -DOWN SPACING TABLE (+1 MIN. WIND ZONE it WIND ZONE III VIN.OTY. ANCHOR MIN.OTY ANCHOR C �J FLOOR WIDTH EA. END N EA END ANGLE O� oN EA. SECTION MIN. a EA SECTION MIN. e 20'-0' 2 36' 2 45' 24'-0' 2 46' 2 60' 254 2 50' 2 67' 26'-8' 2 55' 3 M. VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DBL OAD ANCHOR ANGLE SPACNC DBL HEAD LOAD ANCHOR ANISE FLOOR WIDTH EAVE OVERHANG 26-0' 12' 4'-0' 36701 20' 4'-0' 3900# 20' 24'-0' 12' 4'-0' 37001 20' 4'-0' 3950# 20" 254 12' 6'-8' 40001 15' 4'-0' 39501 22' 26'-8' 12' 6'4 39501 28' 4'-0' 3950# 22' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III MIN. Ott. ANCHOR u1N Ott. ANLE FLOOR 4DTH EA END OF ANGLE EA. END OF ANGLE �g 0� EA SECTION uDL B EA SECT0 MIN. 9 20'-0' 2 50' N/A N/A �•�4 24'-0' 2 70' N/A N/A 25'-4' 3 42' N/A N/A 26'-8' N/A N/A N/A I N/A VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DBL HEAD DBLANCHOR ANGLE SPACINGLOAD DBL HEAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 20'-0' 12' 4'-0' 40001 20' N/A N/A N/A 24'-0' 12' 4'-0' 40001 24' N/A N/A N/A 25'-4' 12' 4'-0' 40001 26' N/A N/A N/A 26'-8' 12' 4'-0' 40001 2T. , ,,,,I .11, N/A N/A N/A NOTES: ENCI%il PR,!t1-p0� "Opt DAPIA APPROVAL• 1. SEE FOR ADDITIONAL REOUIREIIENTS Qr.;`* \S t QFO. /Ij �ii _ _ -• _ • _ ... . AD-TD-0001 ` �: No. _ 2. SEE AD-TD-DO31 FOR MAXIMUM PIER HMT REOUIRED FOR THE LOADS TABULATED EINES703571ABOVL 3. 20 W1DES -82' MAXIMUM I -BEAM SPACING ONLY. 6%2�}7 •J - — 4. 4' MAXIMUM INSET TO ANCHOR HEADS (SEE AD-TD-0031). i•'' �^/ C' :` _ ... ...- . JACOBSEN HOMES N077CE Ttt 19RNMN' THESE SPE011CATIONS AND DRANNGS ARE C.L.Y. DATE 6-13-95 REV. LETTER: TITLE ALT. SPACING TABLES OIEONAL PROPRA:TARY. AND CONI1001TM1 DRAMNG MATERIALS OF JACOBSEN MANNACUM P.O. BOX 368 SAFETY HARBOR. FLORIDA 34695 INC_ SU01 MATERMLS ARE PRMDED TO THE 9011INT rOR SPEC4lc KffM AW mat K ORAMING Onus NUMBER: AD—TD-0030 PHONE.(813) 726-1138 MT COI WR4 AND SEOtET ROM 42 ADNDUM o �,00* ALTERNATE TDEEDOWN SYSTEM(S) ,00 � TYPICAL CROSS SECTION SHOWING TIEDOWNS SST NOTE 4 FOR MAUM HEIGHT L FIGURE 5.0 4' MAX VW SEE FIGURE Ll FOR RECOID[F?IDED W-DOI IN, fflHOD . IMPORTANT NOTICE: THIS ALTERNATE APPLICATION REQUIRES 4,000. POUND ANCHORS na USING THIS TIE-DOV CONEGURATION A STYLE CREST PRODUCTS MODEL 57SH (TYPE 21 AUGER ANCHOR MTH. A DESIGN WAD (TORENG LAID) RATING OF 4,000 POUNDS AND AN ULTBUATE IDAD HATING OF 6,000 POUNDS MUST BE USED. AN EQUIYIIART ANCHOR MEETING THE ABOVE SPECIFICATIONS 1UIDE'BY ANOTHER KMACTURER MAY BE USED IN IEU OF THE S= CREST PRODUCES ANCHOR b S: THE ALTERNATE TIE -DOWN METHODS SHOWN ABOVE ARE ACCEPTABLE FOR USE IN I 'D', ALL WIND ZONES AND PI BOTH EXPOSURE 'C AND EXPOSURE HOWEVER, BY 1. SEE AD-TD-0001 FOR ADD1710NAL REWIREMENTS INSTALLING THE FRAME 71E-DOWN STRAPS AT THE 'OUTBOARD' I -BEAM THE MAX 2. SEE OTHER DETAILS FOR BLOCIONC (PIER) QUANTITY AND OTHER REOUIREMENTS HEIGHT OFT THEY REDIM SEE OTHERDETAILS FOR THE nA METH�FORG�NSTNG 1E RECOMMEND3. FOR FIGURE 5.0 SEE ALTERNATE TE-DOWN SPACING TABLES (AD-TD-DO30). EH,3R PROVALy1 ^ ' •;� `�R V4� DAPIA APPROVAL' 4. ZONE 2/EXPOSURE 'C% 3TC MA)w..OM HEIGHT 'D': MAX%IJM HEIGHT 2/EXPOSURE 27' ZONE 3/EIPOSURE'C': 30' MkafJM HEIGHT ����` ��'i� O �1STEy ...� ��� _ • - - _:;- _ •_ ZONE 3/EXPOSURE TI': THIS APPLICATION IS NOT APPLICABLE. No, r 1 ENES7012 PIZ 01A NOTICE: 'I'Ini CRAWN BY: C.L.Y. DATE 6-13-95 REV. LETTER: JACOBSEN HOMES THESE SPEOTICA➢OHS AND DRAWINGS ARE ORAWNG 71TlJ : FIG. 5.0 A CRIONAL. PROPMETARY, AND CCNTMTK MATERIALS OF OXOtiSEN MAHuFACT"G P.O. BOX 368 SAFETY. HARBOR. FLORIDA 34695 DEC. SUCH MATERULS ARE PROVIDED TO THE - REWW FOR SRCEIC ROM AM VM BE DRAWING NUMBER AD-TD-0031 PHONE (B13) 726-1138 JUT CD MTLAL APO SECRET INDM OTMM 43 ��cl��t '10 1•N��� , ADDENDUM Res �aRs ►��►� R�Q� "� 'I"-- C�� ALT. OFFSET UNIT TIE -DOWN SPACING TABLES 51 �' 6 ZONE II & III/EYP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE Mill WIND ZONE II WIND ZONE III FLOOR MIN. Ott• ANCHOR MIN.OTY. ANCHOR S `4 MDTH EA END N EA ENO OF N E.A. SECTION YIN.. 9 EA gCTICN MIN.6 20'-0* N/A N/A N/A N/A 24'-0" 2 42' 2 53' 10� 25'-4' 2 45' 2 58' 26'-8' 2 48' 3 3-7 ° VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING Del. HEAD LOAD ANCHOR ANGLE SPACING DBL HEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 20'-0' 12' N/A N/A N/A N/A N/A N/A 24'-0' 1 12' 1 4'-0' 40001 20'-30' 4'-0' 4000# 20`-30' 25'-4' 12' 4'-0' 40D0 j 20'-30' 4'-0* 4000# 20'-30' 26'-B' 12" 4'-0' 40D0j 20'-30' .4'-0' 4000# T 25'-30' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. HIND ZONE II WIND ZONE III MIN. Ott. ANCHOR UK OTY. ANCHOR FLOOR WIDTH EA. END OF AN A EN ED OF ANGLE EA ACTION YIN.. B EA SECTION YIN. 9 20'-0' N/A N/A N/A N/A 24'-0' 2 60' 3 45' 254 1 2 1 66' 3 1 48. 26'-8' 1 3 1 41' 3 52' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DeL. HEAD LOAD ANCHOR ANGLE SPACING Del. HEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 20'-0' 12' N/A N/A N/A N/A N/A N/A 24'-0" 12" S-8' 4000 f 20'-30' 2'-8' 4000# 20'-30' 25'-4' 12' 4'-0' 40001 25'-30' 3'-2' 1 4000# 15 -30' 26'-8' 12' 4'-0' 40001 25'-30' S-2' 4000# t 25'-30' NOTES: ENGINEER IffieNUmN1///� DAPIA APPROVAL: 1. OFFSET SECTION WITH THE MARRIAGE LINE WALL DaENDDiG BEYOND THE ENDWALL OF ���\Y C"DO''�� CO'• E9,t`'�o��'� PPROVED BY THE ADJACENT SEC110N MUST BE TIED DOWN AT THE MARRIAGE LINE IN ACCORDANCE PATH THE TABLES ABOVE. THE SIDEWALL SIDE AND THE ADJACENT SECTION(S) ARE TO ��`�•'�G i�0. _ �1 1 4 BE TIED DOWN IN ACCORDANCE YATH THE ALT. SPACING TABLES (AD—TD-0030). E r.I?i -ON I INC, 2 SEE AD—TD—OD01 FOR ADDITIONAL REQUIREMENTS.ST FOR PIER _ • 1 : �• m 3. SEE AD—ID-0033 MA)<IMUM HEIGHT REQUIRED FOR THE LOADS iA8UU11ED ABOVE i 0: • �. •., y Q7� �.�..'a�� JACOBSEN HOMES NOTlC9'. ���� L' THESE SPEaT1CAum AND O vmMs'/I 1 % r`%%k 1„,`` C.L.Y. DATE: 5-30-95 REV. LETTER DRAWING TITLE ALT. SPACING TABLES LHE P.O. BOX 368 MAGNAALSROWF JAC M MAN1LW SAFETY HARBOR. FLORIDA 34695 PHONE (813) 726-1138 W_ SUCH MATERIALS ARE PpOMOm TO THE REOPOR rat Spam RJv= NO WST K IVT a 14WITIAL MD SEOU maM ORM DRAWING NUMBER: AD-TD-0032 dd �E mcp 15N°`'1 OIL ADDENDUM `11 ` cs g ALTERNATE TIE - DOWN SYSTEM TYP. CROSS SECTION(S) SHOWING .WDOWNS SEE NOTE 5 FOR MOM HF1tiiT mu ANIEE [TAli1:5 0; WS-OOS2 GOO APPLY TO M STA1I= MULT;41 mcm G THE UNIT -STE MOLE 1. AD-ID-00,T7.) TOP. FLOOR SYSTEM7 ANCM ANOE TV. mom ANOIE FIGURE 6.0 FIGURE 6.1 SEE FIGURE 0.1 MR RECOMMENDED 71E—DOWN METHOD SEE FIGURE 12 FOR RECOMMENDED TIE —DOWN METHOD IMPORTANT NOTICE: THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS THEN USING THIS TIE—DOI,,1 CONYIGURATION A STYLE CREST PRODUCTS YODEL 57SH (TYPE 4j AUGER ANCHOR TRH A DESIGN LOAD (TORKI NG IOAD) RATDIG OF 4,000 POUNDS AND AN ULILYIIIT: LOAD RATING OF 6,000 POUNDS MUST BE USED. AN EQUIVD,ANT ANCHOR MEETING THE ABOVE SPECMCATTONS MADE BY ANOTHER MANUFACTURER MAY BE USED IN 1EU OF THE SLYIE CREST PRODUCTS ANCHOR THE ALTERNATE TIE -DOWN METHODS SHOWN ABORT: ARE ACCEPTABLE FOR USE N I. SEE AD-TD-0001 FOR ADDITIONAL REOUIREMENTS. ALL WJID ZONES AND N BOTH EXPOSURE 'C' AND EXPOSURE V. HOWEVER, BY 2. INSTALLING THE FRAME TIE-DOWTN STRAPS AT THE 'OUTBOARD' 1-BEAM THE MAX SEE OTHER RETAILS FOR BLOCIONG (PIER) QUANTITY AND OTHER REOUIREMENTS, HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR THE 3. FOR FIGURE 6.0 SEE OFFSET UNIT TIE -DOWN SPACING TABLES (AD-TD-002OZ RECOM1IEADED KU M FOR INSTALLING FRAME TE-DOWNS. FOR FIGURE 6.1 SEE NORMAL TIE -DOWN SPACING TABLES (AD-TD-DOTO). ENCOM III, DAPIA APPROVAL - (ALSO SEE AD-TD-0020 AND AD-TD-0021) �., % Dqt J4, ZONE 2/ENP�RE V.