HomeMy WebLinkAboutLETTER ROOFING SPECIFICATIONSrchitectonic
ly 12, 2018
int Lucie County Building Department
tn: Roof Permit Plan Review
00 Virginia Avenue
Pierce, FL 34982
lnc..,u'
SMNNED
RECEIVE®
ST. Lucie County, Permitting
Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure
located at 480 Sandia Avenue, Saint Lucie County, Florida
anufacturer: Polyglass USA
ofiles: Modified Bitumen Roof System; FL #1654-R22
,de: FBC 2017; Section 1507
ind Speed: 160 MPH; Ultimate Design Wind; Speeds
posure: B
can Roof Height: 30' Maximum
tch: 1 /12 Minimum
squired Design Pressure: Zone1: -76 Zone 2: -41 Zone3: -57
aximum Uplift Pressure: -90 psf
ise: SBS-SA (self- adhering)
y Sheet: (Optional) One or more Elastoflex SA V Base (self -adhering)
1p: SBS-SA, $BS-TA, APP-SA, APP-TA (self -adhering)
)of Decking: Existing $/8" plywood sheathing to be nailed w/8d x Z,ring shank
@ 6" O.Q. thru out zone 1, 4" Q.C. perimeter, and 6" O.C. field zone 2,
and 4" Q.C. thru out zone 3.
The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code,
and the Manufacturer's recommendations.
ctfully sub ixtcl, 9
ARBR298 :C
t I,Seal •, �
t'' is lrac,••.••G�`
� QED P�
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL. Reg #AA26003348 1 of 1