Loading...
HomeMy WebLinkAbout0704-0263- SET-UP MANUALBY :. Lurjs SET-UP MANUAL oo�o 0000 JA OBS 0 HOMES 4 .r cop" •00 L%URT SAFETY HARBOR, FLORIDA 34695 (727) 726-1138 NOTICE These specifications and drawing are original, proprietary, and confidential materials of Jacobsen Manufacturing, Inc. Such materials are provided to the recipient for specific purposes and must be kept confidential and secret from others. SU-00-0000 7-12-06 MOBILE HOME SET-UP SITE PREPARATION (A.) BLOCKING (B.) LEVELING (C.) ASSEMBLY AND CLOSE-UP TIEDOWNS ELECTRICAL CONNECTIONS PLUMBING CONNECTIONS A.C. CONNECTIONS (OPTIONAL) SITE PREPARATION IF YOU ARE GOING TO LIVE IN A PARK, YOUR HOME SITE WILL BE READY OR BE PREPARED FOR YOUR HOME. IF YOU INTEND TO INSTALL YOUR HOME ON YOUR OWN LOT (NOT IN A PARK), SOME SITE PREPARATION MAY BE NECESSARY. THE SITE MUST BE GRADED TO PROVIDE FOR STORM RUN-OFF, SPECIAL CARE MUST BE TAKEN WITH THE AREA DIRECTLY BELOW YOUR HOME TO PREVENT WATER FROM PONDING AND/OR PUDDLING AROUND YOUR HOME SUPPORTS. PIER SUPPORTS MUST BE PLACED ON UNDISTURBED SOIL (ALL GRASS AND ORGANIC MATERIAL MUST BE REMOVED) OR FILL WHICH IS COMPACTED OR FULLY SETTLED (SEE PAGE 4 DETAIL 'A' AND DETAIL 'B'). IN AREAS THAT ARE SUSCEPTIBLE TO FROST, PIER SUPPORTS MUST BE BELOW THE FROST LINE. OPTIONAL: PIERS MAY BE PLACED ON CONCRETE RIBBONS 4" X 16" X LENGTH OF HOME MINUS 18", REINFORCED WITH WELDED WIRE MESH. (A.) BLOCKING UNLIKE A STANDARD HOUSE, YOUR MANUFACTURED HOUSE DOES NOT NEED A FOUNDATION TO SUPPORT IT COMPLETELY AROUND ITS PERIMETER. THE STEEL FRAME OR CHASSIS USED FOR TRANSPORTATION ALSO SUPPORTS THE HOME AT ITS HOMESITE. THE STEEL FRAME MUST BE SUPPORTED (SEE PAGES 5 AND 6 ) TO PREVENT YOUR HOME FROM SAGGING, AND TO KEEP IT LEVEL. NOTE: ADDITIONAL PIERS ARE REQUIRED AT ALL RIDGE BEAM SUPPORT COLUMNS EXCEPT AT THE FRAME HEADER. MAXIMUM HEICHT OF A PIER IS 24". PIERS BETWEEN 24" AND 48" MUST BE DOUBLE TIERED WITH BLOCKS INTERLOCKED AND CAPPED WITH SOLID CONCRETE OR PRESSURE TREATED WOOD. (ALSO SEE TIE -DOWN REQUIREMENTS TO DETERMINE MAXIMUM HEIGHT FROM GROUND.) ALL SUPPORTING STRUCTURES OR PIERS OVER 48" HIGH MUST BE APPROVED BY A REGISTERED PROFESSIONAL ENGINEER. (B.) LEVELING PROPER BLOCKING SEQUENCE IS ESSENTIAL IN THE LEVELING OF YOUR HOME. (SEE BLOCKING DETAILS ON PAGES 5 AND 6 ) FOR THE RECOMMENDED BLOCKING SEQUENCE TAKING CARE TO CHECK YOUR LEVEL BETWEEN EACH STEP AND SUPPORT. RECOMMENDED LEVEL IS A 48" CARPENTER'S LEVEL. (SEE ACCEPTABLE LEVELING GUIDE BELOW) BUBBLE CARPENTER'S LEVEL 11 1 /8 IS MAXIMUM ACCEPTABLE A JACOBSEN HOMES NOTICE: DRAWN BY: THESE SPECIFICATIONS AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING SAFETY HARBOR, FLORIDA 34695 INC. SUCH MATERIALS ARE PROVIDED TO THE PHONE 727 7ORIDA 8 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBI KEPT CONFIDENTIAL AND SECRET FROM OTHERS. S.A. DATE. 6-6: REV. LETTER: MOBILE HOME SET-UP - SU-01-0001 MAIN WOOD S (DECAY RESISTANT) AND/OR TREATED LUMBER PIER CAPPED WITH SOLID CONCRETE---' BLOCK MIN. 4' THICK) 8' X 8 X 16' CELLED MASONRY BLOCKS WITH EN CELLS VERTICAL SEE TA ILE I FOR PIER FOOTER `SIZING LND SPACING SPECIR, ATIONS (PAGE 11) ,(SEE -4A FOR 16 X 16 r PRECA PIER PAD SPACING) AND PI BELOW CODE I NOTE ALL ORGANIC MATERIAL- CE PAD ON STABLE SOIL ROST LINE PER LOCAL r ;`• TO RI EACH TO A SEE r DOUBI STRAPS ATTACHED BEAM COLUMNS ON TION TO BE CONNECTED BLE HEADED ANCHOR 14 SEE NOTE f2 -/ DETAIL `A' DETAIL 'B'. 1. 48' MAX. FOR HOLLOW BLOCKS. 72' MAX PIER BLOCK WITH CELLS S COMPLETELY FILLED WITH CONCRETE (PIER SY57EMS ANY TALLER MUST BE APPROVED BY A LICENSED ARCHITECT OR ENGINEER) 2. MAXIMUM PIER/PAD EXPOSURE: 1000 PSF SOIL — B' 1500 PSF SOIL — 6 3/4' 2000 PSF SOIL — 5 3/4' 2500 PSF SOIL — 3 3/4' 3. MARRIAGE WALL OPENING PIERS TO BE WITHIN 6' OF OPENING ON EITHER SIDE OF COLUMN. 4. MINIMUM PIER PAD THICKNESS: A. 4' MIN. FOR PRECAST UNITS UP TO16'X16" B. FOR CAST IN PLACE FOOTINGS MIN. THICKNESS IS MAX FOOTING DIMENSION DIVIDED BY 4. (BUT NOT LESS THAN 4') 5. ALL FOOTING CONCRETE. TO HAVE COMPRESSIVE STRENGTH. (fc') n 3000 PSI (MIN.) 6. PLACE 4 MIL POLY ON GROUND PRIOR TO POURING FOOTING CONCRETE 7. ALL PIERS MUST BE CENTERED ON FOOTING. B. FOOTING CONSTRUCTION MUST COMPLY TO LOCAL BUILDING CODES. SEE NOTE 12 (DIMENSIM 0111000 ETC-) - 199.4_ INC �awrr,..s WOOD SHIMS (DECAY RESISTANT) AND/OR PRESSURE TREATED LUMBER PIER CAPPED WITH SOLID CONCRETE BLOCK (MIN. 4' THICK) 8' X 8' X 16' CELLED MASONRY BLOCKS WITH OPEN CELLS VERTICAL (SEE NOTE 11 FOR MAX. PIER HEIGHTS AND DETAIL ABOVE) SEE TABLE FOR PIER FOOTER SIZING AND SPACING SPECIFICATIONS (PAGE 10) REMOVE ALL ORGANIC MATERIAL AND PLACE PAD ON STABLE SOIL BELOW FROST LINE PER LOCAL CODE REQUIREMENTS .--SEE NOTE 112 (DIMENSION VARIES WITH MAX. ALLOWABLE SOIL BEARING) SU - o1-CCXA REV. 9-7-93 SU-4.1 MOBILE HOME SET-UP NOTES: 1. JACKS TO BE RATED AT 5 TONS. 2. ALWAYS USE A SUPPORT UNDER JACKS. 3. FOLLOW BLOCKING INSTRUCTIONS. 4. FOR MULTIPLE WIDES SET HEAVY SECTION FIRST. BLOCKING SEQUENCE 1. LOCATE HOME ON SITE AND LEVEL AS CLOSE AS POSSIBLE USING HITCH JACK. 2. SET SUPPORTS (BLOCKS #1) UNDER BOTH I -BEAMS JUST FORWARD OF THE FRONT SPRING HANGERS. 3. SET SUPPORTS (BLOCKS #2) UNDER BOTH I -BEAMS JUST BEHIND THE REAR SPRING HANGERS. 4. LOCATE SUPPORTS (BLOCKS #3) APPROXIMATELY 24" BEHIND THE FRONT CP.OSSMEMBER. 5. LOCATE SUPPORTS (BLOCKS #4) APPROXIMATELY 24" FROM THE END OF THE HOME. 6. ADDITIONAL SUPPORTS (BLOCKS #5) MAY BE NECESSARY BETWEEN 1 & 3 AND 2 & 4, IF THEY ARE NEEDED THEY SHOULD BE SPACED EQUALLY, MAXIMUM SPACING 10'-0". 7. IF YOUR HOME HAS 4 AXLES ADD BLOCKING BETWEEN THE MIDDLE SET OF AXLES. 8. FOR SINGLE WIDES BLOCKING IS COMPLETE. 9. FOR MULTIPLE WIDES REMOVE ALL SHIPPING BATTENS AND VISQUEEN AND SET LIGHT SECTIONS) AS CLOSE AS POSSIBLE TO THE ALREADY SET HEAVY SECTION. 10. JACK THE LIGHT SECTION(S) TO THE HEAVY SECTION USING JACKS AND COME-ALONGS. 11. FOLLOW BLOCKING SEQUENCES 1 THRU 7. NOTE: PERIODIC RELEVELING MAY BE NECESSARY BECAUSE OF THE WEIGHT OF THE HOME AND SETTLING THAT MAY OCCUR. ❑❑❑❑ JACOBSEN HOMES NOTICE: DRAWN BY: DATE: REV. LETTER: THESE SPECIFICATIONS AND DRAHTNGS ARE S.A. 6-6-94 ADDED ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITL : _ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING MOBILE HOME SET-UP #2 SAFETY HARBOR, FLORIDA 34695 INC. SUCH MATERIALS ARE PRONDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS SU-01-0002 L SEE NOTE #6 SEE NOTE #2 SEE NOTE #7 NOTE #1ll� NOTE #5 SEE NOTE #3 TYPICAL SINGLE WIDE BLOCKING (SEE SU-01-0004 FOR NOTES) SEE NOTE #7 SEE NOTE #6 IVV IL �J JtL NOTE #3 TYPICAL DOUBLE WIDE BLOCKING (SEE SU-01-0004 FOR NOTES) We 11 � 000 omo JACOBSEN HOMES P.O. BOX 36B SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE ORIGINAL, PROPRIETARY. AND CONFIDENTIAL MATERIALS OF MANUFACTURING INC. SUCH MATERIALSRIALS ARE ARE PRONGED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST RE KEPT CONFIDENTIAL AND SECRET FROM OTHERS DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: i DRAWING TITLE: DOUBLE WIDE BLOCKING DRAWING NUMBER: SU-01 -0003 SEE NOTE #7 SEE NOTE #6 I (Z) 1 (3) I X� SEE NOTE TYPICAL TRIPLE WIDE BLOCKING \-SEE NOTE #7 NOTES #1-MAIN FRAME I -BEAMS #2-LOCATE PIERS UNDER FRAME I -BEAMS #3-LOCATE PIERS UNDER CLOSEST FLOOR JOIST EACH SIDE OF OPENINGS 48" AND LARGER. (I.E.-RECESSED ENTRIES AND SL. GL. DRS.) SEE TABLE FOR PIER FOOTER SIZING PAGE 10. #4-LOCATE PIERS UNDER MARRIAGE WALL PERIMETER JOISTS WITHIN 6" OF EACH SIDE OF OPENINGS. 