HomeMy WebLinkAbout1612-0282-CERTIFIED ENGINEERED FLOOD VENTSSCANNED By FLOOD SOLUf1d-N' ,TM 1MbDEL "FS-HEX" FEMA COMPLIANT, ICC CERTIFIED ENGINEERED FLOOD VENTS FEMA!°Compliant Engineered Flood Vents meet FEMA requirements when installed properly. • Use 'it least 2 flood vents per enclosed area below flood grade, installed on at least two separate walls. • The it of the flood vent opening must not be higher than 12 inches above the grade. • At le19st 1 square inch of engineered opening for every 1 square foot of enclosed space. • ICC-ES CERTIFIED VENT Model Minimum Opening Tip to Tip Engineered Opening fty Required Dimensions Covers jj� FS-1608-HEX 16" Wide x 8" High 18-1/2"W x 10-1/2"H 110 sq ft Frame''IALUMINUM; .063" minimum thickness, with 6 square openings in front face, each opening in the vent is;'d' hexagon Finish each vent has a satin sanded finish. This finish may be field p t FLOOD SOLUTIONS, LLC. One Industrial Park Drive Bldg. 27 Pelham NH, 03076 Toll Free: 1-800-325-9775 In NH: 603-595-5222 Fax: 603-595-4778 www.floodsolutions.com info@floodsolutio ns.com PROJECT I CONTRACTOR DATE