- 24 MAXIMUM T�T � � PPROVED BY ZONE 2/EXPOSURF 'C': 2V MA70 U HEIGHT�OG, Np �Fp 2'': ZONE 3 ZONE J/EXPOSURE TT': 28• MAXIMUM HEIGHT E87 ' S INC .v Nonce " CLY. DAB 5-30-95 REV` LETTERI JACOBSEN HOMES THMSPEOnCATMS ANg RAW=L;r „ MATDiP.O. BOX 368 �ALS COW VMFAC7UW SAFETY HARBOR, FLORIDA 34695 "- WN MATUWS ARM PROW= To THE FIG. 6.0 & 6.1 REM M FOR 7EOFIG M"KS AID W 6E DRAWING NUMBER: PHONE (813) 726-T138 Tarr COWDENTIAE NO Nor mom OU.M AD—TD-0033 G• ADDENDUM ALTERNATE TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE (+� MIN. W,ND ZONE II WIND ZONE III W.N.OTY ANaGR YIN. ITT. MOOR FLOOR WIDTH EA ENO OF AN EA. END OF ANGLE 1� EA SECTION UN.. a EA SECTION YItK B 12'-0' 2 43' 2 55' 13'-4' 2 50' 1 2 68' 10 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MN. MAX. WIND ZONE II WIND ZONE III SPACING D' HEAD LOAD ANCHOR ANGLE SPACING DBL HEAD LOAD ANQOR ANGLE FLOOR WIDTH EAVE OVERHANG 12'-0' 6' 4'-0' 37501 20' 4'-0' 39001 22' 13'-4' 6' 5-4' 38501 25' 1 5'-4' 3960# 30' THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III Y.N. Y.O ANCHOR T.O ANCHOR FLOOR WIDTH D EA END O fA SECTION ANGLE YIN. 6 EA END O A. E D EA. SECTION ANGLE YDl 6 O v V 12'-0' 2 64' 3 47' 12'-0' 3 37' 4 33' 13'-4' 3 42' 3 55' 13'-4' 4 30' 4 38' VERTICAL TIE -DOWN / FRAME TIE' -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACRG D EL o� ANCHOR ANGLE SPACING D oKEAD AD AN04OR ANGLE FLOOR WROTH EAVE OVERHANG 12'-O' 6' 4'-0' 39501 25' 2'-8' 3930# 20' IS-4' 6' 4'-0' 39EOJ 25' 2'-8' 40001 30' THIS ALTERNATE APPLICATION REQUIRES 4, POUND ANCHORS ,,000 NOTES ENpINE�NS%`PR�L OF������ DAPIA APPROVAL 1. SEE AD-ID-0001 FOR ADDITIONAL REOUREMENTs No 9FoF2��'. APPROVED BY 2 SEE AD-TD-DO76 FOR MAXIMUM PIER HEWTS REOIARED FOR THE LOADS z: �i TABUlA1ED AM_ EN �8703571 _ 5 NIP 3. MAX EAVE OVERHANG REFERS 10 OVERHANG AT SIDEWALL NOT FRONT OR REAR. = INC 4. ABOVE TABLES APPLY TO 160' FLOOR OR 144' FLOOR WIDTHS WH 95 1/2' y�p�;•., 6 '4' N ..� ������ �01 wcraAlOiy;TT I -BEAN SPACING 96' MAXIMUM SIDEWALL HEIGHT AND 6- MAM M SIDE OVERHANG (6' OVERHANG MAX EACH SIDE OF LINIT� fit` • • (�\ �• JACOBSEN HOMES NOTICE 'ffj TNESE SPEOFlWTIONS AND MUM ARE CMQNN.TRUPROPRICTART. AND 001610DIT1AL �NF� C.L.Y. DATE 5=30-95 REV. LETTER: A DRAWING TITLL' SPACING TABLES P.O. BOX 368 MATLS OF JACOM M"FACIMNO ALT. „ SAFETY HARBOR. FLORIDA 34695 LLIJU PHONE (813) 726-1138 PEEOOPoOT SUOI CR SPE�CTIC RIFF' 0 AM N l K OUT CWMRu MO SE00 rRa OHM DRAWING NUMBER: AD-TD-0040 46 o c*,s -OVO ADDENDUM ALTERNATE TYPICAL CROSS SECTION SHOWING TIEDOWNS TIE -DOWN SYSTEM ANGLE ANGLE FIGURE 7.0 SEE FIGURE L3 FOR RECOMMENDED TTE-DDTN METHOD IMPORTANT NOTICE: SEE NOTE 4 FOR MAXMUM NIGHT THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS itQ;N USING THIS TIE -DOWN CONFIGURATION A STYLE CREST PRODUCTS YODEL 57SH (TYPE 2� AUGER ANCHOR TTIH A DESIGN WAD (TORKBIG TDAD) RATING OF 4,000 POUNDS AND AN ULTBIATE LOAD RATING OF 8,000 POUNDS MUST BE USED. AN EQUIVI,ART ANCBO$ WEEPING THE A80VE SPECIFICATIONS MADE BY . ANOTHER MANUFACTURER YAY BE USED IN IJEU OF THE STYLE CREST PRODUCTS ANCHOR. 1. SEE AD-TD-000I FOR ADDITIONAL REQUIREMENTS 2. SEE OTHER DETAILS FOR BLOCKING (PIER) QUANTITY AND OTHER REQUIREMENTS. 3. FOR FIGURE 7.0 SEE ALTERNATE TIE —DOWN SPACING TABLES (AD—TD-0035). a. ZONE 2/EXPOSURE 'C': 38' MAXIMUM HEIGHT ZONE 2/EXPOSURE 'D': 28' MAXIMUM RIGHT ZONE 3/EXPOSURE 'C': 28' MAXGUM HEIGHT ZONE J/EXPOSURE 'D': 28" MAXIMUM HEIGHT 5. SEE AD—TD-0035 FOR ADDITIONAL NOTES THE ALTERNATE TIE —DOWN METHODS SHOWN ABOVE ARE ACCEPTABLE FOR USE IN ALL MIND ZONES AND IN BOTH EXPOSURE 'C' AND EXPOSURE '0'. HOWEVER, BY INSTALLING THE FRAME TIE -DOWN STRAPS AT THE 'OUTBOARD' I -BEAM THE MAX HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR THE RECOMMENDED METHODS FOR INSTALLING FRAME TIE -DOWNS. G %S T No. FO?' NEa� STATE QF ••.liyo'�4; ; ..1 APPROVED BY ONI*141NC cow.+.��•,wwmtTarow JACOBSEN NOnCR .�Alplll Ij��' C.L.Y. IA" 5-30-95 IRK LLIIuc HOMES THESE sKanCAnm AND NAVOS ARE >" P.O. BOX 368 CIOONAL. PRCPIKTAft. AND CCMKxxlm MATERIALS OF JACOBSEN MANUFACTURRNG DRAWING TITLE - FIG. 7.0 n SAFETY HARBOR. FLORIDA 34695 NG SLXN MATEIMS ARE ROOM TO THE RFDPENT FOR gum AUAUgRs AAO um I E 'H` DRAWING NUMBER PHONE (813) 726-1138 IVT CDNIMTIAL AND SECRET nNM OTNEIM AD—TD-0041 47 ADDENDUM MISC. TIE -DOWN PROTECTION OF STRAP IS PROVIDED AT UPPER CORNERS BY FIRST WRAP OF STRAP. SEE DETAIL 'B' SEE DETAIL DETAIL ' A' WCKLE WITH 31501 Y MINIMUM (DESIGN LOAD) DETAIL 1 B' -BEAM LL DOWN TIGHT TO DUND ANCHOR INSTALL RADIUS CLIP (SEE AD-TD-0200) OR SIMILAR DEVICE TO PROTECT STRAP .AT ALL SHARP CORNERS. DETAIL I C' THIS TYPE OF PROTECTION MAY BE USED FOR %01911LI; LONGITUDINAL TIE CONNECTIONS ALSO. �. ST/� /yF. EIl§ft`• ' �� q • �.� DAPIA APPROVAL : Q No. '•. = APPROVED EY 1. SHOWN ABOVE IS ONLY ONE METHOD OF STRAP ATTACHMENT 910334 AT BEAM —OTHER METHODS THAT ARE CERTIFIED TO MEET = oeo =TkimANuFACTUREID THE REQUIRED DESIGN LOAD OF 3150# MAY BE USED. — FEDEM 2. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS '• STATE OF WHERE THE ANCHORING SYSTEM REQUIRES THE USE •'••,/OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). ��F ' IA�•' `�� pN ME D AND it FREED OTHERS NOV 2 4 1998 NOTICE DRAWN BY: DATE REV. LETTER: JACOBSEN HOMES THESE sPEonCATI MS AND DRAWNSS ARE M.T. 11-18-98 UAATMA s COBB� MANUFACTURING c �ArvINc TITLE: MISC. TIE -DOWN B P.O. BOX 368 INC S= MATMALS ARE PRDVW TO RE SAFETY HARBOR, 'FLORIDA 34695 RECQEHT FOR SPECFlC PURPOSES AND YUST BE DRAWING NUMBER: PHONE (813) 726-1138 KMT CCNn"TIIL AND SECRET FROM OWK AD-TD-0050 40 ■1 ADDENDUM 1 NORMAL TIE -DOWN SPACING TABLES S D 1 ZONE II & III/EXP. C & D ' II LONGITUDINAL TIE -DOWN SPACING TABLE MIN, WIND ZONE II WIND ZONE III FLOOR UK CITY. ANCHOR UK Qn ANCHOR H9DiH EA. END OF ANGLE EA DO OF ANGLE I ^ O u stcna+ um e u sEcnor+ Im+. e 30'-8' 3 40 3 25 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE IN. OOR DTH MAX EAVE OVERHANG WIND ZONE II WIND ZONE III SPACINGA4aOR D3L LOAD ANGLE SPACING DL OAAD ANCHOR ANGLE 3 '-8' 6' 6'-9' 31501 41-46 5-5' 31501 1 44.