48" & LARGER AND RIDGE BEAM COLUMNS. SEE TABLE FOR PIER FOOTER SIZING SU-01-0030 AND SEE DETAIL 'B', SU-01-0010. #5-AXLE ASSEMBLY CENTER LINE #6-SEE TABLE I FOR PIER FOOTER SIZING AND PIER SPACING INFORMATION SU-01-0040, AND DETAIL 'A' SU-01-0010. #7-BLOCKING SEQUENCE NUMBERS, SEE SU-01-0002 FOR PROPER BLOCKING PROCEDURES. ❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS DRAWN BY: S.A. I DATE: 6-6-94 REV. LETTER: AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: ❑ :EIDEOVID P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS TRIPLE WIDE BLOCKING SAFETY HARBOR, FLORIDA 34695 ARE PROVIDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS SU-01 -0004 ADDITIONAL PERIMETER BLOCKING (THIS 9-o=G Is IN ADDHION TO BLOCKING m u n IN THIS MANUAL) nr l! wrw!rAjjFl TYP. FIREPLACES ON SIDEWALL OR MARRIAGE WAIL W- OR 6D' TUB AT SIDEWML OR MARRIAGE WALL UNDER EACH SIDE OF ALL EXTERIOR DOORS LOCATED ON SIDEWALLS AB= 2 OR MORE 461/Y WINDOWS PIERS REQUIRED AT EACH END AND BETWEEN EACH OPENING RECESSED AREAS REQUIRE PIERS SPACED 64' at MAX (le OR LESS IN DEPTH) EACH END OF RECESSED AREAS - RECESSED AREAS W/SWE BAY REQUIRE PIERS SPACED 64' at MAX THIS ALSO APPLIES TO ALL ENDWALL BAY WINDOWS UNLESS SUPPORTED BY A FRAME IBBER u GARDEN TUB AT SIDEWALL OR MARRIAGE WALL 64' at MAX. --------- ---- ---- II AGII—If ------ CABINETS ALONG SIDEWALL OR LMANAGE WALL I (APPLIES TO BATH CABINETS 80' OR GREATER IN LENGTH) I (SAME BLOCKING MAY BE USED FOR MULTIPLE 461/2' WNDOWS) I SPECIAL BLOCKING NOTE FOR 15L-4H (184") WIDE FLOOR SECTIONS APPROVED BY PERIMETER BLOCIONG IS REQUIRED (MARRIAGE AND SIDEWALLS) 64' ON CENTER MAX SPACING NOTE LEVFl. FLOOR SYSTEM FIN (SID ML TO SIDEWALL OR MARRIAGE WALL) BEFORE INSTALLING PMETER BLOCKSIN May 22,2006 ES- INC. ADOTRONAL BLOWING REWIRED AS U01ED ABOVE (USE 16' X 16' HER PADS FEDERAL MANOFAMMED HOME LOCATE BLOOM UNOER PERMEIER JOT OR 11 M 8. OF DO OF 16' O.C. J= cONSTIO C710H ADD SAFETY STANDARDS PONETER BLOOM IS REQUIRED UNDER 11LE FLOCKS (MARRIAGE d S WAILS) 64' O.C. MAX. � JACOBSEN HOMES ■ NOTIC'l+ � nONscMAtr1NM o mm- W m-WETAFM AND uDtaFt mum- �n� 01: • M.T. vnlc 4-12-00 1¢r. LC11Cn: ORAWNG 1111E P.o, sox ass YAIEWAIS OF JACMEN MANWACTWUNG ADDITIONAL BLOCKING SAFETY HARBOR, FLORIDA 34695 W- 91t71 tUTERNS ARE PliOVDED TO lti REO W FOR WOO AIBPW AND NB? BE DRASBNG NUMBER PHONE (W) 726-1135 KEK ORiMOM AID SEr nW OHM CI I_M _nnng; BLOCKING (PIER) LABELS LOCATE THESE LABELS AND CHECK THE APPROPRIATE MANUAL FOR PROPER INSTALLATION OF BLOCKING AND PIERS.. SHEARWALL COLUMN PIER PIER LOCATION LOCATIONS SEE SET—UP MANUAL SEE SET—UP ADDENDUM FOR SPECIFICS (LOCATE THESE PIERS AT 6, FOR SPECIFICS THE MARRIAGE LINE) BOTTOM OF EXTERIOR SIDING AT SIDEWALL SPECIFIC PERIMETER PIER LOCATION SEE SET—UP MANUAL h� FOR SPECIFICS a BOTTOM OF EXTERIOR SIDING AT SIDEWALL NOTES: 1. THIS IS INCLUDED IN THE HOME OWNERS PACKAGE. GENERAL PERIMETER BLOCKING 64" O.C. MAX. (SEE SET —MANUAL FOR SPECIFICS) APPROVED BY 0 N 00o May 22,2006 INC.- FEDERAL MANUFACTURED HONE CONSTRUCTION AND SAFETY STANDARDS NOTICL uaerffl uI; vn�c. M.T.05-20-06 JACOBSEN HOMES THESE VEC IMMORS AND DRAIRNGS ARM DMMM. PRDPxIETIRY. AND CONFIDE G& DRAWJG 1111E. nnon P.a Box 36a '1A7QiA S OF JAmsSEN YANUFACTIMEIG BLOCKING (PIER) LABELS W. SWN MATUL&S ARE PRMUD TO THE SAFETY HARBOR, FLORIDA 34695 RMMI FOR VEM PlE8t1<AS AND W5T BE DRAVANG HUMB3C i m PHONE (727) 726-1138 IDPT OWEE/fM AND MU FRDY OEM SU-01-0006 16" X 16" PIER FOOTER SPACINGS* MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR 39" 62" 86" 110" 134" 157" 144" WADE FLOOR 33" 53" 73" 93" 113" 133" 160" VADE FLOOR 30" 48" 66" 85" 103" 121" 184" WADE FLOOR 26" 42" 58" 74" 901, 107" �11N. PIER CAPACITY 1778 LBS. 2667 LBS. 3556 LBS. 4444 LBS. 5333 LBS. 6222 LBS. NOTE: ALL UNIT WIDTHS INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. 4" MINIMUM, AND/OR PER LOCAL CODE REQUIREMENTS 4' TYP 7" OR 8" TYP 30' MAX (TYP) XQ Q NOMINAL 16" X 16" SQUARE PRECAST. T CONCRETE FOOTING T 16" MIN. '.. EACH SIDE 4 X 8 X 8'SOLID 6 X 7 X.8SOLID FOOTING CONC. BLOCKS CONC. BLOCKS TYPICAL PIER FOOTER TYPICAL PIER CONFIGURATIONS (THE CAPACITY OF THESE PIERS EXCEEDS MIN. REQUIRED) CONCRETE NOTES WINDZONE III 1. ALL FOOTINGS CONCRETE TO HAVE fc' = 3000 PSI MIN AT 28 DAYS; (110 MPH) 2. ALL SOLID CONCRETE BLOCKS TO HAVE fm' = 1500 PSI MIN; ALL EXPOSURES 3. CENTER ALL PIERS ON FOOTINGS 20 PSF ROOF 10 PSF D.L. p REF. CALCS. e W A- _ (/ � 61/r Cl S G 2 `��Sulnurru���A , 40TES: EN ., ��i� DAPIA APPROVAL: REFER TO OTHER DETAILS FOR ADDITIONAL PIER FOOTER SIZES AND v�STER No. APPROVED EY SPACINGS. 910334 •= START I -BEAM PIER SPACING 1/2 THE ALLOWABLE SPACING FROM EACH END �e0 OF THE HOME AT EACH I -BEAM, AND MAXIMUM SPACING SHOWN IN THE CHART �C NIP ABOVE FOR FULL LENGTH OF HOME SEE OTHER DETAILS FOR PIER REQUIREMENTS AND MAXIMUM OPENINGS STATE OF ;• ! Q;: • ••'•.N INC. AT HATING LINE OF MULTIPLE WOE HOMES. .� �� p..• \� �� FEDERAL MANUFACTURED HOME SEE OTHER DETAILS FOR TIE -DOWN REQUIREMENTS. ��FtSs • E CONSTRUCTI E AROS m ?�tm JACOBSEN HOMES N IC • THESE SPECF1CAnoHS AH DRAWN ARE AWN BY: M.T. DATE 2-8-99 REV. LETTER P.O. BOX 368 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURNC Nc SUCH MATERIALS ARE FRONDED TO THE DRAWING TITLE: 16" x 16" PIER SPACING SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECFIENT FOR SPECIFIC HIRPM AM MUST BE IVT CCRFI DM& AND SECRET FRAM OTFFRS DRAWING NUMBER: SU-OI -OO20 W ALTERNATE MAIN BEAM PIERS (8' X S' X 16' HOLLOW CONCRETE MASONRY BLOCKS) (NO MORTAR OR GROUT REQUIRED) MAIN FRAME I -BEAM �" •. 8" X 8' X 16' HOLLOW CONCRETE BLOCK IS SHOWN, WOOD SHIMS (DECAY RESISTANT) AND/OR �' . BUT A 8' X 4" X 16" BLOCK SOLID OR HOLLOW CORE PRESSURE TREATED LUMBER USED FOR HEIGHT ADJUSTMENT, 1' MAX. THICK OR A 1' TO 2' X 8' X 16' SOLID BLOCK MAY BE USED. ..\ (TOP LAYER ONLY). AND 4' X 8' MINUMUM SIZE PIER CAPPED WITH CONCRETE 2' OR 4' THICK OR I X OR 2 X PRESSURE TREATED LUMBER 8' X 8' X 16' CELLED MASONRY BLOCKS W WITH OPEN CELLS VERTICAL SINGLE STACK BLOCK PIER (PERPENDICULAR TO MAIN BEAM) 8,000 LEIS. CAPACITY -SEE NOTE P MAIN FRAME I -BEAM WOOD SHIMS (DECAY RESISTANT) AND/OR PRESSURE TREATED LUMBER USED FOR HEIGHT ADJUSTMENT, I" MAX. THICK AND 4' X 8' MINUMUM SIZE PIER CAPPED WITH CONCRETE 2' OR 4" THICK OR i X OR 2 X PRESSURE TREATED LUMBER 8" X B' X 16' CELLED MASONRY BLOCKS WITH OPEN CELLS VERTICAL DOUBLE STACK BLOCK PIER 16,000 LBS. CAPACITY (SEE NOTE 11 & 12) 8' X 8' X 16' HOLLOW CONCRETE BLOCKS ARE SHOWN, BUT 8' X 4' X 16' BLOCKS (SOLID OR HOLLOW CORE) OR 1' TO 2' X 8' X 16' SOLID BLOCKS MAY BE USED. (TOP LAYER ONLY). WINDZONE III (110 MPH) ALL EXPOSURES 20 PSF ROOF 10 PSF D.L. FLOOR MAXIMUM I -BEAM PIER SPACING (CONTROLLED BY PIER LOAD CAPACITIES) WITH MAX. 48" O.C. 72" O.C. 96" O.C. 120" O.C. 144" O.C. 144" WIDE FLOOR 2428 LBS. 3488 LBS. 4548 LBS. 5608 LBS. 6668 LBS. 160" WIDE FLOOR 2661 LBS. 3838 LBS. 5014 LBS. 6191 LBS. 7368 LBS. 184" WIDE FLOOR 2961 LBS. 4288 LBS. 5615 LBS. 6941 LBS. 8268 LBS. NOTE: UNIT WDTHS INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. (CHECK PIER PAD LOAD CAPACITIES BASED ON SOIL BEARING PSF) NOTES: 1. SEE SU-01-0020 FOR PIER SPACING WHEN USING 16' X 16' PIER PADS, WHEN USING 16' X 16' MIN. PIER PADS OTHER THAN CONCRETE THEY MUST. BE LISTED AND CERTIFIED TO EXCEED OR EQUAL MIN. PIER CAPACITY. 2. WHEN USING PIER PADS THEY MUST BE LISTED AND CERTIFIED TO EXCEED OR EQUAL MIN. PIER CAPACITY. 3. START I -BEAM PIER SPACING 1/2 THE ALLOWABLE SPACING FROM EACH END OF THE HOME AT EACH I -BEAM, AND MAXIMUM SPACING SHOWN IN THE CHART ABOVE FOR FULL LENGTH OF HOME ttuul111rrrr NGIN(SRLftQVAD / It Iw. Wire �/* �i ;`P No. o L 910334 STATE OF DAPIA APPROVAL APPROVED BY IN'P INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS . MAR 0 1 1999 JACOBSEN HOMES '�0T1` THESE sPECIFlCATIONS "� D DRA a ARE ''"'""" nT` M.T. DATE: 2-8-99 REV. LETTER ■❑ P.O. BOX 368 ORIGNAL. PROPRIETARY. AND DENM oo MATERIALS OF AC08SEN MANUFAC1=G DRAWING RTLE: ALT. MAIN BEAM PIERS n SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 M SUCH MATERIALS ARE PROVIDED TO THE RET]NENt FOR SPEfi1C PURPOSES ANDMUST BE KPT CONRDENTU�L AND SECRET MU 011 n H DRAWING NUMBER. SU-01-0021 16" X 16" PIER FOOTER SPACINGS* (MIN. 256 SQ.IN) MAXIMUM I -BEAM PIER SPACING 18" X 22" PIER FOOTER SPACINGS* MIN. 396 SQ.IN) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR%o 63 1/2" 100 1/2" SEE NOTE #4 SEE NOTE #4 SEE.NOTE #4 SEE NOTE #4 144" WIDE FLOOR. 54" 85" 116 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 160" WIDE FLOOR- 49" 77 1/2" 105 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 184" WIDE FLOOR** 43" 68" 931, 117 1/2" SEE NOTE #4 SEE NOTE #4 MIN. PIER CAPACITY 2747 LEIS 4121 LBS 5495 LBS 6868 LBS 8242 LEIS 9616 LBS 20" X 20" PIER FOOTER SPACINGS* (MIN. 400 SQ.I ) MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR- 64 1/2" 101 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 144" WIDE FLOOR** 54 1/2" 86" 117 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 160" WIDE FLOOR** 49 1/2" 78 1/2" 107" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 184" WIDE FLOOR- 43 1/2" 69" 94" 119" SEE NOTE #4 SEE NOTE y4 MIN. PIER CAPACITY 2778 LBS. 4167 LBS. 5556 LBS. 6944 LBS. 8333 LBS. 9722 LBS. NOTE: UNIT WIDTHS WITH «. INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM, FOR TYPICAL PIERS SEE PAGE SU-01-0021 ar /O s e NOTES: AN ALTERNATE TO THE CONCRETE�Q•., EN APPRtP` �r . b y'�, r• Qy ....<rr �� DAPIA APPROVAL: SC-E I. PRE -FABRICATED PIER PADS MAY BE USED AS FOOTINGS SPECIFIED IN THE JACOBSEN HOMES SET-UP MANUAL. G�glj�fj�'•. � �� - rY ) �� i�O O •• 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE A ;• 9103 APPROVED BY MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM _ PIER CAPACITIES SHOWN ABOVE. 3. ALL OTHER REQUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN zt STATE Of .: 4 •� M HOMES INSTALLATION INSTRUCTIONS. 