HomeMy WebLinkAboutBLOWER DOOR TEST FORMPlanning &Development Services
r_ t Building &Code Regulation Division RFC
2300 Virginia Ave, Rm 201 FI�FD.
• Fort Pierce; FL 34982. per FFB: 2 6 ?01e .
Phone: 772 462-2165 Fax: 772=462-6443 S4. �ttin
s�Uae �� q m� �
BLOWER DOOR,TEST FORM. w -B
House Infiltration -Test Certification.. � Ln1 9� ���
Prescriptive and Performance Method.
a.57l v
Date: Permit M.
Contractor:.....
Job Address:.. l . �661Swe--
:Construction: New Construction '"Comp.lete ( ).Existing After Addition--.
(q� �:,
House InfiltrationTest Results SLC.Climate Zone 2.
CFM (50)
5 : '.. Test Date:
Volume
ACH (50) =.CFM �(50).x 60-/-Volume Quired less than 3 ACH ' � M chanical Ventilation re
Passing results Must be &ACH (50) or less ) Pass ( )Fail
FBC, Energy.
The building:or dwelling unit; shall be tested andberified as having an air leakage. rate of not'exceeding pair changes per
hour in: Climate -Zone 1,:-2 and 3 air changes per hour.in Climate Zones 3.through 8.- Testing'shall be conducted With a,
blower.door;at a pressure of:0,2 inches.w: g, (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (1), Florida Statutes or individuals licensed as set forth in Section 489.10.5 (3)(f); (g) or (i),or an
approved third party,.' A written report of the results of test shall be signed by. the_ party:conducting the, test and
provided to the code.officibl. Testing shall be performed at anytime after -creation of. all. pehetrations of. thebuilding
thermal envelope.: .
FBC, Residential
Where:the.air.infiitration rate .of. a dwel.iing.ur' it.is less ihan.3 air.changes per hour when tested with a blower door at a . .
pressure.of 0.2 inch w. _c.. (50:Pa) in accordance'with Section R402.4.:1.2 of the Florida Building Code,:Energ}r Conservation
the dwelling.unit shall.be provided with:whole=house mechanical Ventilation in accordance with Section M1507.3:..
Testing Company / '7 %'� (. ( ` / !
Company Name: &FA Address: (.CD (%PW G. W► 69C .. (� V PISLr
l hereby certify that the above House Infiltration.results demonstrate compliarice with FBC Energy Conservation
requirements accord ce w th Section 11402.4:1.2 Climate Zone 2.
ISO7_ O'GSI�
\1
t : Planning& -Development Services C
Building & Code Regulation DivisionF p
2300 Virginia Ave, Rm 201
Cop
• Fort Pierce,.FL.,34982_ • er ?0
772Ak-2165 Fax 772- U-M43 SF Ong �e �B
U�� par
FBC ENERGY CONSERVATION CODE e �0�nty enF
Duct Sealing Certification
Prescriptive and Performance Method
'Date: Permit #: ` 2i O.� • Lot #: .
- Address: o
Contractor: \" C..hb.ra�St. Df..
Cons(ruction:. ' .Post Construction Test o Rough -in Test
Test Conditions:
Date: Floor Area (ft2):..
Time: 1 0.0 Primary Location of Supply Ductwork
Indoor Temperature (F):. �Primery Location 'of Return Ductwork . .
Outdoor Temperature (F):.. 7(
Total Leakade-Test (Outside) = .
Duct Leakage: ❑ Default , ❑Prop: Leak Free " Proposed On D .; [)
3.
Test Pressure: (Pa) :. �.
Baseline Duct Pressure option al : Pa mil.
c2
Duct Press. (Pa) . Flow Ring - Fan Press Flow (cfm): Results: 4 Pass ❑. Fail
Install Pa
Total Leakage (cfm): .
Total Leakage per100 sgft:
GFGr�
CFM25 z 100 divided by the CFA ' -Duct Leakage CFM1100 sqft. -