-49 4 , O� LONGITUDINAL TIE -DOWN SPACING TABLE MIN. FLOOR MOTHEA.END RAND ZONE 0 WIND ZONE pl I L, on OF EA. SECTION ANm ANGLE MIN. 0 UK QTY. Lk END OF EA. SECTION ANCHOR ANGLE Ind. 8 36-8' 4 42 4 25 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX WIND ZONE Q WIND ZONE 10 OOR EAVE SPACING DL KAD DTH OVERHANG LOAD ANCHOR ME SPACING " la AN ANGLE LOAD 6' 4'-6' 31501 46-50 4'-0' 31501 49-52 VANDZONE III (110 MPH) 20 PSF ROOF 10 PSF D.L REF. CALcs. G 'V� ' '74,0/— C%¢. 6 ,,ti1t11111111/,/,, qOl ES.• EN`f : `y 4DAPM, APPROV"LIAR Q 1. E FULL ADDENDUM FOR ADDIIIH><1N. REQUIREMENTS.� S � No.. o' APPROVED 8Y 2. UE AD-TD-0071 FOR MAXIMUM PIER HEIGHTS REQUIRED FOR THE LOADS 910334 ABULATED ABOVE. -TA OF.- ROtAQwM/1C101�DIdE INC. Swill-.C: Unnnn al: DAIC nLy. LULL. A OBSEN HOMES THESE SEOIICATICKS AID ORxAM ARE. M.T. 2-8-99 ■ ORIGINAL PROMIA". ANO OON&"UAI DRAMANC TITLE: P.O. Box 368 MAWRIALS aF "umrAmvic NORM. SPACING TABLES SAFETY HARBOR, FLORIDA 34695 LNG 9" II MAI.i ARE PROvm 10 R[CMT 7OR SPECM PAVO Alp WM BE DRAWNG NUMBER PHONE (727) 726-1138 IVI WMDO Ml AND SEOM rRm oroM AD—TO-0070 49 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE —DOWN SPACINGS MAX nx AU-IU-OOIU Imu HR AU-I�WIV IML nX NY-IU-WIU IAtLL FtX AU-IU-W U IALU nX AU-IU-Mg IALU m FIGURE 10.0 SEE FIGURE ZO FOE ALTERNATE TIE -DOWN IMD TYPICAL CROSS SECTION SHOWING 11EDOWNS T" 7DDR °' 11P QtO ' 1 11 ausss SEE 101E 5 FOR No" HEMiHT AKH(IR &%E _ Rim SET µpm NANDZONE III --� FIGURE 10.1 21 P ( SEE FIGURE 50 FOR ALTTIRIM =-DOWN W MD SF ROOF 10 PSF D.L REF. CALCS.-'1111111111-1, , DH •.. C ., VAMA ArYKUYAU. NOTES: v; •T E - e N0. o'•. 1. SEE AD-TD-0070 FOR SPAM TABLES = � APPROVED BY 2. SEE AD-TD-0070 FOR QUANITY OF LONG11WAL TIE -DOWN STRAPS REQUIRED. 91033400 • •: 3. SEE OTHER DETAILS FOR BLmw (PER) OUANOTY AND OTHER REOUREMENTS. * : ON o®B 4. SEE FULL ADDENDUM FOR ADDITIONAL REOUREUMM ,.A • STATE OF ' 5. ZONE 2/EWOSURE 'C': 56• MAXIMUM HEIGHT *',��it`•' i/VD1lQ�:P• �c INC. ZONE 2/EX�OSORE 'D% 4O' MAXIMUM HEIGHT �, 4t` � `� nDEpp wmwc,uWEI "ow IRE ZONE 3/0FORV: 56' MAXIMUM HEIGHT 'ii cox��wcllollAlosA�nrsuroolms ZONE 3/E>0'MK'0% 40* MAXIMUM HEIGHT s� ..�' NOTTC: DRA M.T. T DATE 3_1-99 REV LETTETR: JACOBSEN HOMES >��I>�Tm F DRA NGSARE CRIGNAL PROPIEETARY. NO CONFMU#L DRAWING ERITITLE: „ MATALS OF JAWS" MANUFACURIC FIGURES 10.0 AND 10.1 P.O. BOX 368 W_ SIRH MATERAIS ARE PROWWO TO 7H= SAFETY HARBOR. FLORIDA 34695 REamwi FOR SPM PIAdM AND MST BE DRAWING NUMBER: PHONE (727) 726-1138 WT t muomAL AND smu FROM oum AD-TD-0071 50 ADDENDUM. g�S NORMAL TIE -DOWN SPACING TABLES &, 1 ZONE II & III/EXP. C & D 1� LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE d WIND ZONE 01 FLOOR MRoTx AHa+oR ZK_dTT__ ANCHOR WIDTH EA. CND OF ANGLE EA DO OF ANGLE EA. SEcmR MR. O EA. SECTION MIN. 0 15'-4' . 3 45 3 35 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. FLOOR WIDTH 154 MAX. EAVE OVERHANG 6' EACH SIDE SPACING 6'-10' WIND ZONE II D OBIL AD ANCHOR ANGLE WIND ZONE III . SPAONG DL HEAD LOAD ANCHOR ANGLE 40-46 5'-6* 31501 42-47 LONGITUDINAL TIE —DOWN SPACING TABLE t c4 O� I MIN. FLOOR WIDTH WIND ZONE II WIND ZONE III UN. OTT. EA END OF EA SECTION ANCHOR ANGLE MIN. 9 YRL OTtt EA. SE OF Gl SECTION ANCHOR ANGLE UK 6 15'-4' 3 30 4 35 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN• FLOOR WDTH 15'-4' MAX EAVE . OVERHANG 6EACH SIDE 1 SPACING 4'-6• WIND ZONE 11 ors. H_AD LOAD 31501 ANm ANCIE WIND ZONE lU SPAONG DOL HEAD Low mm AHCtf 42-50 4'-0' 3150�. 44-50 I. SEE FULL ADDENDUM FOR ADDITIONAL REQUIREMENTS. 2. SEE AD-TD-0073 FOR MAXIMUM PIER HEIGHTS REQUIRED FOR THE LOADS TABULATED ABOVE 3. MAX EAVE OVERHANG REFERS TO OVERHANG AT SIDEWALL NOT FRONT OR REAR. 4.i1 ABOVE TABLES APPLY TO 184• FLOOR WIDTHS WITH 95 1r2' I -BEAM SPACING, 96• MAXIMUM SIDEWALL HEIGHT AND 6 MAXIMUM SIDE OVERHANG (6- OVEF6WC MAX EACH SIDE OF UNIT). JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR. FLORIDA 34695 PHONE (727) 726-1138 VANDZONE III (110 MPH) 20 PSF ROOF 10 PSF D.L cw4—�2.a1- -72, . G\STE.9 No. 910334 STATE Cf THESE 9'EWWATIONS AND DRA;MCS ARE ORIONAL. PROPPoETAR`. AND C*MNIIAL YAIERIALS OF JACOBSEN U~ACTURwc O+C 9rCR UATMALS ARE PROVIDED TO THE RECnENT rOR WEE C PLVMS Aro WAT DE nPT CCMIDENIIAL AND SECRET rROY OTHERS. DAM APPROVED BY I.NPINC. r(Q tLL N/MRAt711iD 10E oDIaTnICIR�+wowtfrstwo�R01 M.T. I DAIS: 2-8-99 NORM. SPACING TABLES t AO-TD-0072 51 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION MAX PER AD -ID -WIZ lku ruc It- -wic 1 •�• •� ^- - - - FIGURE 10.2 SEE FIGURE 20 FOR ALTERNATE T[E-DOVN iMD TYPICAL CROSS SECTION SHOWING •TIEDOWNS s SEE NOTE 5 FOR MApINN HE10HT N ANaE SET IN HEAD I �ti.� �.... VIWNDZONE III OF HOME (,�, SIDEFIGURE 10.3 (110 MPH) SEE FIGURE 7.0 FOR ALTERNATE TIE -DOWN ![),TROD 10 PSF ROOF i 0 PSF D.l. REF. CAECS L k� - G� 2 . �% r 9 Z • Imo/ � L,,1111111111111/AI � DAM APPROVA: EN NOTES: re� 1. SEE AD-0072 FOR SPAM TAMS AM NOTES. No. o'•. � APPROVED BY -TD 2 SEE AD-TD-0072 FOR OUAKITY OF LONGITUDIN. TE-DOWN STRAPS REOUFiED. 910334ON r14 3. SEE OTHER DETAI S FOR BLOCI(NG (PER) OUANTITY AND OTHER RE0111REMENTS. �.� k 4. SEE FLIL ADDDON FOR ADDITIONAL REOUREMENTS .o STATE OF 5. ZONE 2/C POURE SV: 56' MAXIMUM HEIGHT IBM : �O • Q, • k. rvnwzlul® INC. • ` �J NOE ZONE 2/E1�OSOSIURE b': 56 ' uAXIMUM Hr7CFlT DIA� ' �j3 ..� ZONE 3/EPI@E 'C': 56' MAXIMUM HEIGHT �4� ZONE 3/DpMK V.- 56' MAXIMUM HEIGHT s . -- 19 JACOBSEN HOMES „ P.O. BOX 368 Ll SAfM HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE:" THESE SPECIFICATIONS AND DRA ARE ORIMIAL. PROPRIETARY. AND CONFIDENTIAL MATERIALS OF ACOBSEN MANUFACTURING INC SUCH YATMALS ARE PROMDED TO THE RECPIUIT FOR SPECIFIC PIFFM AID VUST BE PVT CONFDENIUL AND SECRET FROM VDIM DATE M.T. 3-1-99 FIGURES 10.2 AND -10.3 L AD-TD-0073 ADDENDUM �s S _ OFFSET UNIT TIE DOWN SPACING TABLES 11,E ZONE. II & III/EXP. C & D 11 LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE I WIND ZONE Ill ►R OTY. ANm ML oTr. WHIR V FLOOR WIDTH Ell END OF ANGLE EA. END ON ANGLE EA SECTIdI MREA B SECTON tE1. e O� 3 41' 3 61' II 15'-4' 2 54' 3 41' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WIND ZONE I WIND ZONE II SPACJfIG ML L UA ARM AN(iE SPACHG °BLiOAD� ARM ANGLE WID OVERHANG 12'- 12' 5-0' 31501 4p• 4'-p• 31501 39' 13'- 12' S'-0' 31501 41' 4'-0' 3000# 40' 15-4 12' S-0' 3150 43' 4'4 30001 42' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE I WIND ZONE NI MR OTY. EA END OF ANm ANGLE MR OTY. EA. . ANCHOR FLOOR II ®� WIDTH EA. sEcnaN HL a EA. SEC11o11 SEC O IL1E � e 12'-0° 4 45' 4 60' 13'4 3 45' 3 60' 154 3 45' 3 60' .VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN MAX. YMND ZONE I WwD ZONE Q SPACING DBI. HEAD In ANOU AM SPAM �' HID In NMMG E FL WID EAVE OVERHANG 12' 12' 4'-0' 31501 40' 3'-0' 30001 38 12' 4'-0' 3065i 41' 3'-0' =f. 39* 15- it 4'-0' 3OW 43' 3'-0' 30001 41' NOTES cif - 441G51 c-sL- 16 12- awl nPM01140811 REF. CALCS C-• U— 17�G - �oo ",A.c. DpF ��+. O�' a►� 17,4 1. TIE SECTION ITH THE NAMAGE LIE WALL EXIF 04 BEYOND THE ENDIWAIL OF SECTION UMBE TO DOWN AT THE MARRIAGE 111E IN ACCORDANCE �A •... •.,� • ��.'