BLOWER DOOR TEST FORM St. Lucie C©anV
House Infiltration Test Certification
Prescriptive and Performance Method
/ Q v5
FILE CODV
RECEIVED
FEB 0 12019
ST. Lucie County, Permitting
Permit #: S L C ` �_O - 0 ��� g-
:;','C) C"rob (1L.J-JvdI-e- J)"r-
(Yj New Construction - Complete
;e Infiltration T st Results SLC Climate Zone 2
(50) = � Test Date:
me = 15 2
(50) = CFM (50) x 60 / Volume =
ing results must be & ACH (50) or less
( ) Existing - After Addition
hanical Ventilation required less than 5 ACH
Pass ( ) Fail
t•t3c„ tnergy
The uilding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (1) or an
appoved third party. A written report of the results of the test shall be signed by the party conducting the test and
prodded to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC Residential
Wh ilre the air infiltration rate of a dwelling unit is less than 5 air changes per hour when tested with a blower door at a
pre sure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the 1welling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Co ,pany Name: GFA International, Inc. Address: 607 NW Commodity Cove, Port St. Lucie, Florida
I he eby certif at the above House Inf'Itration results demonstrate compliance with FBC Energy Conservation
reg firemen$ in 4ccorclancg. t Sectio i R402.4.1.2 Climate Zone 2.
Sign,pture: yam/ "C' /L—.
Prin' lede: Sc.h k .L
Licei, se/Certification #: ID �.-� � � ` e 2__ 2,
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
RECEIVED
Fort Pierce, FL 34982
772462-2165 Fax 772462-6443
FEB 01 2019
FBC ENERGY CONSERVATION CODE
-
Duct Sealing Certification
Prescriptive and Performance Method
ST. Lucie County, Permitting
t
Date: ` Permit #: r^ v I D V ( — d 55=Z
Lot #:
I it "'t) 9J-0 0
,.
Address: '2; 63 a Gt b Le, scl� jl� � r' > �1 r✓ r `� "
Contra tor: 1 /
/ _6
Construction: ost Construction Test
I
❑ Rough -in Test
Test Conditions:
L
Floor Area (ft2):
7�
TimltIe:
Indoor Temperature (F): _(�� r
Primary Location of Supply Ductwork
Primary Location of Return Ductwork
Outdoor Temperature (F):
Total Leaka-ge Test (Outside)pp�
Duct Leakage: ❑ Defaur ❑ Prop. Leak Free `,Proposed On = D a V
Test
ressure: (Pa)
Baseline Duct Pressure (optional)
(Pa)CL,
Duct
ress. (Pa)
Flow Ring
Installed
Fan Press
Flow (cfm)
Results: •Pass ❑ Fail
Total Leakage (cfm):
_ram
,I
Total Leakage per 100 sgft:
I
CFM25 x 100 divided by the CFA = Duct Leakage CFNI1100 sqft.
Compa�,certify
y Name: GFA International, Inc. Address: 607 NW Commodity Cove, Port St. Lucie, Florida 34986
1 hereb that the above Duct Sea[ gLeakage results demonstrate compliance with 5, Edition FBC Energy Conservation requirements in accordance with
n n 1
PrintedLme: D _ �/i 1 CCI)6�se/Certificate #: