Loading...
HomeMy WebLinkAbout0704-0263- ENERGY EFFICIENCY CODEFO N 60OA-2004R EnergyGauge@ 4.5.2 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A ect Name: Mod-305 Builder: Jacobsen Homes ress: 10701 South Ocean Drive Permitting Office: St. Lucie County , State: Jensen Beach, FL 34957- Permit Number: Q70C f —D�*,5 ter: Barbara Stahl Jurisdiction Number: late Zone: Central 1. V New construction or existing New 2. !I Single family or multi -family Single family — 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 2 5. ,i Is this a worst case? _ No 6. Conditioned floor area (W) 901 ft2 7. '1 Glass type and area: (Label reqd. _ by 13-104.4.5 if not default) liU-factor. Description Area (or Single or Double DEFAULT) �. 7a. (Dble, U=0.3) 133.3 ft2 SHGC: (or Clear or Tint DEFAULT) 7b. (Clear) 133.3 W — 8. ji Floor types ". Raised Wood, Post or Pier R=22.0, 90LOW N/A _ I. N/A 9. Wall types _^ Frame, Wood, Exterior R=19.0, 908.3 R2 — N/A N/A _ N/A N/A _ 10 i Ceiling types — Under Attic R=30.0, 911.0 ft2 N/A N/A _ _ 91 Ducts Sup: Unc. Ret: Con. AH: Interior _ Sup. R=6.0, 70.8 ft . N/A = 12. Cooling systems a. Central Unit Cap: 20.5 kBtu/hr _ b. N/A APPROVED BY SEER:13.00 _ c. N/A MAR t 6 2007 13. Heating syste a. Electric Heat p I' `► Qp: 14.2 kBtu/hr _ HSPF:7.70 _ b. N/A c. N/A a — 14. Hot water systems a. Electric Resistance Cap: 30.0 gallons _ EF: 0.93 • _ b. N/A c. Conservation credits _ (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits PT, CF, — (CF-Ceiling fan, CV -Cross ventilation, BF -Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.15 Total as -built points: 11906 PASS Total base points: 12669 I 11 q reby certify that the plans and specifications covered by th s calculation are in compliance wit the Florida Energy C de. P i EPARED BY: D TE: I II reby certify that t ' tilding, as designed, is in compliance wi h the Florida E rgy C de. O NER/AGE : a.. DIATE: 3-13-Z-oo'l 1 1 redominant glass type. For actual glass type and areas, see Summer & Review of the plans and za$sT specifications covered by this calculation indicates compliance the Florida Energy.Code. y,�%, _ = with I" ,,,,, Before construction is completed a this building will be inspected for a� compliance with Section 553.908 Q Florida Statutes.c BUILDING PFFI IAL: DATE: i�It6,1?M-7 SPt1) ` 01 f;C' Winter Glass output on pages-2&4. .. _u.z1q'Version: FLKCjo L-'h ��'+"rkn".tY'*' 'red:PA '-7 0 Summary Energy Code Results Residential Whole Building Performance Method A ` B rbara Stahl Project Title: Class 3 Rating 1 �701 South Ocean Drive Mod-305 Registration No. 0 Jnsen Beach, FL 34957- Climate: Central 11 3/13/2007 Building Loads Base As -Built Summer: 17605 points Summer: 23144 -points Winter: 3659 points Winter: 2029 points Hot Water: 4526 points Hot Water: 4526 points Total: 25791 points I Total: 29700 points Energy Use Base As -Built Cooling: 5722 points Cooling: 6065 points Heating: 2027 points Heating: 974 points Hot Water: 4920 points Hot Water: 4867 points Total: 12669 points Total: 11906 points PASS e-Ratio: 0.94 EnergyGauge®(Version: FLRCSB v4.5) M 60OA-2004R EnergyGauge® 4.5.2 . t SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ZESS: 107,01 South Ocean Drive, Jensen Beach, FL, 34957- PERMIT #: BASE AS -BUILT GLASS TYPES 1 X Conditioned X BSPM = Points Overhang + Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .1 i 901.0 24.35 3949.0 1.Double, U=0.35,Clear NE 0.8 5.4 15.3 43.69 0.98 652.0 2.Double, U=0.35,Clear NE 0.8 5.4 12.8 43.69 0.98 545.0 3.Double,U=0.35,Clear NE .0.8 3.8 8.5 43.69 0.94 349.0 4.Double,U=0.35,Clear NW 1.1 7.8 12.8 38.26 0.98 480.0 APPROVED BY 5.Double,U=0.35,Clear NW 1.1 5.4 12.8 38.26 0.95 463.0 6.Double,U=0.35,Clear NW 1.2 7.2 6.1 38.26 0.97 225.0 00H 7.Double,U=0.35,Clear NW 1.2 8.1 6.1 38.26 . 