��l'C1F1C,gf :• ff&,tD BY �4 � WITH TAKES ABODE. THE SIDEINALL SIDE AND THE ADJACENT SECTION(S) ARE TO BE DOWN IN ACCORDANCE WITH THE NORMAL SPACING TABLES (SEE AD-TD-0010 ' jUN I I . FOR 1 -0 t 13'-4' TNDES, AND AD-1D-0070 FOR 1S'-4• WDES� w * 2 SEE 1D-0001 FOR ADDITIONAL REWREIMS. STA INC.. 1 SEE iD-OOBI FOR MA1tlABJlt PER HEIGHT REQUIRED FOR THE LOADS TABULATED . .` Q. •; ORIU4;•• �44..` LMANUMMIRED"WE JACOBSEN HOMES T" SPEOWATM AMAMA : Ws`1A T DATE. 6-8-04 REV. LEM °RANG 111LE' OFFSET SPACING TABLES P.O. Box m QMGK 1., FMFMA". KV . MEMO" OF.I&COM + twuF W. MW rAMU ARE m DRAIMNG N wom AD-M-om SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-11-M FEEMW FOR WEli1C PI11F'06ES WT 001f mm = gm ADDENDUM OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE EUVATION (W/ OFFSET SECTION) SIMNG TIE -DOWN SPACINGS ~x FIGURE 11.0 S48 ran 4.0 F011 1611ms =-MR IDmD TYP. CROSS SECTIONS) SHOWING TIEDOWNS SEE WE5FE [rAaa oM Ao-lo-ooao ➢lZ.ti�9I AFPLIf A 1113E STANIARD M0.11-lJ� S"Ll W X WT -SOE WE % AO-10-MI If. R!OMI S151Fll--7 W"m A � _4 � r �— ANm ANME �sv-�l6 FIGURE 11.1 �- su I ae Imt fimff eTe 1>I -WIN s® TV. MOIMI AIM-4 R FIGURE 11.2 JU FOB 9310M U1401R1 I=11 I. SEE AD- M-M FOR SPACM TABLES (OFFSET SEC10 01L4 F 1 C •'• 2 SEE AD-AI-OOEO FOR OUANTY OF IOFKITUDIAL X-M M STRAPS REOURED. ���t` (OFFSET SECTION ONLY) o. 00454�k 3. SEE OTHER DETAILS FOR BLWM (PER) GUAN11TY AND 01M REOlARE OTS. C SEE AD-1D-M FOR ADDITIONAL REOUIREMQITS. idJr 09' 5. ZONE- 2/DFOSK V' 48' MAWN NIGHT ' g A, ZONE 2/EVOSIIRE V: 40• MAMM HEIGHT-36' FOR 12'-0' WDE UN15 �i�Cie ••. ZON 3/E> 'C': 4f MA)CIMMI HD(41T �� /�+� ' .. • ... • • r`�3• ZONE V. 40' MAWNM HEIGHT '►, �E,^, c► �1•� �� JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICI3 . ARM 7mm smaF1=o d AND WAVM M AM MAIFAIALS dACOBSFtI Y ACUM DRAW NC. SLdI MAI9RAI9 ARE PRGVM 10 1He RZww FOR 97ECF1C F11F'OSES AID IM BT DRAW IRPT aMiMMX AMD WE FFM QKR& JUNI t 2mk w I I V (/`/. a� Ei1Al NUFACTURED HOME �+ RUC110h1 AND SAFETY STANDARDS M.T. DAZE 6-8-04 REV.I.Enm FIG. 11.0, 11.1 & 11.2 A 1 1 11: 8;d 4 ADDENDUM ALTERNATE 'OFFSET -UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OfTSET SECTION) SHOWING TIE -DOWN SPACINGS FIGURE 12.0 SEE FIGURES 11.1 AND 11.2 FOR 1. SEE Pal TD-OOW FOR SPACING TABLES (OFFSET SECTION ONLY 2. SEE AD- M-0030 FOR OUMITY OF LONOTUDIAL TIE-DOAN STRAPS REQUIRED. (OFFSET SECTION ONLY I SEE OR R DETAILS FOR BLOCKING (PIER) QUANTITY AND DRIER FtEOUIMMENTS. 4. SEE AD M-0001 FOR ADDITIONAL REOUIROJENTS. -SECTION 1fe STE��-.rr DAPIA APPROVAL* No. •% A pp:".. 910334- CXI Or- STATE c, NSTROC"ICINANO SAFElY OTICErz . JACOBSEN HOMES TKX SKOFIC-ATNIONS A4 MAUMM DRAWN Or MC R.R. 5-9-01 'LETTER: ORIGAAL PROPRIETARY. AND OWERAPAL DRAWING TITLE: P.O. BOX 368 WERIALS OF JACOBS01 I&MUFAMAING FIG. 12.0 SAFETY HARBOR. FLORIDA 34695 W. Sjot MA*MALS ARE PINNOID TO THE wncmw raR VWK MPOSEAND IIA57 BE DI NUWBER: L 19, PHONE (727) 726-1138 19PT EMMIML AM SEMEIS RM OKM AD-TD-0082 55 ADDENDUM��R�S 108" HIGH SIDEWALL TIE —DOWN SPA ING TABLES i ZONE II & III/EXP. C & LONGIT INAL TIE —DOWN SPACING TABLE �rl NK WAND ZONE I WIND ZONE N FLOOR WL Orr. ma wL OTr. No= WIDTH END OF ANGLE Ell 00 IFMC E gril it 1BL B EA. sm" W. A O� 42' 3 53' 3 52 4 45' VERTICAL TIE —DOWN / FRAME TIE —DOWN I SPACING TABLE WN. MAI WIND ZONE I WIND ZONE II SPAM Lm MUR AWLE SPAM °�� MOM ANCUE WIDTH OVERHANG 26'-8' 6' 6'-8' 31501 40 =50' 5-4' 31501. 40' 5D' 30'-8' 6'1 6'-8' 1 31501 40 -50' 5-4' 31501 40'-50' oo LONGITUbINAL TIE —DOWN SPACING TABLE MIN. . WIND ZONE I WIND ZONE M OTTAMUR rSweEeMli AN(iE Nx otr. ETD ff ANm A FLOOR WIDTH � L � o k � gcnaN e a 26'-8' 4 41' 4 5T 4 51' 4 v VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MK MAI YNND ZK I WIND ZONE 0 SPA= LOAD MON MOE SPA= 1nA ANOM AWE FLOOR MOTH OVERHANG 26'-8' 6' 5-4' 31501 40'-50' 4'-0' 31501 40 =45' 30'-8' 6' 5'-4' 31501 40'-50' 4'-0' 31501 W-45- INNOZONE 11 (110 ,MPH) 20 PSF ROOF 10 PSF O.L REF. CALM EN IL• `i DAPIA APPROVAL•`� NOTES: )OT1a=1cq.,;'-•'y APPROVED BY 1. SEE RILL ADDIMM FOR ADDITIONAL REQUIRE I NTS r NET- 0045484 y Z SM AD-ID-OOD4 FOR MANUM PIER HOM REQUIRED FOR THE LOADS TIIBIA XD AB01E -rN 0 -43 • •.,, INC•� r-� p. �, , ��� +/ • .Oi1l�•''• ' :.. . FEDERAI. MANUFACTURED HOME CONSTRUL'TION AND SAFE f f SfANDARUS JUL JACOBSEN HOMES NOW& w*m �NATs Na mum= Nc DRAWN Br M.T. DATE 0�-20-04 REv. LEiIER DRAANC 111E 108' HIGH SIDEWALL SPAaNG TABLES P.O. Box 36I1 GOMK rRMWM. AM CMUNM "AMMS OF MOM YNNiACUM IOC WCH VAWAN3 NE FWi= A IFf SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-113D REfll M Fat 9'W Ill M NO W9 E Kff aWMnu NO SEnET nM OHM DRAIINC NUYBiTt AD—TD-0083 56 ADDENDUM SIDE ELEVATION TIE -DOWN SPACINGS PER Aa16-OOIO ME TYPICAL CROSS SECTION SHOWING TIEDOWNS TIE -DOWN SYSTEM TIP.111m ANm mu Tmm PEA A6-A}OOHH Tmff m a-14 m FIGURE 10.0 FIGURE 10.1 TIE. ANm mu Sr£ 1401s HTJR y wlotlEy HEIGHT VA DZONE M (110 MPH) 20 PSF ROOF 10 PSF D.H.. Oft, DAM APPIMM.' 1. sEF TD-0083 FOR SPACNG rA8U3 : �. GSA • '�� APPROVED BY 2. SEE M-M FOR 00AN ITY OF LOHGTUDUL Til IN STRAPS REQI1111M r �, . 1C 1 SEE 0 Ill FOR E�OCHWG (PER) OUAHTITY NO OTHER REOUItE)"M : a , 0 4. SE AODEE�l111 FOR AWTIMAL REOUIRENDHTIINF[IINC. 5. ZONE 2 lRE 'O•: 3r MAMMUN HEIOEIT ZOtE 21, V. Zr NA70MUN HEIGHT � "�� '. .C+. ? � ,�� ZOFE 3rb IRE V. 3r MAMM HEIGHT � C OR! . ' ' o ZGE 3' RE b•• 3r NA)DAIUN HEIGHT ���'�a�J,;'••••�•'' ��o, CONSTFEDER!_MANUFACTURETYSil c 6. All 1JOHS ARE BASFD ON 2P ROOF Al HWLE �� H►°� COMS1RlICTIONANOSRFE1YSf i{HU$ y •� ♦l JACOBSEN HOMES >" S%W=TM UNAHHHAHS AFC �" M.r. 0A1Ec 07-20-04 H1EY. !� PHHa Tw>� Auo MA" TIRE-d P.O. BOX 368 1/1°'� °F aj% ""'"JFAC1"� nGIJRES 10.0 AND 10.1 W. SIM WUH M ARE PAMW 10 11K SAFETY HARBOR. FLORIDA 34693 EMN FIR 9= FliF= AM MW K DRAIMNP• PHONE (727) 726-1138 Ea�T ommolm w Im Rm amm AD-1D-0084 'i ADDENDUM �aR 108" HIGH SIDEWALL TIE—DOWWN SPACING TABLES ZONE II & IIIf EXP.. C & D �� 0 LONGITUDINAL TIE —DOWN• SPACING TABLE e (+' MIN. WINO tOfE 1 BIND ZONE II V FLOOR • lK alr Mod lay. on mm WIDTH Ert Ew Cr m EA 00 CF MOLE O��� 0L SiT:ildl Imt / EA sECnol � I VERTICAL TIE —DOWN FRAME - TIE—DOYN SPACING. TABLE MIX MAX - WIND ZK 1 WIND ZONE I FLOOR ltIIDIHH EAVE OVERHANG m mom ANO:E SPAOIG L� Moot ARQE 73'-4' 69. C-8' 31501 49' 5-4' 3150 45' 14'-0' 1 6' S-8' . 3150 49' 1 5'=4' 3150 45' o LONGITUDINAL TIE -DOWN SPACING TABLE MN. W ND ZONE I VID ZONE III FLOOR MIL DTr. mm mx on moo N�OiH EA DID Cr AM EA Do a ANOIE EA SECBON MN. I EA. SEC 0 VX 0 13'-4' 3 48' 4 43' 24'—O' 3 50' 4 45' VERTICAL TIE —DOWN / FRAME TIE—DOYN SPACING TABLE W?L MA)< WIND ZONE I WWD ZONE III VAOTHH OVERHANG SPA= Loa m+m mu VAM AMM ANGLE LIN 23'-4' S. 5'-4' 31 4T 4'-0• 31m 43' 24'-0' 6' 5-4' 31501 4T 4'-0• 31501 4T 108• MAX 9DEWALL HEIGHT M OZONE 11/111 (110 MPH), 20 PSF ROOF 10 PSF D-L REF. CALL& ' ,`1�ZSiff!lf�ej NOTES, • �r �9j :�f WA APPROVAL: APPROVED BY 1. SEE LULL ADDENDUM FOR AODIRONAL REOU6tE1K1(ii �O•• : G�li �� • ,i owoDecNNC i. SEE AD-M-M FOR MANN PIER HEKM REQUIRED FOR THE Lo ti �'• {''i +� M . 