4. MAX. PIER SPACING 8' FOR UNITS WITH 8' I -BEAMS / 10' FOR UNITS WITH 10. OR.12' . I -BEAMS (24• MAX. FROM ENDS). "' � AEf DERALMANUFACTUREDHOVE 'DATE: T ❑ ❑❑ JACOBSEN HOMES THESE SPECIFlCATIONS AND DRAwwGS ARREE C �+ BY: D.M.T. 09-22-01 REV. LETTER: DRAWING TITLE: PRE-FAB. 18• X 22• & 20• PIER PAD SPACING ;❑ P.O. BOX 368 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE DRAWING NUMBER: SU-01-0024 SAFEPHONE(8 3) FLORIDA /1384695 PURPOSES FRDM o OTHERS. NEPPTT C+DNFFIDENTTx AND 17 3/16" X 25 3,/16" PIER FOOTER SPACINGS* (MIN. '432 7/8 SQ. IN). MAXIMUM I -BEAM PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR- 70 1/2" 110 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 144" WIDE FLOOR** 59 1/2" 93 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 160" WIDE FLOOR. 54" 85" 116" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 184" WIDE FLOOR- 47 1/2" 75" 102" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 - MIN. PIER CAPACITY 3004 LBS. 4507 LBS. 6009 LBS. 7511 LBS. 9013 LBS. 10,516 LBS. 24" X 24" PIER FOOTER SPACINGS* (MIN. 576 SQ.IN) MAXIMUM I -BEAM , PIER SPACING FLOOR MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) WIDTH 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR.. 95 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 144" WIDE FLOOR. 81" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NONE #4 li 160" WIDE FLOOR. 74" 115" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOITE #4 184" WIDE FLOOR** 65" 101" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 MIN. PIER CAPACITY 4000 LBS 6000 LBS 8000 LBS. 10,000 LBS. 12,000 LBS. 14,000 LBS. NOTE: UNIT WIDTHS WITH • INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE SU-01-0021 I, NOTES: 1. PRE -FABRICATED PIER PADS MAY BE USED AS AN ALTERNATE TO THE CONCRETE EN P OV :• • .fijy � '!F 1` G . G • 1 No. DAPIA APPROVAL: FOOTINGS SPECIFIED IN THE JACOBSEN HOMES SET-UP MANUAL. o =rY - 14• 03' 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE PPROVED BY MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM "� PIER CAPACITIES SHOWN ABOVE. 'd '. STATE r�" �+ n Q♦�T 1 i 3. ALL OTHER REQUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN e �' °�''•' HOMES INSTALLATION INSTRUCTIONS. 4. MAX. PIER SPACING 8' FOR UNITS WITH 8" I -BEAMS / 10' FOR UNITS WITH 10" OR 1 rya .�,�• .. ��c�:•.�,.. INC. 12' I MAX. FROM S -BEAMS (24" ENDS). le � EDERAL MANUFACTURED HOh1E, ARPS HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: 1/ D.M.T• ATE: 09-22-01 REV. LETTER: L10101:1101EF-111JACOBSEN SAFETY P.OBOX 368INC. HARBOR, FLORIDA 34695 ORIGINAL• PROPRIETARY, AND CONFIDENIIAL MATERIALS OF JACOBSEN MANUFACTURING SUCH MATERIALS ARE PRONDED TO THE RECIPIENT FOR SPECI IC PURPOSES DRAWING TITLE: PRE-FAB. 17 X 25 & 24" PIER PAD SPACING DRAWING NUMBER: SU-01-0025 PHONE (813) 726-1138 AND MUST BE KEPT CONFlDENTIAL AND SECRET FROM OTHERS 26" X 26" PIER FOOTER SPACINGS* (MIN: 676 SQ.IN) MAXIMUM I —BEAM PIER SPACING FLOOR WIDTH MAXIMUM PIER SPACING (SOIL BEARING CAPACITY) 1000 (PSF) 1500 (PSF) 2000 (PSF) 2500 (PSF) 3000 (PSF) 3500 (PSF) 120" WIDE FLOOR-- 113 1/2" SEE NOTE g4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE y4 144" WIDE FLOOR** 96 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 160" WIDE FLOOR. 87 1/2" SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 SEE NOTE #4 • 184" WIDE FLOOR** 77" 1 119 1/2" 1 SEE NOTE #4 SEE NOTE #4 SEE NOTE q4 SEE NOTE #4 IN. PIER CAPACITY 4694 LBS. 7042 LBS. 9389 LBS. 11.736 LBS. 14,083 LBS. 16.431 NOTE: UNIT WIDTHS WITH rr INCLUDES A 6" OVERHANG ON BOTH SIDES MAXIMUM. FOR TYPICAL PIERS SEE PAGE SU-01-0021 1 PRE -FABRICATED PIER PADS MAY BE USED AS AN ALTERNATE TO THE CONCRETE FOOTINGS SPECIFIED IN THE JACOBSEN HOMES SET-UP MANUAL. 2. THE PRE -FABRICATED PIER PADS ARE TO BE INSTALLED PER THE MANUFACTURERS INSTALLATION INSTRUCTIONS AND MEET THE MINIMUM PIER CAPACITIES SHOWN ABOVE. 3. ALL OTHER REQUIREMENTS ARE TO BE ADHERED TO AS SPECIFIED IN THE JACOBSEN HOMES INSTALLATION INSTRUCTIONS. 4. MAX. PIER SPACING 8' FOR UNITS WITH 8' I -BEAMS / 10' FOR UNITS WITH 10' OR Il 12' I -BEAMS (24" MAX. FROM ENDS). .;�(R &I!d:,/ %W/a o �,r •''GIST F: jq No � 9103- )AP A APPROVAL: If,09EL' csttc• P&--1 c- -APPROVED BY r0 OCT I I il INC. JACOBSEN HOMES THESE SPECIFICATi NS' N0 DRAINNGS ARE D.M.T. 09-22-01 ■ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: P.O. 80x 368 MATERIALS OF JACOBSEN MANUFACTURING PRE-FAB. 26" PIER PAD SPACING „ INC. SUCH MATERIALS ARE PROVIDED TO THE SAFETY HARBOR, FLORIDA 34695 REOPIENT FOR SPECIM PURPOSES AND MUST BE DRAWING NUMBER: PHONE (813) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS. SU-01-0026 PIER FOOTER SIZING CHART FOR MARRIAGE WALL OPENINGS (FOR SIDEWALL OPENINGS SEE NOTE O3 ) LOAD SPANS SOIL BEARING 8'=12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' CAPACITY PSF w Q 1000 390 sq. in. 494 sq. in. 597 sq. in. 701 sq. in. 805 sq. in. 908 sq. in. 1500 260 sq. in. 329 sq. in. 398 sq. in. 467 sq. in. 536 sq. in. 606 sq. in. 2000 195 sq. in. 247 sq. in. 299 sq. in. 351 sq. in. 402 sq. in. 454 sq. in. CQ 2500 156 sq. in. 197 sq. in. 239 sq. in. 280 sq. in. 322 sq. in. 363 sq. in. MIN. PIER CAP. 27081bs. 34281bs. 41481bs. 48681bs. 55881bs. 63081bs. LOAD SPANS w SOIL BEARING 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' A CAPACITY PSF 1000 409 sq. in. 519 sq. in. 628 sq. in. 737 sq. in. 847 sq. in. 956 sq. in. 1500 273 sq. in. 346 sq. in. 419 sq. in. 492 sq. in. 565 sq. in. 638 sq. in. `t 2000 205 sq. in. 259 sq. in. 314 sq. in. 369 sq. in. 423 sq. in. 478 sq. in LO 2500 164 sq. in. 207 sq. in. 251 sq. in. 295 sq. in. 339 sq. in. 383 sq. in CQ MIN. PIER CAP. 2841 Ibs. 3601 lbs. 1 4361 lbs. 1 5121 IDS. 5881 lbs. 6641 lbs. LOAD SPANS O4 w SOIL BEARING 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' q CAPACITY PSF 1000 428 sq. in. 544 sq. in. 659 sq. in. 774 sq. in. 889 sq. in. 1004 sq. in. - 1500 286 sq. in. 362 sq. in 439 sq. in. 516 sq. in. 593 sq. in. 670 sq. in. C0 2000 214 sq. in. 272 sq. in. 329 sq. in. 387 sq. in. 445 sq. in. 502 sq. in. 2500 171 sq. in. 217 sq. in. 264 sq. in. 310 sq. in. 356 sq. in. 402 sq. in. C\2 MIN. PIER CAP. 2975lbs 3775lbs 4575lbs 5375lbs 61751bs 6975lbs LOAD SPANS w SOIL BEARING 8'-12' 12'-16' 16'-20' 20'-24' 24'-28' 28'-32' Q CAPACITY PSF 1000 486 sq. in. 618 sq. in. 751 sq. in. 883 sq. in. 1016 sq. in. 1148 sq. in. 1500 324 sq. in. 412 sq. in. 501 sq. in. 589 sq. in. 677 sq. in. 766 sq. in. m 2000 243 sq. in. 309 sq. in. 375 sq. in. 442 sq. in. 508 sq. in. 574 sq. in. O 2500 194 sq. in. 247 sq. in. 300 sq. in. 353 sq. in. 406 sq. in. 459 sq. in. MIN. PIER CAP. 3375lbs 4295lbs 5215lbs 6135lbs 7055lbs 7975lbs NOTES: REF. CALCS. Qi SEE DETAIL 'El'. PACE SU-01-0001 FOR BLOCKING AND ANCHORING OF MARRIAGE WALL 11111t1 OPENINGS WADER THAN 49 INCHES. ENGINEkj N P o. T11 SEE NOTES: Q2 , (1 , AND ® UNDER TABLE I, PACE SU-01-0040. �� ••. "'F� Q3 FOR ALL UNIT WIDTHS USE 177 sq/'in PIER FOOTER UNDER SIDEWALL OPENINGS THAT ARE 49 INCHES TO 96 INCHES WIDE FOR OPENINGS THAT ARE 96 INCHES TO 144 No. INCHES, USE 242 sq/inPIER FOOTER UNDER SIDEWALL OPENINGS. 910334 (MIN. 1000 PSF SOIL BEARING REO'D) 0 FOR PROPER LOAD SPANS. SEE SU-03-0001. ('LOAD SPANS' ARE CLEARSPANS; PIER SPECIFICATIONS ABOVE ASSUME CLEARSPAN OCCURS ON ONE SIDE OF PIER ONLY - IF CLEARSPAN OCCURS ON BOTH SIDES, ADD VALUES LISTED ABOVE FOR EACH CLEARSPAN) - '0 '. TATE OF , Q5 CHECK WITH LOCAL JURISDICTION TO DETERMINE THE SOIL VALUE ON YOUR SITE OR HAVE A SOIL BEARING TEST PERFORMED CN YOUR SOIL TO DETERMINE THE VALUE. DAPIA VJINDZONE III (110 MPH) ALL EXPOSLI 20 PSE ROO 10 PSFI ,D.L. APPROVED BY IN INC. FEDERAL MANUFACTURED HOME CONsTRUCTIONAND SAFETY STANDAROS MAR 0 1 19K r ❑❑❑❑ JACOBSEN HOMES NOTICE: "fill THESE SPEancATIONS AND DRAWIGS ARE mam'nr: B.E.M. VAIL: 2-6-99 MV. LL IItK: 00 P.O. BOX 368 ORIGINAL. PROPRIETARY, AND COIF1DENNAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE: PIER FOOTER SIZING CHART /� O INC. SUCH MATERIALS ARE PROVIDED TO THE FOR MARR. WALL OPENINGS /� SAFETY HARBOR, FLORIDA 34695 LANµD 'o'sTHM DRAWING NUMBER ❑ PHONE (727) 726-1138 �TCOMME TI FR FROM SB-0I-0030 TABLE I PIER FOOTER SIZING AND PIER SPACING CHART (SEE NOTES BELOW) 12-WIDE WIDTH MAXIMUM 01 O5 PIER SPACING SOIL BEARING PSF CAPACITY O2 © REQUIRED PIER FOOTER AREA, SQ. IN. 3'-0" MAXIMUM FROM EACH END 1000 655 AND 8'-0" ON CENTER MAXIMUM 1500 437 (MINIMUM PIER CAPACITY 4548#) 2000 327 2500 262 4'-0" MAXIMUM FROM EACH END 1000 808 AND 10'-0" ON CENTER MAXIMUM 1500 538 (MINIMUM PIER CAPACITY 5608#) 2000 404 2500 323 13'-4"-WIDE WIDTH MAXIMUM &Q PIER SPACING SOIL BEARING PSF CAPACITY © REQUIRED PIER FOOTER AREA, SQ. IN. S-O" MAXIMUM FROM EACH END 1000 716 AND 8'-0" ON CENTER MAXIMUM 1500 478 (MINIMUM PIER CAPACITY 5014#) 2000 358 2500 287 4'-0" MAXIMUM FROM EACH END 1000 884 AND 10'-0' ON CENTER MAXIMUM 1500 590 (MINIMUM PIER CAPACITY 6191#) 2000 442 2500 354 15'-4"-WIDE WIDTH MAXIMUM 05 PIER SPACING SOIL BEARING PSF CAPACITY Q2 © REQUIRED PIER FOOTER AREA, SQ. IN. 3'-0" MAXIMUM FROM EACH END 1000 807 AND 8'-0" ON CENTER MAXIMUM 1500 539 (MINIMUM PIER CAPACITY 5615#) 2000 404 2500 323 4'-0" MAXIMUM FROM EACH END 1000 1000 AND 10'-0" ON CENTER MAXIMUM 1500 666 (MINIMUM PIER CAPACITY 6941#) 2000 500 2500 400 ON MULTIPLE SECTION HOUSES, CHECK EACH SECTION INDIVIDUALLY. UNDISTURBED SOIL OR 90% COMPACTION FOR FILL. ALL FOOTERS TO BE BELOW FROST LINE. MORE THAN ONE PIER MAY BE USED TO ACHIEVE THE MINIMUM SQUARE INCHES REQUIRED. ALL UNIT WIDTHS TO INCLUDE 6" SIDE OVERHANG ONE SIDE OR ONE 3" OVERHANG ON EACH, SIDE MAXIMUM. CHECK WITH LOCAL JURISDICTION TO DETERMINE THE SOIL VALUE ON YOUR SITE OR HAVE A SOIL BEARING TEST PERFORMED ON YOUR SOIL TO DETERMINE THE VALUE. CALCS. 