0.98 228.0 MAR 16 2007 rp 8.Double,U=0.35,CIear SW 0.8 5.4 25.5 52.19 0.97 1297.0 9. Double, U=0.35,Clear SW 0.8 3.8 4.1 52.19 0.92 193.0 INC. 10.Double,U=0.35,Clear SE 1.1 5.4 25.5 55.70 0.93 1322.0 11.Double,U=0.35,Clear SE 1.1 5.8 4.1 55.70 0.94 212.0 I, As -Built Total: 133.3 5966.0 I'I WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0.0' 0.00 0.0 1. Frame, Wood, Exterior 19.0 908.3 1.00 908.3 Exterior 908.3 1.90 1725.8 Bale Total: 908.3 1726.8 As -Built Total: 908.3 908.3 I D OR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 43.4 4.80 208.3 Exterior 43.4 4.80 208.3 Ba�e Total: 43.4 208.3 As -Built Total: 43.4 208.3 C I ILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Un Iler Attic 901.0 2.13 1919.1 1. Under Attic 30.0 911.0 2.13 X 1.00 1940.4 Ba le Total: 901.0 1919.1 As -Built Total: 911.0 1940.4 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Sla 0.0(p) 0.0 0.0 1. Raised Wood, Post or Pier 22.0 901.0 1.36 1228.1 Rased 901.0 -3.43 -3090.4 BalslIe Total: -3090.4 As -Built Total: 901.0 1228.1 INFILTRATION Area X BSPM = Points Area X SPM = Points 1I 901.0 14.31 12893.3 1 901.0 14.31 12893.3 E ergyGauge® DCA Form 60OA-2004R ' II f . FO,.� M 600A-2004R EnergyGauge® 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details c ADDRESS: 10701 South Ocean Drive, Jensen Beach, FL, 34957- PERMIT #: BASE AS -BUILT FTCal mmer Base Points: 17605.1 Summer As -Built Points: 23144.4 Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) i (sys 1: Central Unit 20500btuh ,SEER/EFF(13.0) Ducts:Unc(S),Con(R),Int(AH),R6.0(INS) 23144 1.00 (1.08 x 4-.150 x 0.90) 0.260 0.902 6065.0 17606.1 0.3260 6721.7 23144.4 1.00 1.117 0.260 0.902 6066.0 DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 s F RM 600X-� 004R EnergyGauge® 4.5.2 WINTER CALCULATIONS it Residential Whole Building Performance Method A - Details 1 ADDRESS: 10701 South Ocean Drive, Jensen Beach, FL, 34957- PERMIT #: I PI BASE 1 AS -BUILT LASS TYPES _ 18 X Conditioned X BWPM = Points Overhang i Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point 8 901.0 9.11 1477.0 1. Double, U=0.35,Clear NE 0.8 5.4 15.3 3,88 1.00 59.0 l 2.Double,U=0.35,Clear NE 0.8 5.4 12.8 3.88 1.00 49.0 3.Double,U=0.35;Clear NE 0.8 3.8 8.5 3.88 1.00 33.0 4.Double, U=0.35, Clear NW 1.1 7.8 12.8 4.08 1.00 51.0 APPROVED BY 5.Double,U=0.35,Clear NW 1.1 5.4 12.8 4.08 1.00 51.0 6.Double,U=0,35,Clear NW 1.2 7.2 6.1 4.08 1.00 24.0 7.Double, U=0,35,Ciear NW 1.2 8.1 6.1 4.08 1.00 24.0 MAR 1 6 2001 8.Double, U=0.35,Clear SW 0.8 5.4 25.5 1.45 1.01 37.0 9.Double, U=0.35,Clear SW 0.8 3.8 4.1 1.45 1.02 5.0 I0 10.Double, U=0.35,Clear SE 1.1 5.4 25.5 0.69 1.03 18.0 NC11.Double,U=0.35,Clear SE 1.1 5.8 4.1 0.69 1.03 2.0 As -Built Total: 133.3 353.0 �ALLTYPES Area X BWPM = Points Type R-Value Area X WPM = Points acent 0.0 0.00 0.0 1. Frame, Wood, Exterior 19.0 908.3 1.10 999.1 908.3 2.00 1816.6 B'se Total: 908.3 1816.6 As -Built Total: 908.3 999.1 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 43.4 5.10 