13,2006 TABUTAIED ABOVE s '� ` I. i G FED auu rauc o xorE �VyF1TE C/ :, O E;1�: �� •,�V 4„�� wNsrr wro sSAFETYsraND wOs ` JACOBSEN HOMES »�sEVWRu�:M AN B>: R.R. °AL 11-28-06 `O"ET'E" r.a Box 7sa - UUMAL IR6rRIAAA4 AND UNWw"WL WOWS OF MOOM MA?WACPjaC 1u7EC SM IAMAS me PPKMM TO Tnc ORA►WC 111LE 108' WCH SDEWALL SPAgNG TA8if5 SAFETY NA (%, FLORIDA 34695 PNo►u: (�n) 729-naa M fd=W IM 3M 1O RMP= ANDDRANKT K PVT camm�uL Am mm rna moos DRAMNUMBER: AO-M-0085 58 TYPICAL SIDE ELEMON . SHOWING DE —DOWN SPACINGS. . ADDENDUM TIE -DOWN SYSTEM FIGURE 10.0 a TYPICAL CROSS SECTION TIP. SHOWING MEOOWNS nHxR sIs>ER� � 1r aHoss �am � AR010! AIidE fA A4PROIED STABIQER � 1 . SET ANl = HEAD IRSiNEED vimANOa1 SRAFT.IQICAL UOINCHE 1/1111 f N its 5aE (110 MPH) - (�.I FIGURE 10.1 20 PSF ROOF 10 PSF D.L REF. CALM 'tts16: N1 l y S"i E ��i1ld CARA APPIWAU `• �.....C� t• II 1. SEE AD -TIT—= FOR SPAM TABLES �` �O: `Tiff ,��;..•�+'� ��, APPROVED BY SEE AD-M-M FOR GUANITY OF UNITidAL K-00116 STRAPS REQUIRED.00 3 SEE OTHER DETAiS FOR BLOW6 (PER) QUANTITY AND OTHER BEGAttMUTS. ' 0. �dj ON 4. SEE FULL AODDIDUU FOR ADDIDDNAL 11 9JAVEATS ; Dec 13,2005 1 ZX 2/10FOSUK •'C: 4C M2/WOK1A1 HEIGHT . ZONE 2/W'Ir.2r. MA1011 N HEW kr/ • 1 Y� PIN } C. ZONE 3/ETD nK T. 41' 41ATt W REVIT S •A .- FEDEN OAINfAL11i1Eo 1a� ZONE o/bwRE V: SU3r MAMW HOW•., /h w; ' l` ; caataucrnN Ara s+welr STANDARDS6. ALL 9?ECFKATR6 ARE 6L B ON 217 ROW ANGLE MAX AND 106' MAX •' �` /yy4• 90EWALL NAIL II IiOTEC AAit 9R%�. t DAY. RE1L IE n JACOBSEN HOMES ws Rumm me R.R. 11-28-06 MOL P10"EiMtt: 00 CafW"AL MAAIIC BAT: P.O.0,10013 box 36e MAmnks cF JACo M IWAiALRIIMIC uC 20 FROM TYRE FROIA 1fE FIGURES KID AND 1 ,1 SAFETY HARBOR. FLORMA 34693 NZPkW RN VWM Hw92.1 NO Ili K aw—K mmriIAIIR)ER PHONE (727) 726-1135 mul mriaonr. no SEW FINN cbm AO—M-00B6 19 ADDENDUM (108 PIDEWALLP) g & v% NOR AL TIEE 1I-DOWN & IN OP dm &TDABLES � z,ikz c1 O�V v LONGITUDINAL TIE —DOWN SPACING TABLE ►SIN' FLOOR $DIN Z No zaNE m U Ov or Ell SECn* 1ii� a Eel do OF Eel SEC • y1� 9 12`-0` 2 53' 3 13 -4` 3 37' 3 46• 3 45' 4 40' VERTICAL TIE —DOWN / FRAME TIE— DOWN PPACINO TABLE *FLOOR j�L VAX. OVERHANG JAD ZONE tl 00 ZONE II SPA* VAX goo Alpf • SPA* VAT 'NOR i�' 12'-0' Ir EACH SIDE 5'-4' 720 35' TO 47 S-4' - 38' 45. IS-4' a EACH SIDE 1 5'-4' 80` 35' TO 40' S'-4' 42' 45 154 6` EACH ME I T-4' I w 40' 54 46' 4S' � � O�V LOWITUD1NAL TIE— DOWN 9PAGING TABLE �N, FLOOR,� #D ZONE li IONE In EL om OF Ell SECTON AI�EY �li(, g EA ThD OF EA. SECOON • kw g 12'-0' 3 44' 4 40' 13'-4' 3 52' 4 45' 15'-4` 4 44' 4 56' VHRTIGAL TIE -DOWN / FRAME TIE —DOWN OPACINO TABLE FLOOR *OM VAS EAVE OVERHANG 0 ZONE 1 IONf 11 SPA* vix m AhX, SPA* �IPER *10 A4Wt 12'-0" 6 EACH SUE 4'-0' 72` 37, 4�-0' 34• 40' TO #5' 13'-4' 1 6 EACH SIDE 4'-0' 72` 40' 4'-0' 3e 40' TO 45' 154 6" EACH SIDE 4'-0' 80' 40' 4'-0' 42' 47 10 45' • NOTE: IHHEN ANCHOR ANGLE FROM VERTICAL CANNOT BE ckcx, ACHIEVED, ADD APPROVED STABILIZER PLATE. SEE NOTE y5 FOR HOWES SET IN FLORIDA ��°j" "•fa �: 1. SEI TU.L ADDEtON FOR AWTIONAL REWR RENTS, 2. TABLE BASED 011 A1yCHGR 1p LOAD OF 3,1501 Alp DIAG01{k nE TO OPP09TF BEAp1-'• VAX FAyE OyER1UUIC REiERS TO 0}A3♦111U((, AT SOE*ALL NOT iRdiT OR IRMEAAR 4, TABLES APPLY TO 144' 16O', AND 184' FLOOR to �IN 95 1/2' J_BE SPACK 1� I AMML V ;ALL HOWT AFp 6' WIN SCE OVERNANO (6' oyE *MC VAX EACH S DE OF 0011 5. STABLua PLATE'S ARE REOWREO ON SDE*AU ANCHORS ANO LONOTWINk AMMOM SET IN nMA. SEE OILY ME 15C, EFFECTIVE VARM 29. 1999 EN A; C,L1 •'� �+�°i �(�' :, �;:��4''•. C:� a e;, •, '- -{ OIP1A APPROVALNO APPROVED BY Mar 25 , 2008 N INC. cEDERAL raRUGAQIIRED NO.E COMSfRUCilON nno SAFETY STANDARDS "' :+_'�.: :�= • 'y y •o'St`'•'••:; I r pw`Q' oI `6'� •••••• - ` i JACOWEN HOMED ® P.O. Box 356 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 Nond� K%SKCF000{S0DOpAjlilrSAA[ '�AN�A4�c yq� 4R[ r4i 0M . ME o*m SR t 0.�1.T. DATE: 12-11-07 REy. LETTER DRAW; nnF NORM SPACING TABLES DR G AD- TO-0087 bu THE TO ADDENDUM SHEARWALL TIE-DOWN/PIER REQUIREMENTS ur. !vv umm ff.*VMom �� Tim PER SHEA"ALLS (AIL STUAftM cc_.Dartfs awn VE Nam t sit NOTE t v %a MOTES 2 mo 3. Q ►lot REdD Tws tDC�1ilON ur s/w tit amowlt Rnr «a>R.s m re 3HEWhMALL5 (ALL OtUAWQ W-crows rEo om v� Nox 1 SM NOTE IA'— QSM MOTES 2 AND I A ins ILoaIoT oN >Hs LOGATiat to Rmb TMs t �T off FIGURE 8, 0 FIGURE 8.1 'AIL ABOVE IS SHOWN WITH A TWO PIER SHEARWALL CONFlGURAnON, HOWEWRr THIS DETAIL APPLIES SHEARWALL CONFIGURATIONS, ALL ZONES. -AND ALL 'LF VALUES. Z 1, llE WPM PmT[-wo SIw ur or LoaTo ut �• iTIIER K A" Vaal AM OAT Rmcatm AT eo OR I AN01M VJ EE RATED aX AN t�MAT( U W (MW tl9fll LOAD] • r •�• •� r �`� •��� (SL R— W [To-W1CRAL MOTES] R12 RM Qr GkOM +NCM Pmx" m) 1F ��y\�a1� C4 • �� �� L A M AT CADI DID rF ME 20MML J]lst9 rot Tro' Wort OCTA�L1� Q` 1 `0. Em AT CAN 00 w jasts REeAle> M or � ovr, sTww IRa�rrts) 910334 1 x 10 Is LCCATED A K K A W KAM M I WIT OvS-Wa M Ito BE- 3PWS OR MKI AW R(aX a (ALL X"WkL WfKMr M ALL Wfs A10 I Ewgms} : -o :. SrATe C AV PROVED BY TE8 10 2000 .P11INC kL MANUFACTUREO HOME RUCTION AND SAFETY STIUNDAROS DAM Xk JACOBSEN HOMES w,mwto u�Nq°� •,•••''�.R. 02-01-00 chaffmama_ rf F 4#ss=3 Arm .. RE {� P.Q. tto% lea rATa4alc cf itiovew Br ig S/W TIE/PIER REO. tvS WETT NARGAK FLORIOA 31e63 M 64G1 KIW C PHONE (r27) 72o-TE38 ox XtgAV &mt 11 N f m *19 ORA+�+G riA(6�7r: AD-TT)-100 61 ADDENDUM DOUBLE SHEARWALL CONFIGURATION SINGLE -SECTION TIE -DOWNS / SLING MAY BE FLAT OR SLOPED SIDE VIEW 1 1/4 X .035' TIE -DOWN STRAP CONTINUOUS ARCW JOISTS. END VIEW 350 PLF MAXIAUM SHEARWALL DES'GY VALUE (PER WALL) 1 1/4' X .035' rM ,^,OWN STRAP CONTINUCJS ARCJND JOISTS. NOTES: 7.1711( E 0VAL �. DAPIA APPROVAL 1. 01mm A-404ORS 10 BE RATED FOR AN ULTIMATE LOAD OF 4725F 13150 DESIGII LOAD] (SEE AD-M-O:DI'(7D-GEROM NOTES] FOR NOTES ON 1ROUND ANCHOR ASTALLAnOtI.) '?I '. =_ �9 0 `.'kPPR y CD 13Y'( L INSTALL A PER AT EACH END OF THE 9WWALL JOFSTS (PER WE ABOTE DETAILS). � % :1• J. MEN SI- ARwRJ. IS LOCATED ABOVE A SMID IEAOER (RILL Koff CROSS-YD19fP.) NOON TE-W-4 STRAPS. OR PIERS ARE FWAIED (ALL SHEARWALL CONFICUTATIM ALL ZONES � AND ALL DFO.RM). 4. TIE-DOY+N STRAP '�i �. i REOUBIED AT EACH END OF JOISTS, ALL OB CONFIOJRAnoNs. ' ��; \\,��� I `� �• 5. CEILNl S`fOWVV FLAT -OPT, CATHEDRAL OR SLOPED CEAJNC MAY BE USED. ��i rr , 6. FULL WITH SHEARWALSS ARE SHOWN IN TIE DETAE •ABOVE, HOWEVER, ANY LENGTH OR CONFTCURATION SHEARWALL MAY BE USED. JIIIIIIIIli NOTICE: DRAWN BY: I DATE: REV.; LETTER: 5p1qrF JACOBSEN HOMES -nIESE SPEa11CATIONS AND DRAWNOS ARE R.R 2-6-9601'"O NAJ, PRCPRCTAQT, RAO CUWWENnAL DRAVANG TITLE: P.O. BOX 368 HAIER.A15 CF JACDBSEN UANU:ACTUR:\c TW DBL. S W CONFIG. 