02 �PQ GIST ERF . Ile. No. o 910334 %TATF of :W ALL ZONES ALL EXPOSURES 20 PSF ROOF 10 PSF D.L. APPROVED BY Nil "[I INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STIMNDAROS MAR 0 1 ig9g NOTICE"' "���� �VLETTER: JACOBSEN HOMES THESE sPEGIECAna+S AND ORawNsS ARE M.T. 2-8-99 ORIGINAL. PROPRIETARY. AND COEFTDENTIAL DRAWING TITLE: A, fig P.O. BOX 368 MATERIALS OF IACOOSEN MANUFACTURING PIER FOOTER SPECS CHART Dr- SUCH MA710ALS ARE PRONGED TO THE SAFETY HARBOR, FLORIDA 34695 RECFIENT FOR SPEOFIC MWOSES AND WJST BE DRAWING NUMBER - PHONE (727) 726-1138 KEPT CONROEI ML AND SECRET FROM OniI6 I SU-01-0040 v MOBILE HOME SET-UP DIM. 'A' I DIM. 'B' MN #1 COLUMN #2 COLUMN #3 COLUMN SUPPORT SPANS TO PROPERLY SIZE PIERS LOCATED AT RIDGE BEAM SUPPORT COLUMNS, SURVEY THE ARRANGEMENT OF THE ROOMS IN THE MOBILE HOME TO LOCATE THE OPENINGS ALONG THE MARRIAGE WALL OF THE HOME. MEASURE EACH OPENING IN THE MARRIAGE WALL PAYING ATTENTION PARTICULARLY TO OPENINGS GREATER THAN 4 FEET WIDE. IN THE EXAMPLE ABOVE TO DETERMINE THE SPAN FOR COLUMN #1 SIMPLY USE DIMENSION 'A'. TO DETERMINE THE SPAN FOR COLUMN #2 ADD DIMENSION 'A' AND DIMENSION 'B' TOGETHER. THE SPAN FOR COLUMN #3 CAN BE DETERMINED THE SAME WAY AS COLUMN #1 SIMPLY USE DIMENSION 'B'. ONCE THE COLUMN SPANS HAVE BEEN DETERMINED, FIND THE CORRESPONDING PIER FOOTING SIZE IN THE CHART (SU-01-0030). ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: S.A. I DATE: 6-6-94 REV. LETTER: ❑.❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE- COLUMN SUPPORT SPANS „❑ HEI P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE ❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-03-0001 (727) CLOSE-UP NOTES DURING SET-UP ALL SEAMS BETWEEN FRAMING MEMBERS ON THE FLOORS AND EXTERIOR WALLS OF MULTIPLE WIDE UNITS MUST BE SEALED. THIS SHALL BE ACCOMPLISHED BY ANY OF THE FOLLOWING METHODS: 1. BLACK FABRIC TAPE ADHEARED TO BOTH SECTIONS BEFORE APPLING THE ON -SITE FINISH MATERIALS. 2. FOILCORE OR THERMO-PLY STRIPS (2" WIDE MIN.) FASTENED TO BOTH SECTIONS W/ MIN. 7/16" X 5/8" X 16 GA. STAPLES 6" O.C. MAX. SPACING (APPLIED BEFORE ON -SITE FINISH MATERIALS). 3. SMALLER GAPS APPROX. 1/4" WIDE MAY BE SEALED WITH A BEAD OF LATEX CAULK (OR EQUAL). BEFORE SETTING MULTIPLE WIDE UNITS THE CLOSE-UP PLASTIC SHIPPING MATERIAL MUST BE REMOVED FROM ALL EXTERIOR WALLS OF ALL SECTIONS. THE SHIPPING PLASTIC MAY BE LEFT IN PLACE ON ALL MATING OR MARRIAGE WALLS OF EACH SECTION, BUT THE PANEL STRIPPING MATERIAL OUTSIDE THE CLOSE-UP SHIPPING PLASTIC MUST BE REMOVED TO ALLOW THE MULTIPLE WIDE SECTIONS TO BE BROUGHT TOGETHER WITH MINIMUM GAPPING BETWEEN THE SECTIONS. AFTER THE UNITS ARE PLACED TOGETHER THE CLOSE-UP PLASTIC MATERIAL LEFT ON THE MARRIAGE WALLS MAY BE CUT-OUT AT ALL OPENINGS THROUGH THE MATING WALLS TO OTHER MULTIPLE WIDE SECTIONS. AFTER REMOVAL OF THE GALVANIZED WIND DEFLECTOR LOCATED ON THE ROOF AT THE HITCH END OF EACH UNIT OF THE HOME. ANY PENETRATIONS OF THE ROOF SHINGLES MUST BE SEALED WITH A ROOFING CEMENT OR OTHER SUITABLE MATERIAL. ALL CEILING FAN PREPS AND/OR FIXTURE PREPS LOCATED ON THE MATING LINE OF MULTIPLE WIDE UNITS MUST BE TEMPORARILY REMOVED FOR THE SET-UP OF THE HOME. WHEN REINSTALLING THE PREPS (ELECTRICAL BOXES) A FIXTURE FLASHING RING MUST BE INSTALLED BETWEEN THE FINISH MATERIAL (CEILING BOARD AND/OR PANELING) AND THE ELECTRICAL BOX. THE FIXTURE FLASHING RING IS PROVIDED WITH THE HOME (SHIPPED WITH THE SET-UP KIT) AND MUST BE INSTALLED DURING THE SET-UP OF THE HOME. THE FIXTURE FLASHING RING IS REQUIRED TO PROTECT THE FINISH MATERIAL FROM POSSIBLE FIRE HAZARDS FROM ELECTRICAL SHORTS OR EXCESSIVE HEAT BUILDUP FROM THE ELECTRICAL SYSTEM. THE FIXTURE FLASHING RING CAN BE IDENTIFIED AS THE THIN WHITE FIBROUS DONUT LOOKING RING IN THE SET-UP KIT. NOTE: BEFORE INSTALLING A CEILING FAN INSTALL A 4 CU. IN. MIN. BOX EXTENSION. (CHECK FACTORY INSTALLED CEILING BOX FOR LABELING INDICATING SUITABLE FOR DIRECT ATTACHMENT OF CEILING FAN FIXTURE -IF NOT LABELED AS BEING SUITABLE, YOU MUST INSTALL A HOOK TYPE CEILING FAN -INSTALL HOOK THROUGH BOX INTO LUMBER BACKER BEHIND FAN BOX.) THE SAFETY CHAIN FOR ALL EXTERIOR OUTSWING DOORS SHALL BE INCLUDED IN THE SET-UP KIT. THE SAFETY CHAIN SHALL BE INSTALLED WHEN THE HOME IS SET-UP. INSTALL THE SAFETY CHAIN PER THE MANUFACTURERS SPECIFICATIONS INCLUDED WITH THE SAFETY CHAIN HARDWARE. FASTEN ALL EXTERIOR SIDING IN THE HORIZ. DIRECTION W/ MIN. 7/16" x 1" x 16 GA. STAPLES 16" O.C. MAXIMUM THROUGH SHEATHING INTO STUD, FASTEN ALL EXTERIOR TRIM W/MIN. 7/16 x 5/8" x 16 GA. STAPLES AT 6" O.C. MAXIMUM. NOTICE: DRAWN BY: S.A. DATE: 12-22-94 REV. LETTER: ❑❑❑❑JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWNGS ARE ❑❑�❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE: CLOSE-UP NOTES _ P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO THE H SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE OTHERS. DRAWING NUMBER: SU-05-001 ❑❑❑ PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM EXTERIOR ROOFING CLOSE-UP RIDGE SHINGLES OR TABS CUT FROM THREE —TAB SHINGLES FURNISHED IN THE SET—UP MATERIALS APPLIED OVER COMPLETED SHINGLE ROOFING I (INSTALL RIDGE SHINGGES PER I I MANUFACTUERS INSTALLATION INSTRUCTIONS.) �I I I� I I I I I I 'uln. ♦ I ryllli. � 'llll,. I �IIII�. 'llll'. .'uw. •�Ipp. illlli. ..I,IL. I nlll,,. nw "ryll' "IIII' �Alll�' •iIIIW � .illry. +III +ryln � uln � Ilry, 4III. i .,Iry,. — COMPLETE SHINGLE ROOFING BY INSERTING FINISHING COURSE(S) OF SHINGLES TO EXISTING SHINGLES INSTALLED AT THE FACTORY. LIFT THE UPPER ROW OF SHINGLES AT THE TABS TO INSERT FINAL COURSE OF SHINGLES AND FOLLOW THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS FOR FASTENING. (THIS APPLICATION FOR TRIPPLE WIDES ONLY) NOTES: 1. RIDGE SHINGLES ARE FACTORY APPLIED ON TRIPPLE WIDE HOMES, AND MUST BE APPLIED DURING SET—UP FOR DOUBLE WIDE HOMES. - COMPLETE SHINGLE ROOF BY ADDING FINISHING COURSE(S) TO SHINGLES INSTALLED IN THE FACTORY. ALLOW TOP END OF TOP ROW OF SHINGLES TO EXTEND ACROSS RIDGE ONTO OPPOSING SECTION OF MULTIPLE WIDES. (SEE SU-05-0011 FOR SHINGLE FASTENING REQUIREMENTS.) JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARES.A. DRAWN BY: DATE: 6-6-94❑■❑ORIGINAL, REV. LETTER: PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: „❑ 101--lo P.O. BOX 368 MATERIALS OF JAC03SEN MANUFACTURING INC. SUCH MATERIALS ARE PRONDED TO THE EXTERIOR ROOFING CLOSE-UP SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-05-001 O 0 SHINGLE INSTALLATION 6 ROOF SHEATHING (TYP.) SHINGLE UNDERLAYMENT •atln. FIBERGLASS SHINGLES u .illll,. 'ry4� +ryll. +ilry,. .,Iryl. .tlllli. "ryll� +Ilg. +UI, nllll�. •�ulN +aN. TYPICAL ROOF TRUSSES 16" ON CENTER 1 /2" 1 /2" 1/2" TO 31, TO 3„ 1/2„ METAL DRIP EDGE TO 1 1 /2" A A TO 1 1 /2" r � owlr lrws me,, mGm� D ro v7 co PAGE RC-19-0002 OTES: 1. SHINGLES FASTENED W/ MIN. 1° X 3/4" X 16 GA. STAPLES AS SHOWN IN THE SHINGLE FASTENING DETAIL. IF A STAPLE IS OVER —DRIVEN, PROPERLY INSTALL ANOTHER STAPLE RIGHT OR LEFT OF OVER —DRIVEN STAPLE AND SEAL OVER —DRIVEN STAPLE WITH ROOFING CEMENT. 2 WHEN METAL DRIP EDGE IS INSTALLED, IT IS NOT NECESSARY FOR SHINGLES TO OVERHANG THE RAKE (FRONT & REAR) EDGE OF THE ROOF. 3. SHINGLE UNDERLAYMENT FASTENED TO DECKING W/ MIN. 3/8" X 3/4° X 18 GA. STAPLES MIN. (TACKED DOWN UNTIL SHINGLES ARE APPLIED). 4.METAL DRIP EDGE FASTENED TO DECKING W/ MIN. 3/8" X 3/4" X 18 GA. STAPLES 12" O.C. MAXIMUM. 