221.3 E enor 43.4 5.10 221.3 'I se Total: 43.4 221.3 As -Built Total: 43.4 221.13 �EILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Point dn' der Attic 901.0 0.64 576.6 1. Under Attic 30.0 911.0 0.64 X 1.00 58 u B, I se Total: 901.0 576.6 As -Built Total: 911.0 583.0 � LOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points S ab 0.0(p) 0.0 0.0 1. Raised Wood, Post or Pier 22.0 901.0 0.14 125.2 wised 901.0 -0.20 -180.2 Base Total: -180.2 1 As-BuiitTotal: 901.0 125.2 I FILTRATION Area X BWPM = Points . Area X WPM = Points nergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FILE 'Py I i FO' Ma600A-2004R EnergyGauge® 4.5.2 t WINTER CALCULATIONS 'l Residential Whole Building Performance Method A - Details ',ADDRESS: 10701 South Ocean Drive, Jensen Beach, FL, 34957- PERMIT #: BASE AS -BUILT inter Base Points: 3659.1 Winter As -Built Points: 2029.5 Toi`al Winter X System = Heating Total X Cap X Duct X System X Credit = Heating �1 Points I Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 14200 btuh ,EFF(7.7) Ducts:Unc(S),Con(R),Int(AH),R6.0 3659.1 0.5540 2027.1 2029.5 1.000 2029.5 1.00 (1.068 x 1.160 x 0.92) 0.443 1.140 0.443. 0.950 0.960 974.0 974.0 TM' DCA Form.60OA-2004R EnergyGauge®/FiaRES'2004R FLRCSB v4.5.2 RM 60OA-2604R EnergyGauge® 4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: 10701 South Ocean Drive, Jensen Beach, FL, 34957- PERMIT #: BASE AS -BUILT ATER HEATING umber of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier Ii 2 2460.00 4920.0 O0.93 2 1.00 2433.55 1:00 �67.' As-BuiltTotal: CODE COMPLIANCE STATUS i i BASE AS -BUILT ;Cooling + Heating + Hot Water = Total Points Points Points Points Cooling + Heating + Hot Water = Total Points Points Points Points 'i5722 2027 4920 12669 1 6065 974 4867 11906 PASS EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge0/FIaRES'2G04R FLRCSB v4.5.2 FIL Py I) -17-ZO07 03:1F F.0-/0l ENERGY PERF13RMANCE LEVEL (EPL) DISPLAYCARD ESTIMATED ENERGY PE.RFORY ANCE SCORE* _ 86.8 The higher the score, the were efC►cienI the hoarse. i Barbara Stahl, 10701 South Ocean Drive, Jensen Beach, FL, 34957- 1', New construction or existing New t/ 12. Cooling systenis 2 i1 Single family or multi -family Single fancily, V a. Central Unit Cap: 20.5 ki3ta1hr _ 31 Number of units, if multi-fanrily 1 �7 SEER• 13..00 _ Ntunber of Berimotns 2 V b. NIA 1 — 5', Is this a wont Casa" NoJz oW - S 6 it- 6. Conditioned floor area (R2) 901 Et' be c. 'N/A _ 71 Class typal and area: (Label regd. by 13-104.4.J if not default) _ a. U-factor:: V r Description Area 13. Hearing systems .(or Single or Double DEFAULT) 7a. (Dble, U=0.3) 133.3 ft= jef • a. electric Heat Pu ip Cap: 14.2 kStu/hr _ b. SqGC: HSPF: 7.70 (or Clear or Tint DEFAULT) 7b. (Clear) 113." P? -L-' b_ NIA .� — Floor types a. Raised Wood, Post or Pier R=22.0, 5101.0 2 ✓ c. N!A _ b. AUA c. ;VIA 14. Hot ~water systeme Wall t}Fes T a. Electric Resistance Cap: 30.0 gallons I� Q. name, Wood, Exterior R=19.0, 908.3 ft= ✓ M.0.93. ` b. NIA _ b. NIA f c. NIA _ - d. N/A. _ c. Conservation credits _ o. N/A (HR,4eat :ecc!ren. Solar DliPrDadicaW heat pump) a. Under Attic R=30 0, 411 A, ft' 15 HyAC credits PT, CF, b. NIA {C'I C: tlirg fan, CV -Cross vantilation, w c. N/A ` HF=Whole' house fall, n^ Ih. Ducts — 1'T-Prai�ratnable TAcrinosta a. Sup: Una Rat: Con. AH: interior sup. R=6.0, 7(j.5 ft. IWZ C-Multizone cooling, ot4 S IT -a b. NIA — 1iZ-H-;viu(tizone heirting) certify that this home hus complied with the Florida Energy Efficiency Code For Building construction through the above energy saving fWures which will be installed (or exceeded) '0r ��ao this home before I inspection. Otherwise, a new EPL Display Card will be completed based on install ,Co s. �nr y::�;•?; ^, . �uild,trSigttatu .