11E—DOWN SAFETY HARBOR, FLORIDA 34695 FfOP011 IDN R_. PR S &ND "I EE G NUIJECR: PHONE (813) 726-1138 KEPT EANRD ak PM MET nKW DINERS. GRAN'\, AD—TD-0110 62 CEILING MAY BE FLAT OR DOUBLE SHEARWALL CONFIGURATION TRIPLE & MULTI SECTIONS SIDE VIEW SIDE VIEW (MARRIAGE WALL APPLICATION) (SIDEWALL APPLICATION) 350 PLF MAXIMUM SHEARWALL DESIGN VALUE (PER WALL) 1 1/4- X .035- TIE -DOWN STRAP CONTINUOUS AROUND JOISTS. TO 35, CHILIAD ANDHORS 70 BE RATED FOR AN ULTIMATE LOAD OF 47251 (3150 DESIGN LOAD) (SEE AD-TD-D001 (IIF-GTNERAL NOTES) FOR NOTES ON GROUND ANCHOR INSTALLATION.) INSTALL A PER AT EACH END OF THE SHEARWALL JOISTS (PER THE ABOVE DETAILS). WHEN WARWALL IS LOCATED ABOVE A SOLID HEADER (FULL HEIGHT CROSS -MEMBER) NO C TIE-DOMN STRAPS OR PIERS ARE REOLARED (ALL SHEARWALL CONFIGURATIONS. ALL ZONES AND ALL E)POSLKS). TIE-OOM STRAP REQUIRED AT EACH END OF JOISTS, ALL DBL S/W CONFIGURATIONS CEILING SHOWN CATHEDRAL OR. SLOPED. FLAT CEILING MAY BE USED. FULL WIDTH SHEARWALLS ARE SHOWN IN THE DETAIL ABOVE, HOWEVER. ANY LENGTH OR CONFIQAATION SHEARWALL MAY BE USED. TIES DETA.L MAY APPLY TO TRIPLE AND/OR DOUBLE WIDE SECTIONS. 350 PLF MAXIMUM SHEARWALL DESIGN VALUE (PER WALL) 1 1/4- X .035- TIE-DOM STRAP CONTINUOUS AROUND JOISTS. John C. Doe&6, P.I 15133 C. R. 22 Goshen, IN 46526 IN IS A TRIPLE WIDE RAFTER, APPLICABLE TO STANDARD ILE WIDE TRUSSES. 4D VIEW x .03Y TIE -DOWN STRAP JOUS AROUND JOISTS. NOTE: ALSO APPLICABLE TO 'SLIP SIDE' MARRIAGE WALLS WHEN AT LEAST 2 STANDARD VERTICAL 71ES ARE INSTALLED, (1 EACH SIDE ADJACENT TO SHEARWALL LOCATION) APPROVE® BY i ON1 = nQw% mKsw.. % JACOBSEN HOMES THHESE SPECFIGTIOHS LTmsAND DRAWN BY: R.R. DALE: 4-09-96 REV. LETTER: eox 36B AND oRAWvns A✓£ OMONAL. PROPRIETARY, AND C0101 N0MTm . MATERIALS OF JACOBSEN MAAIFACAIRINc DRAWING $/W CONfIG. TIE A P.o. HNG SJOH UAMMU ARE PRONOTD TO THE —DOWN SAFETY HARBOR, FLORIDA 34695 REOMI FOR SKCrC RMOMS AND IMT BE DRAWING NUMBER: PHONE (813) 726-1138 RAPT ODWI DIR& AD SECRET nWW OTItiRS AD—TD-10111 PORCH ANCHORING DOUBLE HEADED 3,1' NOTES: 1. SEE SET-UP MANUAL AND ADDENDUM FOR APPUCABLE BLOMNG X .035" TIE -DOWN STRAP IOUS AROUND STRAP 13LOCKS. BMNDZONE IA EXPOSURE C �t.° %''•'.l 'ice:.r� (110 MPH) 20 PSF ROOF 10 PSF D.L. �a "' G ivA - 109,491 - 7 `APRQVAIr; OAPIA APPROVAL, I.; PPROVED .BY RAL MANUFACTURED HOME NSTRUCTION ANDSAFETY STANDARDS Wrc i •a ma NOTICE. DRAWN BY: DATE RED LEM: Ql=JACOBSEN HOMES mmsKcm1m-om ARE I.T. 12-13-03 OR OVAL PKPWTM. Ano.oaiDEYnA1 DRAWNG nTtF` PORCH ANCHORING OF JAMSEN YAMFAMURHG "I, P.O. BOX 368 NG SI01 YATERA1S ARE PRMWO TO DIE SAFETY HARBOR. FLORIDA 3095 KOPM FOR sPEOF1C PII6M NO VAT BE DRAWING NUMBER: PHONE (727) 726-1138 an CMDD M1 AM 47fT "M awes AD—TD-0112 64 ADDENDUM ALTERNATE VERTICAL TIE -DOWN APPLICATION APPROVED VERTICAL TIE —DOWN ANCHOR BRACKET (FACTORY INSTALLED) . FLOOR CRIMP SEAL (3150/ WORKING LOAD) LTS con O x X 6 10 ' r4r�' VERTICAL TIE —DOWN TYPE 1. FINISH B. W GRADE 1 STEEL STRAPPING l A 1 1/4' WIDE h 0.035' O /F IN THICKNESS. CERTIFIED BY Li A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS DIAGONAL FRAME TIE CONFORMING WITH ASTM STANDARD 0 SPECIFICATION D3953-91. 0 STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. RAdUS CLIP I �I I I-1 11-I I I I —III- RADIUS CUP MUST BE INSTALLED ON ALL TIE -DOWN ANCHOR BRACKETS. (ERADIUS CUP ANCHORING EQUIPMENT —III III —III -I I BY SPLAACING AOSTRAIGH 3FANCATE'LENGTHTH OF CAPABLE OF RESISTING -III-I I I —III— 1.1/4' X O.OW TIE -DOWN STRAP THE WORKING LOAD MATERIAL IN ANCHOR SLOT AND BENDING REQUIRED ON THE TO FORM THE CONFIGURATION SHOWN.) TIE -DOWN SPACING TABLES (SEE OTHER III —III—I RADIUS CUP MUST BE INSTALLED TO PROTECT DETAILS FOR TABLES) I- III —III — THE NE -DOWN STRAP FROM THE BRACKET EDGES. SEE OTHER DETAILS III II I II ; .III I I INSTALL N THE BRACKET 'Q S�THROUGH A US CUP. FOR ANCHOR ANGLE. ALL VERTICAL TIE -DOWN STRAPS. DIAGONAL FRAME TIE -DOWN STRAPS AND ANCHORING EQUIPMENT SUPPL BY AND INSTALLED BY OTHERS- ON SITE. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ATION. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). 01111IIIIIfi/l,Jr 1 '*'(a0YANo. 'Q . • ENE87035 /O • E \\ ANCHOR IIiRAGIcti "" `7I&- M DEVICES ARE CERTiED BY OTHERS DAPIA APPROVAL• OVED BY lJUN 1 5 INC. N077CD DRAWN BY: DAIS HLY LLIIM JACOBSEN HOMES MSE VEC11101mm AND DRAMNIS ARE C.L.Y. 5-31-95 MOOM. PROPKTARY. AND COrtl mR#`L 0RAIMNG MILE: P.O. BOX 368 IIATMAIS a JACO + UNOAC1URD16 ALT. TIE -DOWN APPL. OVMED TO THE A SAFETY HARBOR. FLORIDA 34695 REEcpiDaa lat sp[[a �S NO 1451 BE DRAWNG NUUBM PHONE (813) 726-1138 W7 CXWnk AN) 31CRrI rROY Dntns AD-TD-0200 65 ADDENDUM ALTERNATE VERTICAL TIE -DOWN APPLICATION APPROVED VERTICAL TIE=DOWN ANCHOR STRAP (FACTORY INSTALLED) FLOOR IF FACTORY INSTALLED STRAP IS NOT LONG ENOUGH, 11 YAY BE LENGTHENED BY USING A CRMP SEAL WITH A WORKING LOAD OF 3150 POUNDS to in "0', t �J c^ DIAGONAL FRAME TIE I' ANCHORING EQUIPMENT CAPABLE OF RESISTING -I THE WORKING LOAD REQUIRED ON THE TIE -DOWN SPACING _ TABLES (SEE OTHER I DETAILS FOR TABLES) SEE OTHER DETAILS FOR ANCHOR ANGLE. NOTES: 1. ANY ADDITIONAL VERTICAL TIE -DOWN STRAPS, DIAGONAL FRAME TIE -DOWN STRAPS AND ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). IF NEEDED. USE VERTICAL TIE -DOWN TYPE 1, FINISH B. GRADE 1 STEEL STRAPPING 1 1/4- WADE k 0.035- IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91• STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL AND SEALS. T 910334 -_ - STATE \� N Alm i� laJ, S it a S J H W W 0 W h DAPIA APPROVAL APPROVED BY REVISED N14INC. MEERA wN:sACTURED HOW CJDR. rJCm+ ANDIWET!REANDAROF NOnCE DRANN�Y: DATE REV. LETTER: LE///T��� ® JACOBSEN HOMES THESE SPEOITUTIOHS AND DRAvdVGS ARE ORIONAL PROPRIETARY, AND COu11DDInk R.R. R. 10-05-96 DRAMING TITLE: P.O. BOX 368 uATEMALS CF' CDBSEN MAIWFACBRENC ALT. TIE -DOWN APPL. SAFETY HARBOR, FLORIDA 34695 DC. SUCH MAIERIA,S ARE FRONDED TO THE REOT4NT FOR SPEOM PJMM AND NMI BE DRAWING NUMBER PHONE (813) 726-1135 IVY M IDDIRAL NO SEW FROM 07MM AD-TD-0210 66 ADDENDUM COLUMN TIE -DOWN APPLICATION FLOOR ANCHORING EOUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 3150 / MIN. O ANGLE SHOWN. 35 ANGLE El I Ml 11- ANCHORS INSTALLED 24- APART COLUMN STRAPS SEPERATE GROUND MARRIAGE LINE OF MULTI -MADE FLOOR ATTACHED ANCHORS u ..11nllllil . VERTICAL TIE -DOWN TYPE 1. FINISH B. GRADE 1 STEEL STRAPPING 1 1/4- WADE & 0.035- IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91.' STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. 3Y ANGLE TO TWO (3150# EA.) NOTES rwravL/� �4 uAnA ArrNUVAI 1. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. %STf9�c*FI : Q' N0. O ; y AFr �'EfJ BYE ENC8703571 �� 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING _ : S •-ram'- SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- •�19 * 1 5 AT10N.NI •'• ,cj 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REOUIRES THE USE �•;� �. �� �`'• ��� �.