HomeMy WebLinkAbout1612-0282-LETTER-HARDIE PLANK SIDING1-6SCANNED L BY onald J. Nuelle P.E. 1634 S.W. Rowena Street ort Saint Lucie, FL 34987 ►t. Lucie County Building Department 300 Virginia Avenue 1. Pierce, FL 34982 oe Cicio �flumacki Residence �10701 S. Ocean Dr. 866 gensen Beach, FL 34957 Rermit 1612-0282 Mr. Cicio r Mr. Cicio, Date: 1 /17/2017 I have reviewed Florida Product Approval (FL13192) Hardie Plank Siding nd the product is approved for use in the HVHZ. The product is hereby pproved for the 165 mph Exp C requirement. Given the owner provided information that there are (24) support piers, >uming that each pier has a 2 sf column pad below and the in -situ allowable I bearing pressure is 2400 Ib/sf. The foundation is able to sustain the litional gravity load imposed by the heavier cladding. The flood vent is as follows, Flood Solutions FS-1608-hex 18-1/2 x 10-1/2, quantity (10). Installed all four sides and within 3 ft of every corner. If you or any other affected party have any questions or require additional rmation, please contact me at (561)-629-6975. on 7J.iuelle P.E. 52046 S1r�Y v JAN 2 6 RECD D 1