��.. _ bate: b36-l-4-WE �oge� f O Q �,Iddress of Now Cit) / L Zip:�e NOTE: The home's estimated energ> performance score 1s only available through the FLAIRES computer program. This is not a Building EnwWRating. Ifyour score is 80 or greater (or 86,1vr a'US EPA/DOE•En.-, g•Star1Ndesigr:atia ), our home mays qual fy far energy effiwiency ihortgage (EEM) incentives iif y:oir. of tair,' u. Florida: Energy Qailge Rating 'ontact the Energy Gauge }iodine at 321/638-1492 air see the Energy Gauge i146 siMe at ww%, fsec. ato, f. edit for" ., 7forrncrtion and a list ofcert�ed Raters. For information about Florida.'s'Ertergy;'Ef cleiicy Code, For.Building o, tru.0 on,,,contact the J Department o 'C'omilF., hitt , Affairs at.8S014a47-18�4 p . Predoii0;int gla;;s type, For actual glass type and togas, see Sarmnw & Winter Glass output-ort ages'-^1 Energyt3atrget (tiers on: FL 2CShp.,v4. eX. ; `TA.L Z.0 APPLICATION ENGINEERING FOR HEATING AND COOLING JACOBSEN HOMES 901 4th St. North Safety Harbor, FL 36695 Manufacturer's Model 0: MCP-1636-306 HVAC Sy6tem Type: OVERHEAD RADIAL FLEX FOR EXT PACKAGE HIP Prepared Ay La5elk+-Air Systems 03/07/07 {Method S Output C 2067) 'All rlDafs reserved: this Information Dranrlet6ry to L&Salle ar76fal Co. 8 olfe,ita. C6100101rM on this page ere Dosed On design pbrenlrters set ronh in ASMRAE and ACCA Manuals W and 0. Design calculations are based on worst case orientation. Room loads may voly hased on actr,el condiflona. ENTIRE HOUSE VALUES - DESIGN ZONE: St Lucie, FL- CENTRAL COOLING LOAD; 20,581 BTUh based OH outside temp of 00'F With inaidi temp reduced to 751. HEATING LOAD: 14,E00 DTUh based en vuteide temp of 03'r .ith iusids temp raised to 701r. CONSTRUCTION DETAILS & U FACTORS (22-19-30) OVrR4LL NONE SIZE: 47.00 % 21.66 TOTAL FLOOR AREA: 695.F6 4.1'. AVO CEILING HEIGHT: 9a.00 in, ROOF: 0.030 FLOOR DUCTS: 0.000 TRUE OUTSIDE PERIMETER: 137.33 Tt WALLS: 0.061 CEILING DUCTS: 0.107 NET WALL AREA; 910.61 a.f. FLOOR; 0.045 EXTERNAL OUOTS; 0.107 TOTAL WINOOWI AREA: 133.33 S.T. WINOORI: 0.300 CLG DUCT AREA: $8.7 s.T. TOTAL W11109WE AREA; 0.0a ■.f. WJNDDYM-. 0.400 E7.T DUCT ARFA: 90.6 e.f. ' WINDOW, % OT Tlaor: 14.99% DOORS: 0.460 PEOPLE: S TOTAL DOOR AREA; 40.28 e.f. LAT.GATN: 2413.4 DUCT 0AIII/L088:2406.2/1046.8 SUMIWIN INFIL: 71.0/142.1 ctrs ROOM BY ROOM VALUES Heat loss, host gain and CFN requirements based on Dnot daaiyn values cooling equipment design standards. when connected to standard residonTial Callbratod Blowor Toss equipment. 0 .30 in. W.G. ROOM NAME HFATING COOLING CFM COOLING COOLING BTUh LOSS STUN GAIN DIST CFId BTUh CFM BTUh .......-•----------------------._..................... Kitchen 1,219 1,370 57 .................. 10a 0,240 ...................... 117 0,900 Living Room 2,073 3,970 145 210 6,300 213 7,100 Bedroom $11 3,730 5,365 203 210 6,300 213 7,100 " Rath Al Rol 1,065 39 61 1,030 70 2,5DO BATH 2' 073 1,000 38 ad 2,670 04 3,139 9EDR4M a2 1,7.10 2,491 91 102 3,240 117 3.900 DINING ROON 2,804 ............................................