``,�,�� INC OF EXTERNAL STRAPS OR CABLES. Cl '�.,Ff O1�' •'y��,,,`� t04irKi101AlOiV[11{LrDle4 JACOBSEN HOMES THEN SKQrXAT* MAW01 BY. ' C.L.Y. DACE: 5-31-95 REV. LFrIER P.O. BOX 368 AM AM PMPWMY. AND OWUNTNL 7BVa OF JAC0MANLFACIURNG 85E1i n DRAWING TITLE COLT1E-DOWN APPL. OppMACMWW. SAFETY HARBOR, FLORIDA U695 We SM NAWRLALS Aid PROVM To THE Ptcooar Fa 9Ff11C PJMM AD N= K . /H` DRAWING NUMBM PHONE (613) 726-1138 PC" owwrAL uo ZOO mom onm AD-TD-0251 69 ADDENDUM COLUMN TIE -DOWN APPLICATION ANCHORING EQUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 3150 / MIN. COLUMN STRAPS SINGLE GROUND 1. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS— ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR— ATION. 3. !I PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REOUIRES THE USE OF EXTERNAL STRAPS OR CABLES. MARRIAGE LINE OF MULTI -AIDE FLOOR VERTICAL ME —DOWN TYPE 1. 'FINISH B. GRADE 1 STEEL STRAPPING 1 1/4' WIDE h 0.035' IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION 03953-91, STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. ATTACHED TO A ANCHOR (3150#) GISTE No. RFo s PROVED BYE NE87 JUN 1 5 10 INC �� � �\��.��� A►osARTW NOTICE 'URAM+ BY: DATE: REV. LETTER: JACOBSEN HOMES nm SFE0/1cAms AND WAVM ARE C.L.Y. 5-25-95 . 01MAL PRCPWA". AND CONrUNnAL DRANWG TITLE: RIAIS OF JWOM WNUFACi 84 P.O.P.O.80X 368 WiM SM MAIERPLS ARE PROMO TOM COL TIE -DOWN APPL. SAFETY HARBOR. FLORIDA 34695 REOPOrr FOR SKCM REPOSES MO VIM GE DRAWLING NUMBER PHONE (E13) 726-1138 WT CDI WPAl NO SEOQT rRW OHM AD—TD-0252 no ADDENDUM COLUMN TIE -DOWN APPLICATION FLOOR ANCHORING EQUIPMENT CAPABLE OF RESISTWG THE WORKING LOAD OF 4000 / MIN. COLUMN STRAPS SINGLE GROUND NOTES- 1. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERFOR ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES. 0 MARRIAGE LINE OF MULTI -WIDE FLOOR VERTICAL TIE -DOWN TYPE 1, FINISH B. GRADE 1 STEEL STRAPPING 1 1/4' WIDE & 0.035' IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL. AND SEALS. ATTACHED TO A ANCHOR (4000#) ..untnu.. �r�G\STEy�UF No. A I A I PROVED BYE, jM 1 5 r V l f"11NC. aww rw�vr.'nr� lay[ caanucta� No sMnr twouof JACOBSEN HOMES 1HM SPE�7CAINOTIIONS uo DRAVINGS NIE,I FD1Nw+er C.L.Y. uATE 5-25-95 REv.1FTTm m a . ICILKA FRaF'WARX ANDcaemmuol DRANWG MILE.- P.O. Box 366 MAIM45 OF JACOBSEN WffAC1UiWc TO DIE COL. TIE —DOWN APPL. SAFETY HARBOR. FLORIDA 34695 SAEOpea IG RICHMUMVECnC PINKS AND UM K LS ��� PHONE (813) 726-1138 CGIiw%q uo mm nmm Gna6 DRAWING NUMBER AD-TO-0253 70 ADDENDUM 18411 WIDE COLUMN TIE -DOWN APPLICATION 1 COLUIW 'A' - - - - COLUMN 7i' ISEE TABLE FOR MAlOMA1N SPAN FOR COLUMNS 'A' OR r COLUMN 'C' COLUMN b' TABLE FOR MAxtNUN SPAN FOR COLUMNS 'C oR b' _ I APPROVED BY SEE TABLE FOR SPAN COL 'E' SEE TABLE FOR Ma SPAN FOR COL ' INC. FED L MANUFACTURED HOLIE RUCiIONAND SAFETY STANDAR03 11 R 0 3 1999 COLUMN 'E' 11 COLUMN Y COLUMN V. ISEE TABLE FOR MAXIMUM SPAN FOR COLUMN J MAXIMUM ALLOWABLE SPAN TYPE ( ANCHOM REQb AD-TD-0251, COLUMNS 'A', 'C, b' OR I' COLUMNS 'B' OR 'C Cam r AND ZONE 2 ZONE 3 ZONE 2 ZONE 3 ZONE 2 ZONE 3 AD-0252 SEE NOTE 1 EXP. 'C EXP. b' EXP. 1C' W. b' EXP. 'C OP. b' EXP. C' OW. b' OP. 'C EXP. b' EW. 'Cr DP. b' 2 31501 ANCHORS Ii 31-4' 25'-6' 29'-4' 20'-4' 37'-4' 25'fi' 29'-4' 20'-4' 37'-4' 25'-6' 29'-4' 20'-4' 1 31501 ANCHOR I" 12'-10' 14'-T 10'-Y 18'-6' 12'-10' 14'-7' 10'-Y 18'-6' 12'-10' 14'-7' 1 T 4000/ ANCHOR 2S-8' 16'-4' 18'-T IS-0' 23'-8' 16'-4' 18'-7' IS-0' 2S-8' 16'-4' 18'-7 13'-0' im �A AD-7D-0251, AD-TD-0252 AND AD-TD-0253 SPECIFIC INFO. ON ANCHORS. AD-TD-0001 FOR ADDITIONAL NOTES ON ANCHOR ALLATION. CAP•• G�STERF ' •`� N0. o� .Q 910334 :•• STATE OF A APPROYAL:ap 0 3 -WSU APPROVED BY NOTICE Afy M.T. DA11: 2-9-99 REV. LETTER ■ JACOBSEN HOMES TNESE sKaF1CA1mN4 AND omwm #x — CROW.. PM MUARY. M CorIMIK ORAwm lm: P.O. BOX 368 MA1EwaS OF J1AMRN OM YFACNC 184" WIDE COL. TIE —DOWN APPL M 9JM wAmaHS ARE PRONGED M w[ SAFEW HARBOR,0613695 0°" OORAwwHUMN PHOEE 7726-1a WPT on TWI nM AD—TO-0254 71 ADDENDUM TYPICAL SINGLE WIDE TIE -DOWN PLACEMENT SEE NOTE 2 A B C 24' LARGE OPENING 24' SEE NOTE 1 JIn•urrw 1Ln 11b+1L MIL—Wnn JnV1rJ ", MUlldl BRACKETS (SEE TIE -DOWN SPACING TABLES -NORMAL AND/OR ALTERNATE- FOR MAXIMUM SPACING ALLOWED). ALSO SEE NOTE 3. STANDARD VERTICAL TIE -DOWN STRAPS OR ANCHOR BRACKETS TO BE INSTALLED A MAXIMUM OF 2'-0* (241 FROM EACH END OF THE UNIT. NOTES: I. LARGE OPENNG = ANY OPENING WIDER THAN MAX TIE -DOWN SPACING ALLOWED.E 2. VERTICAL TIE -DOWNS MAY EXCEED THE STANDARD VERTICAL TIE -DOWN SPAOR - SO LONG AS, THE AVERAGE SPACING [ (A+B+C) / 3 ] DOES NOT EXCEED THE MAXIMUM TIE -DOWN SPACING REOUIRED ON THE APPROPRIATE VERTICAL/FRAME TIE -DOWN SPACING TABLES (SEE OTHER DETAILS). 3. INSTALL FRAME TIES AT ALL VERTICAL TIE -DOWN LOCATIONS. 4. SEE AD-TD-0001 FOR ADDITIONAL REWIREMENTS. JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR. FLORIDA 34695 PHONE (013) 726-1138 ,`���Tuuuull •: �,V 5 T E.o ENE8703571 ONALTTT�r�`� ANCHOR BRACKET AND TIE -DOWN DEVICES ARE CER11rED BY OTHERS NO77CE 1 DRAWN BY: THESE SPEOTICAMM AND DRAWCS ARE MaNAL. PROPRIETARY. AND MWIMITTA YATD;9AL5 OF JACOM MAMXACI"G NG WCH MAXAMS ARE PRONGED TO TIE RECPINT rOR 9Efi1C PJMM NO INST K KEPT COrfM AL MO RM TROT D1IE M ROVED BYAlt- M1 1.5 sm �...::.:..��� INC ,:�..: •r va v: m ItMONR C.L.Y. 5-31-95 TYP. SINGLE WIDE T/D AD-TD-0300 72 ADDENDUM TYPICAL MULTI- WIDE TIE -DOWN. PLACEMENT SEE NOTE 2 A B C 24' LARGE OPENING 24' .SEE NOTE COL.UM N SUPPORT ME —DOWN STRAPS REQUIRED AT .COLUMN LOCATIONS ON EACH SIDE OF OPENINGS GREATER THAN 49' IN WIDTH. MULII—WIDE FLOOR SHOWN SET'ERATED FOR aARITY V V V V V V v V 24' 24• STMDARD VERTICAL. TIE -DOWN STRAPS OR ANCHOR BRACKETS (SEE TE-DOWM SPACING TABLES -NORMAL AND/OR ALTERNATE- FOR MAXAAiIM SPACING ALLOWED). ALSO SEE NOTE 3. STANDARD VERTICAL TIE -DOWN STRAPS OR ANDIOR BRACKETS TO BE INSTALLED A MAXIMUM OF 2'-0' (241 FROM EACH END OF nE UNIT. FOR TRIPLE WIDE AND LARGER UNIT DESIGNS. INSTALL ALL TIE —DOWN STRAPS AS SHOWN IN THIS DETAIL 1. LARGE OPENING = ANY OPENING WIDER THAN MAX TIE —DOWN SPACING ALLOWED. 2. VERTICAL TIE —DOWNS MAY EXCEED THE STANDARD VERTICAL TIE —DOWN SPACING; SO LONG 4 THE AVERAGE SPACING [ (A+B+C) / 3 ] DOES NOT EXCEED THE MAXIMUM TIE —DOWN SPACING REQUIRED ON THE APPROPRIATE VERTICAL/FRAME TIE —DOWN SPACING TABLES (SEE OTHER DETAILS). 3. INSTALL FRAME TIES AT ALL VERTICAL TIE -DOWN LOCATIONS. 4. SEE AD-TD-0001 FOR ADDITIONAL REOUIREMENTS. IENE8703571 STA jqr�, qOF FJ; 6 fAN ''%s��NAI �N•�`�� BY ci 5 T995 DEVICES ARE CERTIFIED BY OTHERS JACOBSEN HOMES NOTICE.` DRAWN orDATE REV. LETTER: nas� sr�onc�ix>Ns AND oeAwNcs ME C.L.Y. 6-1-95 CRONAL PROPWMY, AND COWMIK DRAWING mi1: ARE PR%M TO 7HE /� P.O. BOX 368 UVEMAU CF JACO 1 UM FAM&W TV. MULTI —WIDE T/D /-1 IN SAFETY HARBOR. FLORIDA 34695 a"aPcx91°'r F(9 9 AM W51 K DRAWING NuuBM PHONE.