5. SHINGLE ROOF COVERINGS WHICH ARE SECURED W/ 6 FASTENERS PER SHINGLE THROUGH AN UNDERLAYMENT WHICH IS CEMENTED DOWN TO 3/8" STRUCTURAL RATED ROOF SHEATHING NEED NOT BE EVALUATED FOR DESIGN WIND PRESSURES. FASTENING DETAIL NOTE: SHINGLES INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS ONLY WHEN SPECIFIC APPLICATIONS ARE NOT COVERED WITHIN THIS MANUAL. N ❑❑JACOBSEN HOMES 0❑VE] P.O. BOX 368, 901 4th ST. NORTH ❑❑ SAFETY HARBOR, FLA. 34695 PHONE (813) 726-1138 SHINGLE INSTALLATION © 6-6-94 REVISIONS: DATE: 12-21-94 SU-05-0011 EXTERIOR FINISH CLOSE-UP SOFFIT AND FASCIA APPLICATION DETAIL METAL DRIP EDGE +� t _ - SOFFIT MATERIAL I FASCIA MATERIAL LAP RECEIVER (J CHANNEL) NOTES: 1. ALL MATERIALS REQUIRED FOR ON SITE COMPLETION OF THE LAP SIDING APPLICATION IS SHIPPED INSIDE THE HOME WITH THE SET—UP KIT. 2. FIRST LOCATE AND SECURE THE SOFFIT MATERIAL TO EACH SECTION OF THE HOME WITH EITHER STAPLES, NAILS, OR SHEET METAL SCREWS 6" O.C. 3. NEXT LOCATE AND SECURE THE FASCIA MATERIAL IN THE SAME MANNER AS LISTED ABOVE FOR THE SOFFIT. 4. THEN COMPLETE THE APPLICATION OF BOTH THE METAL DRIP EDGE AND THE LAP SIDING RECEIVER. 5. AFTER ALL PARTS HAVE BEEN JOINED AT THE MATING EDGES OF EACH SECTION OF THE HOME, BEGIN WITH THE LAP SIDING APPLICATION. START THE LAP SIDING APPLICATION AT THE BOTTOM OF THE HOME AS SHOWN IN THE LAP SIDING APPLICATION DETAIL BELOW. ALL TRIM AROUND OPENINGS (ie. WINDOWS AND DOORS) IS COMPLETED BEFORE THE HOME IS SHIPPED. LEAVE AMPLE ROOM AT ALL TRIM FOR THE LAP SIDING TO EXPAND AND CONTRACT WITH TEMPERATURE CHANGES. FOR ANY .ADDITIONAL INFORMATION REQUIRED SEE THE MANUFACTURERS INSTALLATION INSTRUCTIONS PLACED INSIDE THE SET—UP KIT SHIPPED WITH THE HOME. LAP SIDING FASTENING: 1. SECURE HORIZ. LAP SIDING W/ MIN. 7/16" X 1" X 16 GA. STAPLES 16" 0. C. MAXIMUM THROUGH SHEATHING INTO STUD. SECURE ALL EXTERIOR TRIM W/ MIN. 7/16" x 5/8" x 16 GA. STAPLES AT 6" 0. C. MAXIMUM. 2. WITH METAL LAP STAPLE CROWNS MAY BE EITHER PARALLEL OR PERPENDICULAR TO NAILING FLANGE WITH BOTH LEGS OF STAPLE PENETRATING THE NAILING FLANGE. 3. WITH VINYL SIDING STAPLE CROWNS TO BE PERPENDICULAR TO NAILING FLANGE WITH ONE LEG CENTERED IN SLOT AND OTHER LEG ON OUTSIDE OF NAILING FLANGE WITH APPROX. 1/32" SPACE BETWEEN STAPLE CROWN AND NAILING FLANGE. 4. ALL FASTENERS TO BE WEATHER RESISTANT. BOTTOM STARTER STRIP HOOK STARTER LAP ON STARTER STRIP LAP SIDING APPLICATION DETAIL ❑❑ ❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: S.A. DATE: 12-22-94 REV. LETTER: DRAWING TITLE: EXTERIOR FINISH CLOSE-UP ❑❑■❑ ❑,.❑ P.O. BOX 368 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND,MUST BE FROWOTHERS. DRAWING NUMBER: PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET SU-05-0020 MOBILE HOME SET-UP/CLOSE-UP SITE INSTALLED EXTERIOR SIDING APPLICATION SEE OTHER DETAILS (SU-05-0031 THRU 0034) FOR PLAN VIEW DETAILS IDENTIFING AREAS REQUIRING EXTERIOR SIDING TO BE SITE INSTALLED. SEE SU-05-0020 FOR LAP SIDING FASTENING, AND SOFFIT AND FASCIA APPLICATION. ALL AREAS WHERE THE EXTERIOR SIDING MATERIALS EXTEND ACROSS THE MATING LINE BETWEEN MULTIPLE WIDE UNITS ARE REQUIRED TO BE FINISHED ON SITE TO PREVENT A CONTINUOUS SEAM IN THE EXTERIOR SIDING LOCATED AT THE MATING LINE(S) OF THE HOME. ALL TRIM AND EXTERIOR SIDING MATERIALS ARE PROVIDED IN THE HOME SET—UP KIT FOR COMPLETION OF ALL EXTERIOR SIDING APPLICATIONS FOR THE HOME. THE STARTER STRIP FOR THE LAP SIDING APPLICATION IS INSTALLED AT THE FACTORY TO ENSURE STRAIGHT ALIGNED APPLICATION OF THE SIDING. ALL TRIM MATERIALS NOT REQUIRING FASTENING TO MORE THAN ONE SECTION OF MULTIPLE SECTION HOMES IS ALSO FACTORY INSTALLED TO ENSURE PROPER CLEARANCES AND AN ASSURED MATCH TO THE REMAINDER OF THE HOME. ALL TRIM MATERIALS SECURED TO MORE THAN ONE SECTION OF THE HOME ARE TO BE FASTENED TO THE WALL FRAMING MEMBERS WITH MIN. 7/16" X 5/8" X 16 GA. STAPLES OR 1° ROOFING NAILS 6" O.C. MAXIMUM. TAKE CARE IN LOCATING TRIM MATERIALS TO ENSURE PROPER ALIGNMENT WITH THE FACTORY INSTALLED MATERIALS. ALL FASTENERS USED MUST BE WEATHER RESISTANT TO INSURE DURIBILITY. ENCLOSED WITH THE EXTERIOR SIDING MATERIALS ARE THE MANUFACTURERS INSTALLATION INSTRUCTIONS DETAILING THE RECOMENDED INSTALLATION PROCEDURES AND SPECIFICATIONS FOR THE TYPE OF SIDING BEING USED ON THE HOME. CAREFULLY EXAMINE THE MANUFACTURERS INSTALLATION INSTRUCTIONS BEFORE ANY ATTEMPT TO COMPLETE THE REQUIRED INSTALLATION OF THE EXTERIOR SIDING MATERIALS. SHOULD FOR ANY REASON THE MANUFACTURERS INSTALLATION INSTRUCTIONS BE LOST OR MISSING, CONTACT JACOBSEN HOMES AT 901 4th Street North Safety Harbor, Florida 34695 OR CALL (727) 726-1138 FOR REQUESTING THE INSTALLATION INSTRUCTIONS. ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: ❑❑■❑ ❑„❑ ❑❑❑❑ P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING TITLE: EXTERIOR SIDING APPLICATION � DRAWING NUMBER: SU-05-0030 MOBILE HOME SET-UP/CLOSE-UP SITE INSTALLED EXTERIOR SIDING APPLICATION (FOR SLIP UNIT MULTIPLE WIDES) I MATING LINE OF UNITS I I SITE INSTALLED EXTERIOR SIDING I I MATING LINE OF UNITS I SITE INSTALLED INS[[ CORNER POST SITE INSTALLED EXTERIOR SIDING NOTICE: DRAWN BY: DATE: REV. LETTER: ❑❑❑❑ JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWINGS ARE S.A. I 6-6-94 ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: ❑„❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROWDED TO THE EXT.SID.APPL. FOR SLIP UNIT ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. ` DRAWING NUMBER: SU-05-0031 (727) ONrP INC. FM ft"m ca MOIL �LL�TI OlJ lu,.zy�4yi�:yi.s+v►n�� �D� (01D.Gc chyJ7 s I �. �S�� L. 00 000 TH � i-i��� xylcl�,tzcrtfJ x ► �.� `�-� ei infra S1f - o $ - 0 O 2. tarrN I � Ur�XYi �nx r l�iu hrAj�L•5�j Ci G.G. � :;�i � ���'. - WED -. Z�7NE 2 6Nb .3 d°'I c- 71Wq br PY= kola fiG&Lr=: i'ti°G-VINYLr 51D�j INSrx1..l4�C�I Db•un- Qa- V-(,.(-. L1. k�.k_kTY�ioL•. Y 0 APPROVED BY JUL 1 3 IM 7N r;l N C FCMft �Fxj �FICR J1AL-J- ��I►�l� r�G►. ��.ij=1�D _ (060az PLY) *(IJPS la TH l(o -.1-A 3,710"0..0. OR a.L , Is I v� t�+ -0033 71J1.tr= 2 bt.lb y�i.s: N�'S Z..•v. j7't'=�'�11d1'I� SIDr].t(,j'INSr?,LL.hPOrL k7A-LL. I h - MOBILE HOME SET-UP SHUTTER INSTALLATION: SHUTT IRS ARE NORMALLY FASTENED BY SCREWING DIRECTLY THROUGH THE VINYL SIDING. THIS TENDS TO RESTRICT SIDE -TO -SIDE MOVEMENT OF THE VINYL SIDING PANELS. HOWEVER, SEVERAL THINGS CAN BE DONE TO ELIMINATE BUCKLING OR OIL CANNING OF THE VINYL SIDING IN THESE AREAS: A. WHEN PANELS RUN FROM WINDOW AREA TO A CORNER POST OR OR J-CHANNEL (OR ANY TYP. VINYL SIDING TRIM) AT THE OPPOSITE END, BE SURE TO LEAVE PROPER CLEARANCE IN THE 'POCKET" - THEN SIDING WILL EXPAND TOTALLY IN THAT DIRECTION. B. TWO SHUTTERS BETWEEN WINDOWS: THE PANELS THAT WILL BE RESTRICTED BY THE SHUTTER SCREWS SHOULD BE SHORTER LENGTHS (SEAM BETWEEN WINDOWS - NOT ONE CONTINUOUS PIECE OF VINYL) - SIMPLY OVERLAP TWO PANELS IN THIS AREA. PANELS WILL THEN EXPAND TOWARD THE OVERLAP JOINT (SEE DETAIL "A"). OR STAGGER THE SHUTTER SCREWS - INSTALL FIRST SHUTTER, TAKE NOTE OF WHICH PANELS ARE RESTRICTED BY THE SCREWS. THEN INSTALL THE OPPOSITE SHUTTER, POSITION THE SCREWS FOR THIS SHUTTER THROUGH PANELS EITHER ABOVE OR BELOW THE PANELS RESTRICTED BY THE SCREWS FROM THE FIRST SHUTTER. BY DOING THIS THE PANELS OF VINYL SIDING WILL BE ABLE TO EXPAND IN AT LEAST ONE DIRECTION, SO LONG AS PROPER CLEARANCE HAS BEEN MAINTAINED IN THE "POCKET" AREA OF THE CHANNEL. (SEE DETAIL "B") DETAIL "B" DETAIL "A" ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: DRAW9NG TITLE: SHUTTER INSTALLATION ❑❑■❑ ❑„❑ P.O. BOX 368 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-05-0034 MOBILE HOME SET-UP TI wN THERE ARE TWO TYPES OF WIND THAT CAUSE DAMAGE: HORIZONTAL AND UPLIFT. YOUR HOME IS DESIGNED FOR THE HURRICANE ZONE (ZONE III). IF YOU FOLLOW OUR RECOMMENDATIONS YOU WILL PROTECT YOUR HOME FROM BOTH TYPES OF WIND FORCES. IN TIEING DOWN YOUR HOME, YOU MUST USE MATERIALS OF ADEQUATE STRENGTH AND SPECIFICATIONS. ANCHORING EQUIPMENT- (LOAD RESISTANCE) ANCHORING EQUIPMENT SHALL BE CAPABLE OF RESISTING AN ALLOWABLE WORKING LOAD EQUAL TO OR EXCEEDING 3.150 POUNDS AND SHALL BE CAPABLE OF WITHSTANDING A 50 PERCENT OVERLOAD (4.725 POUNDS TOTAL) WITHOUT FAILURE OF THE ANCHORING EQUIPMENT. ANCHORING EQUIPMENT- (WEATHERIZATION) ANCHORING EQUIPMENT (STRAPS, ETC...) EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIORATION AT LEAST EQUIVALENT TO THAT PROVIDED BY A COATING OF ZINC ON STEEL OF NOT LESS THAN 0.30 OUNCES PER SQUARE FOOT OF SURFACE COATED, AND IN ACCORDANCE WITH THE FOLLOWING: SLIT OR CUT EDGES OF ZINC -COATED STEEL STRAPPING NEED NOT BE ZINC COATED. TIE -DOWN STRAPS SHALL BE TYPE 1, FINISH B. GRADE 1 STEEL STRAPPING. 1. 