HomeMy WebLinkAboutLETTER ROOFING SPECIFICATIONSrchitectonic ly 12, 2018 int Lucie County Building Department tn: Roof Permit Plan Review 00 Virginia Avenue Pierce, FL 34982 lnc..,u' SMNNED RECEIVE® ST. Lucie County, Permitting Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at 480 Sandia Avenue, Saint Lucie County, Florida anufacturer: Polyglass USA ofiles: Modified Bitumen Roof System; FL #1654-R22 ,de: FBC 2017; Section 1507 ind Speed: 160 MPH; Ultimate Design Wind; Speeds posure: B can Roof Height: 30' Maximum tch: 1 /12 Minimum squired Design Pressure: Zone1: -76 Zone 2: -41 Zone3: -57 aximum Uplift Pressure: -90 psf ise: SBS-SA (self- adhering) y Sheet: (Optional) One or more Elastoflex SA V Base (self -adhering) 1p: SBS-SA, $BS-TA, APP-SA, APP-TA (self -adhering) )of Decking: Existing $/8" plywood sheathing to be nailed w/8d x Z,ring shank @ 6" O.Q. thru out zone 1, 4" Q.C. perimeter, and 6" O.C. field zone 2, and 4" Q.C. thru out zone 3. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. ctfully sub ixtcl, 9 ARBR298 :C t I,Seal •, � t'' is lrac,••.••G�` � QED P� 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL. Reg #AA26003348 1 of 1