HomeMy WebLinkAboutREVISIONI EXISTING A/C COMP. 01 42,000 B.T U. COOLING E ZONE #1 -I� ZONE #2 1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ - - - - - - - - - - - - - - - - -1 r--I -� 1 I / � I ` 1 1 I ® I 1 I i 1 I 1 I I 1 I 1 I I ------------ I I 12" 1 'X4' 40 f / I nX6s 1211X6" 1 200 CFM 1 O CFM 1 12 X6 "X41' I I 4' 300 CFM ° B CFM / B° I 12"XI" // 6n �\ 4�, I Zoo aFM ao cFM loll 4 •' / 85 cFM 48,000 BT,U, 1 8 x4 I A/C 17 8 X 4 C0*bj COOLING I au I 1 I- 40CFM ---- ®--------- Al -4 - + ' • I I 1 I 4" -- -- I SCANNED oil I 8.. 60 F %(( aft ICt I R �11 6 12n \���--------/// T H, V, A, C, NOTES I „ t2' NEW DUCT WORK A II 1\ 12 X6 � — — —— I 200 CFM 4" I I 1 I, VERIFY ALL CALCULATIONS W/ LICENSED AIR CONE). CONTRACTOR BEFORE PROCEEDING W/ WORK 11 an I � I I i I [Ell I o tYX6' I 1 160 CFM d I v 8' 12"X6" 160 CFM VI1111\I1;11111111111�1' Iul��" 8 x a BO CFM 1 „ „ CFM i 12 6 Fm 1 2I 1 2, THE CONTRACTOR SHALL FURNISH ALL REQUIRED - IO" 5 IC I INSURANCE 4 LABOR, MATERIALS 4 EQUIPMENT SHOWN 6 " 1 _ _ _ _ — _ _ _ _ _ _ _ I OR INDICATED FOR COMPLETE H.V.A.C, SYSTEM IN 1211 „ to / i — — — — — — — — — — — — - ACCORDANCE W/ THESE DRAWINGS, LOCAL CODES I I to %%� `\ STANDARD MECHANICAL CODE 4 N.F.P,A. LATEST x 4" f / \ \ EDITIONS 0CFM I^� 3, WORK SHALL BE COORDINATED W/ OTHER TRADES — TO PREVENT CONFLICTING CONDITIONS e i loll— — > - loll — — — — — x 4' CFM I 4, CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS a" 4 INSPECTIONS FROM GOVERNING AGENCIES 4 112" x 6" IN40 4" 4' All x 4" " x 4" I FURNISH A WRITTEN GUARANTEE THAT ALL WORK zoo CFM ell 4" 5o CFM 5 cFM ; SHALL BE FREE FROM DEFECTS IN MATERIALS 4 FM® / I WORKMANSHIP FOR A PERIOD OF NOT LESS THAN ONE 1211 , I YEAR FROM THE DATE OF EQUIPMENT START UP 4 FINAL � r " / 1 ACCEPTANCE, MANUFACTURERS INSTRUCTIONS 4 GUARANTEES SHALL BE GIVEN TO THE OWNER — — - 5, CONTRACTOR SHALL PROVIDE MATCHED SYSTEM — — — — — — — — — — 1-- ----- ---`— � ` � __________ — ' I COMPONENTSOR APPROVEDEQUAL EXISTING A.H'w" _ — — — — — ZONE #I ZONE #2 #1 I 14" I o" x " r FOR OPERATION AT THE SPECIFIED ELECTRICAL 1 THREE 4 HALMI TON I { I _ — - I —1 I rTld I 1 1 I REQUIREMENTS. AIR FILTERS SHALL BE INSTALLED ON W/ 9.96 KW HIAT STRI ; I 1 �4„ " I CE 9- ALL RETURN AIR EQUIPMENT INLETS, RETURN AIR GRILLS IN ATTIC— I — I „ I_ _ _ 1 ; 12j X6° 1 ; SHALL BE DUCTED BACK TO AIR HANDLING UNIT. _ -----I i----------- -----I 6" '40GFM 2O 4° i 8"X4" I I 2701CFM I u 26 I _ _ _ _ _ _ _ _ _ _ _ _ 1 6. SUPPLY DUCTWORK SHALL BE 1 1/2 FIBERGLASS R - 6 o I INSULATED DUCTBOARD OR FLEX DUCT R 6 INSULATED — — — — — — — — — — — — I AS SHOWN ON DRAWINGS. FLEX DUCT SHALL BE FULLY 1 80 CFM - - - - - - - _ 14" �yFYI i \` \ `� i EXTENDED 4 OPEN . } 1 f ' 1 `�` I 1, ALL DUCTWORK JOINTS 4 SEAMS SHALL BE SEALED 4 1 r r = _ _ ; TAPED, FOLLOW MANUFACTURER'S PROCEDURES FOR ALL — I SUCH WORK, EXISTING EXISTING MINI SPLIT I A.H U.SP#2 8. A/C UNIT SHALL HAVE AN SEER RATING OF 16.0 OR A/C COMP I MINI LIT i r — — — — — — — — — — — — — — BETTER AND SHALL HAVE HEAT PUMP PROVIDE BALANCED RETURN AIR FOR PRESSURE LEGEND DIFFERENTIAL PER SECTION 6014 OF THE FL.ORIDA /C MECHANICAL CODE 1 A.N U. #3, FOUR TON I I I 10, PROVIDE STEM PIPE ia CONDENSATE DRAIN LINE TO — — UNIT W/ 43B KW HEAT STRIP 1 r i i SUPPLY CEILING GRILL ADD BLEACH TO PREVENT MOLD BUILDUP I IEN I -WAY W/ 0.6. DAMPER 1 4 I CA.H.U. #4 ONE 4 HALF TON W/ 4.98KW H AT STRIP. MINIS LIT 1 I SUPPLY CEILING GRILL FLAN MINI SPLIT 2 - WAY W/ O.B. DAMPER ' ' i 1/4 =1-O I I I 1 i ; I ,000 B.T U A/C UNIT IT r, ; �� �� I I 1 THESDI,•!,.;0 AND ALL Pr10POSED WOPM SUPPLY CEILING GRILL I ARE;)SjECT TO ANY COFAECT:00 1 ®� 3 - WAY W/ O.B. DAMPER I REQUkuD BY FIELD INSPECTOFS T')AT I MAYE NECESFAN`l IN 0RIMA TO I ��� �J O � I y� ST. Lu��$OUNiV BDILDING - CO�.�?L ITH ALL A.�PUC.AB.E CCOES. I BATHROOM EXHAUST FAN W/ REVIEWED FOR COMPLIANCE 1 I METAL DUCT TO SOFFIT GRILL REVIEWED BY -----I OAT T' STAT 6 + 62" A F F. PLANS AND ERMIT MUST BE EPT ON JOB SITE OR NO INSPECTION(S) ILL BE MADE I I I FLEX DUCT STRAP f 4'-0" O/C — — — I R-6 INSULATED, MAX.LENGTH 14' 1 —7RECEIVED I I I amm®rt�u 1 RIGID DUCT, I I/2" FIBERGLASS NOV 09 2018 ° �0, '& W ego 1 INSULATED, R-6 SET ON 1/2I I , Pe nItingua ent Cp,X, PLYWOOD eog0 ------------------- - - - - - - RETURN AIR CEILING GRILL i m z O LU U � n Q U � � Lu LU O � O� � z r11eo11I®rep 28 JUN 18 5 NOV S O 17165 29 J OFo f�H.# MW ooa DDO