HomeMy WebLinkAboutBOUNDARY SURVEY1
'
> s=:
RA, B=25.00'
FiRc
j PSM404
S
VD,rDel
t
=186-19'0
Le
y gth=38.27'
Na
qy\-
�i
FPKD
30.00' PSM4049
ry .
I
,rn ._�rn
•m
I
rt I
,
Zi
.T;
.+
O
3
------t 25.0'-
Prepared For:
cie
1v
22.3'
Mr. and Mrs. Kiss
10' Utility 1 01 ent
9
30.6
Plat 13, Unit 43
m o One Story Building
- 13300 Maplewood Drive
64.4'
Raalu' 2o2g°3:s
Delta=t;g9.28
Leng
N83040'56 "E 121.75"
Unit 42
_----22.4'_-
10
':
Ir
1'2 40'.�:
CD
11 90'
JIL --20.04'
O
cn V .
SA
Lno'�o
Cb
to
t•..
a
Cb a c
Gt
CX
- - 20.00'
V
.12.40'
=9g',
I
No iD
r
+
� 1
LEGAL DESCRIPTION
RECEIVED
Uni 43, Buttonbush Village, HARBOUR RiDGE Plat NO.13, according
o the Plat thereof, as recorded in Plat Book 28, Pages 3,
SEP 13
3A-3H, Public Records of St. Lucie County, Florida.
SURVEYOR'S REPORT
ST. County, Permitting
1 This Survey shall not be valid unless sealed with an embossed
Surveyor's Seal
2 No underground improvements .have been located as part of
this Survey.
LEGEND
3 The last field date of this Survey was: 8.10.2018
CIE - Covered Entry
4 This Survey was prepared using the Plat of Record only. No
CACat h Concrete Podwith Air Conditioning
CB
other documents were provided and no search of the public
CBS = Concrete Block Structure
records was performed by this office.
CMP - Corrugated Metal Pipe
CPE - Concrete Pad with Pool Equipment
5 The Survey shown hereon meets _ the requirement for field
CTV - Cable Tv Box
accuracy in a suburban area as set forth by the Minimum
cv -water cote Valve
FIYD -Fire Hydrant
Technical Standards (5J- 1 7.050-052FAC).
OIL - Overhead Utility Line
6 By acceptance of this survey oil parties agree that the signing
PPA - Power Pole with Guy Anchor
SSMH -Sanitary Sewer Manhole
surveyors liability is limited to the amount aid for said Survey.
y y P }'•
TCB - Telephone Communications Box
7 Unless other wise noted all bearing and distances are in
ua - uerty,eox
WM - Water Meter
accordance with the record plat and have been verified by field
FCM - Found 4 W Concrete Monument
measurements. See map for bearing base.
nP - Found I' Iron Pipe
8 Parcel/Lot line locations have been based on found survey
F7PnR - Found Iron Pipe with cap
FIR -Found 5 Iron Rod
control along the center and or Right of Way line of Maplewood
g / g y p
F7RC - Found 15 iron Rod with Cap
Or and Buttonbush Circle
SIRC - Set #5 Iron Rod with cap 18#7357' g There is apparent use of the property by the Golf Cart Path as
FIPC - Found 112' Iron Pipe with Cop
FM - Found Mog Nail
Mag
shown hereon
FMD - Found Nail with Disk
10 The Legal Description shown hereon was provided by the client
FN - Found Nail
FNTT - Found Nail with Tin Tab
and/or his/her representatives.
FPK - Found PK Nail
FPKD - Found PK Nail with Disk
11 No ownershipof fence lines has been determined as art of
P
FRRS - Found Rail Road Spike
this Survey.
/CO - In Pavement Cut Out
12 Off set calls to found survey control are relative to the
nearest property corner, intersection of lines, point of curvatures
(PC), point of reverse curvatures (PRC) or other identifiable point.
13 Compliance with local zoning requirements and or with
MIN. SETBACK REQ.
requirements set forth by other State, Public, and/or Private
entities has not been verified as part of this Survey.
FRONT
SIDES
CNR SIDES
REAR
FEMA Flood Zone data shown here on is based on
ZNG.
j' the visual inspection of the digital Flood Hazardous
TECH. Mli ; Maps provided by the Federal Emergency
8'
KARNER SURVEYING, INC.
Residential & Commercial Surveying Services
2740 SW Martin Downs Blvd.#333, Palm City, F1.34990
Phone: (772)288 7206 Fax:(772)223 818(
' Management Agency (FEMA) and is limited to the
accuracy of such maps.
c Flood Zone: X Community 120287 Panel 0406
Suffix: J Date: 2.16.2012
o �
o i:i m
PREPARED FOR:
l" Stephen & Lynn Kiss
--��� Absolute Outdoor Living
VOW 0ye96 -Tool" V/th
Nwssrd Alm" 's Seal
Prepared By:
Kamer Surveying, Inc. LBJ7357
Sheet Tltle+
Boundary Survey
,scale,
1 -20'
Date+
8-I a
Drawn By+
rleld-Book+
G10D-1
1805-35
Job No.,
CADD Flle+
1808-08
Sheet Na,
1 of 1
r1le No.,
SLC-W-13/HR13-1143