(813) 726-1138 out CdimnoL me wou n= 011E1E AD—TD-0310 ZONE I TIE -DOWNS MARRIAGE WALL I OPENING TIE -DOWN (REQUIRED AT OPENINGS 1 ONLY. OPTIONAL AT SEE DETAIL - 'A' OTHER LOCATIONS.) FRAME TIE -DOWN SEE DETAIL - V SINGLE WIDE TIE —DOWN DOUBLE WIDE TIE —DOWN NOTE` C SECTION MARRIAGE WALL NOTE: SIMILAR To 1 OPENING IE-DOWN I A & B SECTIONS SINGLE WIDE SIMILAR TO DOUBLE (REQUIRED AT OPENINGS WIDE TIE -DOWN FRAME TIE -DOWN ONLY. OPTIONAL AT OTHER LOCATIONS.) .. PULL DOWN TIGHT TO --/ GROUND ANCHOR DETAIL 'A' TRIPLE WIDE TIE —DOWN BUCKLE WITH 2O251 IY MINIMUM SEE DETAIL - 'A' SEE DETAIL - V TIE -DOWN STRAP SINGLE HEADED GROUND. ANCHOR (WHEN MARRIAGE WALL TIES AND FRAME TIES ARE LOCATED AND SECURED TO THE SAME GROUND ANCHOR, A DOUBLE HEADED GROUND ANCHOR MUST BE USED) ALL GROUND ANCHORS MUST BE LISTED TO CARRY THE LOADING IMPOSED BY THE TIE -DOWN STRAPPING (3 i5o LBS. MAXIMUM FOR EACH TIE -DOWN STRAP CONNECTED). DETAIL 'B' TYPICAL TIE -DOWN STRAP (1 1/4' X .D35' MINIMUM 2INK COATED STEEL STRAP, OR EQUAL WITH 31so* CAPACITY MINIMUM) $ 1. 477,S a ULTIMATE LoA.o e)gvpC1Ty NOTES: D 1. SEE DETAIL 'B' PAGE 4 NOR MARRIAGE WALL OPENNCS GREATER THAN 491NCHES. & U P To 1-7T-6" 'l121 B a44 P 2. SEE TIE -DOWN SPACING CHART ON PAGE 2 EDR P ANCHOR AND TIE -DOWN PLACEMENT. 3. SEE DETAIL 'A' PAGE ROR TYPICAL 1-BEAN PIER CONSTRUCTION. 11 O`�• •Tsui' q •` too. CO3S4S�' ;• STATE OF I r ''• "4 O 1110 % DAPIA APPROVAL: APPROVED BY � 0E 2 'NON II C No b�rtT'Y�"ssMovc6 JACOBSEN HOMES NOTICE-°'" BY: DI REVLEITTR THESE sPEaFIUTNIns AHD DftAWNGS ARE RR 10-31-95 m UNIHAL. PROPRIETARY. AHD C04MTNL DRAWING 11T1iYATERIAES OF JACOM YANWACTWNG P.O. BOX 368 W- SxH MATERXS ARE PROMED TD 1NE ZONE I TIE -DOWNS SAFETY HARBOR. FLORIDA 34695 KOVIT FOR SPELFC Roan AID mm SE DRAWING NUYBD2: PHONE (813) 726-1138 KEPT COW MTK MO SECRET TROT OTHERS AD-Zl -0001 74 ZONE I TIE -DOWN PLACEMENT 7MCAL I -BEAM nE-ooWN MAIN FRAME I -BEAM SEE NOTE— MAIN FRAME I -BEAM END CENTER SPACING CENTER SPA SPACING ISPICIAnGI ACING SPACING I I DOUBLE WIDE TIE -DOWN PLACEMENT END CENTER CENTER CENTER CENTER CENTER END ��••I —Aw.1u JrAul•ns WAUNU Y UMING TWICAL I -BEAM TIE -DOWN MAIN FRAME I -BEAM SEE NOTE �11 `SEE NOTE 01— MAIN FRAME I -BEAM MAIN FRAME I -BEAM - LEND CENTER CENTER END SPACING ISPACING SPAT'-'T'��1 TRIPLE WIDE TIE -DOWN PLACEMENT NOTES: ENGInMjjV.LRNL. T' SEE DETAIL 'B' PAGE 4 FOR BLOCKING AND ANCHORING OF �� fC,R�IFIC•q�:•C�%/ MARRIAGE WALL OPENINGS WIDER THAN 49 INCHES. ND.004548$ 'STATE OF ce ce ce DAPIA APPROVAL• APPROVED BY 11 FTIxI ca..vaxmh"wmnvQq" LETTut JACOBSEN HOMES ,NSF SKOnCATR1011�5 AM DRAWRZ ARE• mon"sx• TU RR °A 10-31-95 REV. WGINAL PR"ETARY. AND EDtdWTIAL DRAWING TITLE s : P.O. BOX 368 MATERM OF JACOM MNAUPo IFACTNc T1E-DOWN PLACEMENT ,I We SUCH UATEFULS ARE PROMED TO THE SAFETY HARBOR. FLORIDA 34695 Form FOR 7Etj1C RINSES AND MM BE DRAWING NUMBER PHONE (813) 726-1138 Iasi Cd:WAk Apo SECRET n= ormm AD-Z1-0020 7R ZONE I INSTALLATIONS 1.! FOR HOMES LOCATED IN ZONE I, FOLLOW THE MANUFACTURER'S ZONE 2 INSTALLATION INSTRUCTIONS FOR THE INSTALLATION OF LONGITUDINAL ANCHORS. 2.I FOR HOMES LOCATED IN ZONE I ONLY, FOLLOW THE MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR THE INSTALLATION OF SHINGLES AND/OR LAP SIDING. FOR ALL OTHER WIND ZONES REFER TO DETAILS IN THE SET-UP MANUAL AND/OR THIS ADDENDUM. BY a cd. FE8 0.1 2000 INC. ) ww 11 NOT= uaemm or. vn¢: —1.. JACOBSEN HOMES T,KSC > 706 AM DRAB AK M.T. 2-1-00 M=IPA. "wwT"T. µo Cuol xlm DRAWM 11T1E. P.O. eox ]61! °AWRA�s Or 4W=WN UUWACrJPWe ZONE 1 INST. Mc. Wa UUMAU ACE MWO TO mt SAFETY HARBOR, flORIDA 3�1695 Kwm rap rm rwoas AN rrn k OpA.NWC MD18ER PHONE (727) 726-1138 Wf avuma9+l Aw SM NOW urmm - f10—Zl—01Q0 77 ADDENDUM FOR INTERSECTING UNITS MAIN UNIT /noRUER LONGITUDINAL TIES ONLY REQUIRED 0 EA HALF OUTSIDE BEAM THIS END, EXCEPT FOR ZONE 3 EXP. 'D' THEN 2 REOUARED EA HALF (IE CI-'E EA. BEAM, ETC...) VERTICAL AND DIAGONAL TIES INSTALLED ALONG THE SIDEWALLS SAME AS THE MAW UNIT. VERTICAL. TIES AT CENTER LINE REQUIRED ONLY AT COLUMN SUPPORTS PER DOUBLE WIDE CONNECTION REQUIREMENTS. 24' MAXIMUM SPACING TO FIRST SIDWALL TIE FROM EACH END OF THE UNIT (SAME AS TYP. DC IBIE WIDE TIE -DOWN REQUIREMENTS). 2 LONGITUDINAL TIES REWIRED AT EACH HALF THIS END ONLY. MAXIMUM PIER HEIGHT FOR VARIOUS ZONES (REFER ALSO TO SIDEWALL TIE -DOWNS MAXIMUM HEIGHT} ZQHE1 70W EXPOSURE 'C' 90' 56' EXPOSURE V 39" 46- CONNECT THE TRIPLE WIDE OR QUAD. WIDE SECTION(S) TO THE DORMER AND MAIN UNIT PER DOUBLE WIDE MARRIAGE LINE DETAILS AS OUTLINED IN THE SET—UP MANUAL (EXCEPTION: NAILING ONLY IS REQUIRED AT FLOOR CONNECTION. NO STRAPS ARE ' REQUIRED TO BE INSTALLED ACROSS THE FLOOR CONNECTION AT THIS AREA) .NOTES: EN ROV • • • .. "r DAPIA APPROVAL' ;•��p �°E, APPROVED BY 1. FOR WAD SECTIONS. EACH WUBLE SECTION' OF THE UNIT SHALL BE DESIGNED Q` No. O /Fa, - INDEPENDENT OF THE OTHER STRUCTURE (IE. SHEARWALLS, TIE -DOWNS, RIDGE- EN 0357 BEAMS, COLUMN SUPPORTS, ETC... ARE CALCULATED FOR EACH MULTI -SECTION.) _ JUN 1 5 1955 q.i " F ' •....... ' (� csa�R,aarowrnswow+oe A NOTICE DRAWN BY: DATE REV. LETTER: JACOBSEN HOMES THESE SPEOnCAT10NS AND DRAMNM ARE C.E.Y. 5-16-95 OMONAL PROPIOETAFM AND OOIU1Oi1iTUL DRAWING TITLL MATEMALS OF JACOM MAN UFACTIIRWC P.O. BOX 368 III- M NATURWS ARE PROMOM TO THE ADDENDUM -INT. UNITS SAFETY HARBOR. FLORIDA 34695 AECRENT Fa SKCt1C R/II'OSFS NO MJST BE DRAWING NUMBER PHONE (813) 726-1138 01 CWWTA AND SECRET idol OTlm QUADA001 78 p 2. ALT. ROOF ASSEMBLY FOR MULTI-WIDES CENTERLINE CONNECTION FOR QUAD UNITS IS THE SANE AS FOR THE MAN UNIT (REFER TO SET-UP DETALSj GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS IOVED FROM ROOF IN ORIGINAL CONDITION CEPT FOR STAPLE HOLES)L EL STRIP MAY BE CONTINUOUS OR PIECED. NGLES IN THE DORMER AREA OF THE MAN UNIT MAY SHIPPED LOOSE AND INSTALLED ON SITE AFTER UNITS HAVE BEEN ATTACHED TO PREVENT ANY NSIT DAMAGE AND TO ENSURE THE SHINGLES UNE-UP MM ONE SECTION TO THE NEXT. JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 30 GA. GALV. STEEL STRIP INSTALLED OVER MATING LINE JOINT (SEE PLAN NEW BELOW) ROOF PUMIETER RAL OR ROM BEAM CROSS-SECTION 30 GA. GALV. STEEL STRIP 8' X LENGTH OF ROOF ISECTIONS MAY BE OVERLAPPED MIN.). W/STAPIES AS SHOWN. INSTALL ROOF CAP PER SET- UP MAN. OVER GAILY. STRIP. (SEE NOTE 1) 30 CA. CALV. STEEL STRIP SECURED WITH 7/16' X 16 GA STAPLES FULL PENETRATION INTO DECUNG 2 " O.C. MAX. SPACING (TYP.) �GT'S TER `oF Q• No. �O '• ENE8703571� ,,�,��;; . !�0 RAIN . •'�� 10 .. N047CE 4Ni 10Ii1M� 1NESE SKOMTXMS AND DRAWINGS ARE OR PL. PROPRIETARY. AND oOtOID mi. DRAWING TITLE: MATLRIAI.S OF .IACOBSEN MAMXACMUG NG RICH MAIDW ARE PRMW TO THE KWOR FOR 9M PUTO.S<S NO M51 K DRAWING NUM WT CW MTLAL AND XCRET MROI OTHERS. 31 X 5' LAG SCREWS 18' O.C. (ZONES 2 Hr 3) STAGGERED r -DBYkR"- 419.�1N 1 5 1�95 INC, u.rMr.nln®�ort nucallowmcwaWTs C.L.Y. DATE: 5-16-95 ALT. ROOF ASSEMBLY III It QUADADD2 79 EIEIFIF� EIEIEF� ElIFF-1 JACOBSEN HOMES 600 PACKARD COURT SAFETY HARBOR, FLORIDA 34695 (727) 726-113 8