FLOOD SOLUf1d-N' ,TM 1MbDEL "FS-HEX"
FEMA COMPLIANT, ICC CERTIFIED ENGINEERED FLOOD VENTS
FEMA!°Compliant Engineered Flood Vents meet FEMA requirements when installed properly.
• Use 'it least 2 flood vents per enclosed area below flood grade, installed on at least two separate walls.
• The it
of the flood vent opening must not be higher than 12 inches above the grade.
• At le19st 1 square inch of engineered opening for every 1 square foot of enclosed space.
• ICC-ES CERTIFIED VENT
Model
Minimum Opening
Tip to Tip
Engineered
Opening
fty
Required
Dimensions
Covers
jj� FS-1608-HEX
16" Wide x 8" High
18-1/2"W x 10-1/2"H
110 sq ft
Frame''IALUMINUM; .063" minimum thickness, with 6 square openings in front face, each opening in the
vent is;'d' hexagon
Finish each vent has a satin sanded finish. This finish may be field p t