•......... 4,082 178 107 .................. 5,010 211 7,033 TOTALS: 14,230 20,691 750 008 29,400 ...................... 1,040 34,607 fA14/1"11 to /da1A11 A&ApnO Or aool,ng egUlptAenr Ill of prodUces pre Tot/l Goslgn GPM fOr 11114 AOnae May rO$Vll 111 err unbalanced duct sysfern. ILE ,t kv,,PPy- DUCT AIR FLOW AND SIZING WORKSHEET (MANUAL D) JACOBSEN HOMES Model #: MCP-108-305 901 4th Street N. System Type: Overhead Radial Flex for EA Package Safety Harbor, FL Design Zone: FL -Central Frepiiied 6y LaSalle Air System! 010712007 Aq rights reserved This information proprietary to LaSalla Arista/ Co. and alien!&. Calm tlaiiarya include factors for duct airternperature change and pressure dreps through ducts. All joints ere tightly rifted or sealed. 14231 btuh Total Heat Loss Blower CFM 786 0.8 E.S.P. 20681 btuh Total Hoot Gain TEL= 272 FR= 0.107 WC Coil includeag IM-BY-ROOM User Input RO ANALYSIS I Final I Final Trunk Metal F. 0Izs9 Flex Ben&f Total Eq. Heat Cool Heat Cool Design Round Rect Size RoundVelocity 0 Duet (fl)Duct (fl)Duct (h)Finings(ft) Length Bnlh Stuh efm efm efm Size (I.d.) x (I.d.) Size fpm M, BEDROOM 1 34 160 104 3739 5505 64 212 212 6.25 0 6.0 600.3 M. B 1 k,TH 2 39 170 209 075 1032 17 40 d0 3.98 0 e.0 203.1 G 4e 4302 LIVi ROOM 1 39 160 109 2073 3970 153 153 729 0 8.0 KITCHEN 'I 2 28 160 168 1219 1578 21 59 59 4.71 0 6.0 300.E DINII'IG ROOM 2 40 u 170 210 2894 4862 48 189 169 6.04 0 8.0 636.3 BED OOM 02 2 29 180 169 1740 2491 30 94 94 5.8A 0 6.0 478.9 BAT, d1 1 25 180 165 991 1085 17 40 40 3.85 0 4.0 453.E TRU I K $1 TRUJK92 TRU .4K 15 TRU �IKt04 TRU �K95 LON EST RET1RN DUCT 20 65 115 7321 10558 20 95 115 8910 9993 0 0 0 0 0 0 12 50 62 ?ad 404 " 0.39 0 10.0 741.1 382 9.21 0 10.0 699.5 0 0 0 786 12.45 19 38 28.9 156.7 W t4 til .'�dy F L . ,� { Exterior glaziM Wind Blown Debris protection equipments is not installed or supplied with this home. Wind protection In blown debris protection equipment must be on the approved Florida products list and to be wi ndborne debris installed before the certificate of occupancy is issued. re ions If approved equipment is not installed, follow these instructions and material- specifications. Homes Installed in wind -debris regions must have provisions to protect the exterior glazing in windows and doors. Refer to Florida Building Code (FBC) figure 1609 for regions requiring this additional protection. Contact the local official to determine if your specific area is located in wind -debris regions. The protection for exterior glazing may be provided by the following: Regions with 140 MPH max. wind speed (per 1609.1.4 of FBC): 7/16" minimum APA rated sheathing for opening up to 8' maximum. Sheathing shall be precut so they shall be attached to the framing surrounding the opening containing the product with the glazed opening. Panel shall predrilled as required for the anchorage method and all required hardware shall be provided. Attachment in accordance with table 1609.1.4 (see below), with permanent corrosion resistant attachment hardware provided and anchors permanently installed on the building is permitted for buildings with a rtiean roof height of 45 or less (140 mph max). Woi We Table 1601.9.4 Wind -Borne debris protection fastening schedule for wood structural panels Fastener type A screws, 2" min. embedment' od screws, 2"min. embedment* ag screws, 2" min- embedment* Fasteners