I have reviewed Florida Product Approval (FL13192) Hardie Plank Siding
nd the product is approved for use in the HVHZ. The product is hereby
pproved for the 165 mph Exp C requirement.
Given the owner provided information that there are (24) support piers,
>uming that each pier has a 2 sf column pad below and the in -situ allowable
I bearing pressure is 2400 Ib/sf. The foundation is able to sustain the
litional gravity load imposed by the heavier cladding.
The flood vent is as follows, Flood Solutions FS-1608-hex 18-1/2 x 10-1/2,
quantity (10). Installed all four sides and within 3 ft of every corner.