1 /4 INCHES WIDE AND 0.035 INCHES IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL, AND SEALS. ANCHORING NOTE: THERE IS A TENDENCY FOR THE TOP OF THE ANCHOR ROD TO DEFLECT AND MOVE OR 'SLICE" THROUGH THE SOIL WHEN LOADED WITH THE FRAME TIE. THIS IS NOT DESIRABLE. SINCE IT PERMITS THE MOBILE HOME TO BE DISPLACED DOWNWIND AND TEND TO SLIDE OFF THE PIERS. TO MINIMIZE DEFLECTIONS. AUGER -TYPE AND OTHER ANCHORS USING STEEL RODS SHOULD BE PUT ON AT AN ANGLE SO THEY ARE MORE IN LINE WITH THE DIRECTION OF PULL. THIS CAN BEST BE ACCOMPLISHED BY INSTALLING THE ANCHORS PRIOR TO PLACEMENT OF THE MOBILE HOME ON THE LOT. IF VERTICAL ANCHORS ARE DESIRED, THE ANCHOR MUST BE LIS r-D FOR USE VERTICALLY AT THE CAPACITY REQUIRED FOR THE STRAPPING BEING ATTACHE. APPROVED BY ONJUL 1 3 INC. me ow as SANOTT APPOLI D TO TIE -DOWNS LTRAPS ON ONE Y ON OPPOSITE SIDE SIIDES.FTHEE OMEEMAYLY. BEI ON PULLED OFF THE SUPPORTS. ..�. 6-6-94 SU-07-000_1 MOBILE HOME SET-UP/ELECTRICAL ELECTRICAL CONNECTIONS BETWEEN HOME SECTIONS NOTE: NO ELECTRICAL POWER SHOULD BE CONNECTED TO HOMES WHILE MAKING ELECTRICAL CONNECTIONS. ALL ELECTRICAL WORK SHOULD BE DONE BY A QUALIFIED ELECTRICIAN. MATERIAL SUPPLIED 1. APPROPORATE NUMBER OF JUNCTION BOXES TO MAKE 2 CONNECTIONS PER JUNCTION BOX. (SHIPPED LOOSE IN THE SET-UP KIT) 2. WIRE NUTS. 3. JUNCTION BOX COVERS. INSTRUCTIONS A. SECURE JUNCTION BOXES UNDER HOME. B. WIRES HAVE BEEN COLOR CODED; SIMPLY MATCH UP COLOR CO-ORDINATED WIRES WITHIN A JUNCTION BOX AND CONNECT WITH WIRE NUTS. C. PLACE COVERS OVER JUNCTION BOXES. OMITTED CEILING FIXTURES FIXTURES TO BE INSTALLED AT THESE LOCATIONS MUST BE A TWO WIRE FIXTURE WITH GROUND. INSTALL ALL FIXTURES BEFORE TURNING ON MAIN BREAKERS. HOT LEADS (RED & BLACK) CONNECTED TO MAIN BREAKER NEUTRAL (WHITE) WIRE TO NEUTRAL BUSS NOTE: SEE BELOW NO. 6 BARE COPPER GROUNDING FOR SERVICE ELECTRODE CONDUCTOR BONDED TO CONDUCTOR NEUTRAL BUS IN SERVICE PANEL, EXTEND SIZES TO GROUNDING ELECTRODE PER NEC 250-83 MINIMUM CONDUIT SIZES:- CONDUIT DROP FROM HOME - EXTEND 1 1 /2" MINIMUM - 150 AMP TO BELOW GROUND LEVEL OR SEE 2" MINIMUM - 200 AMP LOCAL CODES TYPICAL ELECTRICAL CONNECTIONS CROSS -OVER CONNECTIONS CROSS -OVER INFORMATION APPLIES TO MULTI -SECTION UNITS CROSS -OVER WIRES ARE COLOR -CODED SERVICE CONDUCTORS MAIN BREAKER HOT NEUTRAL GROUND 150 (2) NO. 1 N0. 1 NO. 6 200 (2) NO. 2/0 NO. 2/0 NO. 6 NOTE: ABOVE SERVICE CONDUCTORS ARE FOR COPPER ONLY. FOR COPPER -CLAD ALUMINUM REFER TO LOCAL CODES ELECTRICAL PANEL LABEL THIS LABEL IS LOCATED ON OR NEAR THE ELECTRICAL PANEL THE MINIMUM SIZE JUNCTION BOX ATTACHED TO THE CONDUIT FOR SERVICE CONDUCTORS ARE: 9" X 9" X 4" - 150 AMP OR 12" X 12" X 4" - 200 AMP ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: D.M.T. DATE: 01-24-02 REV. LETTER: ❑❑■❑ P.O. 368 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE: SET-UP/ELECTRICAL n "� 60X INC. SUCH MATERIALS ARE PROVIDED TO THE //�,\ ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-09-0001 PHONE (727) 726-1138 _ ELECTRICAL CROSS -OVER i--MARRIAGE LINE I I . t NOTCHED MARRIAGE WALL PERIMETER JOISTS - .92" DEEP NOTCH MAX. ELECTRICAL WIRING FROM ONE SECTION TO BE HOOKED -UP IN JUNCTION BOX(S) ELECTRICAL JUNCTION BOX(S) FASTENED TO TRANSVERSE FLOOR JOIST. NOTE ALL GROUND LEADS ARE SECURED TOGETHER AND BONDED TO THE JUNCTION BOXES W/ THE LARGEST•SIZE CONDUCTOR IN BOX. (ALL REQUIRED JUNCTION BOXES ARE SHIPPED LOOSE IN THE SET-UP KIT) ALL ELECTRICAL WIRING CONNECTIONS TO BE MADE INSIDE LISTED JUNCTION BOX(S) IN COMPLIANCE WITH N.E.C. - 2005 WIRING IN LISTED JUNCTION BOX(S) NOT TO EXCEED CAPACITY OF THE JUNCTION. BOX(S) PER N.E.C. - 2005. WIRING TO BE PROTECTED AND SECURED AT MARRIAGE WALL JOISTS WITH WIRE PROTECTOR PLATES INCLUDED IN SET-UP KIT. ELECTRICAL CROSSOVER WIRING TO BE DONE ONLY BY QUALIFIED PERSONNEL. MATCHING IDENTIFIED CIRCUIT WIRING FROM EACH SECTION OF MULTIPLE WIDE HOMES. AFTER WIRING CONNECTIONS HAVE BEEN MADE, REPLACE COVER ON ,JUNCTION BOX(S), AND REPAIR ANY CUTS OR VOIDS IN THE. BOTTOM BOARD WITH DUCT' TAPE. APPROVED BY 0 N oloRevised p, May 25,2006 INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS NOM JACOBSEN HOMES � SFfCMXNS AND DRAADICS ARE A Bw M.T. I D 1-05-25-06 ■ MG► AI. PRCPPEiARY, mw D "LwiBa DRAW TIRE: YATEAIAIS OF JACOBSEN YANUFACTUPoNG B P.O. BOX FLORIDA INC. SDa UA�us ARE FrMIDED TO n ELECTRICAL CROSS -OVER PH )NEE HARBOR.81136--1138�95 WmaF o� � F of � DRAW SU-09-0010 MOBILE HOME SET-UP/ELECTRICAL I -BEAM WIRE FROM BREAKER BOX TO GROUNDING TERMINAL #8 BARE COPPER WIRE MINIMUM OUTRIGGER GROUNG WIRE MAY BE ATTATCHED TO ANY PART OF THE FRAME ASSEMBLY (NOT REQ'D TO BE ® OUTRIGGER). ANY APPROVED GROUNDING TERMINAL SECURED TO FRAME TO INSURE PROPER GROUND (METAL TO METAL CONTACT INSURED BY USING A STAR WASHER BETWEEN OUTRIGGER AND TERMINAL). TYPICAL ELECTRICAL GROUND NOTE: ALL EXPOSED NONCURRENT CARRYING METAL PARTS THAT MAY BECOME ENERGIZED SHALL BE EFFECTIVELY BONDED TO THE GROUNDING TERMINAL OR ENCLOSURE OF THE DISTRIBUTION PANELBOARD. A BONDING CONDUCTOR SHALL BE CONNECTED BETWEEN EACH DISTRIBUTION PANELBOARD AND AN ACCESSIBLE TERMINAL ON THE CHASSIS. NO. 8 BARE COPPER ---'- �-APPROVED GROUNDING TERMINAL BOND WIRE (MINIMUM) ATTACHED TO OUTRIGGER OR I -BEAM (TYPICAL EACH UNIT). TYPICAL ELECTRICAL BONDING GROUNDING AND CONTINUITY TEST THE GROUNDING CONTINUITY TEST MUST BE PERFORMED BEFORE THE FEEDER CONDUCTORS ARE CONIECTED. PERFORM THE FOLLOWING TEST AFTER ALL STRUCTURAL ASSEMBLY, METAL AND TRIM INSTALLATION IS FINISHED: A. CONNECT ONE CLIP OF A FLASHLIGHT CONTINUITY TESTER TO A CONVENIENT GROUND (METAL SKIN, WINDOW FRAME ON METAL SKINNED UNITS, FLOOR DUCT RISER, SCREW HEAD ON RECEPTACLE OR SWITCH PLATE, ETC.) AND TOUCH THE OTHER CLIP TO EACH LIGHT FIXTURE CANOPY (WHERE LIGHT IS MOUNTED TO CEILING OR WALL). THE CONTINUITY TESTER SHOULD LIGHT IF EACH FIXTURE IS PROPERLY GROUNDED. B. REPEAT THESE PROCEDURES FOR ALL DIRECT WIRED APPLIANCES AND FIXTURES. C. USING THE SAME PROCEDURES, CHECK THE CONTINUITY BETWEEN THE FOLLOWING: 1. BETWEEN METAL ROOF AND STEEL FRAME. 2. BETWEEN METAL SKIN AND STEEL FRAME. 3. BETWEEN STEEL FRAME AND GAS PIPING. D. ANY LOSS OF GROUNDING CONTINUITY FOUND IN THE ABOVE WILL REQUIRE INVESTIGATION, CORRECTION, AND RETESTING FOR CONTINUITY.. ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: S.A. I DATE: 6-6-94 REV. LETTER: �Eltll= P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROIADED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING TITLE: TYPICAL ELECTRICAL GROUND DRAWING NUMBER: SU-09-0020 EXTERIOR LIGHT FIXTURE INSTALLATION BE SURE ELECTRICAL SERVICE IS DISCONNECTED BEFORE COMING IN CONTACT WITH ELECTRICAL CONDUCTORS FIXTURE FLASHING RING (THIN WHITE FIBROUS RING) WHITE (NEUTRAL) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER AND SECURED WITH WIRE NUT BLACK (HOT) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER AND SECURED WITH WIRE NUT 0 EXTERIOR ELECTRICAL BOX BARE (GROUND) WIRING FROM FIXTURE AND BOX TWISTED TOGETHER AND SECURED WITH WIRE NUT EXTERIOR LIGHT FIXTURE (LISTED FOR EXTERIOR USE) BEFORE ELECTRICAL SERVICE IS CONNECTED TO THE HOME, INSPECT THE EXTERIOR OF THE HOME AND LOCATE ALL THE EXTERIOR LIGHT LOCATIONS TO BE INSTALLED ON SITE. (ALL EXTERIOR LIGHT FIXTURES IN PORCH AND OTHER AREAS NOT ALONG THE EXTERIOR WALL AREAS OF THE HOME ARE INSTALLED AT THE FACTORY). THE EXTERIOR LIGHT LOCATIONS CAN BE IDENTIFIED AS EXTERIOR ELECTRICAL BOXES IN THE WALLS USUALLY LOCATED ADJACENT TO EXTERIOR DOORS THAT ARE COVERED WITH BLANK (SOLID) COVERS. TO INSTALL THE EXTERIOR LIGHT FIXTURES, REMOVE THE BLANK COVERS FROM THE ELECTRICAL BOXES AND FEED THE THREE WIRES (IDENTIFIED IN THE DETAIL ABOVE) THROUGH THE FIXTURE FLASHING RING BEFORE THE CONNECTIONS OF THE CONDUCTORS ARE MADE. THE FIXTURE FLASHING RINGS MUST EXTEND FROM THE OPENING OF THE ELECTRICAL BOX TO THE OUTERMOST EDGES OF THE EXTERIOR LIGHT FIXTURE (EXCESS AMOUNT OF THE FLASHING RING MAY BE TRIMMED OFF AFTER THE FIXTURE IS SECURED TO THE ELECTRICAL BOX). TO INSURE AGAINST THE POSSIBILITY OF AN ELECTRICAL SHOCK, ALL ELECTRICAL CONNECTIONS SHOULD BE DONE WITH THE ELECTRICAL SERVICE SHUT OFF TO THE HOME. THE WIRE NUTS REQUIRED FOR SECURING THE WIRES WILL BE FOUND INSIDE THE ELECTRICAL BOX FOR THE FIXTURE (THESE WIRE NUTS ARE INSTALLED AT THE FACTORY TO CAP THE CONDUCTORS IN THE ELECTRICAL BOX). THE FIXTURE FLASHING RING IS LOCATED IN THE SHIPPING KIT INSIDE THE HOME. JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: S.A. DATE: 6-6-94 REV. LETTER: i❑❑❑❑ DRAWING TITLE: ❑❑■❑ORIGINAL, PROPRIETARY, AND CONFIDENTIAL ❑„❑ P.O. BOX 368 MATERIALS OF MANUFACTURING INC. SUCH MATERIALSRIALS ARE ARE PROVIDED TO THE LIGHT FIXTURE INSTALLATION DRAWING NUMBER: SU-09-0030 ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. MOBILE HOME SET-UP PLUMBING CONNECTIONS CHECK WATER AND DRAIN LINES FOR ANY CONNECTIONS THAT MAY HAVE COME LOOSE DURING SHIPMENT. SHOULD YOUR HOME NOT BE EQUIPPED WITH A MASTER SHUT-OFF VALVE, ONE MUST BE INSTALLED BETWEEN THE HOME AND THE WATER SUPPLY. THE WATER SUPPLY SYSTEM IS DESIGNED FOR A MAXIMUM INLET