acing in. • Panel Span </= 2 ft 2'4 Panel Span <4' 4'< Panel Span <6' 6'< Panel Span <8' 16 16 10 8 16 16 12 9 16 16 16 16 Notes: 1. This table based on a maximum wind speed of 140 mph & mean roof height of 45' or less. 2. Fasteners shall be installed at opposing end of the wood structural panel. V Where screws are attached to masonry or masonry/stucco. They shall be attached using vibration anchors having a 1500# withdrawal capacity. Regions with wind speed in excess of 140 MPH: Protection of,exterior glazing in windborne debris regions with wind speed in excess of 140 mph must be provided per Florida Building . Check with local officials or a local professional engineer for required protectionprocedures and materials. Only in absence of information from your local officials -or a Florida professional engineer the following procedure may be followed. The protection for exterior glazing may be provided by APA rated sheathing, installed over the window and doors per table 1. All specified -sheathing MUST be precut and prepared with all required fasteners. Sheathing is to be bolted to the window frame with.a 0.19" dia. bolt with 5/8" washer, and a common nut. The bolts are spaced 6" on center along the long sides of the window frame. Holes will have to be predrilled into the window frame. - Use sheathing listed in table below for the application of this type of window covering. For doors, sliding glass doors and windows without flange, remove mounting screws holding the door or window frame to exterior wall. Place the required plywood (from table below) over the door or window framing and fasten the plywood and framing back into the wall studs through the same holes in the door or window frame. Use #8x3" screws 6" o.c. for windows, and #8x4" screws 4" o.c. for sliding glass doors. See Figure 1 for a typical application of this type of protective covering. TABLE 1 MAXIMUM WINDOW PLYWOOD TYPE REQUIREMENTS 30.5" 5/8" APA rated ply. 40/20 span rating 36.5" 7/8" APA rated ply. 48/24 span rating 40" 3/4" APA rated ply. 48/24 span rating 46.5" 7/16" APA rated ply. w/wood framing 72" 7116" APA rated ply. w/wood framing • " See Figure next -page for wood framing construction 1, APPROVE® BY �/l l 1 6 NOT MAR INC° Jacobsen -Homes ME1G—OZ—DDI(A� (t� FILatm: CUPA bLVY.:ws'Y4v.�'�r!RS!6lFa=t�ir::4]'der^�.ti"�.c^,:":vrt4SF'F15!!b'Cn4�� I - PROTECTION OF WINDOWS AND SLIDING DOORS: a PLYWOODFACE 2. LUMBER cRArtt SHEATHING PER 150 mph WINDOW SIZING CHART mocasmz sFETABIE i. as X 3- WOOD SCREWS n 6'O.C. 1 a� .19 diameter bolt with SIB" weber and common nut; at 6" .. Window o.e.(maximnm)L Place washer baween bob head dt I x lumba Size, we Window flame Plywood we specified apex. -Per Tablet. I x lumber (any grade SPF) SECTION B8 2 z2 ANY GRADE, FASTEN TO 2 z 4'S WR-xd NABS @y FACH INTERSECTION 2x4n2SPF16'O.C.LABIFLAT(REQUIREDFOR463" 01 LARGER WINDOWS) Ma x 3 Ur WOOD SCREWS G 6"O.C. INTO RECEIVING MEMBER FLYWOODFACE GRAIN SEE NOTES BELOW DDORFRAME WALL STUDS e §2x3'WOODSCREWS 0 6.O.C. I I KNOBFRAMING BOX OUT FOR ANY PROTRUSIONS ON DOOR SECTION AA Notes: 1) 7/16" plywood APA rated exterior sheathing with 20/0 span rating 2) Locate plywood seam over 2 x 4 member 3) Fasten plywood to 2 x framing members with full PVA white glue and 6d nails or #8 x 2" screws @ 6" o.c. all around Jacobsen Homes ' /In E-X 07- - 001 (a) f � , a ap�• Or � k!. i y 'fn+ao 1'd