WATER PRESSURE OF 80 PSI. IF THE LOCAL WATER SUPPLY PRESSURE TO WHICH THE HOME IS BEING CONNECTED EXCEEDS 80 PSI, A PRESSURE REDUCING VALVE SHOULD BE INSTALLED TO LIMIT THE SUPPLY PRESSURE. WHEN HOMES ARE SET IN AREAS SUBJECT TO FREEZING THE EXPOSED WATER SUPPLY LINES MUST BE PROTECTED. AN ELECTRICAL RECEPTACLE IS LOCATED ON THE UNDERSIDE OF THE HOME NEAR THE WATER INLET, AND NEAR ANY CROSSOVER LOCATION WHERE THE WATER LINES ARE EXPOSED. THESE ELECTRICAL RECEPTACLES ARE FOR THE CONNECTION OF AN ELECTRICAL HEAT TAPE. HEAT TAPE USED MUST BE LISTED FOR USE WITH MOBILE HOMES. FOR MULTIPLE SECTION HOMES WITH PLUMBING IN MORE THAN ONE SECTION, LOCATE AND CONNECT THE WATER CROSSOVERS LOCATED UNDER THE FLOOR ALONG THE MARRIAGE LINE BETWEEN THE SECTIONS. TURN THE WATER SUPPLY ON AND CHECK FOR LEAKAGE. CAUTION: DO NOT TURN THE POWER ON TO THE WATER HEATER UNTIL THE TANK IS FULL OF WATER. CONNECT DRAIN DROP OUTS TO COMPLETE ALL FIXTURE DRAINS AND MAIN DRAIN. BE SURE ALL CONNECTIONS ARE MADE TO COMPLY WITH LOCAL PLUMBING CODES. GAS PIPING HOMES WITH GAS PIPING HAVE BEEN FACTORY TESTED FOR LEAKS, HOWEVER, BEFORE CONNECTING THE GAS SUPPLY TO THE SYSTEM ANOTHER PRESSURE TESTIS RECOMMENDED TO INSURE THAT THERE ARE NO LEAKS AFTER THE HOME HAS BEEN TRANSPORTED AND SET-UP. 1. CLOSE OFF ALL THE GAS APPLIANCE SHUT OFF VALVES. 2. ATTACH THE GAS TEST FITTING GAUGE. 3. PRESUREIZE THE SYSTEM UNTIL 3 PSI OF AIR PRESSURE IS REACHED. 4. PRESSURE MUST BE MAINTAINED FOR 10 MINUTES WITHOUT ANY INDICATED PRESSURE LOSS. CAUTION: DAMAGE MAY RESULT IF THE SYSTEM IS OVER PRESSUREIZED, THE GAS PIPING SUPPLY SYSTEM HAS BEEN DESIGNED FOR A MAXIMUM PRESSURE OF 14" WATER COLUMN (1/2 PSI) AND NOT LESS THAN 7" WATER COLUMN (1/4 PSI). THE GAS PIPING SYSTEM IS DESIGNED TO USE EITHER LIQUIFIED PETROLEUM GAS OR NATURAL GAS. BEFORE TURNING THE GAS ON: 1. BE SURE THE APPLIANCES IN YOUR HOME ARE DESIGNED FOR THE TYPE OF GAS BEING CONNECTED. 2. WHERE APPLICABLE ON MULTIPLE WIDE HOMES, LOCATE "QUICK -DISCONNECT" AND CONNECT. THE "QUICK -DISCONNECT" IS LOCATED UNDER THE FLOOR AT THE MARRIAGE LINE. 3. MAKE SURE ALL CONNECTIONS ARE TIGHT, AND ALL APPLIANCES ARE TURNED OFF. 4. AFTER THE GAS HAS BEEN CONNECTED AND TURNED ON, MAKE SURE ALL THE PILOT LIGHTS ARE LIT. ❑❑❑❑ JAC 0 B S E N HOMES THESE SPECIFICATIONS NOTICE: AND DRAN7NG5 ARE DRAWN BY: S.A. DATE: 3-22-95 REV. LETTER: ❑❑■❑ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: ❑„❑ P.O. BOX 368 MATERIALS OF MANUFACTURING INC. SUCH MATERIALSRIALS ARE ARE PROVIDED TO THE PLUMBING CONNECTION +GAS PIPING ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: PHONE (727) 726-113B KEPT CONFIDENTIAL AND SECRET FROM OTHERS. SU-11 -0001 MOBILE HOME SET-UP SET-UP KIT PLUMBING FITTINGS FITTING NAME: COUPLER SYMBOL ORIENTATION / USE COUPLING I PIPE SPLICING DIRECTION OF FLOW FITTING NAME: SANITARY TEE SYMBOL ORIENTATION / USE SAN. TEE HORIZONTAL TO VERTICAL ONLY FITTING NAME: LONG TURN 90' ELL SYMBOL ORIENTATION / USE 90' ELL MAY BE USED IN ANY ORIENTATION CHECK THE INSTALLATION INSTRUCTIONS FOR MATERIALS REQUIRED AND PLACEMENT OF FITTINGS, NOTE AS SHOWN IN THE DETAILS THE DIRECTION OF FLOW FOR FITTINGS. ALL PIPING REQUIRED TO FIT BETWEEN FITTINGS IS INCLUDED IN THE SET-UP MATERIALS. THE LENGTHS OF PIPE SHOULD BE CHECKED BEFORE CUTTING TO ENSURE THAT PROPER DROP-OFF IS REMAINING FOR COMPLETION OF PIPE RUNS. DRY FITTING ALL PARTS TOGETHER IS RECOMENDED BEFORE ANY FITTING AND PIPE JOINT IS GLUED. (fi _ff DIRECTION OF FLOW FITTING NAME: REDUCER BUSHING SYMBOL ORIENTATION / USE BUSHING REDUCE FITTING PIPE SIZE DIRECTION OF FLOW FITTING NAME: LONG TURN TEE WYE SYMBOL ORIENTATION / USE LTTY MAY BE USED IN ANY ORIENTATION SET-UP INSTRUCTION SYMBOLS O. = 1 1/2" DROP O. = 1 1/2" DRY VENT O = 2" DROP O = 2" VIET VENT 0 = 3" DROP O = 3" MAIN DRAIN - - - - = 1 1/2" DRAIN LINE = 2" DRAIN LINE = 3" DRAIN LINE NOTE: USE A GOOD QUALITY CLEANER AND CEMENT LISTED FOR USE WITH PVC PIPING CONNECTIONS. BE SURE TO FOLLOW THE MANUFACTURERS INSRUCTIONS ON THE CONTAINERS. � ❑❑❑ �;;� [Ell Up: JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF MATERIALS ARE MANUFACTURING INC. SUCH MATERIALS ARE PRONGED TO THE RECIPIENT FOR SPECIRC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWN BY: S.A. DATE: 6-6-94 DRAWING TITLE: . SET-UP KIT. PL. FITTINGS DRAWING NUMBER: - SU 1 0010 MOBILE HOME SET-UP 2" WET VENT WITH NOT MORE THAN UNVENTED r2" (1) FIXTURE DRAIN W.C. DROP3 2" 3" ALT. 3" 1 1/2" DRY VENT (SEE ALT. FOR OPT. WET VENT W.C. DROOPP UNVENT/ / CONNECTION) / / 1 1/2" / 3" / O / / O3^ 3" D 3" VENTED W.C. DROP / TYPICAL / / 2" DROP / INDICATES BOTTOM S. OF HOME / 2" 3" 1 O MINIMUM SLOPE 3•• /j 1/8" PER FT. / 1 WITH CLEAN -OUT / 1/4" PER FT. WITHOUT CLEAN -OUT 3" TO ON SITE DRAIN CONNECTION 3" 2" OA TYPICAL 3" Q 1 1/2" DROP O / / / / / 1 1/2" 1 1/2' INSTALL FULL SIZE CLEAN -OUT IF SLOPE IS BETWEEN 1/8" & 1/4" PER FOOT USE OD IF CLEAN - OUT IS NOT NEEDED FITTING SCHEDULE O VERT. TO HORIZ. (LONG TURN TY OR COMB. Y & 1/8 BEND) OB HORIZ. TO HORIZ. (LONG TURN TY OR COMB. Y & 1/8 BEND) © HORIZ. TO VERT. (1/4 BEND -LONG ELL) OD VERT. TO HORIZ. (LONG SWEEP 1/4 BEND) OE HORIZ. TO VERT. (SHORT TURN TY - SAN. TEE) TYPICAL ON SITE DRAIN CONNECTIONS 3/4" DROP FROM WATER HEATER / SECTION I I,- / �3/4" THREADED INLET / 3/4" DROP -3/4" ELL / / / X/ / 3/4" TEE AND FRESH WATER INLET FOR 3/4" THREADED 3/4" ELL N07 INLET -FIELD SINGLE ODES AND MULTI- THE TWO EXAMPLES SHOWN ARE INSTALLED WIDES WITH PLUMBING IN TYPICAL FOR MOST MODELS. ONE SECTION ONLY SOME MODELS DEPENDING 3/4" CROSS-OVERS ON THE PLUMBING LAY -OUT FRESH WATER INLET FOR (FIELD INSTALLED) MAY HAVE A COMBINATION MULTI-WIDES WITH OF BOTH OF THE EXAMPLES SHOWN. PLUMBING IN MORE THAN ONE SECTION TYPICAL FRESH WATER ENTRANCES NOTICE: DRAWN BY: DATE: REV. LETTER: ❑❑❑❑ JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWINGS ARE S.A. 6-6-94 ❑❑■❑ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: ❑„❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING DRAIN SET-UP INC. SUCH MATERIALS ARE PROVIDED TO THE SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: ❑❑❑❑ PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS. SU-1I-0005 FLOOR JOIST MAY BE NOTCHED AT PLUMBING CROSS -OVER (SEE ELECTRICAL SET-UP FOR SPECIFICATIONS). WATER LINE CROSS -OVER (SEE DETAIL BELOW) TvninAI IAADOIA!`C 11A17' rnr TYPICAL FLOOR ASSEMBLY ATER CROSS -OVER MINIMUM AND BOTTOM BOARD OVER WATER CROSS -OVER LINES NOTE: NO HEAT TAPE RECEPT. REQUIRED AT INSULATED WATER CROSS -OVER. CONNECT WATER LINES TOGETHER AT ALL CROSSOVER LOCATIONS. INSTALL R-7 MINIMUM INSULATION BLANKET OVER THE WATER CROSS —OVER LINES AND SECURE INTO PLACE WITH DUCT TAPE. PLACE A PIECE OF BOTTOM BOARD MATERIAL LARGE ENOUGH TO COVER WATER CROSS —OVER LINES AND INSULATION AND SECURE TO FLOOR FRAMING MEMBERS WITH 1" X 1" X 16 GA. STAPLES MINIMUM AT EACH FRAMING MEMBER, AND TAPE OVER SEAMS WITH CLOTH DUCT TAPE OR EQUAL. ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: C.L.Y. DATE: 10-23-95 REV. LETTER: ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING DRAWING TITLE: WATER CROSS -OVER ❑"❑ P.O. BOX 368 INC. SUCH MATERIALS ARE PRONDED TO THE ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-11 -0020 MOBILE HOME SET-UP 6. A.C. CONNECTIONS JACOBSEN MOBILE HOMES ARE MADE AIR CONDITIONER READY, WHICH MEANS THE REGISTERS, SUPPLY DUCTS, AND RETURN AIR FACILITIES ARE ALREADY INSTALLED IN YOUR HOME. IN A MULTI — SECTION HOME THERE IS ONE SUPPLY DROP PER SECTION, AND ONE RETURN AIR DROP FOR THE ENTIRE HOME. CONNECT THE RETURN AIR DROP TO THE INTAKE SIDE OF THE AIR CONDITIONING UNIT, AND CONNECT THE SUPPLY DROPS REDUCER "Y" FITTING(S) (i.e., (1) 12" TO (2) 10") TO THE BLOWER SIDE. FOR SINGLE UNIT HOMES, THERE IS ONE SUPPLY DROP, CONNECT THAT ONE DROP DIRECTLY TO THE BLOWER SIDE OF THE AIR CONDITIONING UNIT. ALL CONNECTIONS BETWEEN THE AIR CONDITIONER AND DROPS CAN BE MADE WITH INSULATED FLEXIBLE DUCT. CHECK THESE ITEMS AFTER THE AIR CONDITIONER IS INSTALLED. 1. ALL DUCT WORK BELOW THE HOME IS INSULATED. 2. ALL SEAMS ARE SEALED. 3. ALL CONNECTIONS ARE INSULATED AND TIGHT FITTING. UNIT IS SHO AND ONE RE WILL VARY E HAVE MORE UR rrvvCR JUrrLT UR RETURN DUCTS. ^11 (AIR ,HANDLER, CONDENSER, AND COMPRESSOR) TYPICAL DOUBLE WIDE A.C. CONNECTIONS NOTE: ON SOME MODELS THE SUPPLY AND/OR RETURN AIR DROPS PROVIDED ON THE HOME MAY BE LOCATED DIRECTLY OVER THE RUNNING GEAR (TIRE AND/OR AXLE). ON HOMES WITH THE DROP LOCATIONS LOCATED ABOVE THE RUNNING GEAR IT IS NECESSARY TO REMOVE THE RUNNING GEAR BEFORE HOOKING UP THE SUPPLY AND/OR RETURN AIR DUCT FROM THE AIR CONDITIONER UNIT TO THE HOME. ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: S.A. I DATE: 6-6-94 REV. LETTER: -0 ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: ❑„❑ P.O. BOX 36B MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE DOUBLE WIDE A.C. CONNECTIONS ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS. SU-1 3-0001 MOBILE HOME SET-UP USE THE FOLLOWING INSTRUCTIONS WHERE APPLIED TO DUCTWORK PROVIDED BY JACOBSEN HOMES FOR AIR CONDITIONER INSTALLATION. CHECK THE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR ALL ADDITIONAL DUCTS USED DURING AIR CONDITIONER HOOK—UP FOR RECOMMENDED INSTALLATION PROCEDURES FOR THE TYPE DUCT BEING USED. METHOD PRESSURE DETAILS CONNECTIONS SPLICES LIMITATIONS TAPE ONLY A) FOLD BACK JACKET AND INSULATION A) FOLD BACK JACKET AND INSULATION FROM END OF DUCT EXPOSING CORE. FROM END OF DUCTS EXPOSING CORE. (FOR LOW B) SLIP CORE OVER FITTING AT LEAST B) INSERT ONE CORE INTO THE OTHER PRESSURE 1 1/2 INCHES. ABOUT THREE INCHES. NOT TO EXCEED C) APPLY DUCT TAPE* AROUND CORE AND C) APPLY DUCT TAPE* AROUND OUTSIDE CONNECTING 2 IN. W.G.) FITTING WITH AN EQUAL TAPE WIDTH ON OF CORE EDGE WITH EQUAL WIDTH ON EACH. EACH CORE. PULL BACK INSULATION AND JACKET D) BUTT INSULATION AND PULL JACKET MC,D) OVER FITTING. FROM ONE DUCT OVER OTHER DUCT. E) APPLY DUCT TAPE* AROUND JACKET E) APPLY DUCT TAPE* AROUND OUTSIDE 0 o AND FITTING WITH AN EQUAL TAPE OF JACKET EDGE WITH EQUAL TAPE WIDTH ON EACH. WIDTH ON EACH JACKET. SPLICING CLAMP ONLY A) SLIP DUCT OVER FITTING AT LEAST A) FOLLOW AS DIRECTED UNDER THREE INCHES. 'CONNECTIONS' BUTTING TWO DUCTS METAL CLAMP B) PLACE CLAMP** AROUND DUCT AT TOGETHER ON A STANDARD SHEET (FOR LOW TO BondEi FITTING AND TIGHTEN WITH APPROPRIATE METAL COUPLING AT LEAST SIX INCHES MEDIUM PRESSURE TOOL UNTIL ALL MATERIAL UNDER CLAMP IN LENGTH. NOT TO EXCEED HAS BEEN COMPRESSED AND CLAMPING 4 IN. W.G.) PRESSURE IS ASSURED. SEE PRESURE C) CHECK CONNECTION BY PULLING ON LIMITATIONS FOR DUCT WITH A FORCE OF AT LEAST 25 PLASTIC CLAMPS** MIN. LBS. TO INSURE DUCT HAS BEEN ADEQUATELY CLAMPED. CONNECTING OR SPLICING -APE & CLAMP (FOR LOW, MEDIUM m 04, )R HIGH PRESSURE NOT TO EXCEED It 10 IN. W.G.) SEE PRESURE CONNECTING LIMITATIONS FOR PLASTIC CLAMPS** SPLICING A) PULL BACK JACKET AND INSULATION FROM END OF DUCT EXPOSING CORE. B) SLIP CORE OVER FITTING AT LEAST 1 1/2 INCHES. C) APPLY DUCT TAPE* AROUND CORE AND FITTING WITH EQUAL TAPE WIDTH ON EACH. D) PLACE CLAMP** AROUND TAPE AND CORE AND TIGHTEN WITH APPROPRIATE TOOL. E) PULL BACK INSULATION AND JACKET AND APPLY DUCT TAPE* AROUND JACKET AND FITTING. WITH TABBED DUCTBOARD FITTINGS, OUTER JACKET MAY BE 'DIAPERED' INSTEAD OF TAPED (SEE STEP F). F) PULL JACKET OVER RING, THROUGH HOLE, AND FOLD UP WITH TABS. A) BUTT TWO CORES TOGETHER ON A SIX INCH METAL COUPLING AND FOLLOW DIRECTIONS UNDER 'CONNECTIONS'. * DUCT TAPE: USE A MINIMUM OF ONE WRAP OF 2 INCH OR TWO WRAPS OF 1 1/2 INCH WIDTH OF TYPE SHUFORD #PC622, TUCK #92T, ARNO #C520, POLYKEN #222, OR NASHUA #357. ** PLASTIC CLAMPS: PLASTIC CLAMPS ARE NOT RECOMMENDED FOR PRESSURES EXCEEDING 4 IN. W.G. (DIAMETERS 3" — 10") AND 2 IN. W.G. (DIAMETERS 12" AND OVER) TO ACHIEVE PROPER TENSIONING OF PLASTIC CLAMP, SET CORRESPONDING TOOL AT MAXIMUM TENSION SETTING. APPROVED TYPES: PANDUIT TYPE PLT—H (TOOL G); CATAMOUNT L-175 (TOOL L-300); OR TYTON T-150 (TOOL T-150). 11 NOTICE: DRAWN BY: DATE: REV. LETTER: ❑❑❑❑ JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWINGS ARE S.A. 6-6-94 ❑❑■❑ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: EE„❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING INC. SUCH MATERIALS ARE PROVIDED TO THE MOBILE HOME SET—UP DUCTWORK ❑❑❑ SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS. SU-13-001 O ELECTRIC CLOTHES DRYER VENTING IMPORTANT - BEFORE DRYER IS USED IT MUST BE VENTED TO THE OUTSIDE OF THE HOME. THE VENT MUST NOT TERMINATE INSIDE THE SKIRTED AREA UNDER THE HOME, THIS WOULD RESULT IN EXCESSIVE HUMIDITY IN THE HOME. HOMES SET UP TO RECEIVE A DRYER ARE EQUIPPED WITH A VENT HOLE PRE -DRILLED THROUGH THE FLOOR AT THE DRYER LOCATION. TO COMPLETE THE DRYER EXHAUST SYSTEM, FOLLOW THESE PROCEDURES: 1. REMOVE THE DRYER VENT ACCESS HOLE COVER. 2. CUT DRYER VENT DUCT TO THE PROPER LENGTH, AND CHECK FOR OBSTRUCTIONS. THEN CONNECT TO DRYER IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. 3. SECURE THE VENT CAP TO THE OUTSIDE OF THE SKIRTING AT THE APPROPRIATE LOCATION. 4. SECURE THE END OF THE FLEXIBLE DRYER DUCT TO THE VENT CAP AT THE EXTERIOR OF THE HOME WITH CLAMPS. NOTE: DO NOT USE ANY SCREWS OR OTHER DEVICES THAT EXTEND INTO THE DUCT. 5. STRAP THE DRYER DUCT TO THE UNDERSIDE OF THE HOME TO PREVENT THE DUCT FROM COMING IN CONTACT WITH THE GROUND. 6. SEAL THE OPENINGS AROUND THE DUCT WHERE IT PASSES THROUGH THE FLOOR WITH CAULK OR DUCT TAPE, AND THE BOTTOM BOARD WITH DUCT TAPE. JACOBSEN HOMES WILL NOT BE RESPONSIBLE FOR DAMAGE TO THE HOME RESULTING FROM FAILURE TO INSTALL THE DRYER EXHAUST SYSTEM IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND THE INSTRUCTIONS LISTED ABOVE. NOTE: GAS DRYER INSTALLATION MUST BE DONE BY QUALIFIED PERSONNEL. THE CUTTING OF STRUCTURAL ELEMENTS OF THE HOME, SUCH AS RAFTERS OR FLOOR JOISTS TO EXPEDITE INSTALLATION IS PROHIBITED. ANY WEAKENING OF THE STRUCTURE RESULTING FROM SUCH CUTTING IS NOT THE RESPONSIBILITY OF JACOBSEN HOMES, AND MAY RESULT IN NEGATING YOUR WARRANTY. VSTALLED DUCT ;T BE METAL :X OR RIGID CAP CAP NOTES: ❑❑❑❑ JACOBSEN HOMES NOTICE: THESE SPECIFICATIONS AND DRAWINGS ARE DRAWN BY: R.R. DATE: 01-21-00 REV. LETTER: ❑❑■❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF MANUFACTURING DRAWING TITLE: ❑„❑ P.O. BOX 368 INC. SUCH MATERIALSRIALS ARE ARE PRONDEO TO THE ELECT. CLOTHES DRYER VENTING ❑❑❑❑ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWING NUMBER: SU-15-0001 DOWN DRAFT RANGE VENTING -S. IMPORTANT - BEFORE RANGE IS USED IT MUST BE VENTED TO THE OUTSIDE OF THE HOME. THE VENT MUST NOT TERMINATE INSIDE THE SKIRTED AREA UNDER THE HOME, THIS WOULD RESULT IN EXCESSIVE HUMIDITY IN THE HOME. HOMES WITH A DOWN DRAFT RANGE ARE EQUIPED WITH EXHAUST DUCT INSTALLED FROM THE RANGE THROUGH THE FLOOR, THE REMAINING DUCT IS SENT WITH THE HOME AND MUST BE INSTALLED ON SITE. 1. LOCATE DUCT DROP FROM RANGE. (MAY BE EXTENDING THROUGH BOTTOM BOARD, OR SEALED INSIDE) 2. CHECK DUCT PROVIDED FOR PROPER LENGTH, AND OBSTRUCTIONS. THEN CONNECT TO DUCT DROP FROM RANGE IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. 3. SECURE THE VENT CAP TO THE OUTSIDE OF THE SKIRTING AT THE APPROPRIATE LOCATION. 4. SECURE THE END OF THE DOWN DRAFT RANGE DUCT TO THE VENT CAP AT THE EXTERIOR OF THE HOME WITH CLAMPS OR SCREWS. NOTE: DO NOT USE ANY FASTENERS THAT CRUSH OR BLOCK THE DUCT. 5. STRAP THE DUCT TO THE UNDERSIDE OF THE HOME TO PREVENT THE DUCT FROM BENDING OR COMING IN CONTACT WITH THE GROUND. 6. SEAL THE OPENINGS AROUND THE DUCT WHERE IT PASSES THROUGH THE FLOOR WITH CAULK OR DUCT TAPE, AND THE BOTTOM BOARD WITH DUCT TAPE. JACOBSEN HOMES WILL NOT BE RESPONSIBLE FOR DAMAGE TO THE HOME RESULTING FROM FAILURE TO INSTALL THE RANGE EXHAUST SYSTEM IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, AND THE INSTRUCTIONS LISTED ABOVE. RANGE NOTE: DROP LOCATED DIRECTLY BELOW RANGE BLOWER MOTOR SITE INSTALLED DUCT i VENT CAP NOTICE: DRAWN BY: DATE: REV. LETTER: 1111 ❑❑❑ JACOBSEN HOMES THESE SPECIFICATIONS AND ORAVANGS ARE S.A. 6-6-94 ILI;;❑❑ ORIGINAL, PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING NC. SUCH MATERIALS ARE FRONDED TO THE DOWN DRAFT RANGE VENTING li ❑❑❑ SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE DRAWING NUMBER: PHONE (727) 726-1138 KEPT CONFIDENTIAL AND SECRET FROM OTHERS. SU-1 5-0002 BOTTOM BOARD P-TRAP ACCESS PANELS - TAPE APPLIED OVER ALL SEAMS AT PATCH APPROX. 1" PATCH TO BE SAME MATERIAL AS BOTTOM BOARD BEING' REPAIRED. HOLE MAY BE (3) SIDED CUT IN BOTTOM BOARD AND TAPE USED TO SEAL EXISTING MATERIAL BACI,. OVER OPENING NOTES: 1. P-TRAP .ACCESS PANELS WILL BE BELOW P-TRAP .AREA IN FLOOR. P-TRAP ACCESS PANELS MAY BE 3 OR 4 SIDED, AND WILL HAVE 3 OR 4 ROWS OF TAPE AT THE PERIMETER OF THE PANEL. 3 NORMAL BOTTOM BOARD REPAIRS WILL HAVE ONLY TAPE OVER THE CUT OR DAMAGED AREA. 4 MINOR HOLES AROUND PIPES ETC. MAY BE SEALED WITH TAPE 5 THESE ARE SOME ACCEPTABLE TAPES TO USE FOR REPAIR; SHURTAPE PC658, FIRST LINE 620 ❑❑❑❑ ❑❑■❑ ❑„❑ ❑❑❑❑ J A C O B S E N HOMES P.O. BOX 368 :SAFETY HARBOR., FLORIDA 34695 PHONE (727) 726-1138 NOTICE: THESE SPECIFICATIONS AND DRAVANGS ARE ORIGINAL, PROPRIETARY, AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTURING NC. SUCH MATERIALS ARE PROVIDED TO THE RECIPIENT FOR SPECIFIC PURPOSES AND MUST BE KEPT CONFIDENTIAL AND SECRET FROM OTHERS. DRAWN BY: R.R. I DATE: 10- 31- 01 REV. LETTER: DRAWING TITLE: BOTTOM BOARD P-TRAP ACCESS DRAWING NUMBER: SU-15-0010 Ole